| 1 | 1₹19.4 LAccepted-AOC 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | 1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | 2₹22 L+₹2.6 L (13.4%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹22.1 L+₹2.7 L (14.1%)Rejected-Finance | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹23.7 L+₹4.3 L (22.4%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹24.3 L+₹4.9 L (25.2%)Rejected-Finance | 5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
23 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
UPKEEPING AND MAINT OF SEWAGE SYSTEM AND CLEANING OF SEWAGE LINE ETC OF ZONE B INCL MES QTRS AT PATIALA
2022_MES_548169_1
GE(N)/PAT-53/2022-23
Open Tender
Civil Works
Lump-sum
240 days
PATIALA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹60,000
Yes
1 Nov 2022
27 Aug 2022
26 Sept 2022
27 Aug 2022
23 Sept 2022
10 Sept 2022
Amount
Schedule 'A'Part -I (B/R SCHEDULE)
Total amount of Sch 'A' Part I (B/R SCHEDULE)
Schedule 'A' Part-II (Misc Schedule) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Cleaning of under ground sewage network including manholes obstruction free by removing sludge and any type of blockage in any kind of manhole or lines including removing blockage inside the building from EWC/WC/floor trap/gully trap etc in old cantt area by deploying adequate manpower and suitable T&P so as to avoid damage to the line/structure complete all as specified and as directed.
Note:- (i) Sewage network under old cantt area consists appx 7.50 Km long (Dia of pipe up to 200mm-6.00 Km & Dia of pipe exc 200mm but n. exc 600mm-1.50 Km) (ii) Contractor or his rep will report daily at complaint cell of old cantt at 9.00 AM for collection of complaints from the concerned JE's Incharge, on failure a penalty of Rs. 500/- per day in addition to delay in attending the complaints will be charged. A seperate muster roll register will be maintained in AGE office. (iii) Immediately after lodging daily complaints by the users or directed by the EIC consequent to his routine check, the concerned JE shall intimate/hand over the complaint to the contractor or his rep for attending complaints to the satisfaction of user / Engineer-in-charge within 24 Hrs. In case of failure to attend the complaint within specified period, a penalty of Rs.100/- per day per complaint shall be imposed on the contractor for the period the work remains incomplete. After 03 days from the date of handing over of complaint, the unattended complaints shall be got completed from any other agency at the risk and cost of the contractor without any notice to the contractor. In case of disputes as to delay happened in attending the complaint or inadequate period, decision of Accepting Officer shall be final, conclusive and binding.
Cleaning the sewage sump wells, septic tanks of any dia depth and in any location etc by taking out complete sludge water and solids mechanically by HCV mounted suction discharge machine having flow back facility with sludge tank of adequate capacity removing & disposing the entire retrieved material to a distance not exceeding 1000 meter outside the periphery of defence land and covering the entire sludge with local earth complete all as directed by the engineer-in-charge. Note : Depth of sludge in the pit shall be measured from the bottom of pit to the existing water/effluent lever prior to ordering the cleaning in the presence of EIC.
S&F single Y-shaped CI junction pieces, ordinary or inverted (spigot or socket type) for 100mm bore pipes complete all as specified and directed.
M&L machine pressed rubber moulded ISI marked precast cement concrete interlocking paver block any shape and size and of colour 50 % red coloured tiles and 50% grey coloured tiles confirming to IS-15658-2006 of 60mm thickness M-35 grade and including filling of interstices with fine sand over including 25mm thick layer of sand cusion over 75mm thck PCC 1:4:8 type D-2 (40mm graded stoen agg), complete all as specified and as directed.
M&L RUBBER MOULDED COLOURED CHEQUERED tiles 30cm X 30cm X 22mm thick with grey cement and pigment, set jointed and pointed in neat cement slurry as in floor complete all as specified and directed.
S&F reinforced precast factory made concrete manhole/drain covers of size exc 0.12sqm but n exc 1.00 sqm and thickness not less than 50 mm and shape of square/rectangular/circular fixed in position complete all as specified and directed. For measurement purpose it will be measured in cubic metre. Make : S K Engineers, Patiala/ Manju Concrete Fabricators, Mohali/ Radhika Enterprises, Ambala
SWAMI ENGINEERS
M/s Harmans
AR CONSTRUCTIONS
KK BUILDERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .