Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.8 CrAccepted-AOC 71 GOLA MAHAL SADAR BAZAR BARRACKPORE KOLKATA 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | ₹1.8 Cr | L-1 | Accepted-AOC Being lowest bidder |
| 2 | L-2₹1.8 Cr+₹6.5 L (3.66%)Rejected-Finance SRIKONA POTAPOLA CHHAKA CHANDIPUR ROAD BALASORE ODISHA 756025 | BALASORE | BALESHWAR | ODISHA | 756025 | ₹1.8 Cr+₹6.5 L (3.66%) | L-2 | Rejected-Finance Not being lowest bidder |
| 3 | L-3₹1.9 Cr+₹12.1 L (6.82%)Rejected-Finance KACHERY ROAD BALASORE 756001 ODISHA | BALESHWAR | ODISHA | 756001 | ₹1.9 Cr+₹12.1 L (6.82%) | L-3 | Rejected-Finance Not being lowest bidder |
| 4 | L-4₹2.0 Cr+₹26.4 L (14.9%)Rejected-Finance 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | ₹2.0 Cr+₹26.4 L (14.9%) | L-4 | Rejected-Finance Not being lowest bidder |
| 5 | L-5₹2.2 Cr+₹47.0 L (26.5%)Rejected-Finance PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | ₹2.2 Cr+₹47.0 L (26.5%) | L-5 | Rejected-Finance Not being lowest bidder |
Tender Value
₹1.9 Cr
EMD Value
₹2.7 L
Closing Date
14 Oct 2023, 6:00 pmClosed
CE RND Delhi
HQ CE RND, Timarpur, Delhi-54
SPECIAL REPAIR OF SAFETY CENTRE BUILDING AT ITR CHANDIPUR
2023_MES_614268_1
CE RND/DLI-25/CHANDI/2023-24
Open Tender
Civil Works
Item Rate
273 days
Chandipur
As per tender documents
8 documents required · 8 mandatory
₹2,000
GE I RND CHANDIPUR
₹2.7 L
Yes
23 Nov 2023
18 Aug 2023
20 Oct 2023
18 Aug 2023
14 Oct 2023
30 Sept 2023
Amount
Demolishing brick work in cement mortar manually/ by mechanical means including disposal of unserviceable material complete all as specified and as per direction of Engineer-in-charge.
Demolishing cement concrete of any description and in any position not otherwise specifically provided for manually/ by mechanical means including disposal of material complete all as specified and as per direction of Engineer - in - charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by engineer in charge.
M&L for providing and laying in position cement concrete 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) complete all as specifed and as directed by engineer in charge - All work up to plinth level
M&L for providing and laying cement concrete pavement 100mm thick with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), as in pavement/hardstanding/path, laid to required slope and camber in panels as required including consolidation, tamping, finishing fair & even complete all as specified and as directed.
M&L for providing and filling in position PU sealing compound for sealing of expansion / dummy joints in PCC pavement / hard standing / path complete all as per manufacturers instruction and as directed by Eng-in-charge.
M&L for Brickwork with flyash bricks, conforming to relevant IS straight or curved on plan exc 6m mean radius built in Cement mortar 1:4 (1 cement : 4 coarse sand) complete all as specified and as directed.
M&L for Brickwork with flyash bricks, conforming to relevant IS straight or curved on plan to any radius in half brick thick walls built in Cement mortar 1:4 (1 cement : 4 coarse sand).
M&L for treatment of soil under existing floors using chemical emulsion Chlorpyriphos/ Lindane E.C. 20% with 1% concentration @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floors complete all as specified and directed.
M&L for providing and laying Double charge vitrified tile polished finish of size 600 x 1200 mm or more in floor (minimum 8 mm thickness or to be specified by the manufacturer which ever is higher) in any colour and shade with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed
M&L for providing and laying double charge Vitrified tiles polished finish of size 600 x 1200mm or more (minimum 8 mm thickness or to be specified by the manufacturer which ever is higher) in any colour and shade with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete all as specified and directed.
M&L for providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (minimum 8-10mm thickness or to be specified by the manufacturer which ever is higher), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete all as specified and as directed.
M&L for providing and fixing double charged vitrified tiles polished finish of size 600x600 mm or more (minimum 8mm thickness or to be specified by the manufacturer which ever is higher), of approved make, in all colours, shades except burgundy, bottle green, black of size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
M&L for providing and laying Polished Granite stone flooring colour of Black, Cherry/Ruby Red or equivalent in required design and patterns, of minimum size 900x1800mm, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18-20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Note:- Quality, shade and thickness shall be approved by users as well as GE in writing.
M&L for providing and fixing 18-20 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite stone slab colour black, Cherry/Ruby red for as in skirting/dado, Area of slab upto 0.50 sqm, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. completeat all levels
Taking down old plaster or skirting including raking out joints, hacking for key, scrubbing down with water, etc. and cleaning the surface for plaster including disposal of rubbish complete all as specifed and directed by engineer in charge.
M & L for 12 mm thick cement plaster on other than fair finish of single or half brick wall of mix 1:6 (1 cement: 6 fine sand) complete all as specified and directed.
M & L for 6 mm thick cement plaster on ceiling surface of mix 1:3 (1 cement : 3 fine sand) finished even & fair complete all as specified and directed.
M & L for 15 mm thick cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) mixed with WPC complete all as specified and directed.(WPC Shall me measured separately).
M&L for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr. of average thickness 1 mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc by skilled labour as per following steps:- Step-1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step-2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI Step-3) Allow 6-8 hrs time to dry the putty surface.
M&L for preparation of new wall surfaces and applying 1.0 mm thick wall care putty finished even and smooth and applying two coats of smooth interior acrylic emulsion paint applied over one coat of acrylic water based interior grade primer @ 0.8 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio using fully automatic airless spray machine/technology with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine shall be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and accessories for applying smooth interior acrylic emulsion shall be able to spray in hard to reach areas and penetration of smooth interior acrylic emulsion on the surface complete all as specified and directed.
M&L for preparation of existing surfaces and applying one coats of smooth interior acrylic emulsion using fully automatic airless spray machine/technology with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying smooth interior acrylic emulsion shall be able to spray in hard to reach areas and penetration of smooth interior acrylic emulsion on the surface complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paint application.
M&L for preparation of newly platered wall surface and applying two coats of premium acrylic smooth exterior emulsion 100% weather proof with anti fungal properties of approved colour with silicon additive & color stay technology, excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water water based exterior grade primer @ 0.90 ltr (undiluted) / 10 Sqm diluted with water in 1:1 ratio and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI and allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed. Make : Asian Paints Ultima Protect/Nerolac excel top guard/Berger weather coat long life
M&L for complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. and applying two coats of premium acrylic smooth exterior emulsion 100% weather proof with anti fungal properties of approved colour with silicon additive & color stay technology, excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water water based exterior grade primer @ 0.90 ltr (undiluted) / 10 Sqm diluted with water in 1:1 ratio and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI and allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed. Make : Asian Paints Ultima Protect/Nerolac excel top guard/Berger weather coat long life
Note for Srl Item No. 20 to 24:- (a) Work shall be done as per MoU between tenderer and manufacturer of paints and their authorized applicator complete all as specified and directed. (b) The Contractor shall upload MoU between tenderer and manufacturer of paints and their authorized applicator before quoting the bids and submit the same alongwith performance security of tender. (c) Cost of scaffolding at any height shall be included in the quoted rate. (d) Preparation of plastered or unplastered surface or removal of existing treatment by scrapping of walls, chajjas ceilings, fins, fascias, parpets etc shall be done by using mechanical sander with internal dust extraction system for clean environment certified by the manufacturer. After the preparation of surface written approval shall be obtained from GE before applying primer and further treatment coats. Bldg wise stage passing register shall be maintained. (e) Finished ie cement based paint, acrylic water based exterior grade primer, premium acrylic smooth exterior emulsion etc to walls, ceiling, chajjas, fins, fascias, prapets etc shall be applied using airlessspray technology and capable of operating single spray gun with a suitable hose length. The spray machine should be of areputed manufacturer with pro-guard technology and capability of tracking pressure as well as paint and primer usage. (f) This equipment shall be certified by approved manufacturer. (g) The accessories for applying the finishes shall be spray in hard to reach areas and penetration of finishes on the surface so asto achieve uniform application and quality surface finish. (h) The Contractor shall submit approved company generated 05 years warranty card at the time of submission of RAR and Final Bill.
M & L for taking down existing WPT of any description including PCC padding etc. roughening surfaces of old concrete floors / slabs and washing down with water to remove dust particles complete including preparation of surface to receive plastering and removal of debries outside MD land complete as per direction of Engineer-in-Charge.
M & L for PCC on roof padding 25mm thick with Cement concrete 1:2:4 type B-0 (1 cement : 2 coarse sand :4 graded stone aggregate 12.5mm nominal size) complete all as specifed and as directed.
M & L for plaster on roof 12mm thick for water proofing treatment with Cement mortar 1:4 (1cement : 4 coarse sand) mixed with water proofing compound (WPC) (WPC Shall be measured separately)
M & L for cutting grooves in Brick/concrete wall 75 mm wide and 65 mm deep and shaping horizontal of grooves with cement mortar 1 : 3 complete all as specified and directed .
M&L for providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane complete all as specified and as directed.
M & L for PCC tile of size 300x300x25mm laid over APP membrane over 15mm thick screed bed in cement mortar 1:4 complete all as specfied and as directed.
Supply only water proofing compound (WPC) conforming to relevant IS
Dismantling of old S.W. pipes 150mm diameter including breaking of joints and bed concrete and disposal of unserviceable materials complete all as specifed and as directed.
Excavating trenches in all kind of soil of required minimum width as per SSR for pipes, cables, etc exceeding 80 mm dia but not exceeding 300 mm dia including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning filling the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed complete all as specified.
M&L for providing and laying Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; in cement concrete 1:4:8 D2 (1 cement : 4 coarse sand : 8 graded stone aggregate) all-round 150 mm diameter pipes complete all as specified and directed.
M&L for providing, laying and jointing RCC NP-2 pipes 150 mm inner diameter with collars and jointing with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete all as specified and directed.
M&L for providing and fixing in repair 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS:8931 complete all as specified and as directed. Make- Cat part No. CON-107KN of jaquar/cat part No. F330011 of Hindware/cat Part No. G1805A1 of parryware or equivalent of make kohler.
M&L for providing and fixing in repair white vitreous wash basin size 550x400 mm with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require complete all as specified and directed. Make of pillar tap-Cat part No. CON-021KN of Jaquar/Cat Part No. F-730002 of Hindware/Cat Part No. G1802A1 of Parryware or equivalent make of Kohler.
M&L for providing and fixing in repair 15mm nominal bore C.P. brass angle valve of approved quality conforming to IS:8931 complete all as specified and directed. Make- Cat part No. CON-059KN of jaquar/cat part No. F330043 of Hindware/cat Part No. G1853A1 of parryware or equivalent make of kohler.
M&L for providing and fixing in repair uplasticised PVC connection pipe 45cm long 15mm nominal bore with brass unions nuts complete all as specified.
M&L for Providing and fixing White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (Indian type W.C. (pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including Dismantling W.C. Pan and flushing cistern of all sizes and disposal of dismantled materials i/e malba, cutting and making good the walls and floors wherever required all complete as per directions of Engineer-in-Charge.
M&L for Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with white solid plastic seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including Dismantling and disposal of dismantled materials i/e malba, cutting and making good the walls and floors wherever required all complete as per directions of Engineer-in-Charge.
S&F CP brass 2 way angle cock with flange complete all as specified and directed. Make- Cat part No. CON-059KN (two way) of jaquar/cat part No. F330006 of Hindware/cat Part No. G2843A1 of parryware or equivalent of make kohler.
S & F in repair, CP brass Health faucet with 8mm dia, 1.2 Meter long flexible tube & wall hook complete all as specified and directed. Make- Cat part No. ALD-587 of jaquar/cat part No. F160110 of Hindware/cat Part No. T9875A1 of parryware or equivalent of make kohler.
M&L for providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, 20 mm nominal dia having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints and including dismantling of old GI pipe and stacking of dismantled pipes (within 50 metres lead) complete as per direction of Engineer-in-Charge.
Description complete all as per item no 44 here in before but 25 mm nominal dia.
M&L for Providing and fixing ball valve 25 mm nominal bore(brass) of approved quality, High or low pressure, with plastic floats complete all as specified and as directed
M&L for Providing and fixing in repairs Vitreous China urinal flat back, single half stall of size 580 x 380 x 350 mm white (minimum), with grating and union for discharge pipe including CP waste pipe, CP flush pipe, CP urinal spreader with clamp and self closing angle cock of Make - Cat Part no. PRS-077 of Jaquar/Cat Part no. F310016 of Hindware/Cat Part no. G2007A1 of Parryware or equivalent make of Kohler including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and as directed.
M&L for Providing and fixing on wall face unplasticised Rigid PVC rain water single socketed pipes 75 mm diameter conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, including Dismantling 100mm dia old C.I. rain water pipe with fittings and clamps including stacking the material within 50 metres lead complete all as specified and directed.
M&L for Providing and fixing on wall face unplasticised - PVC moulded fittings/Bend 87.5° of 75mm dia for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion
M&L for Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
S&F in repairs towel rail 600 mm long 20 mm dia, D type Brass chromium plated fixed to wall with CP steel screws etc, complete all as specified and directed. Make - Cat Part no. ACN-1111SM of Jaquar/Cat Part no. F450024 of Hindware/Cat Part no. T6401A1 of Parryware or equivalent make of Kohler
Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge
M&L for providing and placing on terrace (at all floor levels) polyethylene water storage tank 1000 ltr capacity, three layered IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified
M&L for Providing and fixing PTMT extension nipple 25mm nominal bore, weighing not less than 62 gms for water tank pipe, fittings of approved quality and colour complete all as specified.
Taking down doors, windows and clearstorey windows shutters any description of area 3 sq. metres and below including chowkhats, architrave, holdfasts etc. complete.
M&L for Providing kiln seasoned and chemically treated 2nd class hard wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) complete all as specified and as directed.
M&L for Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete all as diected by engineer in charge.
M&L for Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : for fixed portion, Powder coated aluminium (minimum thickness of powder coating 50 micron)
M&L for Providing and fixing factory made uPVC frame with shutter of any color Sliding window Two track made of extruded profiles with wall thickness of 2.3mm (+- 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 62mm). sash (42mm x 67mm). Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm). Glazing bead (24.5mmx 16mm) will he mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel frame (30mm x 21.5mm), Sash (30mmx 18mm), profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware : [Touch Lock of zinc alloyed (white powder coated), steel roller system including 6 mm thick toughned tinted glass to be catered, aluminum track on bottom rail for two track sliding frame, wool pine for Sliding sash and interlock complete all as specified and as directed. (Note: The quoted rate shall be deemed inclusive of other connected accessories. Net opening will be measured for payment purpose)
M&L for Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment)
M&L for Providing and fixing 12 mm thick prelaminated particle board with decorative lamination on one side and balancing lamination on other side flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per directions of engineer-in-charge.
M&L for Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the directions of engineer-in-charge, with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) complete.
Description complete all as per item No 62 here in before but with frosted glass panes 4 mm thickness.
M&L for Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete all as directed by engineer in charge.
M&L for Providing and fixing 125mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified
M&L for Providing and fixing aluminium hanging twin rubber floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete all as specified.
M&L for Providing and fixing 300 x16mm aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete all as specified.
M&L for Providing and fixing 200 x 10mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and directed.
M&L for Providing and fixing 20 mm diameter Stainless Steel of grade-304 curtain rods of wall thickness 1.25 mm with two Stainless Steel of grade-304 brackets fixed with SS screws and wooden plugs etc. wherever necessary complete all as directed by engineer in charge. Note: One set of two cap/dome as approved shall be provided both end of each curtain rod.
M&L for Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin- Charge
M&L for Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing.
Dismantling wooden boardings of thickness above 10 mm up to 25 mm in lining of walls and partitions, excluding supporting members and removal complete.
M&L for Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand in boxes, shelves, racks, almirah, cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-in-charge.
M&L for Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete all as specified and as directed.
M&L for Providing and fixing in position collapsible mild steel (MS) shutters with vertical channels 20x10x2 mm and braced with MS flat iron diagonals 20x5 mm size, with top and bottom rail of MS T-iron 40x40x6 mm, with 40 mm dia mild steel pulleys, complete with MS bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer complete all as specified and directed.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead
M & L for steel work welded in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required complete all as specified and as directed.
M&L for Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
M & L for finishing with Epoxy paint (two or more coats) on steel work at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete as per manufacturer's instructions and as directed.
M & L for painting with synthetic enamel paint on wood surface of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade of primer of approved brand and manufacture complete all as specifed and as directed.
M & L for coal tarring two coats on new wood work using 0.16 Litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively complete all as specified and as directed.
M&L for Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills, cover slabs and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) complete all as specified and as directed.
S & F Steel reinforcement Thermo-Mechanically Treated bars (TMT) of grade Fe-500D or more for R.C.C. work including straightening, cutting, bending, placing in position and binding complete all as specified and as directed. above plinth level
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials.
S&F false ceiling with designer tiles fibre cement boards 6mm thickness as per IS-14862 (design Occeanic, lake & hill, cascade or electra) ivory/white colour as approved of size 595x595 mm each fixed over true horizontal level suspened on interlocking prepainted "centra Black pattern" metal grid steel section (galvanised 120 gsm, both side inclusive) consistingg of Main 'T' runner with suitably spaced joints to get required legth and 15x32 mm made of 0.30 mm sheet and cross 'T' @ 600 mm c/c to form a grid including required cutting/making, opening for service like difusers, light fittings, fixtures, smoke detector etc. Main 'T' runner to be suspended from ceiling using GI soffit cleats fixed to existing ceiling/rafter/purlins etc with galvanised butterfly level clips spaced @ 1200 mm c/c alongwith 'T' bottom exposed width of all 'T' shall be minimum 15 mm of "centra black pattern" prepainted with polyster paint and having load carrying bearing capacity 12.00 kg/sqm complete all as specified as approved and directed.
Supply and fix 1st Quality decorated venetian blind of any design/colour/size of vertical roller movement as approved by Engineer in Charge and fixed with bracket and other fixing tools as per manufacturer instruction complete all as specified and as directed.
Taking down carefully concealed aluminum/copper point wiring (Light fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators socket, light fittings etc removing materials for taking credit and making good disturbed surfaces of wall, floor, etc.
M&L for point wiring for light point/fan point/exhaust fan point/call bell point with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm for earth continuity wire, to be drawn in and including PVC conduit medium duty with concealed wiring, MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick switch board with 5/6 A piano switch flush type one way 240 V and brass screws with cap washers for one light/Fan point controlled by one single way switch including all necessary wall cutting and making good disturbed surface complete.
M&L for power plug for 15 Amp Independent switch socket board with PVC insulated unsheathed stranded FRLS copper conductor cable of size 2x4 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1x4 Sqmm for earth continuity wire, to be drawn in and including PVC conduit heavy duty with concealed wiring including all necessary wall cutting and making good disturbed surface
S& F metal boxes of size 75mm x75mmx 60mm deep of thickness 1.2mm on surface or recess with suitable size of phenolic laminated sheet cover of thickness 3mm in front including painting and making good of good disturbed surfaces
S& F metal boxes of size 100mm x100mmx 60mm deep of thickness 1.2mm on surface or recess with suitable size of phenolic laminated sheet cover of thickness 3mm in front including painting and making good of good disturbed surfaces
S& F metal boxes of size 150 mm x75mmx 60mm deep of thickness 1.2mm on surface or recess with suitable size of phenolic laminated sheet cover of thickness 3mm in front including painting and making good of good disturbed surfaces
S&F Socket outlet 3 in 1, 5 pin, 5 Amps flush type 240 Volt .
S&F socket Outlet, 5 in 1 ,3 pin 15/16 amps flush type 240 Volt
S&F switch 5/6 Amps flush piano type one way 240 Volt .
S&F switch 15/16 Amps flush piano type one way 240 Volt .
S&F Ceiling rose 5A, 3 terminal PVC/poly carbonate isolated body on existing jucntion box including connections etc. as required
S & F Electronic fan regulator, stepped type 120/280V 100Watt on existing phenolic laminated sheet complete all as directed by Engineer-in-Charge.
Taking down Sub main /Sub circuit wiring of any type and size including conduit / casing capping / batten wiring complete all as directed by Engineer-in-Charge.
M&L for Sub main wiring using two runs of FRLS grade PVC insulated, unsheathed, stranded, copper conductor cable of size 2.5 Sqmm and one run of 2.5 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including at least 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size complete all as specified and as directed. (Note:- 3 run of copper wire and PVC conduit shall be measured as one unit)
M&L Sub main wiring using two runs of FRLS grade PVC insulated, unsheathed, stranded, copper conductor cable of size 6.0 Sqmm and one run of 6.0 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including at least 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size complete all as specified and as directed. (Note:- 3 run of copper wire and PVC conduit shall be measured as one unit)
M&L Sub main wiring using two runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 4 Sqmm and one run of 4 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including at least 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size complete all as specified and as directed. (Note:- 3 run of copper wire and PVC conduit shall be measured as one unit)
M&L Sub main wiring using four runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 6 Sqmm and 2 run of 6 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, copper wire to be drawn in and including non metallic rigid PVC conduit concealed in wall including cutting and chassing the wall as per site requirement and making good disturbed surface of walls complete all as specified and as directed. (Note:- 6 run of copper wire and PVC conduit shall be measured as one unit)
M&L Sub main wiring using four runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 10 Sqmm and 2 run of 10 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, copper wire to be drawn in and including non metallic rigid PVC conduit concealed in wall including cutting and chassing the wall as per site requirement and making good disturbed surface of walls complete all as specified and as directed. (Note:- 6 run of copper wire and PVC conduit shall be measured as one unit)
Supply and fixing of following ways surface/recess mounting vertical type, 415 volt TPN MCB 8 way (4 + 24 ) double door distribution board of sheet steel, dust protested duly powder painted, inclusive of 200 amps tinned copper bus bar common neutral link, earth bar, din bar for mounting MCB's (but without MCB,s and incommer ) as required (Note Vertical type MCB TPDB is normally used where 3 phase outlets are required) including taking down old DB and making disturbed surafce good to match the existing surface.
S & F following way horizontal type three pole and neutral sheet steel, MCB distribution board, 415 V, 4 way ( 4 + 12) double door on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc as required ( but without MCB/RCCB/Isolator) including making good disturbed surfaces including taking down old unserviceable , complete all as directed by Engineer-in-Charge.
S & F following way single pole and neutral 8 way sheet steel MCB distribution board, 240 volts on surface/recess complete with tinned copper bus bar neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc, as required (but without MCB/RCCB/Isolator)
Providng and fixing 4 pole 100 A, 30 KA FP MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubilcle panel, making connection etc ar reuired.
S & F in repair , MCB, TPN, 415 V, 50Hz, 16kA, 'C' series, 63 Amps series.
S & F 5A to 32 A rating, 240V/415 V, 10 kA "C" curve miniature circuit breaker triple pole suitable for inductive load of following poles in the existing MCB DB complete with connection testing and commissioning etc as required.
S & F 5A to 32 A rating, 240V/415 V, 10 kA "C" curve miniature circuit breaker single pole and neutral suitable for inductive load of following poles in the existing MCB DB complete with connection testing and commissioning etc as required.
S & F 5A to 32 A rating, 240V/415 V, 10 kA "C" curve miniature circuit breaker single pole suitable for inductive load of following poles in the existing MCB DB complete with connection testing and commissioning etc as required.
Supply and fix LED light fitting 36 Watt recess mounting, ultra slim edgelit panel with SMD LED, extrusion aluminium housing anti glare diffuser, recess mountin 2ftx2ft square type with all accessories IP-20l including taking down old us CFL fittings any type complete all as specified.
Supply and fix LED tube light fitting 2x20 Watt decorative batten with SMD LED, retrofitted with T-8 polycarbonate tube light powder coated box type channel with all accessories including taking down old us complete all as specified
Supply and fix LED tube light fitting 1x20 Watt decorative batten with SMD LED, retrofitted with T-8 polycarbonate tube light powder coated box type channel with all accessories including taking down old us complete all as specified
Supply and fix LED tube light fitting 10 Watt, 2 ft decorative aluminium extruded T5 LED Batten integrated type including taking down old us complete all as specified
S&F in repair LED security light fitting 45 Watt with all accessories, (with extra driver) attractively styled high pressure die cast housing acting as a heat sink housing epoxy powder coated in dark graphite grey colour suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories including taking down old fitting as directed.
S & F 20A 240 V SPN industrial type socket outlet with 2 pole and earth metal enclosed plug top alongwith 20 A "C" SP, MCB, in sheet steel enclosure on surface or in recess with chined metal cover for the socket out let and complete with connection testing and commissiong etc as required.
M&L Bus Bar Panel of capacity 200 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 50x50x6 mm thick grounting in floor, 0.45 mm depth grounting with PCC 1:3:6 upto ground level all as specified and directed.
M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate), 50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. (Note : GI strip upto 7.5 m length shall be deemed to include in the cost of above item.
Supply and Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade of 50 sqmm 3.5 core size direct on wall with shadling screew, washer complete with all as specified and directed.
Taking out old Aluminium strip from wall/roof top and keeping in safe custody for re-use and taking credit
Dismantling of PCC and taking out Air termination rod with GI Pipe complete all as directed by engineer in charge and keeping in safe custody for re-use and taking credit
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connection etc as required complete all as specified and as directed.
Fixing only Single pointed air terminal Aluminium rod of 12 mm dia 300mm long complete all as specified and directed
Providing and fixing of lightning conductor finial, made of 25 mm dia, 300 mm long, GI tube medium grade, having single 85mm dia and 6 mm thick MS base plate including holes etc complete all as direced by engineer in charge.
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connection etc as required.
S & F of Test Point terminal block made of Gun Metal or Phosphorus Bronze size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia, 25mm long Hexa head screw complete all as directed.
M&L for cement concrete for foundation of Air Terminal 1:2:4 (1 cement : 2 coarse sand : graded stone aggregate 20 mm nomianl size) complete all as specified and as directed.
Supply and fixing of GI pipe light grade for Air terminal of size 25mm bore dia length as per site requirment all as spd and directed.
Providing and laying GI earth strip 32 mm x 6 mm from earth electrode directly in ground as required complete all as specified and directed by engineer in charge.
Supply, installation, testing and commissioning of detectors complying with and type certified to EN-45 addressable type smoke detector photoelectric/optical with Intelligent Base with self built intelligence as per IS:11360
Description complete all as per item No. 134 here in before but addressible type analog thermal sensor (heat detector) with intelligent base with rate rise cum fixed temperature as per IS-2175
Supply, installation, testing and commissioning of addressable Die cast double action Manual pull station (manual call point) with surface mount Back box and mini Monitor complete all as specified and directed
Supply, installation, testing and commissioning of fire alarm sounder with facility to make annoucment mounted in MS box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc compplete as required.
Supply, installation, testing and commissioning of intelligent audio visual strob with base complete all as specified and directed
Supply, fixing and testing PVC insulated FRLS copper conductor cable twin core 1.5 sqmm armoured 1100 volts drawn throught and including suitable size of stove enamelled steel conduit complete all as specified and directed
GAS SUPPRESSION SYSTEM Supply, installation, testing and commissioning of complete system of gas suppression with 56 kgs FK-5-1-12 in one cyclinder, pneumatic actuator, tube, magnetic actuator, check valve, pressure guage complete system all as specified and directed.
Supply and fixing nozzle made of brass of 56mm dia fixed in MS tube grid for spreading gas with adquate pressure complete with all connecting accessories complete all as directed.
Supply, fixing and making grid of MS tube 25 mm bore dia and 15 mm bore dia medium grade covering the entire room including making hole in wall/ceiling and making good the disturbed surfaces with all fittings complete all as specified and directed.
Supply, installation, testing and commissioning of Gas Suppression system Control Panel complete with Smoke Detector, Heat detector, Manual Call point, Manual release abort each 01 No complete with connecting with standard size of cable all as specified and directed of make as approved by GE in writing.
M&L for Providing and fixing pre-moulded joint filler of size 75x20mm in expansion joints of PCC pavement / hard standing / path after making the joints dust free with high pressure air jet cleaners all as specified and directed. Note - Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS:1834 for hot sealing bitumen compound grade 'A'.
M & L for Forming dummy joints of 10 mm width and 30 mm depth in PCC pavement / hard standing / path all as specified and directed by Engr-in-charge.
M&L for Providing and laying polished granite stone 18-20 mm thick on stair case in single piece of colour Black, Cherry/Ruby red or equivalent in required design and pattern, in linear as well as curvilinear portion of the building including making three groves upto full length of granite stone over 20 mm thick base of cement mortar 1:4 laid and jointed with cement slurry and pointed with white cement slurry mixed with pigment of matching shade including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. all as specified and directed by Engineer-in-charge. Note:- Quality, colour, shade and thickness of granite shall be approved by GE as well as user before incorporating in the work.
M&L for complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. and preparation of surfaces by providing 1.0 mm thick wall care putty finished even and smooth and applying two coats of smooth interior acrylic emulsion with Texture finish having VOC less than 50 grams per ltr complying LEEDS criteria @1 ltrs(undiluted) /10 sq mtrs diluted with water in 2:1 ratio applied over one coat of acrylic water based interior grade primer @ 0.8 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio using fully automatic airless spray machine/technology with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying smooth interior acrylic emulsion shall be able to spray in hard to reach areas and penetration of smooth interior acrylic emulsion on the surface complete all as specified and directed.
M&L for 12 mm thick tinted toughened glass as in door incl all fitting like SS clip, lock handle as approved etc. complete all as specified and directed.
M&L for dismantling of split AC of capacity upto 3.00 TR by pump down the gas and removing from site and keep in safe custody and refix the same in old or new position by fixing of new outdoor stand with anchor bolt and complete serviccing including gas filling complete all as specified and directed.
S&F of 32mm dia bore medium grade PVC conduit alongwith conduit accessories in surface/concelaed including cutting of wall and making good to match with existing surfaces complete all as directed.
S&F of 32mm dia bore medium grade PVC conduit alongwith conduit accessories in surface/concelaed including cutting of wall and making good to match with existing surfaces complete all as directed.
bholanath bera
R.B.Construction
Leo Network power systems
RANA ENTERPRISES
FRIENDS CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .