| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Responsive |
| 2 | Accepted-Technical | Accepted-Technical Responsive |
| 3 | Rejected-Technical 67 AASANI BAS PALANA PALANA BIKANER BIKANER RAJASTHAN 334402 UDYAM RJ 08 0063520 | BIKANER | RAJASTHAN | 334402 | Rejected-Technical Non Responsive |
Tender Value
₹5.9 Cr
EMD Value
₹31.7 L
Closing Date
27 Jan 2026, 12:00 pmClosed
Office of the SE 17th (E/M) Circle, PWD, Lucknow
Office of the SE 17th (E/M) Circle, PWD, Lucknow
Janpad Lucknow mein Lucknow-Kursi-Mahmudabad Marg ke KM 9 se Madiyaon Shukla Chaurahe tak (Length 2.900km) Chaudikaran evam Shudranikaran ka karya (Vidyut utility shifting)
2026_CEEMP_1106335_2
53/4CBW-17EM/2026 Date 08-01-2026
Open Tender
Electrical Works
Percentage
180 days
Lucknow
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,354
Executive Engineer Ty.Mech. Div.-2,PWD, Lucknow
₹31.7 L
Office of the SE 17th (E/M) Circle, PWD, Lucknow
23 Mar 2026
14 Jan 2026
27 Jan 2026
14 Jan 2026
27 Jan 2026
14 Jan 2026
20 Jan 2026
(PART -A for 11 KV LINE under ground) S/O Al. (3x185) sqmm XLPE 11 KV
S/O Cable Jointing kit straight through 11 KV 3Cx185 sqmm
S/O Cable Jointing kit outdoor through 11 KV 3Cx185 sqmm
Supply of ABC Cable (3x120+1x95+1x16) sqmm
Supply of HDPE 120 mm
DP Structure with STP Annexure DP for 11 KV
Supply of GI Pipe 6 inch dia
S/O Material for shiffting of existing transfarmer 16 KVA, 25 KVA , 63 KVA & 100 KVA
S/O Material for shiffting of existing transfarmer 250 KVA Transformer
11KV 3x185 sq mm Cable laying by HDD
11 KV high pressure Testing
Labour Charges @ 30% of Part A SI.No. (1-9) (Item No.-1 is taken -1000 mtr) Dismentling of old line / material and Deposit to Store including cartage Erection with T&P Laying, Testing & Commissioning etc.(Amount 6711097.00)
(PART- B for 33 KV) S/O Al. (3x300) sqmm XLPE 33 KV
S/O 33 KV 3x300 sq mm XLPE Cable Jointing Kit Straight through
S/O 33 KV 3x300 sq mm XLPE Cable Jointing Kit Outdoor
S/O GI Pipe 6" Dia
S/O DP Structure with STP Annexure DP of 33 KV
S/O Aluminium Paint
S/O Red Oxide Paint
S/O Concreating of Pole
11KV 3x300 sq mm Cable laying by HDD
33 KV high Pressure Testing
Labour Charges @ 30% of Part B SI.No. (12-19) (Item no-12 is taken -1940 mtr) Dismentling of old line / material and Deposit to Store including cartage Erection with T&P Laying, Testing & Commissioning etc.(Amount 8867144.00)
GST @ 18% Extra
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
cancelled_1.pdf
pdf • 0.50 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.95 MB
BOQ_2041274.xls
BOQ • 0.32 MB
2T2KursiMahmudabad53.pdf
Tender Documents • 14.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].