Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-Finance CHALITIA BERHAMPORE MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | L1 | Accepted-Finance Lowest Bidder | |
| 2 | L2₹12.3 L+₹11,392 (0.94%)Rejected-Finance 159B M G ROAD HARIDEVPUR KOLKATA WEST BENGAL 700082 UDYAM WB 10 0018308 | KOLKATA | WEST BENGAL | 700082 | L2 | Rejected-Finance 2nd lowest Bidder | |
| 3 | L3₹12.6 L+₹39,990 (3.29%)Rejected-Finance CHOA HARIHARPARA MURSHIDABAD WB 742166 | CHOA | MURSHIDABAD | WEST BENGAL | 742166 | L3 | Rejected-Finance 3rd lowest Bidder | |
| 4 | Rejected-Technical 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | - | Rejected-Technical Due to1) Self Electrical Contractor license of Creative Project not found . (2) Agreement papers and appointment letters of tech person and Supervisor license holder not found |
| Sl No | Description | Qty | Unit | MONDAL ENTERPRISE L2 | G.M.N. ENGINEERING L1 | KHOKAN MONDAL L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent (VDS /EN/ UL / FM / ULC approved) Multi Sensor - Smoke cum Heat detector with ROR features to raise an alarm when the temperature reaches 11.1°per Minute with inbuilt fault isolator with base with Binary coded address setting. Dual LED’s for 360° visibility. Polarity free, Sleek low-profile housing design. Regular 100mm base. IP Rating : IP - 42 with decentralised intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per corresponding standard. (Note : detectors without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) No. of addressable devices in a group will be as per latest recommended Indian/International standards)
(Approved Make: Ravel/ Secutron/ Bosch/ GST/Apollo) | 150 | Each | 3,335 ₹5,00,250 | 3,330 ₹4,99,500 Lowest | 3,350 ₹5,02,500 |
| 2.00 | Supply, Installation,Testing & Commisioning of Analogue Addressable Intelligent Heat Detector (VDS / EN/ UL / FM / ULC approved) (fixed & rate of rise temperature) with twist lockable removal base, built-in fault isolator, etc. including connections as per specifications complete as per NFPA style 7 wiring complete with base and having IP as per corresponding standard (Note : detectors without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) No. of addressable devices in a group will be as per latest recomended Indian/International standards)
(Approved Make: Ravel/ Secutron/ Bosch/ GST/Apollo) | 30 | Each | 3,340 ₹1,00,200 | 3,337 ₹1,00,110 Lowest | 3,350 ₹1,00,500 |
| 3.00 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point (VDS / EN / UL / FM / ULC approved) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Note : devices without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.)
(Approved Make: Ravel/ Secutron/ Bosch/ GST/Apollo) | 4 | Each | 4,175 ₹16,700 | 4,170 ₹16,680 Lowest | 4,180 ₹16,720 |
| 4.00 | Supply, Installation, Testing & Commissioning of Addressable loop / external powered Hooter (sound output of minimum 90db) cum strobe (strength of light 10cd) complete with inbuilt isolator & IP 42 base (VDS /EN / UL / FM / ULC approved) (Note : devices without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for group of addressable devices.)
(Approved Make: Ravel/ Secutron/ Bosch/ GST/Apollo) | 4 | Each | 5,725 ₹22,900 | 5,720 ₹22,880 Lowest | 5,730 ₹22,920 |
| 5.00 | Supply, Installation, Testing & Commissioning of LED type Response Indicator (VDS / EN / UL / FM / ULC approved) including connections etc. complete in all respect.
(Approved Make: Ravel/ Secutron/ Bosch/ GST/Apollo) | 4 | Each | 188 ₹752 | 185 ₹740 Lowest | 190 ₹760 |
| 6.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / KEI / Polycab) with 20mm NB PVC rigid conduit pipe on the surface of the wall. (Make : Precission) | 2,100 | Mtr | 160 ₹3,36,000 | 155 ₹3,25,500 Lowest | 170 ₹3,57,000 |
| 7.00 | Supply ,Installation, Testing and Commissioning of Addressable fully networkable fire alarm control Panel VDS/UL approved suitable for the devices as stated in the previous item of this BOQ along with 20% spear capacity with each loop loading exceeding 80% of the capacity of detectors and devices taken together, loop card which will have 125 / 254 devices of both detectors and modules in a single line circuit on any combination, SLC should supports both Class A and Class B wiring. Shall have an LED indication for FIRE, Normal and Redundancy conditions which consists of display board which will have 160 Character Display with Touch key pad, Mother board which will have ARM CORTEX M3 32 Bit Processor, Inbuilt RS-485 Networking Circuit for peer to peer networking, Inbuilt USB 2.0 Port for upload and download the Configuration tools, Two inbuilt programmable inputs, Two inbuilt NAC's, and Three Programmable Relays. power Supply Board, having minimum 1000 event memory, which will have SMPS fully protected board, which its operates on 120 to 220V AC ± 10% with 50/60 Hz, battery backup 24V DC with built-in charger. the panel have IP-50 rating complete as required and as per specification.
(Approved Make: Ravel/ Secutron/ Bosch/ GST/Apollo) | 1 | Each | 2,50,000 ₹2,50,000 Lowest | 2,50,000 ₹2,50,000 Lowest | 2,55,000 ₹2,55,000 |
| 7.01NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) Standards, (ii) IS 2189 , (iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand. | ||||||
| 7.02TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done. | ||||||
| 7.03TERMS & CONDITIONS :- | ||||||
Tender Value
Refer Docs
EMD Value
₹24,332
Closing Date
10 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SENIOR SUPERINTENDING ENGINEER
GOVERNMENT OF WEST BENGAL OFFICE OF THE SENIOR SUPERINTENDING ENGINEER (P.W.Dte) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Construction of proposed 50 bedded hospital building at Digha SG Hospital SITC of FDA System.
2025_WBPWD_894582_1
WBPWD/SSE/SWEC/NIQ34/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
PURBA MEDINIPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹24,332
OFFICE OF THE SENIOR SUPERINTENDING ENGINEER
13 Aug 2026
25 Aug 2025
12 Sept 2025
25 Aug 2025
10 Sept 2025
29 Aug 2025
28 Aug 2025
Amount
Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent (VDS /EN/ UL / FM / ULC approved) Multi Sensor - Smoke cum Heat detector with ROR features to raise an alarm when the temperature reaches 11.1°per Minute with inbuilt fault isolator with base with Binary coded address setting. Dual LED’s for 360° visibility. Polarity free, Sleek low-profile housing design. Regular 100mm base. IP Rating : IP - 42 with decentralised intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per corresponding standard. (Note : detectors without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) No. of addressable devices in a group will be as per latest recommended Indian/International standards) (Approved Make: Ravel/ Secutron/ Bosch/ GST/Apollo)
Supply, Installation,Testing & Commisioning of Analogue Addressable Intelligent Heat Detector (VDS / EN/ UL / FM / ULC approved) (fixed & rate of rise temperature) with twist lockable removal base, built-in fault isolator, etc. including connections as per specifications complete as per NFPA style 7 wiring complete with base and having IP as per corresponding standard (Note : detectors without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) No. of addressable devices in a group will be as per latest recomended Indian/International standards) (Approved Make: Ravel/ Secutron/ Bosch/ GST/Apollo)
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point (VDS / EN / UL / FM / ULC approved) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Note : devices without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) (Approved Make: Ravel/ Secutron/ Bosch/ GST/Apollo)
Supply, Installation, Testing & Commissioning of Addressable loop / external powered Hooter (sound output of minimum 90db) cum strobe (strength of light 10cd) complete with inbuilt isolator & IP 42 base (VDS /EN / UL / FM / ULC approved) (Note : devices without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for group of addressable devices.) (Approved Make: Ravel/ Secutron/ Bosch/ GST/Apollo)
Supply, Installation, Testing & Commissioning of LED type Response Indicator (VDS / EN / UL / FM / ULC approved) including connections etc. complete in all respect. (Approved Make: Ravel/ Secutron/ Bosch/ GST/Apollo)
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / KEI / Polycab) with 20mm NB PVC rigid conduit pipe on the surface of the wall. (Make : Precission)
Supply ,Installation, Testing and Commissioning of Addressable fully networkable fire alarm control Panel VDS/UL approved suitable for the devices as stated in the previous item of this BOQ along with 20% spear capacity with each loop loading exceeding 80% of the capacity of detectors and devices taken together, loop card which will have 125 / 254 devices of both detectors and modules in a single line circuit on any combination, SLC should supports both Class A and Class B wiring. Shall have an LED indication for FIRE, Normal and Redundancy conditions which consists of display board which will have 160 Character Display with Touch key pad, Mother board which will have ARM CORTEX M3 32 Bit Processor, Inbuilt RS-485 Networking Circuit for peer to peer networking, Inbuilt USB 2.0 Port for upload and download the Configuration tools, Two inbuilt programmable inputs, Two inbuilt NAC's, and Three Programmable Relays. power Supply Board, having minimum 1000 event memory, which will have SMPS fully protected board, which its operates on 120 to 220V AC ± 10% with 50/60 Hz, battery backup 24V DC with built-in charger. the panel have IP-50 rating complete as required and as per specification. (Approved Make: Ravel/ Secutron/ Bosch/ GST/Apollo)
NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) Standards, (ii) IS 2189 , (iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand.
TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done.
TERMS & CONDITIONS :-
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
MONDAL ENTERPRISE (BID ID -6918651)
KHOKAN MONDAL (BID ID -6918855)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
cancelled_1.pdf
pdf • 1.92 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tendernotice_2.pdf
PDF • 1.81 MB
BOQ_2017460.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .