Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹9.1 Cr 1 FLOOR SHRADDHA COMPLEX GE ROAD RAIPUR CHHATTISGARH PIN 492001 91 98261 46919 | ₹9.1 Cr |
Tender Value
₹10.2 Cr
EMD Value
₹10.2 L
Closing Date
25 Sept 2024, 11:00 amClosed
Setting up of Solar Water Heating system at Jawahar Navodaya Vidyalayas under Lucknow Region
NBCC/RE/NVS-Solar/Lucknow-Region/2024/20
NBCC/RE/NVS-Solar/Lucknow-Region/2024/20
Open Tender-Domestic
Miscellaneous Goods
Lucknow, Uttar Pradesh
₹11,800
₹10.2 L
11 Aug 2026
23 Aug 2024
25 Sept 2024
25 Sept 2024
7 Nov 2024
A Estimated Cost
1 Solar Water Heating System 500LPD Each 102261213.66
2 Solar Electric Heater/ Geyser 500LPD Each 0.00
TOTAL ESTIMATED COST (RUPEES) 102261213.66
(Inclusive of GST @ 18%) 10.226
Digitally signed by SANGRAM
NVS (LUCKNOW REGION)
SOLAR WATER HEATING AND ELECTRIC WATER HEATER/GEYSER UNITS
Description Unit Qty. Rate Amount (Rs.)
1.0 NS SOLAR WATER HEATING SYSTEM OF CAPACITY: 500 LPD EACH
Supply, Installation, Testing & Commissioning of 500 LPD Flat Plate based thermosyphone circulation Non-Pressurized Solar water heating
Systems comprising Flat Plate collectors , internal system piping, insulated hot water storage tank , Heat Exchanger, Electric Back up Heaters,
plumbing accessories, electrical items as required. Including DLP of complete system for 2 years and Guarantee/warranttee of Solar water Set 722 141636.03 102261213.66
heating unit for 5 years. Details of each items to be used in one 500 LPD system are mentioned below:
ITEMS FOR 1 SET
SITC of 500LPD Solar FPC Collector & Storage Tank with Stand - 4 nos. of Solar Flat Plate Collectors of minimum 2030x1030mm size for
minimum 2.0 Sq.Mtr. Absorber material shall be ETP grade Copper with copper Fins & Copper Tubes. The Flat Plate Collectors shall be as per IS
12933. Along with 500LPD Solar Water Heating Tank made out of MS steel of 2.0 mm thickness and Manufacturer Standard Dish Thickness
with internal epoxy/PU coating OR SS 2mm thick and outer precoated Aluminium Cladding over 50mm PUF Insulation having density not less
than 32Kg/Cu.mtr. With In-Built Ladder type Heat Exchanger made of SS-304 & 5 Ltr SS (1mm thick) Expansion tank, maintenance free
sacrificial/Magnesium Anode, provided with Electrical Heater 2Nos. x 3KW electrodes with thermostat/ Auto Cut , Cold Water inlet, Hot Water
outlet, Collector - Inlet and Outlet piping with insulation. Collector & Tank Stands made out of MS angle iron size shall not be not less than
35mmx35mmx3mm, CC Foundation as per the direction of Engineer incharge. (BIS 12933).
PLUMBING ITEMS PER SET
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
20 mm nominal dia Pipes (Min.: 15Mtrs OR as per actual site requirement)
Nitrile foam insulation of 9 mm thick with 26 gauge aluminium cladding for 20mm dia Hot water Pipe (Min.: 8Mtrs OR as per actual Site
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20 mm nominal bore (Min.: 2nos. OR as per actual site requirements)
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
25 mm nominal bore -Horizental (Min.: 2nos. OR as per actual site requirements)
Y Strainer -Screwed- 20mm dia -Bronze (Min.: 1nos.OR as per actual site requirements)
Air Release Valave- 20mm (Min.: 1nos.OR as per actual site requirements)
Auto Air Vent -20mm (Min.: 1nos.OR as per actual site requirements)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
15 mm nominal bore (Min.: 1nos.OR as per actual site requirements)
Dial Type Temprature Gauge 100mm dia (0-150deg) (Min.: 1nos.OR as per actual site requirements)
Control Panel / ACDB for Electrical Heater including required switchgear like DP MCB incommer & DP MCB outgoing of suitable ratings for
each 3KW Heater. Housed in Poly Carbonate (IP65) Enclosure, Complete with wiring up to heater in PVC Conduit.
Digitally signed by SANGRAM
Electrical Wiring for incoming to ACDB :
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in
surface/ recessed medium class PVC conduit as required.
2 X 6 sq. mm + 1 X 6 sq. mm earth wire (Min.: 15mtrs OR as per actual site requirements)
2.0 NS ELECTRIC WATER HEATING SYSTEM OF CAPACITY : 500 LPD EACH
Supply, Installation, Testing & Commissioning of 500 LPD Electric Water Heating System/ Geyser comprising Electric Heaters , internal system
piping, insulated hot water storage tank, plumbing accessories, electrical items as required. Including DLP of complete system for 2 years and Set 0 97247.83 0.00
Guarantee/warranttee of Electric water heating/Geyser unit for 5 years. Details of each items to be used in one 500 LPD system are
mentioned below:
ITEMS FOR 1 SET
SITC of 500LPD Electric Heating System/ Geyser having Hot Water Storage Tank made out of MS steel of 2.0 mm thickness and
Manufacturer Standard Dish Thickness with internal epoxy/PU coating OR SS 2 mm thick and outer precoated Aluminium Cladding over 50mm
PUF Insulation having density not less than 32Kg/Cu.mtr. Maintenance free sacrificial/Magnesium Anode, provided with Electrical Heater 2Nos.
x 3KW electrodes with thermostat/ Auto Cut , Cold Water inlet, Hot Water outlet. Storage Tank Stand made out of MS angle iron size shall not be
not less than 35mmx35mmx3mm, CC Foundation as per the direction of Engineer incharge.
PLUMBING ITEMS PER SET
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
20 mm nominal dia Pipes (Min.: 15Mtrs OR as per actual site requirement)
Nitrile foam insulation of 9 mm thick with 26 gauge aluminium cladding for 20mm dia Hot water Pipe (Min.: 8Mtrs OR as per actual Site
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20 mm nominal bore (Min.: 2nos. OR as per actual site requirements)
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
25 mm nominal bore -Horizental (Min.: 2nos. OR as per actual site requirements)
Y Strainer -Screwed- 20mm dia -Bronze (Min.: 1nos.OR as per actual site requirements)
Air Release Valave- 20mm (Min.: 1nos.OR as per actual site requirements)
Auto Air Vent -20mm (Min.: 1nos.OR as per actual site requirements)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
15 mm nominal bore (Min.: 1nos.OR as per actual site requirements)
Dial Type Temprature Gauge 100mm dia (0-150deg) (Min.: 1nos.OR as per actual site requirements)
Control Panel / ACDB for Electrical Heater including required switchgear like DP MCB incommer & DP MCB outgoing of suitable ratings for
each 3KW Heater. Housed in Poly Carbonate (IP65) Enclosure, Complete with wiring up to heater in PVC Conduit.
Electrical Wiring for incoming to ACDB :
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in
surface/ recessed medium class PVC conduit as required.
2 X 6 sq. mm + 1 X 6 sq. mm earth wire (Min.: 15mtrs OR as per actual site requirements)
Digitally signed by SANGRAM
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT LKO Solar.pdf
Tender Document
GCC with Amendments.pdf
Tender Document
BOQ.pdf
Tender Document
LR SCC.pdf
Tender Document
Tender Drawings.pdf
Tender Document
LR Scope of Work.pdf
Tender Document
LR Tech_Specs.pdf
Tender Document
Intergrity Pact SIgned.pdf
Tender Document
Instructions_for_online_bid_submission.pdf
Tender Document
LR-LOM.pdf
Tender Document
corrigendum-2925-Corrigendum220.pdf
pdf • 0.04 MB
addendum-13ef98f20d77-Corrigendum220.pdf
pdf • 0.04 MB
corrigendum-2889-Corrigendum120Final.pdf
pdf • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .