Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC | ₹39.4 L Quoted ₹39.5 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹45.2 L+₹5.7 L (14.5%)Rejected-Finance LAMBA LINE PB NO 414 JUNGLIGHAT PO PORT BLAIR A N 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹45.2 L+₹5.7 L (14.5%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹48.1 L+₹8.6 L (21.7%)Rejected-Finance | ₹48.1 L+₹8.6 L (21.7%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹52.4 L+₹12.9 L (32.6%)Rejected-Finance 290 NEW PLOT JAWAHAR NAGAR JAMMU JAMMU JAMMU KASHMIR 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | ₹52.4 L+₹12.9 L (32.6%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹52.4 L+₹12.9 L (32.7%)Rejected-Finance OLD PAHARGAON POLY TECHNIC ROAD DOLLYGUNJ SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹52.4 L+₹12.9 L (32.7%) | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
13 Dec 2022, 6:00 pmClosed
GE Minniebay
Junglighat PO Port Blair Andaman and Nicobar Islands
PROVN OF MASTIC FLOORING AT NGA GODOWN, RETAINING WALL AT VARIOUS PLACES OF AERIAL PARK AT NTS TEYLERABAD AND SPL REP/REPLACEMENT OF 06 NOs 1.5 TR SPLIT AC AGAINST BER AT GE MINNIEBAY,PORT BLAIR
2022_MES_563163_1
8195/E8
Open Tender
Civil Works
Item Rate
180 days
GE Minniebay
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹84,000
Yes
9 Feb 2023
16 Nov 2022
16 Dec 2022
16 Nov 2022
13 Dec 2022
30 Nov 2022
Amount
Surface excavation n.exc 30cm deep and averaging 15 cm deep and getting out in hard / dense soil complete all as specified and as directed by Engr-in-Charge
M&L for broken stone or boulders Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engr-in-Charge
M&L for 75mm thick Cement concrete type C 2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing.even & smoth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for 50mm thick Cement concrete type B 1, 1:2:4 (using 20mm graded stone aggregate) in base of flooring/ hard standing.even & smoth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for providing and laying 25mm thick, Antistatic Bitumastic flooring conforming to IS 13026-1991 for specification and IS 13074-1991 for laying of Bitumastic flooring and having material specification as below: (a) Bitumen (90/15 or 75/15) grade : 13-15% (b) Carborn black of conductive grade like Graphite: 5-7% (c) Stone dust (Clean) : 30% (d) Stone grit (Max 6mm size) : 20% (e) Lime Stone dust (80 to 90% Calcium) : 30%
Taking down chowkats or frames with shutter (without taking off shutters from the frame) n exc 1.5 Sqm each complete all as specified and as directed by Engr-in-Charge.
S & F Anodised Aluminium frames for partitions, doors Windows and Ventilators with one or more rebates incl jointing cleat for fixing etc and aluminium anodised skeleton windows & ventilator shutter fixed with glass or gauge, side hung type without sash bars using standard aluminium section incl necessary jointing cleats, glazing clips, rubber packing anodised aluminium snap beadings screws, anodised aluminium fittings such as handles stainless steel adjustable friction stay hinges etc complete all as specified incl fixing of MS grills / aluminium grill, prelaminated particle boards, glazing to window frame aluminium wire cloth fixed to aluminium frame all as specified and directed by Engineer-in-Charge. NOTE: (i) Payment under this item will be make only for the cost of aluminium section. However unit rate quoted shall deemed to include cost of rubber beading, fittings such as handles, SS friction stay hinges and fixing of 5mm thick glass, prelaminated particle board and grills etc. (ii) Supply only sheet glass,particle board, aluminium wire cloth, MS grills and aluminium grill be measured and paid separately. (iii) Weight of aluminium handle & SS hinges shall not be accounted for payment purpose .
Supply only perforated brass sheet / wire cloth 0.5mm thick with 4mm hole complete all as specified and as directed by Engr-in-Charge
Supply only Aluminium anodised Deco grill DG(102)(10mm in width) weight not less than 3.26 Kg per square metre complete all as specified and as directed by Engr-in-Charge
M&L for pre-cast cement concrete block masonry with solid blocks,Type C1,1:3:6 (20mm graded aggregate) exc 10 cm in width and setting in CM 1:6 complete all as specified and as directed by Engr-in-Charge
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of chalk whiting on plastered surfaces complete all as specified and as directed by Engr-in-Charge
M & L for preparation of old plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed by Engr-in-Charge
M & L for preparing old plastered wall surfaces and applying two coats of acrylic emulsion based premium quality matt finish exterior antifungal paint over a coat of alkali resistant primer all as per manufacturer's instructions complete all as specified and as directed
Dismantling of plain or corrugated steel sheeting, any gauge, thickness in roof covering, etc. including ridge complete all as specified and as directed
S&F 0.50mm thick Pre-Painted Galvatume Aluminium Zinc Coating GI based Corrugated steel sheet of any colour having tensilre strength of 550 MPA yield strength trapezoidal profile as in arch pattern in Roof covering fixed with self tapping screws complete all as manufactures instructions and as directed by Engineer- in -Charge. Note : Overlaping shall be provided as per manufacturer's instructions.
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covring/cladding to wall, fixed with self tapping screws of size 50/75mm and aluminium washer of suitable size complete all as per manufacturers instructions and as directed. Note : Overlaping shall be provided as per manufacturer's instructions.
S & F Aluminium flat , wind ties of any size fixed with self tapping screws of size 40/50mm with integral EPDM washer screwed in roof covering, including all necessary drilling, bolting or riveting etc., and similar work complete all as specified and as directed.
Removing excavated material/soil to a distance exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Excavating over areas not exceeding 1.5m deep and getting out in hard / dense soil complete all as manufactures instructions and as directed by Engineer- in -Charge.
Excavating over areas exceeding 1.5m deep and not exceeding 3m deep an getting out in hard/dense soil complete all as specified and as directed by Engr-in-Charge
M&L for plain cement concrete 1:3:6, Type C2 (nominal mix) using 40 mm graded stone aggregate in foundation, filling and mass concrete complete all as specified and as directed by Engr-in-Charge
M&L for RCC M-30 Design mix using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams etc., and mass concrete complete all as specified and as directed by Engr-in-Charge
M&L for RCC M-30 Design mix using 20mm graded stone aggregate as in retaining walls, basement walls and the like any thickness above top of footing including attached pillasters and butresses complete all as specified and as directed by Engr-in-Charge
M&L formwork to sides of concrete foundation, footings, bases of columns, raft and raft beams, sides and soffits of foundation (if any) and plinth beams for rough finished surfaces of concrete, flat, complete all as specified and as directed by Engr-in-Charge
M&L formwork to faces of walls, retaining/drain walls and similar work including attached pillasters, buttresses etc., vertical or to batter for rough finished surfaces of concrete, flat, complete all as specified and as directed by Engr-in-Charge
M&L for formwork to faces of walls, retaining/drain walls and similar work including attached pillasters, buttresses etc., vertical or to batter for fair finished surfaces of concrete, flat, complete all as specified and as directed by Engr-in-Charge
M&L for TMT bars 10mm dia and over as reinforcement cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by Engr-in-Charge
M&L for boulder filling dry, of broken stones or boulders of gauge 80 to 150mm handpacked tightly behind weep holes complete all as specified and as directed by Engr-in-Charge
M & L for 110 mm dia bore 3 layer PPR SDR 7.4 (PN16) UV stabiized fixed as weep holes in retaining walls complete all as specified and as directed by Engr-in-Charge
M&L for back filling of retaining wall using approved earth obtained from excavation from outside MoD land and spreading in layers n.exc 30cm thick each layer complete all as specified and as directed by Engr-in-Charge
M&L for preparation of new surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and as directed by Engr-in-Charge
M&L for exavation in post holes in hard/ dence soil not exc. 0.5 cum and removing surplus soil to a distance not exc 50 mtr and making good the surface complete all as specified and as directed by Engr-in-Charge
M&L for excavation in trenches not exceeding 1.5M wide and not exceeding 1.5m depth for foundation, etc, and getting out in Hard /dense soil complete all as specified and as directed by Engr-in-Charge
Returning, filling in Hard /dense soil, including, spreading, levelling, watering, and well ramming in layers, not exc 25 cm complete all as specified and as directed by Engr-in-Charge .
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engr-in-Charge
M&L for plain cement concrete type D2 1:4:8 (nominal mix) using 40mm graded granite stone aggregate in foundation filing and mass concrete complete all as specified and as directed by Engr-in-Charge
M&L for mild steel framed work such as posts , railing and fancing work and similar work to conforming to Fe-410-0 or Fe-310.0 complete all as specified and as directed by Engr-in-Charge
M&L for framed work as in door and gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering door etc to be prepared for handing or sliding with and including either hooks and hinges or steel hanging or sliding with or including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and handing also fastening and fixing complete of grade FE-41W (Gde E-250) quality A complete all as specified and as directed by Engr-in-Charge
S&F PVC coated chain link MS galvnized fencing mess of size 50x50mm , having 3mm dia wire with minimum 1mm thick PVC coating [5mm overall dia] complete fixed to any type of standards, rails, straining bolts , etc complete all as specified and as directed by Engr-in-Charge (Note : The supply only of MS flat iron, Rod & MS bolts shall be measured & paid under relevent items of Schedule)
Supply only mild steel bars 10mm dia for support to chain link fencing ccomplete all as specified and as directed by Engr-in-Charge
Supply only flat iron as in fillets for securing wiremess including necessary drilling holes for bolts and welding confirming to Fe-310-0 complete all as specified and as directed by Engr-in-Charge
Supply only screw bolts 10mm dia machine made hexagonal or square head at one end screwed the other or screwed both ends to be fitted with washers & one hexagonal or square not exc 150mm long complete all as specified and as directed by Engr-in-Charge
M&L for prepartion of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engr-in-Charge.
M&L for prepartion of new steel or iron surfaces of any description n.exc 10 cm width or girth and applying two coats of systhetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge
M&L for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of grade FE-410-w (Gde-E250) quality A complete all as specified and as directed by Engr-in-Charge
Supply and Fixing 1.5 TR hi wall mounted split units indoor/outdoor copper tubing in condenser unit including complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality energy efficient complete all as specified and as directed by Engr-in-Charge
S&F 4.0KVA Voltage stablizer for automatic operation single phase naturally air cooled indoor type of designed for input variation between 170V to 250V with output voltage stablized at 230V with accuracy of 2.5% complete all as specified and as directed by Engr-in-Charge
Supply & Fixing of drain outlet PVC 15mm dia connected from rear side of AC upto drain with necessary clamp and fixtures on wall and floor all as specified and as directed.
M&L for submain wiring with two single core PVC insulated multistranded flexible copper conductor 1100Volts grade (FRLSH) cables of 6.0 Sqmm one run of 6.0 Sqmm PVC insulated multistrand copper conductor cable (FRLSH) of green colour for continious earthing drawn through PVC surface/concealed PVC conduit of suitable size and with all accessories including making good to the disturbed wall surface complete all as specified and as directed by Engr-in-Charge Note: Three runs of conductor and and one run of surface/concealed PVC conduit shall be measured as one unit
S&F vertical type of MCCB DB TPN 4 way, IP-43 made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and din rail ,415 Volts with double door . Make : Legrand Cat part No 507751 or equiviland makes in list of makes Note : DB shall be fixed in concealed and making the disturbed surface in good and matching with the existing surface
Supply, fixing, connection and testing MCCB 4Pole 415Volts breaking capacity 16 KA,"C" series of rating 63 Amps complete all as specified and as directed by Engr-in-Charge Make :Legrand Cat part No 420215 or or equiviland makes in list of makes
S &F and testing MCB SP6, 32 Amps, breaking capacity 10kA 'C' series complete all as specified and as directed by Engr-in-Charge
S&F Single pole and neutral enclosure with two pin and earth plug and socket complete with single pole MCB 32 Amps breaking capacity 10kA 'C' series complete all as specified and as directed by Engr-in-Charge
SB ENTERPRISE
SKY GROUP
Allied Trading Company
LOOK UP ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .