EE RWS Z P JALGAON
EE RWS Z P JALGAON
JJM WATER SUPPLY SCHEME AT AADGAON TAL YAWAL DIST JALGAON.
2025_JALGA_1252246_4
ZP/Jalgaon/JJM/12/6,7Call/2025
Open Tender
Civil Works
Percentage
125 days
EE RWS Z P JALGAON
Please refer Tender documents.
9 documents required · 9 mandatory
₹5,400
₹42,564
26 Nov 2025
26 Nov 2025
10 Dec 2025
26 Nov 2025
8 Dec 2025
26 Nov 2025
RISING MAIN Item No. 1:- Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 /14151 / 12786 /13488 (Latest version) with nesessary jointing material like mechanical connector i. e.thread / insert joint / quick release coupler joint/ compression fitting joint or flanged joint excludingcoupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. 110 mm HDPE 6 kg pipe
Providing and supplying double flange sluice valves confirming for IS 2906/14846 including warn gear arrangement as per test pressure stainless steel spindle caps including all taxes transportation etc complete. Sluice/Score valves PN - 1 --80 mm dia.
Score valves PN - 1 --100 mm dia.
Providing at site of works PVC .specials suitable for above pipes including cost of all taxes, freight charges, octroi, loading, unloading and conveyance to Deptt.store etc. complete. 1 % of Cost of pipes
Providing & supplying GI PIPES following class and dia.excluding GSTlevied by GOI &GOM in all respect inspectionetc complete.
Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum,Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road,Excavation for foundation / pipe trenches by blasting in soft rock and old cement and lime masonry foundition asphalt road, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.
Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction complete. For murrum bedding
Lowering, Laying and Jointing P.V.C. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loadingclamp etc. and all labours as directed by engineer incharge as per IS-7634 Part II 110 mm HDPE 6 kg pipe
Lowering, Laying and Jointing P.V.C. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loadingclamp etc. and all labours as directed by engineer incharge as per IS-7634 Part II 125 mm 16.70 kg/m
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and excluding hydraulic testing etc. complete. (Rate for all class of valves.) Sluice / Scour & NRV valves PN - 1 -100 mm dia
Reflux valves PN - 1 --80 mm dia
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
PUMPING MACHINARY Item No. 1:- Providing erecting and giving test of submersible pump set confirming to IS. 8034 and motor confirming to I.S. 9283 with water proof binding pump shall be suitable for various delivery head and discharge with stainless steel shaft motor suitable for working on 415 10% 3 ph 50 Hz A.C. supply with cable gurad thrust carbon fiber bearing to with stand entire hydrulic thrust .the pump set shall be suitable for direct coupling with suitable saction stainer pump should have suitable discharge outlet as per manufacture design antithrust stream non retun valve shall be provided with the pump 3 m submersible copper conductor cable in single / double run 2 pair of erection clamp 65 mm width 10 mm thick shall be provided with each pump Submersible pump 5 HP with errection
Submersible pump 5 HP with SUPLY
Item No. 2:- Providing erecting commissinory L.T. panel board with all required accessories for the pump in above item No. 1.. etc.complete
Item No. 3: - Supplying and erecting Flat flexible submersible cable with copper conductor PVC insulated and PVC sheathred 1 x 3 x 4 sqm
B) Providing and erecting P.V.C. armoud cable 1100V grade with ISI mark 3.5 core Solid / standard aluminium conductor with 6 mm thick 25 mm width m.s.. Spacer with G.I. Earth wire 6 Sq. mm complete erected on wall / on Pole with 25 X 3mm M.S. Clamp in provided trench in an approved manner 4 Core 10 Sq. mm
Providing ISI Mark G.I Pipe of following class and dia.excluding GST levied by GOI and GOM in all respect incl. inspection charges transportation to stores, etc complete as per .. 50 mm Dia G.I Pipe ( Heavy)
Item No. 5:- Providing and erecting presure gauge of required capacity complete with syptio tube isolating cock suitable for 12 mm dia G.I. Pipe pressure gauge shall be installed as directed with tapping on rising main 100 mm. Dia
Item No. 6:- Supplying errecting G.I pipe A Grade….. 25 mm dia …cover the cable all over 15 mm dia G.I pipe
Item No. 7 :- Providing and supplying G.I. special at site including all taxes (central & Local )RailwayFright Insurances on loading from Railway wagon Loading Truck Transport to store/site unloading etc.. Comp. As directed by Engineer in Charge
Item No. 8:- Providing and supplying ISI mark C.I. D/F reflux valve (non return valves) of following dia including all taxes (central and local) railway freight inspection charges loading unloading from railway wagon 65 mm dia P.N. 1 with fixing
Item No. 9:- Providing and supplying ISI mark C.I.D.F sluice valve of following dia including all taxes (central and local railway freight inspection entries unloading from railway wagon loading into truck transportation upto departmental store/site unloading stacking etc. complete. 65 mm dia P.N. 1 with fixing on delivery side ( 4966+1251)
Providing and making flaged Joint to flange, C.I. Pipes / M.I. Pipes and specials of all classing including cost of jointing material rubber packing nut bolts labour charges hydrulic testing etc. complete 80 mm dia joint
Item No. 10 :- Supplying and erecting Galvanized cast iron earth plate 60 X 60 X 0.6 cm buried specially preposed earth pt[top edge of plate 1.5 m below ground refilling with 30 kg chorcoal and salt in alleviate layers neccessory length of double G.I. earth strip connected to the plate G.I. nuts bolt 12 mm dia iwth Bituminous compound and connected to nearest switch gear with end socket as per directed supplying and erecting 19m dia ventical G.I. pipe 1.5 m long with funner and mesh at top included in the scope of work.
Item No. 11:- Providing and supplying internal elactrification to switch room etc. comp. Rate analysis attached
Item No. 12:-Providing tools with tool box etc complete
Providing and fixing wall mounting type name board duly painted all details of pumping machinery make, model frame no. DR no. Date of installation commissioning manufacture year agoncy name aggrement no details of G.I. Shal 18 gauge of required size duly painted with red oxide and enamus paint for dispaying the above details board shall be provided with suitable T.W. bottom back side name board
RCC ESR CAP 64,000 LITR STG HT 12.00M Item.No.1 :- Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters centre to centre for E.S.R.having capacity 500 m3 & not more than 6 m c/c for E.S.R.having capacity above 500 m3 including excavation in all types of strata, foundation concret, cement plaster with water proofing compound to the inside face of the containerincluding refilling disposing of the surplus stuff within a lead of 50 meters, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design. providing and fixing accessories such as Stainless steel ladder inside and M.S. ladder with G.I. railing outside, C. I. manhole frame and covers water level indicatiors, lightening conductor, G. I. pipe railing around walk way and top slab, providing spiral staire case from ground level to roof level, M.S.Grill gate of 2 Mtrs height with locking arrangement, B.B. masonry chambers for all valves, ventilating shafts, providing and applying three coats of acrylic emulsion with silicon additives paint to the structure including roof slab and epoxy paint to internal surface & anti-termite treatment for underground parts of the structures and giving satisfactory water tightness test as per I.S. code, The job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-charge. Notes:1. The design of the structure be in accordance with relevent (I.S.3370 - 1965 or revised) 2. The design shall satisfy the stipulation as per IS 1893-1984 and I.S. 13920/1993 for seismic focrce and I.S.- 11682/1985 for R.C.C. staging of overhead tanks. 3. For design having more than 6 columns, Providing of internal bracing is obligatory,. External bracking is also obligatory. 4.. The entire structure shall be in M 300 mix only. 5. Plain round mild steel bars grade - I confirming to I.S,432 Part-I or high yield strengh deformed bars confirming to I.S. 1786 or I.S. 1139 shall be used, grade-II mild steel bars will not be allowed. 6. Irrespective of the type of foundation proposed in the design, one set of bracing be provided at the gound level. 7. These rates include providing, M.S. ladder for E.S.R's upto 2 lakhs liters capacity and providing sprial staircase for E.S.R. above 2 lakhs liters capacity. 8. Stagging shall have to be designed with stresses of M-250 for ESR. However all RCC construction should be done in M-300 9. These rates are including the cost of uplift pressure if any and entire dewatering during execution. In case of water logging area where water is struck at shallow depth extra provision of dewatering shall be made as per site condition. 10. All condition given in the Member Secretary"s Circular No.MJP/TS-I/350/1668 dt. 2.8.97 and MJP/S-I/350/2127 dt.13.7.99 shall be strictly followed and additional cost, if any due to these conditions is included in the rates mentioned below. 11.. 75% part rate shall be payable for reinforced cocnrete and plastering items of containers of E.S.R. till satisfactory hydraulic testing for water tightness is given ; and till that work shall be treated as incomplete. 12. The rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet washout overflow and by-pass arrangement. The scope of work, however inclueds cost of erecting, laying and jointing of pipes and valvews including cost of jointing materials upto 5M beyond outer face of outermost column. 13. For ESR upto 500cum capacity C.I.D. double flanged pipes upto 300mm dia shall be provided and C.I.Specials shall be used.For ESR above 500 cum capacity C.I./M.S. pipes assembly with minimum 8mm thick ness up to 500mm dia. And minimum 10mm thickness above 500mm dia can be used with proper anti-corrosive epoxy teratment from inside and outside. 14. Below mentioned rates are for foundation, with individuals footing with bearing capacity of 30 tonnes per square metre. For raft foundations, these rates shall be increased by 7.5% wheresafebearing capacity ( SBC) is 5 M.T. per Sq.m and by 5% where SBC is more than 5 MT/Sqm. and upto 10MT/Sq.m. This percentage of 5% or 7,5% is applicable for estimation of amount of L.S. items ESR for Extra item due to change from individual footing foundation to raft actual increase in concrete and steel quantities be paid as per relevent DSR Item. 15.The rates shall be increase by 30% for brearing piles upto depth of 10m and for further increased in depth by 5M each it shall be increased by another 10% These rates are applicable where raft is not reasible for pile foundation sulfate resistant cement shall only be used. Single pile for the column is not permitted Group of piles shall be designed with pile cap for each column of ESR. 16. These rates are applicable for staging height of 12 M These rates shall be increased or decreased for per metre variation in the staging height as below 12 to 16 M staging 2% per metre 16 to 20m staging 3% per meter 20 M and abovd - 4% per metre I.e. for 17m stagging height percentage calculation will be like below 12 to16m = 4 x 2 = 8% 16 to 17 m x 1 x 3 = 3% Total = 11 % For 21 m stagging height Percentage calculation will be like below 12 to 16m = 4 x 2 = 8% 16 to 20m = 4 x 3 = 12% 20 to 21m = 1 x 4 = 4% Total = 24% 17. Following rates are for seismic zone-III for Zone-IV these rates shall be increased by 5% and for Zone-II, these rates shall be decreased by 5% concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones( Seismic maps attached in this C.S.R.) Note:- 1) Conditin from Sr.No.1 to 11 shall form a part and parcel of the tender papers and shall be included in the DTP for works of R.C.C.E.S.R. Note:-2) Condition from Sr
.No.12 to 17 are for estimation purpose only and shall not be appear in the tender. Cost of 64,000 litres capacity 12 m stage height ESR Add for raft foundation 7.5 % Net Total Cost of 64,000 litres capacity 12 m stg. height ESR RCC ESR 64,000 lit.Cap.
Providing and supplying ISI standard CI double flanged pipes excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, 100 mm dia.D I D/F pipe
100 mm dia.D I D/F pipe
Providing and supplying double flange sluice valves confirming for IS 2906/14846 including warn gear arrangement as per test pressure stainless steel spindle caps including all taxes transportation etc complete. 80 mm dia. D/F Sl. Valve PN 1.0
Providing and supplying ISI standard C. I. specials & fittingwith sealing rubber gasket of S.B.R,complete with cast iron follower gland and M. S. nut bolts coated or otherwise protected from rusting and suitable for D.I.pipes including cost of labour, materials, and transportation to stores, loading and unloading excluding GST levied by GOI & GOM in all respect etc. complete as per IS-9523.
Add.Distribution Item No. 1:- Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit type to be jointed with cement solvent). 110 mm pvc 4 kg/cm2 pipe
90 mm pvc 4 kg/cm2 pipe
75 mm pvc 4 kg/cm2 pipe
140 mm pvc 4 kg/cm2 pipe
Providing ISI mark G.I. pipe of following class and dia.excluding GST levied by GOI and GOM in all respect including inspection charges, transportation to stores, etc. complete .as per IS -1239/2004
Providing at site of works PVC.specials suitable for above pipes including cost of all taxes, freight charges, octroi, loading, unloading and conveyance to Deptt.store etc. complete. 10% of Cost of pipes
Providing and supplying double flange sluice valves confirming for IS 2906/14846 including warn gear arrangement as per test pressure stainless steel spindle caps including all taxes transportation etc complete. Sluice valves PN - 1 --80 mm dia.
Sluice valves PN - 1 --100 mm dia
Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum,Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road,Excavation for foundation / pipe trenches by blasting in soft rock and old cement and lime masonry foundition asphalt road, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.
Sluice valves PN - 1 --125 mm dia
Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. ( Bd-A-4/259)
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction complete For murrum bedding.
Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint). 140 mm pvc 4 kg/cm2 pipe
Add.Distribution Item No. 1:- Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit type to be jointed with cement solvent). 110 mm pvc 4 kg/cm2 pipe
90 mm pvc 4 kg/cm2 pipe
110mm pvc 4 kg/cm2 pipe
Lowering ,laying and jointing G.I.pipes and specials of following class and Dia.including conveyance from store to site of work ,all labour ,giving satsfactory hydraulic testing etc completeeither underground or in vertical position as directed by engineer in charge
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and excluding hydraulic testing etc. complete. (Rate for all class of valves.) Sluice valves PN - 1 --80mm dia.
Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in C.M. 1:5 Proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. Size 90 x 45 x 120 cm.
Providing and laying in situ, following grades of C.C. of trap/granite/quartzite/gneiss metal for foundtion and bedding incluing dewatering, form work, compaction and curing, finishing, etc. complete. PCC (1:2:4) ie M - 150
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
Providing and fixing C.I. road box including loading, unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc. complete. 100 mm x 225 mm (20 kg)
TRAIL RUN Item No. 1:- Commisioning running and maintaining the scheme to quantites, rated capacity, including manning necessary personnel such as operator, valveman, etc. as per requirements of the scheme and who should also administer chemical dose for a period of 1 month for individual scheme and 3 months for regional scheme, together with training of personnel spared by MJP/ Local Body and handing over the scheme to Local Body after completion of the above period as directed by Engineer-in-charge. Trial Run For 1 month
Provision for Energy charges for one month -- etc comp.
Provision for Chemical charges for one month -- etc comp. For 3 Months requirement (0.287 x 90x5 kg )=0.13 MT
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.40 MB
DTP.pdf
Tender Documents • 2.83 MB
BOQ_2159014.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .