Executive Engineer University of Kashmir
Construction Division
Electrical Works of Volleyball, Badminton and Basketball Courts at Main Campus.
2021_UDJK_147500_1
F(UCD)(Elect. works Sports)/KU/58/21
Open Tender
Electrical Works
Item Rate
30 days
Main Campus
As per NIT
7 documents required · 7 mandatory
₹200
Registrar University of Kashmir
Exempted
22 Nov 2021
11 Nov 2021
22 Nov 2021
11 Nov 2021
20 Nov 2021
11 Nov 2021
120 days
Amount
Supply, installation, testing and commissioning of sub main control M.V. cubicle type totally enclosed standing type out door type, dust, damp and vermin proof M.V. danger notice plate panel be cement grouted properly, connection of incoming and outgoing cables with thimbles, stove enameled painted and having following incoming/ outgoing, indicators and bus bar arrangements complete as required. with extra space for 4 MCB's a) 1no. 100 Amp. 2 pole 25KA MCCB b) 1 set 100 Amp busbar 2pole strip heavy duty aluminum basbar.
Supply, laying, fixing including excavation and proper backfill of following size ISI marked aluminium conductor XLPE insulated cable as per IS 7098, un armoured, served, sheathed 1100 volts grade. 2 core 25 sq.mm
Supply, laying, fixing including excavation and proper backfill of following size ISI marked aluminium conductor XLPE insulated cable as per IS 7098, un armoured, served, sheathed 1100 volts grade. 2 core 16 sq.mm
Supplying and Erection of Steel Tubular poles (8m) complete with base plate & top cap for tapping point including drilled holes for supporting channel including carriage chargers, loading/unloading and Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling i/c Painting of poles with primer coat/paint coat
Suppying,fabricating in proper way, fixing of flood light holding bracket (3 row 4ft x 2 ft ) of 60mmx35mmx5mm C- chanel with suitable braces, nuts,bolts and light fixing arrangement should have movement adjustmet of 45 degree arrnagements for six lights. the frame should be duly paint coated, as per approval of EIC.
Supply, installation, Testing and Commissioning of 150 Watt high efficient LED flood lights having min 110 Lm/Watt, IP66 protection, LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V. The The LED Driver shall be of isolated type with Constant Current & APFC topology to ensure optimum driving of LEDs. The LED Driver shall have minimum 3KV of surge protection. The LED Flood Light shall have power factor more than 0.9 with THD less than 10%. LED Driver Output voltage shall be less than SELV Limits for safe operation and maintenance. The luminaire shall be complete IP66 protection for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety. The LEDs in LED Flood Light shall use multiple LEDs to get sufficient light output from the luminaire. Complete in all respects sample shall be approved by engineering wing before use.
Supply, installation, Testing and Commissioning of 120 Watt high efficient LED flood lights having min 110 Lm/Watt, IP66 protection, LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V. The The LED Driver shall be of isolated type with Constant Current & APFC topology to ensure optimum driving of LEDs. The LED Driver shall have minimum 3KV of surge protection. The LED Flood Light shall have power factor more than 0.9 with THD less than 10%. LED Driver Output voltage shall be less than SELV Limits for safe operation and maintenance. The luminaire shall be complete IP66 protection for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety. The LEDs in LED Flood Light shall use multiple LEDs to get sufficient light output from the luminaire. Complete in all respects sample shall be approved by engineering wing before use
Supply, installation, Testing and Commissioning of 100 Watt high efficient LED flood lights having min 110 Lm/Watt, IP66 protection, LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V. The The LED Driver shall be of isolated type with Constant Current & APFC topology to ensure optimum driving of LEDs. The LED Driver shall have minimum 3KV of surge protection. The LED Flood Light shall have power factor more than 0.9 with THD less than 10%. LED Driver Output voltage shall be less than SELV Limits for safe operation and maintenance. The luminaire shall be complete IP66 protection for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety. The LEDs in LED Flood Light shall use multiple LEDs to get sufficient light output from the luminaire. Complete in all respects sample shall be approved by engineering wing before use
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. .Legrand/ Siemens/ABB make. single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. .Legrand/ Siemens/ABB make. Double pole
Providing and fixing of pole mount MCB box of suitable size as per directions of EIC
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable 2 X 1.5 sq. mm
Supplying and laying 8 SWG G.I. wire including connection/ termination with GI thimble etc. as required.
R.R. Builders
stage.html
html • 0.02 MB
finance_319315.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .