Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.7 LAccepted-Finance | 1 | Accepted-Finance accepted | |
| 2 | Rejected-Technical | - | Rejected-Technical Rejected |
Tender Value
₹19.2 L
EMD Value
₹19,200
Closing Date
23 Sept 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Officer
No.7 Car Street Sriperumbudur Town Panchayat
Improvement works at new complex building in ward no.7 at Sriperumbudur Town Panchayat
2024_DTP_484631_1
3.Sivanthangal
Open Tender
Civil Works - Others
Works
90 days
Sriperumbudur Town Panchayat
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹19,200
Yes
21 Nov 2024
16 Sept 2024
23 Sept 2024
16 Sept 2024
23 Sept 2024
16 Sept 2024
Amount
Earth work excavating and depositing on bank with initial lead of 10 m & initial lift of 2m in Hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders SS.20B (ScH.No.62) (P.No.22)
Refilling the excavated earth including watering and consolidation layer by layer with all incidental charges etc complete
Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
Centering with Steel Plates including strutting,lining and levelling etc complete. Footing & Grade beam
column and Beams
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -
Supply and fabrication of RTS rods in various dia including cutting and bending etc
Brick work in cement mortar 1:5 mix (one cement five sand) using II class table molded bricks chamber burnt bricks of size 9" X 4 1/2" X 3" for the following including curing etc., completed.
Filling with Well Gravel including watering and consolidation layer by layer with all incidental charges etc complete
Plastering for brickwork surfaces using cement mortar 1:5 (One part of cement, Five parts of sand by volume) thickness 12mm (average) for all internal/external surfaces like superstructure, rainwater ducts, elevation fin walls, manholes, inspection chambers, entrance & staircase steps etc., finished smoothly to one level including scaffolding, curing etc., complete, at all leads and at all heights.
Plastering for brickwork surfaces using cement mortar 1:3 (One part of cement, three parts of sand by volume) thickness 10mm (average) etc complete as per the direction of departmental officer
Fixing of Steel rolling shutters including cost and conveyence to work site and labour cherges etc complete
Painting with first quality emulsion paint two coats over a priming coat including thorough cleaning, scrapping, removal of dust and including necessary plaster of paris putty works wherever required etc., completed.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light / fan Point (for electronic regulator) (5 points per coil)
Supply and Run of 2 of 4 sq.mm (56/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable heavy gauge M.S. conduit pipe concealed in wall and ceiling with continuous earth Wire connection by 14 SWG TC wire and making good of the concealed portion wiith suitable colour (SD 45)
Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 14 SWG TC wire with painting of suitable colour.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15A 3 pin non inter locking wall socket with 15A flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed power plug point
Supply and fixing of box type 4' 40W flourescent tube wiring complete with copper choke and condenser with TW round blocks on wall or ceiling with flurescent tube with PVC un sheathed copper leads from terminals to the fitting
Supply and fixing of 1200mm ac ceiling fan complete with elapsed electronics 300W regulator with 300mm down red on the existing clamp
Weathering course in concrete broken stone brick jelly 20mm size in pure slacked lime over RCC slab. The proporation being 32:12:5 for requuired slope and the thickness of roof as required and well beaten with wooden beaters etc., completed
Terrace flooring with one couse of pressed tiles of size 23 X 23 in cement mortar 1:3 mix with impermo oil 2% by weight of cement and pointed with same oiled mortar
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
M/S.VASANTHAM ENTERPRISES (BID ID -1144103)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .