| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.7 L+₹74,230 (15.0%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L2 | Rejected-Finance L2 | |
| 3 | L3₹5.8 L+₹80,158 (16.2%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹7.8 L+₹2.8 L (56.6%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹9.2 L+₹4.2 L (85.6%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
28 Nov 2020, 6:00 pmClosed
GE AF FARIDABAD
Garrison Engineer AF Faridabad Dabua Colony Faridabad Haryana Pin-121005
REPAIR REPLACEMENT OF INTERNAL WIRING REPAIR TO GEYSERS FITTINGS FIXTURES MAIN DISTRIBUTION BOARDS LIGHT FITTINGS ACCESSORIES IN OMQ AND SMQ AREA AT AF STN FARIDABAD
2020_MES_390366_2
GE (FBD)/AF-24/2020-2021
Open Tender
Civil Works
Item Rate
180 days
AF STATION FARIDABAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF FARIDABAD
₹19,000
Yes
25 Jan 2021
13 Nov 2020
30 Nov 2020
13 Nov 2020
28 Nov 2020
16 Nov 2020
Amount
Taking down copper/aluminum point wiring (light, fan, socket on power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engr-in-charge
Taking down carefully copper / aluminum two core sub main wiring of any size Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed by Engr-in-charge
Taking down carefully copper / aluminum two core sub main wiring of sizes 4 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed by Engr-in-charge
M&L for point wiring in complete with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including rigid non metallic PVC heavy duty concealed conduit(min 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.12.5 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends.tees, juction boxes etc fixed concealed in wall/ceiling or surface conduit on ceiling with provision of 2 mm thick pressed steel terminal boxes covered with 3 mm thick plastic laminated white /coloured top cover for mounting switch,socket,fan regulator,industrial socket and all lamp fittings etc including 1.5 sq mm PVC insulated but unsheathed copper conductor FRLS cable,1100 volt grade IS-694 marked as earth contuinity wire for one light point/Fan point controlled by one,one way switch complete all as specified and directed by Engr-in-charge
All as per Item No 4 mentioned here-in- before but one three pin 5/6 Amps socket out let on the same board with other switches with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and directed by Engr-in-charge
All as per item No 4 mentioned here-in- before but one three pin 5/6 Amps socket out let on independant board with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and directed by Engr-in-charge
All as per item No 4 mentioned here-in- before but 15/16 Amps 3 pin socket outlet on independent board with 2.5 sq mm PVC insulated and sheathed copper conductor with 2.5 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engr-in-charge
All as per item No 4 mentioned here-in- before but for Single pole and neutral enclosure with 4.0 sq mm PVC insulated and sheathed copper conductor with 4 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engr-in-charge
S&F Piano switch in flush button,single pole,one way 5/6 Amp complete all as specified and directed by Engr-in-charge.Make- Anchor/Plaza/Havells.
S&F piano switch,in flush button single pole one way 15/16 Amp complete all as specified and directed by Engr-in-charge.
S&F bell push, in repairs, flush type 5/6 Amps complete all as specified and directed by Engr-in-charge. a
S&F socket outlet, in flush type 2 in 1, 2 pin and 3 pin 5/6 Amp complete all as specified and directed by Engr-in-charge.
S&F socket outlet, in flush type 2 in 1, 3 pin and 5/15 Amp complete all as specified and directed by Engr-in-charge
S&F stepped type electronic fan regulator, in flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engr-in-charge.
S&F in ceiling rose surface backlight, 65 x 50 mm two to to three terminals complete all as specified and directed by Engr-in-charge
S&F lamp Angle holder, in repairs, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engr-in-charge .
S & F in repairs,Bell ,Bell Multi Music type,240 V, complete all as specified and directed by Engr-in-charge.
S&F in sheet metal enclosure for MCB DB's SPN 240 volts, 8 way with neutral bus bar 200 Amp rated double door type regal grey all as specified and directed by Engr-in-charge.
All as mentioned in item No 18 here in above but 12 ways DBs complete all as specified and directed by Engr-in-charge
All as mentioned in item No 18 here in above but TPN, 4 ways DBs complete all as specified and directed by Engr-in-charge
S&F in repairs,Single pole and neutral enclosure with a two pin and earth plug and socketcomplete with one single pole MCB 32 Amp complete all as specified and directed by Engr-in-charge.
M&L in repairs,two single core PVC insulated cable with copper conductor multi stranded 6 Sqmm duly drawn through and including concealed PVC conduit suitable size as sub main with continuous earth wire 6 Sqmm size and connecting to common earth dolly all as specified and directed by Engr-in-charge.(Flexible Copper Wire Used In FRLS)
All as per item No 22 mentioned here-in- before but 4.0 sq mm PVC insulated and sheathed copper conductor with 4 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engr-in-charge.
S&F in repairs MCB SP 6 to 32 Amps 240 Volts."C" grade complete all as specified and directed by Engr-in-charge.
S&F in repairs MCB,SP 40 Amps, 240 Volts."C" grade complete all as specified and directed by Engr-in-charge. .
S&F in repairs MCB,SPN 6-32 Amps, 240Volts,"C" grade complete all as specified and directed by Engr-in-charge.
S&F in repairs MCB SPN, 40 Amps, 240Volts ."C" grade complete all as specified and directed by Engr-in-charge.
S&F in repairs MCB SPN, 63 Amps, 240Volts."C" grade complete all as specified and directed by Engr-in-charge.
S&F in repairs MCB TPN 40 Amps,415Volts ."C" grade complete all as specified and directed by Engr-in-charge..
S&F in repairs MCB TPN, 63 Amps,415Volts ."C" grade complete all as specified and directed by Engr-in-charge..
S&F in repairs LED bulb 10 watt base cap B- 22/E 14/E 27 cool day lamp candle type complete all as specified and directed by Engr-in-charge..
S&F in repairs LED bulb 15 watt base cap B- 22/E 14/E 27 cool day lamp candle type complete all as specified and directed by Engr-in-charge.
S&F in repairs,LED tube light batten,22W LED,6000K (4 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed by Engr-in-charge
S&F in repairs,LED tube light batten,12W LED 6000K (2 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed by Engr-in-charge
S&F in repairs Recessed, Bottom Opening Energy Saving Cleanroom,1x45W LED false ceiling panel fittings extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed by Engr-in-charge
Taking down storage water heater 25/50 ltrs capacity from wall for repair/replacement of unserviceable parts and refixing with fasterners Nuts and washers the same after repair work complete all as specified and as directed by Engr-in-charge
M&L for replacement of thermostate 0-60 degree as per sample in water geyser 25/50 litre capacity ISI complete all as specified and directed by Engr-in-charge.
M&L for replacement of heating element 1.5KW,Triangular/round type as per sample complete all as specified and directed by Engr-in-charge.
M&L for replacement of heating element 2 KW Triangle/Circular type as per sample complete all as specified and directed by Engr-in-charge.
M&L for replacement of geyser assembly complete 6/9 hole with all connected accessories such as gasket,valve provision of fixing thermostat accessories complete all as specified and directed by Engr-in-Charge
Supply only split plate for 25 litrs capacity geyser as per site requirement and made out of 20 gauge MS sheet complete all as specified and directed by Engr-in-charge.
Supply only geyser inner tank made out of stainless steel sheet conforming to I.S. for 25 ltrs capacity geyser complete all as specified and directed by Engr-in-charge.
Supply only geyser bottom cover made out of 20 SWG MS sheet, duly painted with one coat of red oxide primer and two coat of first quality super enamalled white paint complete all as specified and directed by Engr-in-charge for 25 liters capacity geyser.
M&L for replacement of geyser outer body cover of 25 Ltr capacity made out of 20 SWG MS Sheet, duly painted with one coat of red oxide primer and two coat of first quality super enamalled light white paint complete with all connected accessories suitably fitted with existing wall all as specified and directed by Engr-in-Charge.
M&L for painting of geyser outer with two coat of synthetic enamel paint of approved colour including scraping out old paint of surface and preparation and writting of MES No complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of geyser tank stainless steel suitable for 25 Ltr capacity geyser complete all as specified and directed by Engr-in-Charge
M&L for replacement of PVC connection with brass inserts suitable for hot/cold water, 60 cm long having nuts with washer complete all as specified and as directed by Engr-in-Charge.
Dismantling and opening storage tank of geyser 25/50 litre capacity to identify the leakage ,repair the spot by suitable welding carefully including making good insulating material, assembling and testing complete all as specified and as directed by Engr-In-Charge.
S&F FR PVC electrical insulation tape,1.8 cm x 25 mtr x0.125 mm thick complete all as specified and directed by Engr-in-charge.
S&F three core PVC insulated and over all PVC round cable of size 2.5 Sqmm 40/0076 with stranded copper conductor complete all as specified and directed by Engr-in-charge.
S&F plug top 3 pin 16 Amps capacity heavy duty in repair complete all as specified and directed by Engr-in-charge.
Dismantling/opening ceiling fan and removing capacitor, complete checking of bearings/bushes, cleaning the fan blades with clear water, scrapping the fan blades, replacing the bearing, bush, capacitor, rewinding complete (rewinding, bush, bearing, capacitor, twin core flexible cable, downrod, hanging clamps, PVC conopy will be paid under relevant item of the Sch) reassembling the ceiling fan complete after greasing, oiling testing the same making the fan serviceable all as specified and directed by Engineer-in-Charge of 1200 mm sweep.
All as per Sl Item No. 53 here-in-before but for exhaust fan 450mm sweep metal body complete all as specified and directed by Engr-in-charge.
All as per Sl Item No. 53 here-in-before but for exhaust fan 300/250 mm sweep complete all as specified and directed by Engr-in-charge.
Rewinding of ceiling fan with required gauge super enamalled copper wire including varnishing, insulation taping complete of 1200 mm sweep complete all as specified and directed by Engr-in-charge.
Rewinding of exhaust fan with required gauge super enamalled copper wire including varnishing, insulation taping complete of 450 mm sweep complete all as specified and directed by Engr-in-charge.
Rewinding of exhaust fan with required gauge super enamalled copper wire including varnishing, insulation taping complete of 300/250 mm sweep complete all as specified and directed by Engr-in-charge.
Supply only fan capacitor 2.5 mfd make universal / Asian/Epcos/Tibcon or equivalent as approved by GE complete all as specified and directed by Engr-in-charge.
Supply only fan capacitor 3.5/4 mfd make universal / Asian/Epcos/Tibcon or equivalent as approved by GE complete all as specified and directed by Engr-in-charge.
Saini Enterprises
M/s Krishna Construction Co.
Parveen Builders
airstack india
M/S Davinder Kumar
M/S Satyam Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .