| 1 | L1₹38.6 LAccepted-AOC | ₹38.6 L | L1 | Accepted-AOC Lowest tenderer |
| 2 | L2₹42.1 L+₹3.5 L (9.01%)Rejected-Finance 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | ₹42.1 L+₹3.5 L (9.01%) | L2 | Rejected-Finance Other than lowest tenderer |
| 3 | L3₹43.9 L+₹5.3 L (13.6%)Rejected-Finance | ₹43.9 L+₹5.3 L (13.6%) | L3 | Rejected-Finance Other than lowest tenderer |
| 4 | L4₹45.2 L+₹6.6 L (17.1%)Rejected-Finance | ₹45.2 L+₹6.6 L (17.1%) | L4 | Rejected-Finance Other than lowest tenderer |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected being uenlisted firm and not compliance instruction mentioned in NIT Serial No. 8 (b) (v) and not uploaded requisite documents for un-enlisted contractor as per Para 1.5 of Manual on contracts 2020 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
9 Apr 2024, 6:00 pmClosed
Vipin Chandra Rai
GE UTILITY BATHINDA
REPAIR/MAINTENANCE TO VARIOUS TYPES OF ELECTRIC MOTOR AND PUMPING SETS, SUBMERSIBLE PUMPS AT WATER SUPPLY INSTALLATIONS WITH CONNECTED ITEMS AND MISCELLANIOUS WORKS UNDER GE (U) BATHINDA...
2023_MES_630002_2
8760/2023-24/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda
Class D cat b i
9 documents required · 9 mandatory
₹500
Garrison Engineer (U) Bathinda
₹1 L
Yes
3 Jun 2024
19 Mar 2024
11 Apr 2024
19 Mar 2024
9 Apr 2024
26 Mar 2024
Amount
Dismantling the electric induction motor AC 3 Phase, capacity 60 HP to 125 HP, 440 V, 1440 RPM, 50 Cycle of any make and type from the foundation and pump after disconnecting electric cable connection and earthing etc. and transportation to civil workshop for repair/rewinding, strip opening the motor and removing of defective burnt winding, rewinding the motor after cleaning the rotor and starter with super enameled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing all high grade material and class ‘B’ varnish for insulation, reassembling the complete motor and re-fixing at site with electric cable connection, earthing and testing the motor on full load at site after coupling the pump for its serviceability up to entire satisfaction of Engineer-in-charge. Note :- (i) Super enameled copper winding wire shall be measured and paid separately under appropriate item of this BOQ as supply only. (ii) Ball bearing and other spares if replaced shall be measured and paid separately under appropriate item of this BOQ as supply only. (iii) The T & P/vehicles shall be arranged by the contractor and the cost deemed to be included in his quoted rates.
All as per srl item No. 01 here-in-before but electric motor of capacity 15 HP to 50 HP.
All as per srl item No. 01 here-in-before but electric motor of capacity 6 HP to 12.5 HP.
All as per srl item No. 01 here-in-before but electric motor of capacity up to 5 HP.
Disconnecting the pumping sets of capacity 60 HP to 125 HP any make and model from motor and all water connections and removing/taking up from foundation, taking to civil workshop for repair/strip opening and repairing of pumping sets by changing the defective/unserviceable parts such as bearing, shaft, impeller, bush, Gland plate etc. complete. Reassembling including oiling, greasing replacement of worn out nuts, bolts, gasket, glands etc and re-fixing in its original position at site, making all connections, commissioning and testing complete all as directed by Engineer-in-Charge. Note :- (i). Ball bearing, shaft, impeller, bush, Gland plate & stuffing box packing and other spares replaced as per requirement shall be measured and paid separately under appropriate item of this BOQ as supply only. (ii) The rates for minor repair, all other minor items essential for functioning of pump shall deemed to be included in the quoted rates. (iii) The T & P/ vehicles shall be arranged by the contractor and the cost deemed to be included in his quoted rates.
All as per srl item No. 05 here-in-before but pumping sets of capacity 15 HP to 50 HP.
All as per srl item No. 05 here-in-before but pumping set of capacity 6 HP to 12.5 HP.
All as per srl item No. 05 here-in-before but electric motor of capacity up to 5 HP.
Lifting the defective open well submersible pumping set of capacity upto 12.5 HP complete after disconnecting electric cable connection and transportation to civil workshop and back for repair and rewinding of open well submersible electric motor upto 12.5 HP by using PVC insulated copper conductor winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing all high grade material and class ‘B’ varnish for insulation and carrying out the repairs of pump like replacement of bushes and other minor reapirs and reassembling the submersible motor pump, lowering including reconnecting the electric cable connection and testing complete all as directed by Engineer-in-Charge. Note :- (i) The rates for minor repair, jointing and jointing materials are deemed to be included in the quoted rates (ii) The cost of Rewinding of motor is deemed to be included in the rate quated.
Lifting the defective bore well submersible pumping set of capacity upto 5 HP complete after disconnecting electric cable connection and transportation to civil workshop and back for repair and rewinding of bore well submersible electric motor upto 5 HP by using PVC insulated copper conductor winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing all high grade material and class ‘B’ varnish for insulation, reassembling the complete submersible motor pump, lowering including reconnecting the electric cable connection and testing complete all as directed by Engineer-in-Charge. Note :- (i) The rates for minor repair, jointing and jointing materials shall deem to be included in the quoted rates (ii) Super enameled copper winding wire shall be measured and paid separately under appropriate item of this BOQ as supply only.
All as per srl item No. 10 here-in-before but bore well submersible pumping set of capacity 6 HP to 12.5 HP.
All as per srl item No. 10 here-in-before but bore well submersible pumping set of capacity 15 HP to 30 HP.
Supply only ball bearing No. 6316 for electric motor/ pump complete all as directed by Engineer-in-charge.
Supply only ball bearing No. 6314 for electric motor/ pump complete all as directed by Engineer-in-charge.
Supply only ball bearing No. 6313 for electric motor/ pump complete all as directed by Engineer-in-charge.
Supply only ball bearing No. 6308 for electric motor/ pump complete all as directed by Engineer-in-charge.
Supply only ball bearing No. 6305 for electric motor/ pump complete all as directed by Engineer-in-charge.
Supply only ball bearing No. 6306 for electric motor/ pump complete all as directed by Engineer-in-charge.
Supply only ball bearing No. 6307 for electric motor/ pump complete all as directed by Engineer-in-charge.
Supply only ball bearing No. 6310 for electric motor/ pump complete all as directed by Engineer-in-charge.
Supply only ball bearing No. 6206 for electric motor/ pump complete all as directed by Engineer-in-charge.
Supply only ball bearing No. 6205 for electric motor/ pump complete all as directed by Engineer-in-charge
Supply only ball bearing No. 6309 for electric motor/ pump complete all as directed by Engineer-in-charge.
Supply only steel distance pieces suitable for 60 HP to 125 HP pumping set of any make complete all as directed by Engineer-in-charge.
Supply only steel distance pieces suitable for 15 HP to 50 HP pumping set of any make complete all as directed by Engineer-in-charge.
Supply only steel distance pieces suitable for 6 HP to 12.5 HP pumping set any make complete all as directed by Engineer-in-charge.
Supply only steel distance pieces suitable for up to 5 HP pumping set of any make complete all as directed by Engineer-in-charge.
Supply only gland plate studs/ eye bolt suitable for 60 HP to 125 HP pumping set of any make complete all as directed by Engineer-in-charge.
Supply only gland plate studs/ eye bolt suitable for 15 HP to 50 HP pumping set of any make complete all as directed by Engineer-in-charge.
Supply only gland plate studs/ eye bolt suitable for 6 HP to 12.5 HP pumping set of any make complete all as directed by Engineer-in-charge.
Supply only gland plate studs/ eye bolt suitable for up to 5 HP pumping set of any make complete all as directed by Engineer-in-charge.
Supply only carbon steel shaft high tensile strength with key suitable for pump set of capacity 60 HP to 125 HP of any make complete all as directed by Engineer-in-charge.
Supply only carbon steel shaft high tensile strength with key suitable for pump set of capacity 15 HP to 50 HP of any make complete all as directed by Engineer-in-charge.
Supply only carbon steel shaft high tensile strength with key suitable for pump set of capacity 6 HP to 12.5 HP of any make complete all as directed by Engineer-in-charge.
Supply only carbon steel shaft high tensile strength with key suitable for pump set of capacity up to 5 HP of any make complete all as directed by Engineer-in-charge.
Supply only cast iron impeller suitable for pump set of capacity 60 HP to 125 HP of any make complete all as directed by Engineer-in-charge.
Supply only cast iron impeller suitable for pump set of capacity 15 HP to 50 HP of any make complete all as directed by Engineer-in-charge.
Supply only cast iron impeller suitable for pump set of capacity 6 HP to 12.5 HP of any make complete all as directed by Engineer-in-charge.
Supply only cast iron impeller suitable for pump set of capacity up to 5 HP of any make complete all as directed by Engineer-in-charge.
Supply only brass/gun metal bush DE & NDE suitable for pump set of capacity 60 HP to 120 HP of any make complete all as directed by Engineer-in-charge.
Supply only brass/gun metal bush DE & NDE suitable for pump set of capacity 15 HP to 50 HP of any make complete all as directed by Engineer-in-charge.
Supply only brass/gun metal bush DE & NDE suitable for pump set of capacity 6 HP to 12.5 HP of any make complete all as directed by Engineer-in-charge.
Supply only brass/gun metal bush DE & NDE suitable for pump set of capacity up to 5 HP of any make complete all as directed by Engineer-in-charge.
Supply only bushes for open well type submersible pumping set of capacity upto 12.5 HP complete all as directed by Engineer-in-charge.
Supply only bushes for bore well submersible pumping set of capacity upto 5 HP complete all as directed by Engineer-in-charge.
Supply only bushes for bore well submersible pumping set of capacity 6 HP to 12.5 HP complete all as directed by Engineer-in-charge.
Supply only bushes for bore well submersible pumping set of capacity 15 HP to 30 HP complete all as directed by Engineer-in-charge.
Supply only super enameled copper winding wire for rewinding the electric motors as per existing grade and size complete all as directed by Engineer-in-charge. .
Supply and fixing in replacement power contactor 415 volt, 50 cycles, 3 phase, type ML-6 complete all as directed by Engineer-in-charge.
Supply and fixing in replacement power contactor 415 volt, 50 cycles, 3 phase, type ML-4 complete all as directed by Engineer-in-charge.
Supply and fixing in replacement power contactor 415 volt, 50 cycles, 3 phase, type ML-3 complete all as directed by Engineer-in-charge.
Supply and fixing in replacement power contactor 415 volt, 50 cycles, 3 phase, type MNX 80 complete all as directed by Engineer-in-charge.
Supply and fixing in replacement power contactor 415 volt, 50 cycles, 3 phase, type MNX 70 complete all as directed by Engineer-in-charge.
Supply and fixing in replacement power contactor 415 volt, 50 cycles, 3 phase, type AX-18-30-10 complete all as directed by Engineer-in-charge.
Supply and fixing in replacement power contactor 415 volt, 50 cycles, 3 phase, type AX-40-30-10 complete all as directed by Engineer-in-charge.
Supply and fixing in replacement power contactor 415 volt, 50 cycles, 3 phase, type AX-65-30-10 complete all as directed by Engineer-in-charge.
Supply and fixing in replacement power contactor 415 volt, 50 cycles, 3 phase, type AX-80-30-11 complete all as directed by Engineer-in-charge.
Supply and fixing in replacement power contactor 415 volt, 50 cycles, 3 phase, type AX-95-30-11 complete all as directed by Engineer-in-charge.
Supply and fixing in replacement power contactor 415 volt, 50 cycles, 3 phase, type AX-115-30-11 complete all as directed by Engineer-in-charge.
Supply and fixing in replacement add on auxiliary contact block for MDX/ MNX/AX type contactor range 9-110 / 9- 80 complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacement bimetal over load relay single phase protection directly mounted 28 to 42 Amps, range ML2/ML3 complete all as directed by Engineer-in-charge. Make L & T or similar in Havells/AE
Supply and fixing in replacement bimetal over load relay single phase protection directly mounted 66 to 110 Amps, range MN5 complete all as directed by Engineer-in-charge.
Supply and fixing in replacement bimetal over load relay single phase protection directly mounted 45 to 75 Amps, range MN5 complete all as directed by Engineer-in-charge.
Supply and fixing in replacement electronic timer (time delay relay) of range 12-120 sec, input voltage 220 to 240 volts AC complete all as directed by Engineer-in-charge. Make for serial item No. 49 to 60 and 62 to 64 : L&T / ABB/BCH/Simens
Supply and fixing in replacement single phase preventor, type VSP-2/3 suitable for 3 phase star delta starter of any capacity complete all as directed by Engineer-in-charge.
Supply and fixing in replacement three phase Amps meter of size 96x96x80mm, flush mounting on panel 0 to 200 Amp, digital type, complete all as directed by Engineer-in-charge. Make : Conzerv / Enercon /Siemens/ L & T/ AE/IMP/MECO
Supply and fixing in replacement MCCB, 250 Amp, 4 pole ,415 Volts, FP, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as directed by Engineer-in-charge.
Supply and fixing in replacement MCCB, 250 Amp, 3 pole ,415 Volts, FP, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as directed by Engineer-in-charge.
Supply and fixing in replacement MCCB, 200 Amp, 3 pole ,415 Volts, TP, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as directed by Engineer-in-charge.
Supply and fixing in replacement MCCB, 160 Amp, 3 pole ,415 Volts, TP, 50 cycle, breaking capacity 36 KA, thermal magnetic releasecomplete all as directed by Engineer-in-charge.
Supply and fixing in replacement MCCB, 125 Amp, 3 pole ,415 Volts, TP, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as directed by Engineer-in-charge.
Supply and fixing in replacement MCCB, 63 Amp, 3 pole ,415 Volts, TP, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as directed by Engineer-in-charge. Make for serial item No. 68 to 73 : L&T /Simens/Legrand/Schenider
Supply and fixing in replacement on load change over switch 4 pole front operated with out sheet metal enclouser enclosed execution 415 volt 50 Hz ,800 Amp capacity Make - L&T/Havells/Simens/Legrand/Schenider
Suply and fixing in replacement fully automatic star delta starter 415 volts 3 phase with single phase protection feature with relay range 45 to 75 Amp and suitable size of contractors in sheet steel enclosures suitable for 60 HP electric motor complete disconnecting/removing the defective starter from existing position and refixing the new in same poisition and making electric connections complete all as directed by Engineer-in-charge.
Suply and fixing in replacement fully automatic star delta starter 415 volts 3 phase with single phase protection feature with relay range 28 to 42 Amps and suitable size of contractors in sheet steel enclosures suitable for 25 HP electric motor complete disconnecting/removing the defective starter from existing position and refixing the new in same poisition and making electric connections complete all as directed by Engineer-in-charge.
Supply and fixing in replacement direct on line (DOL) starter in sheet metal enclosure type, 415 Volt, 3 Phase, suitable for and upto 10 HP electric motor complete all as directed by Engineer-in-charge.
Supply and fixing in replacement direct on line (DOL) starter in sheet metal enclosure type, 415 Volt, MK-1 suitable for and upto 5 HP electric motor complete all as directed by Engineer-in-charge. Make for serial item No. 75 to 78 : L&T/ Siemiens/Havells/Schenider
Supply and laying in replacement Flat three core PVC insulated and PVC sheathed industrial cable for submersible pumps, size 6 sqmm, 3 core, 1100 volts grade, confirming to IS 694 in existing lowering pipe and clamps nut bolts etc and making connections with motor and starter complete all as directed by Engineer-in-charge
Supply and laying in replacement single core HRFR PVC insulated industrial grade copper conductor (unsheathed) flexible cable size 25 sqmm, 1100 volts, confirming to IS:694 complete all as directed by Engineer-in-charge
Supply and laying in replacement single core HRFR PVC insulated industrial grade copper conductor (unsheathed) flexible cable size 10 sqmm, 1100 volts, confirming to IS:694 complete all as directed by Engineer-in-charge
Supply and laying in replacement Four core HRFR PVC insulated industrial grade copper conductor (unsheathed) flexible cable size 4 sqmm, 1100 volts, confirming to IS:694 complete all as directed by Engineer-in-charge. Make for serial item No. 79 to 82 : Havells/Polycab wires/Finolex
Supply and fixing in repair pressure switch type PM/5 suitable for jet pumpset of cap 0.5 HP/ 0.75 HP for automatic operation of pump complete all as directed by Engineer-in-charge.
Supply and fixing in replacement flexible spare tyre coupling TC-014/ TC -015 including alignment of pump and motor complete all as directed by Engineer-in-charge
Supply and fixing in replacement flexible spare tyre coupling TC -016/ TC-017 including alignment of pump and motor complete all as directed by Engineer-in-charge
Supply and fixing in replacement flexible spare tyre coupling TC -018/ TC-019 including alignment of pump and motor complete all as directed by Engineer-in-charge
Material & labour for painting of existing pumpset (with electric motor) and foundation of capacity 60 HP to 120 HP with spray paint carefully after dismentling the motor from foundation and assemble after painting as per approved tint complete all as directed by Engineer-in-charge
Material & labour for painting of existing pumpset (with electric motor) and foundation of capacity 15 HP to 50 HP with spray paint carefully after dismentling the motor from foundation and assemble after painting as per approved tint complete all as directed by Engineer-in-charge
Labour for taking out CI foot valve/Non return valve of any size from jack well approximate 3 mtr deep and refixing the same in original positions after fixing leather buffalow complete all as directed by Engineer-in-charge Note - Rate of leather buffalow /nut bolts and rubber sheet will be included in this item .
Supply only oil imeressed graphite gland packing off sizes of superior quality complete all as directed by Engineer-in-charge
M/s Kataria Construction Company
Aman Enterprises
MODERN ENTERPRISES
Bidder Name
Vardhman Airport Solutions Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .