Loading…
Loading…
Tender Value
₹3.3 Cr
EMD Value
₹1.5 L
Closing Date
15 May 2026, 5:00 pmClosed
MR Yognarayan sahu(DFLT)
CE(Ambikapur)
CONSTRUCTION OF BHADIYA MAIN ROAD TO MALLIKAPAT APP. ROAD LENGTH = 2.20 KM, BLOCK - BAGICHA, DISTT. - JASHPUR (C.G.) WORK CODE- W29009
189693
NIT NO: 102/TC/2026-27
RESTRICTED TENDER
WORKS
3 days
CE(Ambikapur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
7 documents required · 7 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE(Ambikapur)
PWD Circle, Ambikapur
Division Jaspur
120
03
No
0
189693
15 May, 2026 5:00:00 PM IST
20 May, 2026 10:00:00 AM IST
24 Apr, 2026 7:00:00 PM IST
NIT NO: 102/TC/2026-27
CONSTRUCTION OF BHADIYA MAIN ROAD TO MALLIKAPAT APP. ROAD LENGTH = 2.20 KM, BLOCK - BAGICHA, DISTT. - JASHPUR (C.G.) WORK CODE- W29009
150000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
32846000.00
2
19 May, 2026 5:00:00 PM IST
32846000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
20d 21h 20m
7 documents required · 6 mandatory · 1 optional
₹0
₹1.5 L
24 Apr 2026
24 Apr 2026
20 May 2026
24 Apr 2026
15 May 2026
24 Apr 2026
19 May 2026
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness if required and as per relevant clauses of section- 200. A In area of light jungle
Excavation in Soil (by Mechanical Means.) Excavation for roadway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all lifts and lead upto 1000 meters as per relevant clauses of section 300.
Construction of Embankment with Material Deposited from Roadway Cutting (Construction of embankment with approved materials having C.B.R.>5 (unless specified otherwise in the contract) deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2)
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 A Plant mix method (with Mechanically crushed stone only) (a) For Lower Sub-base with (i) Grading-III Material
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.
Prime coat Providing and applying primer coat with bitumen emulsion (SS-1, grade confirming to IS:8887) on prepared surface of granular base including clearing of road surface and spraying primer using mechanical means as per clause 502. (i) on WBM / WMM surface @0.85 kg/ sqm.
Tack coat Providing and applying tack coat with bitumen emulsion (RS-1, grade confirming to IS:8887) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per clause 503. (ii) Granular surface treated with primes @ 0.30 kg/ Sqm
Bituminous Macadam (Providing and laying bituminous macadam as per clause 504 with mixed prepared in minimum 40-60 TPH capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction) B With mechanical paver finisher (ii) for Grading-II(19 mm nominal maximum size, bitumen content 3.40%)
Close Graded Premix Surfacing/Mixed Seal Surfacing (Mechanical means using minimum 40-60 TPH capacity of HMP. Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness using bitumen to the required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a Smooth wheeled roller 8-10 tonne capacity, and finishing to required level and grade, complete as per clause 508) II. With mechanical paver finisher A With bitumen ii) Type B ( 13.2 mm to 0.09 mm size aggregates )
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia., across the road ( new construction ) , extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipes as per IRC: 98-2011, bedded on a 0.3 m thick layer of granular material free of rock pieces , outer to outer distance of pipes at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98-2011 and approved drawings. (i) Single row for one utility service 300 mm dia
Dry Lean Cement Concrete Sub-base as per IRC:SP-49 (Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601.)
Providing and laying Unreinforced cement concrete without dowel bars i/c form work, Expantion longitudinol joints as per sesign as per IRC 62-2014 over prepared base as per Approved Mix Design (iii) Minimum cement concrete @ of 375kg/cum P.C.C. M-30
Construction of RCC drain/ cover slab/ chamber (i) Excavation for drain chamber by Mannual means (Earth work in excavation for drain/chamber as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
(ii) Construction of RCC drain/chamber/cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20
(iii) Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as per Drawing and Technical Specifications.
Plain cement concrete complete as per drawing and Technical Specifications (i) PCC Grade M 15
Retro- reflectrorized Traffic signs (Providing and fixing of retroreflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of Micro prismatic grade type reflective sheeting vide clause 801.3, fixed over aluminum sheeting, 1.5 mm thick supported on a mild steel frame of size 40 x 40 x 5 mm and mild steel angle iron post 75 mm x75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing) C Made of Class-A High Intensity Indensity Super Engineering Grade Sheeting of Type II (for ODR & Village Roads) (a) With Aluminum Sheeting of 2mm thickness (ii) 800 mm x 600 mm rectangular
(b) With Aluminum Sheeting of 1.5mm thickness (iv) 600mm x 600mm Squre
Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro- reflectorized sign as per IRC:67-2012 made of Micro prismatic grade type reflective sheeting vide clause 801.3, fixed over aluminum sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75mm x 75mm x 6mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing) C Made of Class-B High Intensity Mirco Prismatic Grade Sheeting of Type IV (for ODR & Village Roads)
Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) (ii) Ordinary Kilometer stone (Precast)
(iii) Hectometer stone (Precast)
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound as per MoRTH Grade 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-1997. The finished surface to be level, uniform and free from streaks and holes.
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material as per Clause 304, loading the unserviceable material in tipper and unloading with all leads & lifts as directed by Engineer-in-Charge. Ordinary soil Upto 3 M. depth
Plain cement concrete complete as per drawing and Technical Specifications (i) PCC Grade M 15
Providing and laying Reinforced Cement Concrete pipe NP 3 /prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) D 1000 mm dia
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification 710.1.4 of I.R.C. 78 and 2200 (i) Granular material
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material including dewatering etc. complete. I Ordinary soil (i) Upto 3 m depth
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. A Using concrete mixer (i) PCC Grade M15
(vi) RCC Grade M25
Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in foundation complete as per drawing and technical specifications as per section 1600.
Providing and laying Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags). D Height upto 5m (a) Using concrete Mixer (ii) R.C.C. Grade M-25
Supplying, fitting and placing HSD bar reinforcement in sub-structure complete as per drawing and technical specifications section 1600 and 2200
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification 710.1.4 of I.R.C. 78 and 2200 (i) Granular material
Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing & Technical specifications section 2706 & 2200
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications 710.1.4 of I.R.C. 78 and 2200
UOM Name
Percentage
Per mile
Per Diem Rate
MAN DAYS
Siemens Per meter
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.08 MB
310909727681151724_152662_9133295183868357873_125601_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
255061243299088648_189693_Form A.doc
NIT • 0.16 MB
5821298169487157575_189693_NEW NIT.doc
NIT • 0.36 MB
3310642142386287028_189693_Notice.docx
NIT • 0.04 MB
4835374125964650510_189693_BOQ.xlsx
BOQ • 0.07 MB
Download all tender documents and submit your bid