Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.1 LAdmitted-Finance 15A PALMER BAZAR ROA D CAL 15 700015 | KOLKATA | WEST BENGAL | 700015 | +0.00% | ₹4.1 L | L1 | Admitted-Finance |
| 2 | L2₹4.2 LAdmitted-Finance | +2.00% | ₹4.2 L | L2 | Admitted-Finance |
| 3 | L3₹4.3 LAdmitted-Finance 1087 LASKARHAT KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | +3.00% | ₹4.3 L | L3 | Admitted-Finance |
Tender Value
₹4.1 L
EMD Value
₹8,500
Closing Date
24 Jan 2026, 1:50 pmClosed
EE(WS)ARSM Sq. BPS
ARSM Sq BPS 15, Raja Subodh Mullick Sq Kolkata-13
ARRANGEMENT FOR IMPROVEMENT OF OUTSIDE ILLUMINATION OF ENTIRE COURTYARD AT RSM SQ BPS
2026_KMC_990194_1
KMC/WS/ARSM/66/2025-26
Open Tender
Electrical Work/ Equipment
7 days
RSM Sq. BPS.
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹8,500
29 May 2026
17 Jan 2026
27 Jan 2026
17 Jan 2026
24 Jan 2026
17 Jan 2026
SUPPLY WITH FITTINGS OF 200 WATT LED FLOOD STREET LIGHT (MAKE AS PER DIRECTION OF E-I-C RATE LAST STORE PURCHASE)
Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/): Size in No & dia. No of Core Sq. mm of wire in mm No of Core - 4 1/2.24 2
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A DP
SUPPLY TMC501 CONVENTIONAL INDUSTRIAL BATTEN PHILIPS LEDTUBE, MODEL NO: TMC 501 P 1*T-LED 22 W P3241.(UNIFIED SCHEDULE OF RATES(M/E), IRRIGATION & WATERWAYS DEPT, PAGE NO- 112, ITEM NO-5.3 F.22)
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc.
Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 6 1/2.80 2
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works 25mm size
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision FOR earthing attachment .Legrand 2+8 way Enclosure (607711)
A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 77. 5 A, piano key type Switch
SUPPLY AND FIXING OF HAVELLS POST TOP LUMINARIES WITH 4M POLE AND POLE BASE COVER, LUMINARIES MODEL NO : CORAL PT35WLED (35WATT) OVER THE PREINSTALLED MUFFING BY GROUNING NUTS AND BOLTS COMPLETE INCLUING WIRING FROM LOOP BOX TO THE LIGHT BY 1.5 SQ MM CU WIRE((UNIFIED SCHEDULE OF RATES(M/E), IRRIGATION & WATERWAYS DEPT, PAGE NO- 113, ITEM NO-5.3 F.16)
5.3 F.29 SUPPLYING OF DIFFERENT TYPES OF LED LAMPS (40W) 5.3 F.29.1 MAKE : PHILIPS, 40.0 WATT, BASE B22/ E27, 4000LM(UNIFIED SCHEDULE OF RATES(M/E), IRRIGATION & WATERWAYS DEPT, PAGE NO- 114, ITEM NO-5.3 F.29)
FITTINGS : Fixing only lamp
Fixing only SPN MCBDB (4 to 16 way) on flat iron frame on wall 415V TP/TPN
A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 28. Angular batten Holder (Anchor)
Laying through Underground Trech.(a)Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Finishing cable ends.(b)Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.2 core 10 sqmm cable
Compression Glands.Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring FOR dust & moisture(proof entry of XLPE/PVC armoured cables as below : FOR 2 core.upto 10 sqmm.
Earth continuty condnetor Connecting the equipments to earth busbar including S & F GI (HOT Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.Solid GI wire.No. 8 SWG
(H) Street lights :2. Distribution wiring FOR steel light on pole FOR outdoor fluorescent/SV/MV light fitting with 2x1/1.40 PVC insulated and sheathed wire (single core) in 15 mm dia GI Pipe (ISI Medium), without control switch, incl. fitting and fixing the light fitting by providing 32 mm dia GI Pipe bracket of lengh 1.05 mts, on pole incl. S&F sutable MS flat clamps with bolts, nuts etc. as required and painting
Sub Total
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.77 MB
BOQ_2420090.xls
BOQ • 0.30 MB
TBID.pdf
Tender Documents • 0.74 MB