Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.5 L+₹6.6 L (22.8%)Rejected-Finance 11 1 7 P D KYDGANJ PRAYAGRAJ U P PIN 211003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹37.2 L+₹8.3 L (28.9%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
₹32.5 L
EMD Value
₹65,100
Closing Date
25 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad.
Addition/ Alteration cum spl repair to certain bldg. at Old Cantt Prayagraj and provn of pathway with interlocking tile to KV School and AMWP, MW work at Varanasi Cantt Under GE (East) Prayagraj.
2023_MES_583270_1
8613/E8
Open Tender
Civil Works
Item Rate
180 days
Prayagraj
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE (East) Allahabad
₹65,100
Yes
26 Apr 2023
27 Feb 2023
27 Mar 2023
27 Feb 2023
25 Mar 2023
13 Mar 2023
Amount
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Brickwork with flyash bricks, straight or curved on plan exceeding 6 metre mean radius, built in CM 1:6, complete all as specified and directed.
Dismantling floor, hearth or brick tiles including cement mortar bedding but not backing, removing serviceable tiles to store, removing rubbish off the premises, complete all as specified and directed.
Non - skid Ceramic, coloured tiles 7 to 8 mm thick, area of each tile shall exceeding 0.11 Sqm but not exceeding 0.18 Sqm, as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, laid over and including provision of 15 mm thick screed bed or bedding layer in CM 1:6 for laying floor finish, complete all as specified and directed.
Glazed coloured ceramic premium quality jointfree coloured tiles as in vertical surface of walls such as skirting / dado and risers to steps, size of tile shall be 450mm x 300mm x 7 to 8 mm thick, set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigment to match the colour or shade of tiles, laid over and including provison of 10 mm thick rendering as in backing coat of tiles in cement mortar 1:4, complete all as specified and directed.
Taking down cement plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water including removing of all rubbish off from the site, complete all as specified and directed.
Rendering 5mm thick in CM 1:3 on concrete surfaces of ceilings, finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Rendering 15 mm thick, on other than fair faces of brick work or concrete surfaces in cement mortar 1:6, finished surface even and fair, complete all as specified and directed.
Rendering 15mm thick in CM 1:4, mixed with water proofing compound, on fair faces of brick work or concrete surfaces of walls, finishing the surface even and fair, complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
Supply only liquid water proofing compound of approved make, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of ceilings and applying three coats of white wash, complete all as specifed and directed.
Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper of approved colour over a coat of primer over 1mm thick wall care putty finish, complete all as specifed and directed.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint of approved colour over a coat of alkali resistant primer, complete all as specifed and directed.
Preparation of old surfaces of ceiling and applying one coats of white wash, complete all as specifed and directed.
Complete removal of existing treatment from old plastered surface of walls (any number of layers) by scrapping with steel scrappers or any other means, filling depressions of scrapped surfaces with wall care putty and applying two coats of oil bound distemper on walls surface, complete all as specified and directed.
Complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, filling depressions of scrapped surfaces, applying two coats of cement base paint on walls surface, complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5sq.m each with shutters (without taking off shutters from the frames) including removing from site, complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5sq.m but not exceeding 4sq.m each with shutters (without taking off shutters from the frames) including removing from site, complete all as specified and directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick single side prelam PVC sheet, reinforced with M.S. Square tube, complete all as specified and directed. Note: Edges will be painted to match with prelaminated sheet.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, complete all as specified and directed.
Frosted sheet glass, 4mm thick, ordinary quality and glazing with beading not exceeding 0.5 sqm in each pane, with oil putty, complete all as specified and directed.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specifed and direcetd.
Stainless steel handles, fabricated type, 150mm long, complete all as specified and directed.
Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Stainless steel, barrel tower bolts of extruded section and fixed, 150mm long, complete all as specified and directed.
Stainless steel, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet fixed, 250mm long, complete all as specified and directed.
Butt hinges, medium weight, cold rolled mild steel, and fixed, 100mm size, complete all as specified and directed
Demolition of cement concrete (reinforced) in ground floors and pavings not exceeding 15 cm thickness including removing rubbish off the premises, complete all as specified and directed.
Formwork to flat rough finished surface of soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping), complete all as specified and directed.
RCC 1:2:4 type B-1, using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. Note: Reinforcement shall be measured and paid separately.
Granite,(of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like, 20mm thick, over 15mm thick in cement mortar (1:4) screed including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and othe similar situations, complete all as specified and directed.
Vitreous China wash hand basin fixed in counter including fixing such as accessaries size 485x370x205mm, shape rectangular, in repair complete all as specified and directed.
Waste coupling of CP brass, 32 mm dia, sutable for WHB, complete all as specified and directed.
Vitreous China wash hand basin, white flat back, size 550 mm x 400mm excluding taps, waste chain and plug, but including 32mm dia brass waste coupling and 32 mm dia PVC waste pipe (rigid quality) complete all as specified and directed. Note :- Pillar tap shall be measured & paid seperately as supply only under respective item. Fixing of tap deemed to be included in quoted rates.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth, complete all as specified and directed.
Taking up or down 15mm bore, steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down 20mm bore, steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed.
Galvanized steel water tubing, medium grade, with all fittings and fixed to ceilings and walls of or laid in floors, complete 15mm bore, complete all as specified and directed.
Refixing old steel tubing and connection in new or old position (Walls, ceiling, floors, etc.),15mm dia, complete all as specified and directed.
Galvanized steel water tubing medium grade, with all fittings and fixed to ceilings and walls of or laid in floors, complete 20mm bore, complete all as specified and directed.
Refixing old steel tubing and connection in new or old position (Walls, ceiling, floors, etc.), 20mm dia complete all as specified and directed.
PVC (SWR) 75mm dia floor trap, plain with grating including jointing with solvent cement, fixed in repairs, complete all as specified and directed.
Supply only pillar tap cast copper alloy with capstin heads chromimium plated fancy type screwed down high pressure with or without lettered hot or cold with long screwed shank and fly nuts, screwed for iron pipe 15 mm bore, complete all as specified and directed. Note: Taps will be fixed to WHO under item No. 34 here-in-before.
Brass chromium plated fancy type central hole basin mixer with 450mm braided connection pipe (without popup), fixed in repair, complete all as specified and directed.
Soap dish, stainless steel (Gd-304), standard size Soap dish, any type, fixed to wall with plugs & chromium plated brass screws, fixed in repairs complete all as specified and directed.
Tubular towel rail of brass chromium plated, 20mm dia, D type, 60 cm long between flanges, fixed in repair, complete all as specified and directed.
Stainless steel (Gd-304) drapery rod cut to size and fixed in position including brackets, 20 mm dia, (wall thickness not less than 1.25mm) ,fixed to wall, fixed in repair, complete all as specified and directed.
Bib taps cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule 15 mm bore fixed in repair, complete all as specified and directed.
Chromium plated brass shower rose, 65 to 90mm dia, with swivel joints shower arm fixing to steel pipe or union of 15 mm dia pipe, fixed in repair, complete all as specified and directed.
Bib cock, 2 way, cast upper alloy chromium plated with wall flange, 15 mm dia including fixing to pipe , in repair, complete all as specified and directed.
Brass CP wall mixer 15mm bore hot & cold water screwed down for iron pipe and connection to shower, fixed in repair, complete all as specified and directed.
Angle valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, screwed both ends for iron pipe or for unions 15 mm bore, fixed in repair, complete all as specified and directed.
PVC connection 600mm long with PVC check nut, fixed in repair, complete all as specified and directed.
Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position, fixed in repair, complete all as specified and directed.
Vitreous China squatting pan, ‘Orissa’ pattern, water closet, size 580 mm x 440 mm white with integral foot rest any pattern including connection to trap, and too flushing pipe, anti syphonage pipe, fixed in repair, including making good to floor complete all as specified and directed.
Vitreous china wash down water closet (pedestral pattern) pan white, including 10 ltrs PVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, flush pipe of polythylene of low or high density or PVC 32mm dia, Plastic water closet seat, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminium hanging device, fixed in repair, complete all as specified and directed.
PVC waste pipe of 32 mm dia, flexible for wash hand basin, kitchin sink or urinals, fixed in repairs, complete all as specified and directed.
Vitreous China urinal, half stall type white, (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern wtih brackets, flush pipe, grating and union for discharge pipe inclusive of fixing supply pipe to flushing cistern, trap and wast pipe and waste coupling, fixed in repairs, complete all as specified and directed.
Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (Minimum weight 60gms), complete all as specified and directed.
Rotational moulded HDPE water storage tank (cylindrical vertical with closed top), 1000 litres capacity, ISI marked, double layered, hoisted and fixed in position including ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 20 mm bore size (minimum weight 210gms), including dismantling of old tank, complete all as specified and directed.
Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20 mm bore, fixed in repair, complete all as specified and directed.
Excavation in trenches not exceeding 1.5m depth and not exceeding 1.5m wide in soft/loose soil and getting out for foundation, laying pipe, manholes including trimming sides and forming bootom surface to required level, slope etc.complete all as specified and directed.
Excavation in trenches exceeding 1.5m depth and not exceeding 3m depth and not exceeding 1.5m wide in soft/loose soil and getting out for foundation, laying pipe, manholes including trimming sides and forming bootom surface to required level, slope etc.complete all as specified and directed.
Removing of surplus excavated material to a distance n exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point, complete all as specified and directed.
Returning, filling in soils, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Formwork to sides of slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick horizontal or slopping, complete all as specified and directed.
PVC (SWR) 75 mm bore pipes single socketed ends, in any length with rubber ring joints, laid in trenches or in floors including demolition of PCC if needed for removal of pipe, fixed in repair, complete all as specified and directed.
PVC (SWR) 75mm pipes single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc., fixed in repair, complete all as specified and directed.
PVC (SWR) 110 mm bore pipes single socketed ends, in any length with rubber ring joints, laid in trenches or in floors including demolition of PCC if needed for removal of pipe, fixed in repair, complete all as specified and directed.
PVC (SWR) 110mm pipes single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc., fixed in repair, complete all as specified and directed.
PVC (SWR) 75 mm dia, junction single, (single T), equal or unequal with oval access door fixed to PVC pipe joint with rubber solvent, complete all as specified and directed.
PVC (SWR) 110 mm dia, junction single, (single T), equal or unequal with oval access door fixed to PVC pipe joint with rubber solvent, complete all as specified and directed.
PVC (SWR) branch piece, single (single Y) equal or unequal, 75mm bore, complete all as specified & directed.
PVC (SWR) branch piece, single (single Y) equal or unequal, 110mm bore, complete all as specified & directed.
PVC (SWR) vent cowl, 110mm bore, complete all as specified and directed.
Mild steel stack clamps iron stays made out of 50 mm x 5 mm flat iron, including bolts and nuts and securing ends of stays to wall or roof suitable for fixing of 110 mm bore pipe, complete all as specified and directed.
Mild steel stack clamps iron stays made out of 50 mm x 5 mm flat iron, including bolts and nuts and securing ends of stays to wall or roof suitable for fixing of 75 mm bore pipe, complete all as specified and directed.
PVC (SWR) bends / shoe of any radius and 75mm bore, complete all as specified and directed.
PVC (SWR) bends / shoe of any radius and 110mm bore, complete all as specified and directed.
Demolition of Plain cement concrete (PCC) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Treatment to sunken floor and sides as mentioned here-n-after:- (Step-I) removing existing roof treatment and cleaning of RCC surface of sides and base slab by sand blasting using compressed air. (Step-II) Applying a coat to sides and base of sunken with glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal -107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika Fab-I and top coat with Sika Seal-107@ 1.50 Kg/Sqm or equivalent of Forsoc or pidilite. (Step-III) M&L 15 mm thick cement plaster on side and base slab of sunken part in cement mortar 1:3 mixed with appropriate integral water proofing compound with Sika Plastocree plus as specified. (Step-IV)M&L applying evenly a tack coat of industrial bitumen 85/25 @ 1.20 Kg/Sqm on plastered surface of sunken sides & base.Note:All debris obtained from site will be thrown away out side Def Land by contractor at his own expense.
Plain cement concrete 1:5:10, type B-2( using 40 mm graded crushed stone aggregate) as in filling in sunken part of slab, finished even & rough, complete all as specified and directed.
Cement concrete 1:2:4 type B-0 (12.50mm graded stone aggregate), 25mm thick, as in levelling course, complete all as specified and directed.
Celuka ply, 18mm thick, single side prelam/ Rigidlam colour fixed with screws, solvent cement/ adhesive to make kitchen cabinet sides, top and bottom and shelves inside the cabinets, complete all as specified and directed. Make: Rajshri plastiwood/ SYNTEX or any other commercially equivalent in make as approved by GE.
Auto closing hinges 35mm of 0 crank (KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters complete all as specified and directed
Demolition of cement concrete (reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) including chequered tiling and paver blocks, complete all as specified and directed.
Plain cement concrete, 75 mm thick, 1:4:8, type-D-2, (using 40mm graded stone aggregate) as in sub base for floor finishes complete all as specified and directed
Machine pressed precast conctete interlocking paver block with grey cement & no pigment, any shape and size, confirming to IS 15658-2006, 80 mm thick, M-40 Grade, laying over 25mm thick sand cushning complete all as specified and directed.
Plain cement concrete 1:2:4, type B-1 (Using 20 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges coping etc incl necessary formwork complete all as specified and directed.
Surface excavation in soft/loose soil not exceeding 30cm deep and averaging 15 cm and getting out including leveling the surface, complete all as specified and directed.
Hardcore, of broken stone or boulders, of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of white wash, complete all as specifed and directed.
PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation filling or mass concrete or similar wrok complete all as specified & directed.
Precast cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in drain cover, cover slab (for manholes) and similar work with plain faces, set in CM 1:4, complete all as specified & directed.
Boring 300mm dia size duct bore (rechare well) through any kind of soil/ strata upto required depth and getting out soil including removel of surplus soil, complete all as specified and directed.
UPVC slotted pipe 150mm bore confirming to IS codes with vertical 3mm slot including all fitings, complete all as specified and directed.
Low density polyethylene 25 mm bore pipes (LDPE) of pressure rating 6 kgf/cm2 and fittings, fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
UPVC ball plug suitable for 150mm dia UPVC pipe complete all as specified and directed.
UPVC well cap suitable for 150mm dia UPVC pipe complete all as specified and directed.
Loose filling with pea gravels spread and levelled complete all as specified and directed.
Loose filling with boulders of size 100mm to 200mm spread and leveled, complete all as specified and directed.
Loose filling with boulders of size 50mm to 100mm spread and leveled, complete all as specified and directed.
Sand cushioning with dry local sand and leveling complete all as specified and directed.
Plain cement concrete 1:3:6 type C2 (40mm graded stone aggregate), as in surface channel, complete all as specified and directed.
Bricks, sub class B, laid flat, in floors, old size bricks bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:3, complete all as specified and directed.
Bricks, sub class B, laid on edge in floors, old size bricks bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:3, complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed. Note: Only inner girth shall be measured.
TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Supply of sweet earth and rough excavation not exceeding 1.5 m deep and getting out removing excavated material exceeding 1.50 km but not exceeding 5 km and depositing where directed Spreading and levelling in layers n exc. 25 cm thick complete all as specified and directed.
Maintenance and supervision of carpet grass etc including spreding of pesticides, insecticides in the desired periodicity deweeding , watering and replacing dead plant/ grass with new etc and periodical maintenance from the certified date of completion of work, complete all as specified and directed. Note :- (i) The Contractor shall ensure that the contractor is having tractor, tanker , small tanks on rikshaw fitted with hose pipe etc for watering purpose and requiset equpment for spreying of medicine on plants/Grass , ploughing the earth for deweeding out unwanted growth/grass etc in running condition throughout the period. (ii) The foliage and other unwanted item shall be removed from the site to be place as directed by GE.
Excavation in post hole size 60cmx60cmx60cm or according to the plant size and plant the plant Bougainvillea straight inside the pit and fill up the pit with the earth along with inorganic fertilizer like urea @ 10gm/plant di-ammunium phosphate @ 15gm /plant, bonemail @ 1kg /plant and pesticide treatment with Azadirachtin @ 1 kg/plant, chloripyriphos @ 3ml/plant including removing and spreading the surplus excacated soil, complete all as specified & directed. NOTE: The height of the sapling should not be less than 2.50 mtr, caliper not less than 50mm, multi-branched(+1m to +1.5m), complete all as specified & directed by Engr-in-Charge.
Excavation in post hole size 60cmx60cmx60cm or according to the plant size and plant the tree Bottle Palm straight inside the pit and fill up the pit with the earth along with inorganic fertilizer like urea @ 10gm/plant di-ammunium phosphate @ 15gm /plant, bonemail @ 1kg /plant and pesticide treatment with Azadirachtin @ 1 kg/plant, chloripyriphos @ 3ml/plant including removing and spreading the surplus excacated soil, complete all as specified & directed. NOTE: The height of the sapling should not be less than 2.50 mtr, caliper not less than 50mm, multi-branched(+1m to +1.5m), complete all as specified & directed by Engr-in-Charge.
Supply installation and testing of Hi wall split type air conditioner units (indoor & outdoor) complete with cordless remote control unit and with in-built cooling arrangement, air ioniser and plasma filler for better indoor air quality, with digital inverter rotary type compressor, single phase units 220V- 240V, 50Hz, with 5 star rating and EER 3.2 of 1.5 TR capacity, complete all as speciifed and directed. Note: (i) Copper pipe of dia ½'' and ¼'' with insulation and drain pipe up to 10 RM as per rquirement will be concealed/casing caping as specified and directed by Enger-in-charge shall be deemed to be included in unit quoted rate. (ii) Wall dirll as per requirement to install AC indoor/outdoor unit and making good to walls disturbed surface & applying finished to match existing surface complete all as specified and directed shall be deemed to be included in unit quoted rate.
Voltage stabilizer for automatic operation, SP naturally are cooled in-door type designed for input variation 170 V to 250 V output stabilized at 230 V with accuracy of +/- 2.5% and capacity 5 kVA, complete all as specified and directed.
PVC AC modular surface box with combination 2 in1, 5 pin, 5/15 Amps with and including heavy duty socket and 1 X MCB SP 16 Amp, complete all as specified and directed.
Taking down carefully point wiring of any type and any description / caping or concealed [light point, fan point or socket point] including removal of battens, pipes, plug sockets, switches, shades, ceiling roses, light fittings etc complete and making good disturbed surface to match the exisitng, complete all as specified and directed.
Taking down switches, distribution boards and old cut-outs etc., of any type and carefully along with the existing boards and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
Taking down carefully sub-main wiring of any type and any numbers including earthwire surface type / concealed type and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
Point wiring complete with PVC insulated unsheatehd, 1100 volts grade cable 1.5 sq.mm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories, including provision of concealed pressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside and outside with two coats of black bituminous paint over and including a coat of red oxide primer, with 2.8 mm thick top cover of plastic lmainated sheet of required colour for mounting switch, sockets, fan regulator etc, including 1.5 sq.mm FRLS type PVC insulated unsheathed cable multi stranded copper conductor as continuous earth wire and connected to earth dolly as required at site and including chases cutting and making good the disturbed surface and applying finishes to match the existing surface, complete all as specified and directed for the following:-
One light / fan /bell/ exhaust fan point, controlled by one one-way 5Amp switch
One 5 pin, 5 Amp socket outlet point on an independent board.
One 5 pin, 5 Amp socket outlet on the same board with other switches
One 6 pin, 15 Amp socket outlet point on an independent board with cables of size 2.50Sqmm.
Switch piano, flush type, single pole, one way 5/6 Amp 230 volts, white or ivory, complete all as specified and directed.
Socket outlet, 2 in 1, 5 pin, 5/6 Amps 230 Volts, flush type, complete all as specified and directed.
Switch piano, flush type, single pole, one way 15/16 Amp 230 volts, white or ivory, complete all as specified and directed.
Socket outlet, 2 in 1, 6 pin, 15/16 Amps 230 Volts, flush type, complete all as specified and directed.
Lamp holder, PVC polycarbonate body with back plate suitable for batten fittings, complete all as specified and directed.
Ceiling rose, single phase, PVC / polycarbonate, insulated body, three terminals, surface bakelite sheet 63.5mm dia, complete all as specified and directed.
Sheet metal enclosure for MCB DBs SPN, 8 way, double door, vertical type, 240 V with 200 Amps rated bus bar, complete with incoming/ outgoing connection through proper size of lugs and cable glands, complete all as specified and directed
MCB SPN 6-32 Amp, 240 volts 10 KA, 'C series' complete all as specified and directed.
MCB SP 6-32 amps 230 Volts, 10 KA 'B series' complete all as specified and directed.
LED wall mounted tube light fittings 1x18 watt four feet long decorative box type [Ultra slim] linear LED [6000K] with co-extruded polycorbonate body, envoirement friendly, energy efficient prewired and making conection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2mtr, fixed on wall firmly, fixed in repair, complete all as specified and directed.
Road lighting luminaire, 25 Watt, with unique peanut optics to ensure uniform distribution, higher spacing between poles and maintenance free system for city roads and Streets, 50% Energy Savings, IP66 Protection PC and FG Cover, High Impact Resistance complete including LED Lamps and all accessories including bracket made out of 25mm bore GI pipe (light grade), 1.20 m long made to shape and fixed to existing pole or building by means of 2 Nos mild steel flat iron 40x6mm clamps with suitable size bolt, nuts & washers and connecting with three core flexible copper wire of size 23/0.0076 from ceiling rose to existing junction box, complete all as specified and directed.
Ventilator fans AC single phase 230/240V of size 380 sweep "metallic range" complete including making holes and necessary make good disturbed surfaces complete all as specified and directed.
Sub main wiring complete with 2 runs of 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of PVC rigid conduit 20mm dia and accessories connecting terminal ends to DB's including providing 1 run of 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly including taking down existing sub main wiring any type and making good disturbed surfaces to match with existing including sinking of boxes , complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of PVC rigid conduit and with accessories shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of PVC rigid conduit 20mm dia and accessories connecting terminal ends to DB's including providing 1 run of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly including taking down existing sub main wiring any type and making good disturbed surfaces to match with existing including sinking of boxes , complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC rigid conduit and with accessories shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sheet metal enclosure for MCB TPN double door type, single pole and neutral 4 way 415Volts with 200 Amps rated copper bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way, fixed in repair, complete all as specified and directed.
MCB TPN 40 to 100 Amps, 415Volts, 10kA breaking capacity, convenient to 'C' Curve complete all as specified and directed.
M/S Akhilesh Enterprises
HARI OM CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .