| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51,293Accepted-AOC BOOTH NO 14 SECTOR 33A CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹51,293 Quoted ₹51,292.71 | L1 | Accepted-AOC L1 |
| 2 | L2₹62,908.09Rejected-Finance BLOCK B SECTOR 26 CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹62,908.09 | L2 | Rejected-Finance L2 |
| 3 | L3₹66,731.92Rejected-Finance BLOCK B SECTOR 26 CHANDIGARH | ₹66,731.92 | L3 | Rejected-Finance L3 |
| 4 | L4₹68,356.02Rejected-Finance CHANDIGARH | ₹68,356.02 | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical 109 MALOYA CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | - | - | Rejected-Technical Not qualified technical bid |
Tender Value
₹1.0 L
EMD Value
₹2,100
Closing Date
17 Feb 2026, 12:00 pmClosed
Er. Chander Shekhar
Office of the Executive Engineer, Electrical Division No. 3 Sector-4, Chandigarh.
Providing renovation of house no.562, Type-11, sector-11, U.T. Chandigarh. (E.I. Work)
2026_CHD_90594_1
E3/47W/209
Open Tender
Electrical Works
30 days
Chandigarh
as per NIT
2 documents required · 2 mandatory
₹0
₹2,100
25 Mar 2026
11 Feb 2026
17 Feb 2026
11 Feb 2026
17 Feb 2026
11 Feb 2026
DSR Item No.1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3x 4 sq. mm.
DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
DSR Item No.1.22 Supplying and fixing metal box of following sizes(nominal size) on surface or in recess with suitablesize of phenolic laminated sheet cover in frontincluding painting etc. as required.
75 mm X 75 mm X 60 mm deep
200 mm X 150 mm X 75 mm deep
200 mm X 250 mm X 75 mm deep
250 mm X 300 mm X 60 mm deep
DSR Item No. 1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 amps switch
3 pin 5/6 A socket outlet
15/16 amps switch
6 pin 15/16 A socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell Push
DSR Item No.1.29 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
DSR Item No.1.30 Supplying and fixing metal box of 180mm X 100mm X 60mmdeep (nominal size) on surface or in recess with suitable size ofphenolic laminated sheet cover in front including providing andfixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano typeswitch, connections, painting etc. as required.
DSR Item No.1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
DSR ITEM NO.2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
DSR ITEM No.2.16 Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A 240 V "C" curve DP MCBcomplete with connections, testing and commissioning etc. as required.
DSR ITEM No.2.3 Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator)
For 8 way, Double door
DSR ITEM No.2.23Supplying and fixing Cable End Box (Loose Wire Box) suitable forfollowing single pole and neutral, sheet steel, MCB distributionboard, 240 Volts, on surface/ recess, complete with testing andcommissioning etc. as required.
For 8 way, Double door SPN MCBDB
DSR Item No.1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
DSR item no. 5.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
DSR item no. 5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
DSR 8.10 LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
DSR 9.2 Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum)
Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole in existing wall suitable size of above fan making in original shape of wall. The size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. The Exhaust fan should be Havells/Orient and Bajaj make only.
Size 12 inches (300mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells make (Turbo Force SP)/ Crompton make ( EXHD300-6-1)/ Bajaj make (Supreme Plus)/ Orient make (Industrial Heavy Duty)/ Usha Make (Turbo HDEF) make only.
Supply and Erection of B.L. Holder of make anchor/ havells ISI marked on the existing junction box/ wooden block including making the connection etc. as required. The job includes the all labour and petty material charges required to complete the job to the entire satisfaction of E.I.C. of work.
S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA/ PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen at 100 lm/ watt (minimum) and the driver of the fitting should be workable on 140-260 Volt. The colour temperature of LED should be minimum 5000 degree Kelvin. The fitting should be of Philips/ Bajaj/ Wipro/ Havells/ Jaquar/ Crompton/ Panasonic/ Surya/ LT/ Trilux make only. The fitting should be of IP-65/66. The LED should have a life of 50000 burning Hours. The fitting should have THD<15% and power factor 0.9 or above. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer In Charge.
Supply and erection of PVC gang box of suitable size without switch socket etc. The job includes cost of labour and other petty material required to complete the job to the entire satisfaction of Engineer-in-charge of the work.
For 5/6 Amp switch/socket
For 15/16 Amp switch/socket
S/E of Backlight sheet 3 mm thick white colour of hylum/Formica make only to be fixed on the existing switch boards including screws, washer etc. after making holes. The job includes all labour and petty material to complete the job to the entire satisfaction of the E.I.C. of work.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 24.92 MB
BOQ_110793.xls
BOQ • 0.27 MB