| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹27.2 L+₹4.4 L (19.5%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹28.7 L+₹5.9 L (26.2%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹30.0 L+₹7.3 L (32.1%)Rejected-Finance H NO 114 A 10 GHAZI NAGAR RADDI CHOWKI GOHALPUR JABALPUR MP | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
18 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER SAUGOR
Military Engineer services Garrison Engineer Saugor MP- 470001
COMPREHENSIVE MISC B/R REPAIR WORKS IN MD ACCN OF VARIOUS UNITS UNDER AREA OF AGE B/R-II AT GE SAUGOR
2024_MES_661323_1
GE/SGR/TOK-23 OF 2024-25
Open Tender
Civil Works
Item Rate
270 days
Saugor
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER SAGAR
₹74,000
Yes
31 Aug 2024
21 Jun 2024
20 Jul 2024
21 Jun 2024
18 Jul 2024
6 Jul 2024
22 Jun 2024 - 1 Jul 2024
Amount
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
Demolition of RCC in precast cover slab any thickness (reinforced) complete all as specified and directed by Engineer-in-charge.
Dismantling of floor, hearth or wall tiles / terrazo including cement mortar bedding (but not backing), removal servicable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
Demolition of stone set paving of any description or thickness laid, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete unreinforced in ground floor and pavings any thickness and any position complete all as specified and directed by Engineer-in-charge.
Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) n exc 1.5 sqm each etc complete all as specified and directed by Engineer-in-charge.
Taking down chowkats or frames with shutters (w/o taking of shutters from the frame) exc 1.5 but n exc n.exc 4 Sqm each complete all as specified and directed by Engineer-in-charge.
Taking down shutters of any description exc 1sqm but n exc 2sqm each complete all as specified and directed by Engineer-in-charge.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion & making good disturbed ground embedded in Concrete, brick work, masonry complete all as specified and directed by Engineer-in-charge.
M&L for PCC in foundations, filling and mass-concrete type B2 (1:2:4) using 40 mm graded stone aggregate complete all as specified and directed by Engineer-in-charge.
M & L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 including demolition of brick masonry, built in cement mortar incl all quoins, arches, pillars, etc and removing of rubbish off the premises complete all as specified and directed by Engineer-in-charge.
Cutting chases, pinning in, in brick/stone wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, in cement mortor 1:3 cutting not exceeding 10cm girth complete all as specified and directed by Engineer-in-charge.
M & L for Mild steel TMT bars 10mm dia, and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and directed by Engineer-in-charge.
M & L for Mild steel TMT bars 6mm to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and directed by Engineer-in-charge.
M & L for Precast reinforced cement concrete type B1 (1:2:4) using 20 mm graded aggregate set in CM(1:4) in landings,kitchen platform, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed by Engineer-in-charge.
M & L for non skid joint free ceramic coloured tiles 7 to 8mm thick area of each tile exc 0.18 Sqm but not exc 0.38 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screeed bed layer in CM (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for non skid joint free ceramic coloured tiles 7 to 8mm thick area of each tile exc 0.18 Sqm but not exc 0.38 sqm in dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 10mm thick plaster in CM (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for non skid ceramic coloured tiles 7 to 8mm thick area of each tile exc 0.06 Sqm but not exc 0.11 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screeed bed layer in CM (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for non skid joint free ceramic coloured tiles 7 to 8mm thick area of each tile exc 0.11 Sqm but not exc 0.18 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screeed bed layer in CM (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for non skid joint free ceramic coloured tiles 7 to 8mm thick area of each tile exc 0.11 Sqm but not exc 0.18 sqm in dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 10mm thick plaster in CM (1:4) complete all as specified and directed by Engineer-in-charge.
Material & labour for glazed ceramic tiles of size 600x 300 x 7 mm thick,(joint free (rectified)) coloured, on vertical surfaces such as skirting/dado etc, set and jointed in neat cement slurry and pointed in white/coloured cement to match over and including 15 mm thick rendering in CM 1:4 complete all as specified and directed by Engineer-in-charge.
M&L for 600 x 600x 8-10 mm thick coloured vitrified tiles in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screeed bed layer in CM (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for 600 x 600x 8-10 mm thick coloured vitrified tiles in dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 10mm thick plaster in CM (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for mirror polished Machine cut kota stone slab flooring 18-20 mm thick over 15mm thick screed in CM(1:4) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed by Engineer-in-charge.
M & L for Kota stone slab 12-15 mm thick in skirting, over 15mm thick plaster in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed by Engineer-in-charge.
M&L for 16-18 mm thick Granite of any shade ( table rubbed and polished ) in steps, jambs, pillars, windowcills, cooking plateforms and like in cement mortor 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match shade of the slabs complete all as specified and directed by Engineer-in-charge.
M & L for rounding/ chamferring to edges of stone slabss one edge , such as in steps , cooking plateform and other similar situations complete all as specified and directed by Engineer-in-charge.
M&L for machine pressed precast cement concrete coloured chemically treated interlocking paver block any shape and size conforming to IS-15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment laid over and including 30 to 50 mm thick uniformly levelled surface of stone dust cushioning and including PCC 1:2:4 type B-0 as in coping all around of size 150 x100 mm thick complete all as specified and directed by Engineer-in-charge.
M & L for cement concrete 1 : 3 :6 type C-2 using 40mm graded stone aggregate as in plinth protection 75mm thick finishing cement concrete surfaces even & smooth without using extra cement including filling of construction joint with bitumenous sealing compound complete all as specified and directed by Engineer-in-charge.
M&L for plain cement concrete type D-2, 1:4:8 (using 40 mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M & L for rendering 15mm thick cement plaster on wall in cement mortar 1:6 on brick wall / Concrete surfaces of finishing the surfaces even and smooth complete all as specified and directed by Engineer-in-charge.
M & L for Rendering 15mm thick on stone masonry surfaces or surface other than fair face of brickwork in CM (1:4) and 5 mm thick in second coat including water proofing compound @ 2% by wt of cement complete all as specified and directed by Engineer-in-charge.
M & L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete all as specified and directed by Engineer-in-charge.
M & L for Providing cement concrete 1:2:4 type BO ( using 12.5 mm graded stone aggt ) as in coping ,apex stone , bed plate , kerbs including weathering , slightly rounded or chamferred angles and throating and incl. necessary form work etc complete all as specified and directed by Engineer-in-charge.
M & L for applying two or more coat of Ist quality acrylic distemper (ready mixed) having VOC contents less than 50 gms/litre of approved manufacturerof required shade and colour complete as per manufacturer's specification including providing and applying plaster of paris putty 1 mm thickness over plastered surface to prepare the surface even and smooth, including priming of coat of interior primer incl. preparation of new wall surfaces of walls etc complete all as specified and directed by Engineer-in-charge.
M & L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 sqm including priming coat of exterior primer applied @ 0.90 litre / 10 sqm over new surfaces, including preparation of surfaces of new walls etc complete all as specified and directed by Engineer-in-charge.
M & L for applying two or more coat of Ist quality acrylic distemper (ready mixed) having VOC contents less than 50 gms/litre of approved manufacturerof required shade and colour complete as per manufacturer's specification including providing and applying plaster of paris putty 1 mm thickness over plastered surface to prepare the surface even and smooth, incl. preparation and complete removal of existing treatment of old surfaces of walls etc complete all as specified and directed by Engineer-in-charge.
M & L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 sqm including priming coat of exterior primer applied @ 0.90 litre / 10 sqm over new surfaces., including preparation and complete removal of existing treatment of surfaces of old surfaces etc complete all as specified and directed by Engineer-in-charge.
M&L for applying three coats of white wash on new or old Ceiling surface including preparation of surface complete all as specified and directed by Engineer-in-charge.
M&L for applying three coats of white wash on new or old on wall surface including preparation of surface complete all as specified and directed by Engineer-in-charge.
S&F GI (cold rolled) snap grid size of 600mmx 600mm frame work of 24x38x0.60mm, Tee section (bottom pre coated) and 24x24x0.5mm thick angle rung along the wall including GI suspendes wire as per manufacturer instruction as in ceiling with and including S&F coloured non asbestos designer ceiling cement boards 4mm thick including dismantling old false ceiling board including frames (if any) & cover fillets in ceilings (measured flat & not girthed) complete all as specified and directed by Engineer-in-charge
M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs fixed with L-type or J-type or cranked hook bolts including dismantling existing Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed by Engineer-in-charge.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings and refixing the sheet at same or other roof fixed with new L-type or J-type or cranked hook bolts complete all as specified and directed by Engineer-in-charge.
M&L for 6mm thick asbestos cement serrated ridge or hip ridge for corugated or semi corugated sheets, fixed with L-type or J-type or cranked hook bolts including dismantling existing damaged AC sheet ridge/hip for corrugated or semi corrugated sheets from roof complete all as specified and directed by Engineer-in-charge.
M&L for pre- coated coloured galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa (AZ150) as in roof covering/ clading to wall, including crimping sheet at end fixed with self tapping screws, including dismantling of existing Asbestos cement (corrugated, semi corrugated, etc) sheets roofing complete all as specified and directed by Engineer-in-charge
M&L for second class hardwood in scantlings , timber clean sawn framed and fixed including dismantling existing unframed timber scantlings 40 sq. cm & over in section, in any position complete all as specified and directed by Engineer-in-charge
M&L for 2nd class H/W, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engineer-in-charge
S&F of 105 mm X 60 mm size pressed steel frames for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one shop coat of red oxide primer including cutting holes and making good in P:C:C 1.2.4 type B-1 using 20 mm graded stone aggregate and M&L PCC 1:3:6 type C-0 using 12.5 mm graded store aggregate for filling in pressed steel frame complete all as specified and directed by Engineer-in-charge
S&F of 125 mm X 60 mm size pressed steel frames for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one shop coat of red oxide primer including cutting holes and making good in P:C:C 1.2.4 type B-1 using 20 mm graded stone aggregate and M&L PCC 1:3:6 type C-0 using 12.5 mm graded store aggregate for filling in pressed steel frame complete all as specified and directed by Engineer-in-charge
M&L for Mild steel door shutter with MS angle iron shutters frame 35 mm X 35 mm X 5 mm in two panel covered with 1.25 mm thick MS plain black sheet welded to shutter with 2 Nos sliding door bolt of 16 mm dia 300 mm long with locking arrangement, 2 Nos of tower bolt of 200 mm long including MS angle iron frame 40mm x40mmx 5mm as in chowkhat with 6 Nos hold fast of flat iron 30mm X5 mm ,200 mm long with bottom flat iron of size 30mmx5mm and 100 mm size 4 Nos butt hinges including necessary cutting, welding, binding as required with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces complete all as specified and directed by Engineer-in-charge. [Single shutters of approx width0.8 to 1.2 m and ht 1.9 to 2.10 M.]
S&F of steel window with side hung shutters with glazing bars devetailed or welded, fixed on and including pressed steel frame of size 80mm x 40mm x 1.25mm thick CRCA profile section with box type hinges, steel handle, steel peg stay etc complete all as specified and directed by Engineer-in-charge
S&F of steel window with side hung shutters without glazing bars devetailed or welded, fixed on and including pressed steel frame of size 80mm x 40mm x 1.25mm thick CRCA profile section with box type hinges, steel handle, steel peg stay etc complete all as specified and directed by Engineer-in-charge
S&F of fixed type ventilators aluminium powder coated of frame size 50.80X 25.40mm,1.5 mm thick half portion will be fixed with 4mm thick frosted glass and half portion will be fixed with louvers with 4mm thick frosted glass with rubber gasket and aluminium beading ,aluminium grill with fixing arrangement (wt. of grill not less then 2.50 kg/sqm),aluminium wire mess 0.36 mm dia and aperture size of wiremesh 1.18mm to be fixed over louvers portion only including necessary cutting holes on wall and fixing arrangements complete all as specified and directed by Engineer-in-charge. (Al. section thickness 1.50 mm }
S&F of aluminium windows sliding type three track powder coated consisting of frame bottom with gutter of size min 92.34 X 39 mm,sideand top of size min 92.34X29.70, shutters vertical 39X20 mm,shutter top &bottom of size min 20X39 mm ,shutter interlock min size 39X20 mm with rollers and conceled locking arrangements with 4 mm thick tinted glass with rubber gasket,brush and aluminium beading , aluminium wire mess 0.36 mm dia and aperture size of wiremesh 1.18mm etc including necessary cutting holes on wall and floor and confirming to IS complete all as specified and directed by Engineer-in-charge. (Al. section thickness 1.50 mm }
S&F of 35mm thick 2nd class HW factory made plain framed, penelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per : IS 1003 (part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-charge
S&F of 35 mm thick flush shutters, solid core construction, with block board core and plywood facepanels, commercial type on both sides complete all as specified and directed by Engineer-in-charge
M&L for 2nd class HW factory made glazed and skeleton shutters 35 mm thick open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chemfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, cla-use 8.24 (a); for doors supplied and fitted to chowkats complete all as specified and directed by Engineer-in-charge
S&F of Solid PVC door frame of size 50mmX47mm made out of 5mm single side prelam PVC sheet used instead of plain colour PVC sheet (edges will be painted to match with prelam sheet) reinforced with MS square tube, suppling & fixing in opening as per specification complete all as specified and directed by Engineer-in-charge
S&F of factory made solid PVC moulded door shutterwith wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6mm raised panel design with 5 mm thick moulded PVC sheet on the front face & 5mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specified complete all as specified and directed by Engineer-in-charge
S&F of 18mm/19 mm prelaminated particle board,interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work or angle iron chowkhat, including taking out old board complete all as specified and directed by Engineer-in-charge
S&F of 2nd class HW beads, straight (any size) for glazed or gauzed joinery, renewed, including mitres etc and removing old beads complete all as specified and directed by Engineer-in-charge
S&F of galvanised mild steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engineer-in-charge
S&F of galvanised mild steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, including taking out old wire cloth complete all as specified and directed by Engineer-in-charge
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-charge
M&L for preparation of new wooden surfaces of any description not exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-charge
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide complete all as specified and directed by Engineer-in-charge
S&F of Aluminium handles 150mm size, cast type, anodised complete all as specified and directed by Engineer-in-charge
S&F of Aluminium, anodised, barrel tower bolts 150mm long of extruded section complete all as specified and directed by Engineer-in-charge
S&F of 100mm Butt hinges, extruded aluminium aloy with galvanised mild steel hinge pin, anodised and fixed complete all as specified and directed by Engineer-in-charge
S&F of mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, Length of bolt 200 mm complete all as specified and directed by Engineer-in-charge
S&F of Mild steel pressed handles,150mm oval type, stove enamelled black complete all as specified and directed by Engineer-in-charge
S&F of mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, Length of bolt 300 mm complete all as specified and directed by Engineer-in-charge
S&F of Butt hinges of 100 mm size, Medium weight, cold rolled mild steel and fixed complete all as specified and directed by Engineer-in-charge
S&F of door stopper of aluminium alloy body and tongue 150 mm long , anodised fixed in door with screws etc complete all as specified and directed by Engineer-in-charge
S&F of 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-charge
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregates as in filling of hold fast etc complete all as specified and directed by Engineer-in-charge
M&L for Cutting holes in brick walls in cement mortar or cement lime mortar and stone wall built in lime mortar for inserting holdfasts in exc. One brick but not exc. two brick wall and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed by Engineer-in-charge
M&L for framed work such as grills gratings, sunshed cover fixed with nut bolts incl,cutting drilling holes etc., with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed baluster, walk ways, railings, framedwork or water tanks and similar work conforming to Fe 290 gde E 165 complete all as specified and directed by Engineer-in-charge
M&L for Steel work in tubular trusses/purlins/posts (of round/rectangula/square hollow section) including angle cleats for jointing with welding confirming to IS.1161- 1979 grade St.-240 complete all as specified and directed by Engineer-in-charge
Hacking out old broken glass (any thickness, size,quality or description) from wooden / steel frames glazed with oil putty or fixed with beads complete all as specified and directed by Engineer-in-charge
S&F of 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer-in-charge
S&F of 3 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer-in-charge
S&F of 110mm dia PVC(SWR) pipes single soketed in any length with rubber ring jointed fixed to wall or laid in trenches including ms clamps, including taking up and down old pipes complete all as specified and directed by Engineer-in-charge
S&F of PVC (SWR) bends 110 mm dia, including taking out old bends complete all as specified and directed by Engineer-in-charge
S&F of PVC (SWR) 110 mm dia junction, single(single 'T') equal or unequal, including taking out old Tee complete all as specified and directed by Engineer-in-charge.
S&F of PVC(SWR) vent cowl of 110mm dia, including taking out old cowl complete all as specified and directed by Engineer-in-charge
S&F of PVC (SWR) pipes 75mm bore single socketed, in any length with solvent joints fixed to wall or laid in trenches or in floors, including taking up and down old pipes complete all as specified and directed by Engineer-in-charge
S&F of PVC (SWR) bends 75mm dia, including taking out old bends complete all as specified and directed by Engineer-in-charge
S&F of PVC(SWR) vent cowl of 75mm dia, including taking out old cowl complete all as specified and directed by Engineer-in-charge
S&F of 75 mm dia PVC ( SWR) floor trap with grating including jointing with solvant etc, including taking out old trap complete all as specified and directed by Engineer-in-charge
S&F of 25 mm dia aluminium powder coated droppery rod including brackets, including taking out old rod with brackets complete all as specified and directed by Engineer-in-charge
S&F GI tubing 15 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors including taking down 15 mm dia GI tubing and connections complete all as specified and directed by Engineer-in-charge
S&F GI tubing 20 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors including taking down 20mm dia GI tubing and connections complete all as specified and directed by Engineer-in-charge
Taking down 15 mm dia GI tubing and connection and refixing old 15mm GI tubing and connection in new or old position ( wall, floor, wall etc ) complete all as specified and directed by Engineer-in-charge
Taking down 20 mm dia GI tubing and connection and refixing old 20mm GI tubing and connection in new or old position ( wall, floor, wall etc ) complete all as specified and directed by Engineer-in-charge
Cutting and screwing to existing steel tubing for alterations or additions (Each cut measured) 15 /20 mm pipe complete all as specified and directed by Engineer-in-charge
S&Fof PVC float valve assembly including assessories with float valve 20mm dia (Make prayag), including taking out old float valve assembly complete all as specified and directed by Engineer-in-charge
S&F of soap dish brass chromium plated fixed to wall with brass chromium plated screw and wooden/ plastic plug etc, including taking out old soap dish complete all as specified and directed by Engineer-in-charge
S&F of Wash hand basin mixture 15mm bore cast copper alloy, with capstan heads, chromium plated, screwd down high pressure, with lettered 'hot' or 'cold' with long screwed shanks and fly-nuts, screwed for iron pipes and fixed, including taking out old mixture complete all as specified and directed by Engineer-in-charge
S&F of CP hot & cold water wall mixure unit with arrangement for overhead shower and with hot & cold valves cast copper alloy type heavy duty fixed to 15mm bore of pipe, including taking out old mixture complete all as specified and directed by Engineer-in-charge
S&F of 2 way bib cock with single knob 15mm dia chromium plated, cast copper alloy, including taking out old 2 way bib cock complete all as specified and directed by Engineer-in-charge
S&F of health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, including taking out old faucet complete all as specified and directed by Engineer-in-charge
S&F of C P bib taps, cast copper alloy fency conceled type with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule of 15 mm boreand fixed, including taking out old bib tap complete all as specified and directed by Engineer-in-charge
S&F of angular stop valve , 15mm dia, cast copper alloy,CP fancy type with long shank and cup screwd down, high pressure ,screwed both ends for iron pipes or for unions and fixed in pipe, including taking out old stop valve complete all as specified and directed by Engineer-in-charge
S&F of Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe, including taking out old gate valve complete all as specified and directed by Engineer-in-charge
S&F of bib tap standard of PTMT any colour high pressure screwed for iron pipe of 15 mm bore and fixed (Minimum weight 15mm 90gm), including taking out old bib tap complete all as specified and directed by Engineer-in-charge
S&F of pillar taps, fancy type cast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered “hot” or “cold” with long screwed shanks and fly nut screwed for iron pipe of 15mm bore fixed, including taking out old pillar tap complete all as specified and directed by Engineer-in-charge
S&F of PTMT PVC grating of 100 mm dia fixed, including taking out old grating complete all as specified and directed by Engineer-in-charge
S&F of brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges as fixed, including taking out old towel rail complete all as specified and directed by Engineer-in-charge.
M&L for vitreous china WHB white flat back size 550x400mm including S&F angle iron brackets, C.P pillar tap fency type 01 No 15mm bore, CP waste coupling, 32mm dia and PVC waste pipe 32mm dia and PVC connection 450mm long high pressure complete, including taking out old WHB with all accesories complete all as specified and directed by Engineer-in-charge.
M&L for vitreous china squatting pan 'Orrisa pattern' size 580x440mm white with integral foot rests any pattern including provn of cement concrete bedding and making connection with & including Pors Trap etc complete, including taking out old squatting pan with all accesories complete all as specified and directed by Engineer-in-charge.
M&L for Vitreous China wash down water closet pan (pedestal pattern), white including white seat cover complete, including taking out old water closet pan with all accesories complete all as specified and directed by Engineer-in-charge
S&F of Brass CP bottle traps 40mm bore for wash basins with inlet & outlet screwed for pipe or connections including necessary packing, union & cap, including taking out old trap complete all as specified and directed by Engineer-in-charge
S&F of Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x420mm with bowl size 410mm x330mm x160mm, including taking out old sink with all accesories complete all as specified and directed by Engineer-in-charge
S&F of sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste pipe including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, including taking out old sink with all accesories complete all as specified and directed by Engineer-in-charge
S&F of PVC low level flushing cistern of 10 Ltr capacity including flushing pipe bend PVC bend etc complete, including taking out old cistern with all accesories complete all as specified and directed by Engineer-in-charge
S&F of Tolilet paper holder, vitreous China white, box type to walls with CP (CP) brass screws, including taking out old Tolilet paper holder complete all as specified and directed by Engineer-in-charge
S&F of Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long complete, including taking out old Sheet glass shelf assembly complete all as specified and directed by Engineer-in-charge
S&F of Rotational moulded polyethylene water storage tanks capacity 1000 litres (cylindrical vertical with closed top) hoisted and fixed in position with and including 20mm bore float valve complete, including dismantling old 1000L water tank complete all as specified and directed by Engineer-in-charge
S&F of Rotational moulded polyethylene water storage tanks capacity 500 litres (cylindrical vertical with closed top) hoisted and fixed in position with and including 20mm bore float valve complete, including dismantling old 500L water tank complete all as specified and directed by Engineer-in-charge
M & L for PCC ( 1: 2: 4) type B-0 using (12.5mm graded stone aggregate) etc on roof top as a leveling course / padding to maintain the slope,finished the surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
Taking down of old roof treatment of any description including demolition of mud phushka, lime, concrete, tiles , cement plaster, padding upto 30cm depth from roof surfaces etc including cleaning, brushing and watering to joints and grooves and throwing the same to a distance exc 250 mtr and n exc 500 mtr from the roof of height 3 to 9 m height etc and applying new water proofing roof treatment to RCC roof with approved modified membrane of weighing not less than 3 kg/sqm comprising with following items with and including materials and labour as under:- (i) The surface of roof,parpet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting. For cast iron drain outlets a groove shall be cut as specified and directed. A fillet of PCC (1:2:4) of 100x100mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of dirction. The membrane should not be taken over at any steep turns and hence all corners/timers should be rounded. (ii) Rendering 10 mm thick in cement mortar 1:4 mixed with and including water proofing compound @ 3% by weight of cement applied over roof slab ,complete all as specified and directed. (iii) Oil based Bitumen primer conforming to IS-3384-1986 @ 0.3 kgs per sqm to be applied on prepared surface till the surface is properly impregnated. (iv) Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm (v) Laying of water proofing teratment of weight not less than 3 Kg / sqm APP modified polymeric water proofing membrane composed of 100 micron (+10% ) high density polyethylene sheet ( HMHDPE) as center core, which is standwiched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps 75 mm and 100 mm as per manufacture instruction etc. (vi) Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm over the membrane. (vii) Applying aluminium paint in two coat @ 100 gm/sqm in each coat on finished membrane surfaces complete all as specified and directed at site .
Taking down of old roof treatment of any description including demolition of mud phushka, lime, concrete,tiles , cement plaster, padding upto 30cm depth from roof surfaces etc including cleaning, brushing and watering to joints and grooves and throwing the same to a distance exc 250 mtr and n exc 500 mtr from the roof of height 3 to 9 m height etc and applying new water proofing roof treatment to RCC roof with approved modified membrane of weighing not less than 3 kg/sqm comprising with following items with and including materials and labour as under:- (i) The surface of roof,parpet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting. For cast iron drain outlets a groove shall be cut as specified and directed. A fillet of PCC (1:2:4) of 100x100mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of dirction. The membrane should not be taken over at any steep turns and hence all corners/timers should be rounded. (ii) Rendering 10 mm thick in cement mortar 1:4 mixed with and including water proofing compound @ 3% by weight of cement applied over roof slab ,complete all as specified and directed. (iii) Oil based Bitumen primer conforming to IS-3384-1986 @ 0.3 kgs per sqm to be applied on prepared surface till the surface is properly impregnated. (iv) Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm (v) Laying of water proofing teratment of weight not less than 3 Kg / sqm APP modified polymeric water proofing membrane composed of 100 micron (+10% ) high density polyethylene sheet ( HMHDPE) as center core, which is standwiched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps 75 mm and 100 mm as per manufacture instruction etc. (vi) Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm over the membrane. (vii) M&L for cement concrete tiles 25cm x 25cm x 22mm thick,with grey cement and no pigment, machine pressed; set, jointed and pointed in neat cement slurry at top surface, and cut and polished over and including 15 mm screed be in cm (1:4)
M&L for treatement for sunken portion is as follows :- (a) Demolition of lean concrete and other type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed. (b) M&L for water proofing plaster for sunken portion in CM 1:3, 20 mm thick in two coats with water proofing compound at the rate of 2% by weight of cement and finishing the surface even and smooth without using extra cement. (c) M&L for applying two coats of Dr fixit compound suitable for sunkun treatment as per manufacturer instructions over vertical surfaces and floors of sunken of toilet including cleaning of surfaces. (d) M&L for PCC 1:7:12 type D2 using 40 mm graded stone aggregate as in filling (sunken portion) (e) M&L for PCC 1:2:4 type B0 using 12.50 mm graded stone aggregate, mixed with WPC @ 2% by wt. of cement, as sub base, 75mm thick on top. Note :- Above quoted rate includes :- (a) Test again of water tightness by pounding for 72 hours & rectify defects if any till total elimination of defect. (b) The sunken portion shall be tested for leakage / seepage / dampness by ponding with water for 72 hours. In case any defect is noticed the portion shall be grouted with Dr fixit suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated (c) Horizontal flat area to be measured.
Taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor etc complete all as specified and directed by Engineer-in-charge.
M&L for point wiring with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing -n-caping /conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed by Engineer-in-charge. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
For one light point or fan point controlled by one switch.
For one Call Bell point controlled by one push button switch.
For 5Amp independent socket point controlled by one switch.
For one 3 pin ,5 Amp socket point with other switch on the same board.
M&L for power point wiring with 2.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing -n-caping /conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed by Engineer-in-charge. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
M&L for concealed point wiring with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows, etc. all as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge . Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
For one light point or fan point controlled by one switch.
For one Call Bell point controlled by one push button switch.
For 5Amp independent socket point controlled by one switch.
For one 3 pin ,5 Amp socket point with other switch on the same board.
M&L for concealed power point wiring with 2.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows, etc. all as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 2.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge . Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
S&F of Modular switch, one way,6 Amp 230, 1 module complete all as specified and directed by Engineer-in-charge.
S&F of modular socket 6 Amp-2/3 pin combined 2 module complete all as specified and directed by Engineer-in-charge.
S&F of Modular switch, one way,6 A/16 Amp 230, 1 module complete all as specified and directed by Engineer-in-charge.
S&F of modular socket 6 A/16-2/3 pin combined 2 module complete all as specified and directed by Engineer-in-charge.
S&F of Modular fan step regulator 120 Watt -2 module complete all as specified and directed by Engineer-in-charge.
S&F of Modular bell push 6A one module complete all as specified and directed by Engineer-in-charge.
S&F of switch piano type flush, single pole, one way 5 A 230 V complete all as specified and directed by Engineer-in-charge.
S&F of socket outlet, 5 pin, 5 Amp, flush type, 230 V complete all as specified and directed by Engineer-in-charge.
S&F of switch piano type flush, single pole, one way 15 A 230 V complete all as specified and directed by Engineer-in-charge.
S&F of socket outlet 2 in 1,6 pin, 5/15 A, flush piano type 240 V complete all as specified and directed by Engineer-in-charge.
S&F of ceiling rose, surface bakelite,three terminal complete all as specified and directed by Engineer-in-charge.
S&F of lamp holder insulated with back plate suitable for Angle/Batten fitting complete all as specified and directed by Engineer-in-charge.
S&F of bell ding dong 230 V, single phase complete all as specified and directed by Engineer-in-charge.
S&F of electronic double space rotary 5 speed type regulator 120-280 V complete all as specified and directed by Engineer-in-charge.
S&F of bell push flush type one way 5Amp 240 Volt complete all as specified and directed by Engineer-in-charge.
M&L for sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 4 sqmm (for main current) drawn in & incl PVC Casing-n-caping of suitable size ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 4 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green, incl. taking down old unserviceable sub main wiring complete all as directed by Engineer-in-Charge. Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. (ii) Two runs of single core for main current and one run of single core for earth continuity conductor & one run of PVC Casing-n-caping shall be measured as one unit length.
M&L for surface conduit sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 6 sqmm (for main current) drawn in & incl PVC casing -n-caping/pvc conduit of suitable size not less than 20mm dia ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green, incl. taking down old unserviceable sub main wiring complete all as directed by Engineer-in-Charge. Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. (ii) Two runs of single core for main current and one run of single core for earth continuity conductor & one run of PVC casing -n-caping/pvc conduit shall be measured as one unit length.
S&F of testing and commissioning of MCB SP 240 volt 6 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs etc complete all as specified and directed by Engineer-in-charge.
S&F of testing and commissioning of MCB SPN 240 volt 16 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs etc complete all as specified and directed by Engineer-in-charge.
S&F of sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar etc, including taking down existing DB complete all as specified and directed by Engineer-in-charge. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
S&F of double door metallic sheet metal enclosure for DB double door(IP-42/43) When MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar etc, including taking down existing DB complete all as specified and directed by Engineer-in-charge. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
S&F of LED Bulk head 13/10 watt designed for modern homes available in PIR as well as non PIR sensor with premium quality diffuser for glarefree light and easy to install snapfit installer complete all as specified and directed by Engineer-in-charge.
S&F of TL fitting 20 watt for surface and wall mounted LED batten with ultra slim polycarbonate LED lighting fixture with high lumen output environmental friendly energy efficient complete all as specified and directed by Engineer-in-charge.
S&F of box type LED optic fitting 10/9 Watt 2 feet box type complete all as specified and directed by Engineer-in-charge.
S&F of Modular AC box enclosure with socket plug top and MCB SP 25 Amps flush mounting enclosure etc, including taking down existing AC box complete all as specified and directed by Engineer-in-charge. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.
v k builder
M K Construction
HAFEEZ CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .