Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC 1 VILLAGE JYOTISAR DISTT KURUKSHETRA | KURUKSHETRA | HARYANA | 136030 | ₹2.4 Cr Quoted ₹2.5 Cr | L1 | Accepted-AOC awarded |
| 2 | L2₹2.7 Cr+₹22.3 L (9.02%)Rejected-Finance 14 CHAHAR CONSTRUCTION CO ADARSH NAGAR NEAR ROHILLA COMMUNICAION 124103 | JHAJJAR | HARYANA | 124103 | ₹2.7 Cr+₹22.3 L (9.02%) | L2 | Rejected-Finance L2 |
| 3 | L3₹2.7 Cr+₹26.2 L (10.6%)Rejected-Finance | ₹2.7 Cr+₹26.2 L (10.6%) | L3 | Rejected-Finance L3 |
| 4 | L4₹3.0 Cr+₹56.1 L (22.7%)Rejected-Finance 1804 SECTOR 2 HUDA 124001 | ROHTAK | HARYANA | 124001 | ₹3.0 Cr+₹56.1 L (22.7%) | L4 | Rejected-Finance L4 |
Tender Value
₹2.2 Cr
EMD Value
₹4.5 L
Closing Date
26 Aug 2020, 5:00 pmClosed
Executive Engineer-IV, W/S Division, GMDA
O/o Executive Engineer-IV, W/S Division, GMDA, Plot No.3, Sector-44, Gurugram
Repair and Maintenance of mechanical, electrical works, repair of rising main and appurtenants at Boosting Station Sector-16, 51 and Online Booster near Paras Hospital, Gurugram including all other works contingent thereto
2020_HRY_138647_1
Job No.12/2020 W/S Division (Re-called)
Open Tender
Civil Works
Works
540 days
Gurugram
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
GMDA
₹4.5 L
6 Oct 2020
6 Aug 2020
27 Aug 2020
6 Aug 2020
26 Aug 2020
6 Aug 2020
Amount
(Part-B-I) NS Repair of Horizontal, Slip-ring, Non slip-ring & pumping sets consisting mainly of motor, pump,ACBs, electrical control panel, starter, cable and all accessories like sluice valves, non-return valves specials etc. including all appurtenances inside premises & making record at BS Gurugram complete in all respects and all other works contingent thereto. (For Boosting Station at Sector 16)
i) I. 0 to 20 BHP
iii) Above 100 BHP
NS Repair of accessories, repair / leakage of sluice valve/ non return valve,Air-Valve, repair of specials , electrical & mechanical components ,etc. at the premises of Boosting Station & in ZONE-II of Master water supply scheme of GMDA,Gurgugram as per DNIT. (For Boosting Station at Sector 16)
NS Repair and maintenance of HT/LT installations, DG sets, VCBs, ACB, Conductor, XPLE cable, GO Switch, electric poles, insulators etc. from DHBVN Meter to unit of BS complete in all respects (For Boosting Station at Sector 16)
NS Dehydration of transformer oil as per specification mentioned in the manual of operation and maintenance as per DNIT. (For Boosting Station at Sector 16)
NS Refilling of transformer oil of required grade as per manufacturer’s manual as and when required. (For Boosting Station at Sector 16)
NS Special repair of transformere (conventional type) of 1250 KVA capacity including rewinding toward HT/LT side breather and silica gel and all other item required to make functional the transformer complete in all respect. (For Boosting Station at Sector 16)
NS Repair and maintenance of Electrical fittings such as mast light, Electrical fans, Flood light, tube light etc. within boundary of water works from 0 to 1 BHP within boundary wall of water works. (For Boosting Station at Sector 16)
NS Repairing of leakaged socketted joints & specials of CI/DI pipeline including excavation of earth dewatering/bailing out pipeline water, execution of work and all other T&P required complete in all respect as per satisfaction of the engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him (without pig lead, which will be paid extra as per actual consumption). (For Boosting Station at Sector 16)
I. For 150/200/250 mm i/d pipe line
II. For 300/350 mm i/d pipe line
III. For 400/450 mm i/d pipe line
IV. For 500 mm i/d pipe line
V. For 600 mm i/d pipe line
VI. For 700mm i/d pipe line
VII. For 800mm i/d pipe line
VIII. For 900mm i/d pipe line
NS Providing & Fixing of MS flat ring/clamp of size 75x12mm around the pipe of water supply line of different size for repair of leakage of pipeline as per the site requirement including rivets, screws, nuts & bolts, washer and rubber sheet for packing etc. including excavation ,dewatering and all other works as per site reuirements. complete in all respect and as per satisfaction of Engineer in charge. (For Boosting Station at Sector 16) MS Flat - 75x12mm Size Rubber sheet - 10mm thick x 300mm width Nuts and bolt of dia 12 mm & 300 mm minimum length
I. For 200 mm to 450mm i/d pipe line
II. For 500 mm to 600mm i/d pipe line
III. For 700 mm to 800mm i/d pipe line
IV. For 900 mm to 1000mm i/d pipe line
NS Providing & Fixing of MS flat ring/clamp of size 300x12mm around the pipe of water supply line of different size for repair of leakage of pipeline as per the site requirement including rivets, screws, nuts & bolts, washer and rubber sheet for packing etc. including excavation ,dewatering and all other works as per site reuirements complete in all respect and as per satisfaction of Engineer in charge. (For Boosting Station at Sector 16) MS Flat - 300x12mm Size Rubber sheet - 10mm thick x 300mm width Nuts and bolt of dia 12 mm & 300 mm minimum length
I. For 200 mm to 450mm i/d pipe line
II. For 500 mm to 600mm i/d pipe line
III. For 700 mm to 800mm i/d pipe line
IV. For 900 mm to 1000mm i/d pipe line
NS Repairing of leakaged joints of MS pipe by welding in existing running line including excavation of earth dewatering/bailing out pipe line water, execution of work and all other T&P required complete in all respect as per satisfaction of the Engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him. (For Boosting Station at Sector 16)
I. For 1300/1200 mm i/d pipe line
II. For 1000/900 mm i/d pipe line
III. For 800/700 mm i/d pipe line
NS Repairing of leakage of burst CI/ DI pipe line with new Pipe (pipe to be Supplied by Dept.) by fixing mechanical joint collar as per IS Standared including excavation of earth dewatering/bailing out pipe line water, execution of work and all other T&P complete in all respect as per satisfaction of the Engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him. (For Boosting Station at Sector 16)
i) For 150 mm i/d pipe line
ii) For 200 mm i/d pipe line
iii) For 250 mm i/d pipe line
iv) For 300 mm i/d pipe line
v) For 350 mm i/d pipe line
vi) For 400 mm i/d pipe line
vii) For 450 mm i/d pipe line
viii) For 500 mm i/d pipe line
ix) For 600 mm i/d pipe line
x) For 700mm i/d pipe line
xi) For 900mm i/d pipe line
NS Supplying and placing of pig lead in melted form into leakaged socketted joints including fuel wood for heating pig lead including all the taxes and its caulking so as to tighten the joint in CI/DI pipeline of any size. (For Boosting Station at Sector 16)
NS Disconnection of Illegal/unauthorized connections or defaulters (unpaid bills of Water Supply) including plugging of connection pipeline,labour, socket pipe, JCB/hydra, Dewatering pump etc. in Gurugram complete in all respect as per complete satisfaction of Engineer in Charge and all other works contingent thereto. (All Sizes of connections). (For Boosting Station Sector 16)
NS Supply, Installation, Testing & commissioning of LED type Street Light fitting 90W IP 66 pressure die cast housing with toughned glass and individual High Power LEDs with Surge protection Device, operation 230 V AC Supply to be mount on existing octagonal pole in all respect i/c necessary connections make Havells, Bajaj, Cromption, Philips, GE, Halonix. (For Boosting Station at Sector 16)
NS Proving and fixing of maintenance free 150-200 Ah 12 V Battery or of sufficient power with 36 Months on-site warranty for running 600 KVA DGs of reputed make such as UTL, Amaron,Luminous,Microtech,Sukam,Exide complete in all respect as per satisfaction of Engineer in Charge (Credit of old battery also included). (For Boosting Station at Sector 16) To be fixed in 15 days of allotment.
NS Proving and fixing 12V/24V Digital Automatic Battery charger of reputed make conforming to BIS Specifications complete in all respect as per satisfaction of Engineer in Charge. (For Boosting Station at Sector 16) To be fixed in 15 days of allotment.
NS Providing and fixing of Pressure Gauge on motor delivery lines and all Rising Mains emanating from Boosting station of reputed make conforming to BIS Specifications including cost of installation , GI Pipes , etc and all other items required for fixing on lines as per site conditions complete in all respect as per satisfaction of Engineer in charge. (For Boosting Station at Sector 16) To be fixed in 15 days of allotment.
NS Providing and fixing of Insertion type Flow Meter with RTU on Rising Mains eminating from Boosting Stations of reputed make conforming to BIS Specifications of size 600mm to1000mm i/d including cost of installation, all fittings/Items necessary for fixing as per site conditions complete in all respect with satisfaction of Engineer in Charge of make such as Tallis, AUK, Krone Marshall, ABB, Omega, Kobold. (For Boosting Station at Sector 16) To be fixed in 15 days of allotment. (Defect liability Period of 2 years free of cost).
Part-B-II) NS Repair of Horizontal, Slip-ring, Non slip-ring & pumping sets consisting mainly of motor, pump,ACBs, electrical control panel, starter, cable and all accessories like sluice valves, non-return valves specials etc. including all appurtenances inside premises & making record at BS Gurugram complete in all respects and all other works contingent thereto. (For Boosting Station at Sector 51)
i) 0 to 20 BHP
ii) 20 to 100 BHP
iii) Above 100 BHP
NS Repair of accessories, repair / leakage of sluice valve/ non return valve,Air-Valve, repair of specials , electrical & mechanical components ,etc. at the premises of Boosting Station & in ZONE-III of Master water supply scheme of GMDA,Gurgugram as per DNIT. (For Boosting Station at Sector 51) 1 Nos BS and Online Boooster at Paras.
NS Repair and maintenance of HT/LT installations, DG sets, VCBs, ACB, Conductor, XPLE cable, GO Switch, electric poles, insulators etc. from DHBVN Meter to unit of BS complete in all respects. (For Boosting Station at Sector 51) 1 Nos BS and Online Boooster at Paras.
NS Dehydration of transformer oil as per specification mentioned in the manual of operation and maintenance as per DNIT. (For Boosting Station at Sector 51)
NS Refilling of transformer oil of required grade as per manufacturer’s manual as and when required. (For Boosting Station at Sector 51)
NS Special repair of transformere (conventional type) of 630 KVA capacity including rewinding toward HT/LT side breather and silica gel and all other item required to make functional the transformer complete in all respect. (For Boosting Station at Sector 51)
NS Repair and maintenance of Electrical fittings such as mast light, Electrical fans, Flood light, tube light etc. within boundary of water works from 0 to 1 BHP within boundary wall of water works. (For Boosting Station at Sector 51)
Repairing of leakaged socketted joints & specials of CI/DI pipeline including excavation of earth dewatering/bailing out pipeline water, execution of work and all other T&P required complete in all respect as per satisfaction of the engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him (without pig lead, which will be paid extra as per actual consumption) (For Boosting Station at Sector 51)
i) For 150/200/250 mm i/d pipe line
ii) For 300/350 mm i/d pipe line
iii) For 400/450 mm i/d pipe line
iv) For 500 mm i/d pipe line
v) For 600 mm i/d pipe line
vi) For 700mm i/d pipe line
vii) For 800mm i/d pipe line
viii) For 900mm i/d pipe line
viii) For 1000mm i/d pipe line
NS Providing & Fixing of MS flat ring/clamp of size 75x12mm around the pipe of water supply line of different size for repair of leakage of pipeline as per the site requirement including rivets, screws, nuts & bolts, washer and rubber sheet for packing etc. including excavation ,dewatering and all other works as per site reuirements. complete in all respect and as per satisfaction of Engineer in charge. (For Boosting Station at Sector 51) MS Flat - 75x12mm Size Rubber sheet - 10mm thick x 300mm width Nuts and bolt of dia 12 mm & 300 mm minimum length
I. For 200 mm to 450mm i/d pipe line
II. For 500 mm to 600mm i/d pipe line
III. For 700 mm to 800mm i/d pipe line
IV. For 900 mm to 1000mm i/d pipe line
NS Providing & Fixing of MS flat ring/clamp of size 300x12mm around the pipe of water supply line of different size for repair of leakage of pipeline as per the site requirement including rivets, screws, nuts & bolts, washer and rubber sheet for packing etc. including excavation ,dewatering and all other works as per site reuirements complete in all respect and as per satisfaction of Engineer in charge. (For Boosting Station at Sector 51) MS Flat - 300x12mm Size Rubber sheet - 10mm thick x 300mm width Nuts and bolt of dia 12 mm & 300 mm minimum length
I. For 200 mm to 450mm i/d pipe line
II. For 500 mm to 600mm i/d pipe line
III. For 700 mm to 800mm i/d pipe line
IV. For 900 mm to 1000mm i/d pipe line
NS Repairing of leakaged joints of MS pipe by welding in existing running line including excavation of earth dewatering/bailing out pipe line water, execution of work and all other T&P required complete in all respect as per satisfaction of the Engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him. (For Boosting Station at Sector 51)
I. For 1300/1200 mm i/d pipe line
II. For 1000/900 mm i/d pipe line
III. For 800/700 mm i/d pipe line
NS Repairing of leakage of burst CI/ DI pipe line with new Pipe (pipe to be Supplied by Dept.) by fixing mechanical joint collar as per IS Standared including excavation of earth dewatering/bailing out pipe line water, execution of work and all other T&P complete in all respect as per satisfaction of the Engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him.
i) For 150 mm i/d pipe line
ii) For 200 mm i/d pipe line
iii) For 250 mm i/d pipe line
iv) For 300 mm i/d pipe line
v) For 350 mm i/d pipe line
vi) For 400 mm i/d pipe line
vii) For 450 mm i/d pipe line
viii) For 500 mm i/d pipe line
ix) For 600 mm i/d pipe line
x) For 700mm i/d pipe line
xi) For 800mm i/d pipe line
xii) For 900mm i/d pipe line
xiii) For 1000mm i/d pipe line
NS Supplying and placing of pig lead in melted form into leakaged socketted joints including fuel wood for heating pig lead including all the taxes and its caulking so as to tighten the joint in CI/DI pipeline of any size. (For Boosting Station at Sector 51)
NS Disconnection of Illegal/unauthorized connections or defaulters (unpaid bills of Water Supply) including plugging of connection pipeline,labour, socket pipe, JCB/hydra, Dewatering pump etc. in Gurugram complete in all respect as per complete satisfaction of Engineer in Charge and all other works contingent thereto. (All Sizes of connections). (For Boosting Station at Sector 51)
NS Supply, Installation, Testing & commissioning of LED type Street Light fitting 90W IP 66 pressure die cast housing with toughned glass and individual High Power LEDs with Surge protection Device, operation 230 V AC Supply to be mount on existing octagonal pole in all respect i/c necessary connections make Havells, Bajaj, Cromption, Philips, GE, Halonix. (For Boosting Station at Sector 51)
NS Proving and fixing of maintenance free 150-200 Ah 12 V Battery or of sufficient power with 36 Months on-site warranty for running 600 KVA DGs of reputed make such as UTL, Amaron,Luminous,Microtech,Sukam,Exide complete in all respect as per satisfaction of Engineer in Charge (Credit of old battery also included). (For Boosting Station at Sector 51) To be fixed in 15 days of allotment.
NS Proving and fixing 12V/24V Digital Automatic Battery charger of reputed make conforming to BIS Specifications complete in all respect as per satisfaction of Engineer in Charge. (For Boosting Station at Sector 51) To be fixed in 15 days of allotment.
NS Providing and fixing of Pressure Gauge on motor delivery lines and all Rising Mains emanating from Boosting station of reputed make conforming to BIS Specifications including cost of installation, GI Pipes, etc and all other items required for fixing on lines as per site conditions complete in all respect as per satisfaction of Engineer in charge. (For Boosting Station at Sector 51) To be fixed in 15 days of allotment.
NS Providing and fixing of Insertion Type Flow Meter with RTU on Rising Mains eminating from Boosting Stations of reputed make conforming to BIS Specifications of size 600mm to1000mm i/d including cost of installation, all fittings/Items necessary for fixing as per site conditions complete in all respect with satisfaction of Engineer in Charge of make such as Tallis, AUK, Krone Marshall, ABB, Omega, Kobold. To be fixed in 15 days of allotment. (For Boosting Station at Sector 51) (Defect liability Period of 2 years free of cost).
Bidder Name
Amount
Rajesh Kumar
Narender Singh Contractor
yudhvir singh
Chahar Construction Co
Chahar Construction Co
yudhvir singh
Narender Singh Contractor
yudhvir singh
Chahar Construction Co
Narender Singh Contractor
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .