Supply installation testing and commissioning of 02 x 125 KVA DG Set with other allied equipments at Jumagund under UT Capex Budget
2021_PDD_143820_1
e-NIT 49 of 2021-22
Open Tender
Electrical Works
Lump-sum
30 days
Office of the Executive Engineer ED kupwara
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,100
Yes
Executive Engineer ED kupwara
₹1.5 L
Yes
25 Oct 2021
13 Oct 2021
25 Oct 2021
13 Oct 2021
23 Oct 2021
13 Oct 2021
Amount
SITC of silent type 125 KVA DG set , 3 Phase 415V,50Hz,1500RPM,6 Cylinder Turbo charger 12 V DC, with Power Smart micro based monitoring and series 600, Self starting system with Battery charging alternator 12V DC including Earthing, cabling & assembling at site complete job. (Job includes Carriage up to site, loading , unloading using mechanical means at site) Spares to be supplied with Generator:- 1. Air filter with Gas kits complete:_ 4 No 2. Engineer Oil filter with gas kits:- 4No 3.HSD filter completer:- 2NO 4.Engine Oil in sealed containers for:- 4 Services
Supply ,Installation ,Testing & Commissioning of single core 300 mm2 ,3 Layer, xlpe insulated, un-armoured ,FRLS cable 650/11000 grade as per IS 7098(part 1) 1988 with up to date amendments including cable termination kits where ever required ( the cable may be cut in suitable lengths as per site requirement and each length should be fitted with cable termination kits on both side )
SITC of 11 kV VCB Panel Board (12 kV, 1250A, 25 KA, indoor) with O/C, E/F relays (IEC61850, mimic diagram, volt meter, ammeter, annunciation windows with annunciation relay, 3 phase tri-vector meter-5Amp, Dlms compliant with RS-485 port Incomer including panel spares to be provided with panel as under:- 1. Interrupter Set:- 1SET 2. Numerical relay:- 1No 3. Master trip relay:- 1No 4. Closing and opening coils:- 5No Each
SITC of DG Synchronizing Panel with power source of 415VAC, 3 Phase, 50Hz with capacity of 250KVA suitable for 02 No. of 125KVA DG Sets, along with all cable and accessories
SITC of 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type
SITC of 11 KV 120mm2 single- Core XLPE cable (with one spare length) armoured, FRLS
SITC of 11 kV Outdoor Heat Shrinkable Cable Termination Kits
SITC of 11 kV Indoor Heat Shrinkable Cable Termination Kits
SITC of 11 kV Isolator, double break,3-pole, 600Amp, horizontal mounting Type, with Earth Switch.
SITC of 9 Mtr. Long Pole(ST-410 SP33)
SITC of Galvanised iron of sorts
SITC of 250 KVA,11/0.433KV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound)
SITC of 120 mm² PVC LT Cable 4 Core, armoured, FRLS
SITC of Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole
SITC works for Earthing of 250 KVA substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonry with RCC slab cover.
SITC works for Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI strip
SITC of MCCB ‐ 180 Amps with LED phase indicators enclosed in metal coated box CRCA thickness not less than 2mm out door type 3Phase 4 wire All complete
S/L of HDPE Pipe out dia 180mm inner dia 152mm for laying of LT / HT Cables
S/L of 11KV Horn gap DOF set heavy duty
S/L of conductor and hardware fittings of sorts required for 250KVA Sub. Station
SITC of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
SITC of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Shakels with mukkin Clamps
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
P/L of chemical earthing at Different locations and connecting all earthing pits with each other using 50*8mm GI flat and 10 FT long electrode for chemical earthing pits and earthing material complete in all respects as per REC Standard
SITC of a). Battery Bank 36 V,180 AH , of 18 No. cells of 2 V each, sealed maintenance free VRLA type, High impact Polyprophelene copolymer container, flame retardant. b). 36v,180 AH , Float‐Cum‐Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply .
P/L of Cable Trench for laying of 11 kV XLPE / control Cables in the out door yard with cover plates of RCC or chequer plates (6mm Thick) (the Design / drawing / reinforcement / concrete mix will be as per standards adopted by depth under REC / PMDP/DDUGJY)
Providing of Rubber Mat 1mx2m 19mm thick
M/S AZAD ASSOCIATES
M D ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .