| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹39.1 L+₹2.2 L (5.92%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹39.1 L+₹2.2 L (5.98%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 |
| Sl No | Description | Qty | Unit | SHRI SULAI ELECTRICALS L3 | metro electrical services L2 | DIAMOND ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down existing copper/aluminum existing point wiring (light/fan/socket or power points) complete (fittings such as switches,ceiling roses,pendents, regulators, sockets etc to be measured saperatly) incl wooden battens and conduct etc & removing material as directed complete all as specified and as directed by Engr-in-Charge.
Note applicable for BOQ item no 1 to 138 (a) contractor rep/ superviser shall be present at office of Engineer-In-Charge at 9AM every day for taking of instruction regarding repairs to be carried out on the day on priority,(b) alternative Electricians deploy in place of regular electrician has to work on sunday/holiday to attend faults/defects/complains.In case if electrician fails to rectify the faults then recovery shall be recovered from contractor s any due payment(c)The repair work on any single day may be order by Engineer-In Charge to be carry out in number of places/building in one day i.e in one buildings quantity of any of BOQ items to be carried may be one or more & number of BOQ items to be executed on any single day may also be one or more(d) Contractor shall not have any claim on account of order of one or more quantity of one or more items of BOQ that to be executed in one or more building and or area in any single day & even the same on any numbers of day during contract period(f) all above mentioned labour effect on this account is deemed to be included in quoted rates by the tenderer for all items of this tender.Note:1) Complaints/Defects will be rectified withen 8 Hrs of intimated time. if complaints not rectified, a recovery of an amount of Rs150/-/ complains/ day will be recoverd from the RAR/ FB , ii) Rates are inclusive of T&P required safety equipment, and transport required contractor shall arrange on his own arrangement, iii).Compliant given by any electronic media i.e SMS, email or whats app etc and in writting shall be count as valid compliant contractor to take immediate action within stipulated time as mention in note -1 above. | 300 | Per Point | 35 ₹10,500 | 22 ₹6,600 Lowest | 22 ₹6,600 Lowest |
| 2.00 | M&L for Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including surface in wall/celling/floor in PVC casing caping as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including PVC boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr-in-Charge. | 50 | Point | 500 ₹25,000 Lowest | 575 ₹28,750 | 540 ₹27,000 |
| 3.00 | All as per item no 2 but for One 5 Amps socket point on same/below board with other switches. | 20 | Point | 250 ₹5,000 Lowest | 300 ₹6,000 | 300 ₹6,000 |
| 4.00 | All as per item no 2 but for One 5amps switch socket point independent. | 80 | Point | 500 ₹40,000 Lowest | 575 ₹46,000 | 540 ₹43,200 |
| 5.00 | M&L for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run including surface in wall/celling/floor in PVC casing caping as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates. | 40 | Per Point | 850 ₹34,000 Lowest | 900 ₹36,000 | 875 ₹35,000 |
| 6.00 | Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. | 100 | Per Point | 650 ₹65,000 | 700 ₹70,000 | 616 ₹61,600 Lowest |
| 7.00 | All as per item no 6 but for One 5 Amps socket point on same/below board with other switches. | 15 | Point | 300 ₹4,500 Lowest | 340 ₹5,100 | 350 ₹5,250 |
| 8.00 | All as per item no6 but for One 5amps switch socket point independent. | 15 | Point | 650 ₹9,750 | 700 ₹10,500 | 630 ₹9,450 Lowest |
| 9.00 | M&L for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in wall/floor PVC medium grade conduit not less than 20 mm as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. (Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.) | 20 | Per Point | 1,000 ₹20,000 Lowest | 1,170 ₹23,400 | 1,150 ₹23,000 |
| 10.00 | Repair of Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in PVC conduit in concealed or cassing capping as reqd at site with all fittings such as bends, tee, junction boxes,etc with suitable size of 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly for one light/fan/call bell point complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates. | 50 | Per Point | 150 ₹7,500 | 100 ₹5,000 | 70 ₹3,500 Lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
12 Jul 2025, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIR AND MAINT OF UNSV OLD WIRING, FIXTURE INTERNAL ELECTRIFICATION AND REPAIR OF LIGHTS UNSV FANS, EXHAUST FANS, AIR CIRCULATOR GEYSERS, UNSV HIGHBAY HANGER LIGHTS, FLAME PROOF WIRING AND FITTING AND OTHER CONNECTED ITEM IN TECH AREA AND AFLE (HAL
2025_MES_713423_2
8332/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹70,000
13 Oct 2025
25 Jun 2025
14 Jul 2025
26 Jun 2025
12 Jul 2025
28 Jun 2025
Amount
Taking down existing copper/aluminum existing point wiring (light/fan/socket or power points) complete (fittings such as switches,ceiling roses,pendents, regulators, sockets etc to be measured saperatly) incl wooden battens and conduct etc & removing material as directed complete all as specified and as directed by Engr-in-Charge. Note applicable for BOQ item no 1 to 138 (a) contractor rep/ superviser shall be present at office of Engineer-In-Charge at 9AM every day for taking of instruction regarding repairs to be carried out on the day on priority,(b) alternative Electricians deploy in place of regular electrician has to work on sunday/holiday to attend faults/defects/complains.In case if electrician fails to rectify the faults then recovery shall be recovered from contractor s any due payment(c)The repair work on any single day may be order by Engineer-In Charge to be carry out in number of places/building in one day i.e in one buildings quantity of any of BOQ items to be carried may be one or more & number of BOQ items to be executed on any single day may also be one or more(d) Contractor shall not have any claim on account of order of one or more quantity of one or more items of BOQ that to be executed in one or more building and or area in any single day & even the same on any numbers of day during contract period(f) all above mentioned labour effect on this account is deemed to be included in quoted rates by the tenderer for all items of this tender.Note:1) Complaints/Defects will be rectified withen 8 Hrs of intimated time. if complaints not rectified, a recovery of an amount of Rs150/-/ complains/ day will be recoverd from the RAR/ FB , ii) Rates are inclusive of T&P required safety equipment, and transport required contractor shall arrange on his own arrangement, iii).Compliant given by any electronic media i.e SMS, email or whats app etc and in writting shall be count as valid compliant contractor to take immediate action within stipulated time as mention in note -1 above.
M&L for Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including surface in wall/celling/floor in PVC casing caping as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including PVC boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr-in-Charge.
All as per item no 2 but for One 5 Amps socket point on same/below board with other switches.
All as per item no 2 but for One 5amps switch socket point independent.
M&L for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run including surface in wall/celling/floor in PVC casing caping as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge.
All as per item no 6 but for One 5 Amps socket point on same/below board with other switches.
All as per item no6 but for One 5amps switch socket point independent.
M&L for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in wall/floor PVC medium grade conduit not less than 20 mm as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. (Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.)
Repair of Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in PVC conduit in concealed or cassing capping as reqd at site with all fittings such as bends, tee, junction boxes,etc with suitable size of 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly for one light/fan/call bell point complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
Supplying and fixing in repairs Modular white cover plate with frame, 3 Module, Make Legrand /Anchor Roma/Crabetree.
Supplying and fixing in repairs Modular white cover plate with frame, 6 Module, Make Legrand /Anchor Roma/Crabetree.
Supply & fix metal fiush mounting box 3 module.
Supply & fix metal fiush mounting box 6 module.
Servicing of Inverter single phase AC input 160 to 260 V and out put 230 + 1 % of capacity 5 KVA including making electric connection cost of replacement of any related part for smooth functioning of the inverter is deemed to be included under quoted rate,Complete all as specified & as directed by Engineer-In-Charge.
Servicing the low specific gravity batteries by way of replacement of electolyte/charging and testing ,Complete all as specified & as directed by Engineer-In-Charge.
Supply & fix rigid non metelic PVC conduit not less then 20mm/Casing caping exclusive of boxes (junction/terminal) but inclusive of all tee,bends, elbow, reducer bell mount tube ends and fixing accessories such as coupler, lock nuts saddles, pipe hooks etc complete all as specified & directed.
M&L wiring for circuit/ sub main wiring Flame proof of 2x1.5 Sqmm + 1x1.5 Sqmm earth wire, alongwith earth wire PVC (FRLS-H) insulated copper conductor, single core, 1100 v grade cable in surface/concealed as required in Steel conduit with all fiting tee band complete all as directed by Engr -in- Charge.
M&L for Flame proof Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS-H) insulated sheathed copper stranded conductor cable run in wall/floor steel conduit medium grade conduit not less than 20 mm as per IS with all flame proof fittings such as bends, tee, junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS-H) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes for one light/fan point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. (Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.)
M&L wiring for circuit/ sub main wiring of 2x1.5 Sqmm + 1x1.5 Sqmm earth wire, alongwith earth wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in including PVC casing caping/ PVC conduit complete all as directed by Engr -in- Charge.
M&L wiring for circuit/ sub main wiring of 2x2.5 Sqmm + 1x2.5 Sqmm earth wire, alongwith earth wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in including PVC casing caping / PVC conduit complete all as directed by Engr -in- Charge.
M&L wiring for circuit/ sub main wiring of 2x4 Sqmm + 1x4 Sqmm earth wire, alongwith eart wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable including in PVC casing caping/ PVC conduit complete all as directed by Engr -in- Charge.
M&L wiring for circuit/ sub main wiring of 2x6 Sqmm + 1x6 Sqmm earth wire, alongwith eart wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable including surface in wall/celling/floor in PVC conduit/ casing caping complete all as directed by Engr -in- Charge.
Supply and fixingTempra plug & socket DB TPN with a five pin and earth plug ( 3P+N+E) & socket complete with one no MCB 32 Amp TPN, 415 V Make- Havells cat No DHDPBTN032 or Legrand Cat. Nos 507862 or equivalent make of L&T complete all as specified & as directed by Engineer-In-Charge
Supply and fixingTempra plug & socket DB SPN with a three pin and earth plug ( (2P+E) & socket complete with one no MCB 32 Amp SPN, 240 V Make- Havells cat No DHDPBDP032 or Legrand Cat. Nos 507863 or equivalent Make of L&T,complete all as specified & as directed by Engineer-In-Charge
Supply and fixing Industrial plug with a five pin ( 3P+N+E) 32 Amp complete Make- Havells cat No DHQBB65016 or Legrand / L&T complete all as specified & as directed by Engineer-In-Charge
Supply and fixing Industrial plug with a 3 pin ( 2P+N) 32 Amp complete Make- Havells cat No DHQBB65016 or Legrand / L&T complete all as specified & as directed by Engineer-In-Charge
Supply and fixing wall mounted Industrial socket five pin ( ( 3P+N+E) complete , 415 Make- Havells cat No DHQDB65032 or Legrand/L&T,complete all as specified & as directed by Engineer-In-Charge
Supply and fixing wall mounted Industrial socket five pin ( ( 2P+N) complete ,240 vMake- Havells cat No DHQDB65032 or Legrand/L&T,complete all as specified & as directed by Engineer-In-Charge
Supply and fixing decontactor plug and socket of capacity 125 A, 5 pin , (3 P- N-E ) . Cat part No DS9A7A1 and DS9B7A1 or Equivalent in Legrand/L&T,complete all as specified & as directed by Engineer-In-Charge
S&F 300 mm 3 Blade Wall Fan operated on 230/240V AC,100 W Single phase electric supply ,5 star with motor speed of 2200 RPM complete including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from wall point to fan connector including writing MES No. on ceiling fan white synthetic enamelled paint complete all as per specified and directed by Engr-in- Charge . Make Havelles cat pt- ACCELERO or equivalent in Orient n & crompton
Supply and fixing in replacement ofIR lamp (infra red heating lamp) 250 watt for Heat pillar, incandescent type BR125 shape hard glass with E 27 base product code /cat part No BR125 IR 250 W-E27 230-250V CL ICT/10 threaded type of Make-Phillips including 03 nos as required at site.
supply, installation, testing, and commissioning of a 3-phase autotransformer system intended for voltage variation and control 30 infrared (IR) heating lamps. The transformer shall support up to Current : 20Amps, Phase : Three. Type : Closed type. Input : 415V AC 50/60Hz. Output : 0-470V. (NO continues LOAD above 5mins). Output: Digital VOLT-AMPS METER. INPUT INDICATOR :3NOS. STEEL LIFTING HANDLES. 4 Castor wheels for movement of Variac.Cat Part: 20P-3VAM. The The transformer shall comply with all relevant standards for safety, quality, and performance.
S&F in replacement of microprocessor based three phase, AC Three Phase Trivector Meter DLMS Compliance of Accuracy Class 1,0, 3X 240V, 50Hz, with Backlit LCD Display of rating 10-60A, (Measures KWH, KVAH, KVAm lag & lead, V, I, kW, PF, Hz, Last 6 months history of energies & MD with special features like TOD, Tamper logging, Optical & RS232 Communication Port & Display in absence of Power with Box. Car part No TPPB15211310020002 of HPL or equivalent in L&T/Secure
S&F in replacement of microprocessor based single phase, AC electronic tamper proof static energy meter LCD display Electronic KWH meter of capacity 5-30 Amp, 240 Volts, 50 HZ, accuracy class 1 , KWh compact meter with pilfer proof meter bo with sealing screw provision base mounting, projection mounted Cat no- SPPB1310000002OC00 of Make:- HPL / L&T / Make : Secure
Supplying and fix in repair sheet metal enclousers with socket, plug top and MCBs, single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB , single pole, 240 V of capacity 20 amps , complete all as specified and as directed by Engr-in-Charge.
Supply and fixing PVC flexible copper cable multistranded 5 core 2.5 sqmm fixed with wall with suitable size of clamp complete all as specified and as directed by engr-in-charge.
Supply and fixing PVC flexible copper cable multistranded 3 core 2.5 sqmm fixed with wall with suitable size of clamp cpmplete all as specified and as directed by engr-in-charge.
Supply and fixing in replacement only CRYSTA LED Glass T8 tube rod with in built driver Double sided connection. 1x20 Watt (Double sided connection) (4 ft) . Make - Crompton Cat No LGT8- 20-865-2 or Havells/Bajaj.
Taking down old unserviceable street light fittings /high way light /flood light/Watch tower light ) of any type and capacity up to 15 mtr heights and deposited to MES store yard for further disposal.
Supply, Installation, Testing and commissioning of LED Highbay 100 Watt with a nominal system output of 12000 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50000 burning hours at L70. the lminaire should have a colour temprature of 5700K The luminaire housing should mad eof High Pressure die cast Aluminium with loop in loop out, lense on each LED. LED used should be high power LED placed on ceramic base chip. Driver should be potted.The total power consumption should not exceed 120W (Including driver) Make Crompton Cat.Part.No.CIP-327-100-57-60D-HL2-LM-NSG" or equivalent model of HAVELLS and Philips
Supply, Installation, Testing and commissioning of 120 w Circular LED High Bay fixture Housing made of Pressure Die-cast aluminium housing (heat sink) for efficient thermal management, sturdiness & excellent corrosion resistant for effective thermal management with in built cover of LED Circular PC lens . High Bay system wattge consist of max 120 w , 140V -260V AC, with System Lumen Output min 14000 lumen .Optics with High quality polycarbonate lens with optional 60 and 90 ° beam angle . Powered by an Isolated integral IP 66 Potted electronic driver with 10 KV Surge Protection (SMPS based constant current supply) with lower THD, Output Short Circuit, Over Voltage, Surge Protection. CCT 5700 - 6500 K , CRI >70, THD < 10%, PF >.95, IP65, IK07 .Life class of 50,000 hrs @ L70, Operating Temperature :-10 TO + 45 DEG.C TEST REPORT TO BE SUBMITTED; Test Report LM 79 FOR Complete LED Luminaries and LM 80 for LED Chip as well as PHOTO BIOLOGICAL SAFETY for LD chip. LED fixture with BIS R mark and R Registration no. must for each Fixture. As per Crompton Cat Ref: CIP-328-120-57-60D-HL2-NS-LM-NSG (120 lm/w 10KV SPD ) with 5 Year written warranty from manufacturer or equivalent in Havells/Phillips
Supply and fix 36W LED Ultra-modern recess mounting luminaire with high performance LEDs, maximum 36 W 2x2 LED Panel suitable for mounting in Armstrong / 2x2 Grid ceiling which provides soft-light and glare free symmetrical illumination with CRCA powder coated Housing with sheet thickness of min 0.4 mm and with min 50 mm fixture Depth / height with glare free high translucent milky high grade diffuser with min 0.8 mm thickness . High efficiency long life LED package in integral module with lumen efficacy of >140 lm/W and viewing angle of 120° to ensure better uniformity with minimum System Lumen of 4300 Lumens with CRI > 80, Color temperature 5500- 6500 K, THD < 10% and PF > 0.95,IP20 , IK03.Life class of 50,000 hrs. @ L70, Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection: 4 KV; Protection : Reverse Polarity, Open & Short Circuit. DRIVER SAFETY REQUIREMENT STANDARDS :IS 15885-2-13, TEST REPORT TO BE SUBMITTED; PHOTO BIOLOGICAL SAFETY NORMS: IS 16108, TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE LM 80 FOR LED SOURCE. Fixture with R mark and registration number. As per Crompton Cat Ref: LCTLRNE-40-CDL(1X4) with 5 Year warranty from manufacturer or equivalent in Havells/Philips Note for items Nos 2 to 10: (I) To write CA nos with date of installation on each fitting (any type) with permanent marker pen . (ii) Contractor is fully responsible for replacement of unsv fitting from OEM/Dealer. (iii) All reports and test certificate of light fitting submitted by contractor before payment. (iv) The rate of T&P reqd at site for replacement of LED fitting up to 15mtr height are deemed to be included in the quoted rates.
Supply and fix Ultra-modern recess mounting luminaire with high performance LEDs, maximum 40 W Size 1 x 4 Ft LED Panel suitable for mounting in Armstrong / 1x4 Grid ceiling which provides soft-light and glare free symmetrical illumination with CRCA powder coated Hsg with sheet thickness of min 0.4 mm and with min 50 mm fixture Depth / height with glare free high translucent milky high grade diffuser with min 0.8 mm thickness (making addition alteration with existing falsce ceiling using suitable aluminium grid /supporting structure is deemed to be included in the quoted rates) . High efficiency long life LED package in integral module with lumen efficacy of >140 lm/W and viewing angle of 120° to ensure better uniformity with minimum System Lumen of 4200 Lumens with CRI > 80, Color temperature 5500- 6500 K, THD < 10% and PF > 0.95,IP20 , IK03.Life class of 50,000 hrs. @ L70, Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection: 4 KV; Protection : Reverse Polarity, Open & Short Circuit. DRIVER SAFETY REQUIREMENT STANDARDS :IS 15885-2-13, TEST REPORT TO BE SUBMITTED; PHOTO BIOLOGICAL SAFETY NORMS: IS 16108, TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE LM 80 FOR LED SOURCE. Fixture with R mark and registration number. As per Crompton Cat Ref: LCTLRNE-40-CDL(1x4) with 5 Year warranty or equivalent in Havells/Philips
Supply, Installation, Testing and commissioning of 120 W LED Flood Light for Epoxy powder coated die-cast aluminium housing (ADC 12) with aesthetically designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. M16 size gland is used for cable entry and provision for loopin-loopout, System wattage consist of 120 W with composite Wide Beam PC Lens cover to ensure better uniformity Powered by an Isolated integral IP 66 Potted electronic driver with 4 KV Surge Protection (SMPS based constant current supply) with lower THD, Output Short Circuit, Over Voltage, Surge Protection. CCT 5700 - 6500 K , CRI >70, THD < 10%, PF >.95, IP65, IK07 .Life class of 50,000 hrs @ L70, Operating Temperature :-10 TO + 45 DEG.C TEST REPORT TO BE SUBMITTED; Test Report LM 79 FOR Complete LED Luminaries and LM 80 for LED Chip as well as PHOTO BIOLOGICAL SAFETY for LD chip. LED fixture with BIS R mark and R Registration no. must for each Fixture. As per Crompton Cat Ref: CFS-504-120-57-60D-SL-GL-NSG (120 lm/w 10KV SPD ) with 5 Year warranty or equivalent in Havells/phillips.
S & F in repairs and connecting up LED 20 watt fitting 6500K 4 feet with 120 lumen/watt,aluminum housing extruded in thermal conductive material with powder coated in white colour Extruded serration High Optically efficient plastic FR grade material in milky white,Spring Steel Nickel plated,Inj. Moulded engineering plastic Brown in colour Five year written warranty from manufacturer including 23/00.0076 size 3 core copper flexible wire from connector to ceiling rose/adoptor including all necessary fixing arrangements complete. Crompton cat No CCS-100-20-65-HL2-DP-NWH or equivalent in Philips/Havells/Wipro ).
Supply and fix Flame proof fitting ,30 Watt complete, Lumens >100 lm /watt , 5 year manufacturing warranty and life class of 50000 hrs. All as specified and directed by Engineer-in-Charge. MAKE : Crompton, Model No. FWL1318-30-CDL-M or equivalent in Phillips / HAVELLS.
Supply and fix Surface/suspended linear 4ft luminaire 40w made of Aluminum extruded housing in white powder coated finish and plastic moulded end caps.High transmittance PMMA opal diffuser.High efficiency long life LED package in integral module with lumen efficacy > 100 Lm/W and viewing angle of 120° to ensure better uniformity.Powered by an integral isolated low THD electronic LED driver ( SMPS based constant current supply) with output short circuit protection, surge protection. Lumen Output of 4000 lumens.CRI > 80, Color temperature 5700K, THD <10% and PF >0.90,IP20,IK03.Life class of 50,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection:3 KV; Protection : Reverse Polarity, Open & Short Circuit. DRIVER SAFETY REQUIREMENT STANDARDS :IS 15885-2-13, TEST REPORT TO BE SUBMITTED; PHOTO BIOLOGICAL SAFETY NORMS: IS 16108, TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE LM 80 FOR LED SOURCE. As per Crompton Cat Ref: CCP-143-36-CDL-SL-NWH with 5 Year warranty or equivalent in Havells/phillips
Supply and fix in replacemant Flame proof LED lowbay light 40 watt with aluminium housing & toughned glass suitable for hazardous area lighting IP-55/IP-66, 100 lm /watt
Supply and fix 20W Surface / Wall mounted Decorative linear 4 ft LED integrated batten made of Extruded AL Hsg channel for efficient heat dissipation & diffuser part in reeded opal finish with Decoartive end caps . High efficiency long life LED package in integral module with lumen efficacy > 130 Lm/W and viewing angle of 120° to ensure better uniformity.Powered by an integral isolated low THD electronic LED driver ( SMPS based constant current supply) with output short circuit protection, surge protection.Can be fixed directly into the wall/ ceiling by means of mounting SS clips provided with the fixture. MIn System Lumen Output of 2200 lumens ( Max 20 w ) .CRI >80, Color temperature 5700K, THD < 15 % and PF>0.95,IP20 . Life class of 50,0000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection:3 KV; Protection : Reverse Polarity, Open & Short Circuit. TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE LM 80 FOR LED SOURCE. As per Crompton Cat Ref: CCS-100-20-65-HL2-DP-NWH with 5 Year written warranty from manufacturer or equivalent in Havells/Philips
Supply and fix 10w Surface / Wall mounted Decorative linear 2 ft LED integrated batten made of Extruded AL Hsg channel for efficient heat dissipation & diffuser part in reeded opal finish with Decoartive end caps . High efficiency long life LED package in integral module with lumen efficacy > 100 Lm/W and viewing angle of 120° to ensure better uniformity.Powered by an integral isolated low THD electronic LED driver ( SMPS based constant current supply) with output short circuit protection, surge protection.Can be fixed directly into the wall/ ceiling by means of mounting SS clips provided with the fixture. MIn System Lumen Output of 1000 lumens ( Max 10w ) .CRI >80, Color temperature 5700K, THD < 15 % and PF>0.95,IP20 . Life class of 50,0000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection : 2- 3 KV; Protection : Reverse Polarity, Open & Short Circuit. TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE LM 80 FOR LED SOURCE. As per Crompton Cat Ref: CCS-103-10-65-SL-DP-NWH with 5 Year warranty from manufacturer or equivalent in havells/Philips
Supply, Installation Bldgs security lights LED street light fittings 45 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No TRP-415-45-57-SL-LM-NBK or equivalent in Havells/ Phillips.complete all as specified and directed by Engineer- in-charge.
Supply and fix in replacemant decorative ultra slim square profile linear Light Linea lighting fixture extruded polycarbonate, enviromental frendily, energy efficent ready to use pack 5W LED 6000K, complete all as specified and directed by Engineer-in-Charge. MAKE : Crompton, Model No.CCS-103-5-65-SL-DP-NWH or equivalent in Philips/ HAVELLS.
Supply & Fix LED down light 6 watt slim compact with surface mounting aluminium die cast edge lit panel, recess mounted square fixture with opal diffuser and separate electronic driver.including all electrical connections. of Make Crompton cat pt LSCRM-6-CDL or equivalent in Havells/ Philips complete all as specified and directed by Engineer- in-charge.
Supply & Fix LED strip light with driver 2.5 Watt flexicon LED USB TV RGB strip Make Crompton Cat Pt No LSTGL20-WW (Strip)and LSTDRV-12V-2A (driver)complete all as specified and directed by Engineer- in-charge.
Supply and fix in repair Switch piano flush type single pole one way 5 Amp , Make Anchor/ Havells Rio,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular switch one way 6 Amp,1 Module , Make Anchor/Roma/Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular switch one way 16 Amp, 1 Module , Make Anchor/ Roma,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular bell push 6 Amp,1 Module , Make Anchor/ Roma/Legrand,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular Fan regulator electronic step type 230 V 2 Module. Make : Anchor/Roma / Legrand Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular Socket outlet 6A/16 Amps 2/3 pin combined 2 module Make : Anchor/Roma. ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular Socket outlet 6 Amps 2/3 pin combined 2 module Make : Anchor/Roma ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Bell push flush type 5 Amps. Make : Anchor/Havells Rio,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Fan regulator electronic step type 230 V. 120W . Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Bell buzzer,AC 230 Volts single pole. Make : Anchor/Press Fit,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Socket out let 2 in 1, 5 pin 5 Amps flush type. Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair PVC Box with Switch socket combination outlet 5 pin 6 Amps 16 Amps 2 in 1 flush type.Make: Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.Make
Supply and fix in repair PVC Box with Switch socket combination outlet 5 pin 5 Amps 2 in 1 flush type Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Switch socket combination outlet 5 pin 6 Amps 16 Amps 2 in 1 flush type.Make: Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Switch socket combination outlet 5 pin 5 Amps 2 in 1 flush type Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Indistrial Plug top 3 pin 5/6 Amps as per sample.
Supply and fix in repair Industrial Plug top 4/5 pin 15 Amps as per sample.
Supply and fix in repair Plug top 3 pin 5 Amps Make Anchor/Leader/Cona
Supply and fix in repair Plug top 3 pin 15 Amps Make Anchor/Leader/Cona
Supply and fix in repair Lamp holder PVC/polycarbonate insulated body with back plate suitable for angle fittings. Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair LED Lamp 9 watt/12 watt Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair LED Lamp 30/35 watt pin/screw as reqd at site Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Ceiling rose surface type, PVC/Polycarbonate isolated body size 50x28 mm three terminals. Make : AnchorHavells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Fixing only in repairs Miniature Circuit Breaker, 10 Ampere, MCB SP 10 Amps 240 volts Type C series.
Fixing only in repairs Miniature Circuit Breaker, 16 Ampere, MCB SP 16 Amps 240 volts Type C series.
Fixing only in repairs Miniature Circuit Breaker, 20 Ampere, MCB SP 20 Amps 240 volts Type C series.
Supply, Installation, Testing and commissioning of LED Bollard camber light of wattage 9 w, with cast aluminium housing and polymer diffuser, suitable for B22 9W , 600 mm length. Make Shakti CAT No SZPGBMX009-C or equivalent in Havells/ Philips/Crompton.complete all as specified and directed by Engineer- in-charge.
M&L for taking down outdoor split type air condition of any type/make/capacity after disconnecting/ pumpdown slpit AC all electrical connection from wall at any height and refixing the same out door unit of split AC duly mounted on heavy duty outdoor powder coated stand /bracket using suitable size anchor fastner and connecting up electric supply and testing for smooth running complete all as specified and as directed by Engr- in - charge. Note: Contractor has to make own arrangement for working at height. cost of bracket and gas charging are deemed to be included in quoted rate.
Supply and fixing flexible copper conductor with single core having cross sectional area 70 sqmm, 1100 volt, laid in wall/ trench/duct/floor or passing through pipe all as specified and as directed byengr-in-charge.
Fixing only of tube light , POP light, ceiling light, Focus light or any type of light to be fix on wall /ceilling with the help of suitable size of nut bolt washer etc including all electrical connection connection as required at site ( Note - Material /store will be issued under schedule be )
Supply and fix in repair MCB SPN 32 to 40 Amps 240 volts 10 KA. Cat Part No-408617 Make : Legrand /Standard/L & T,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB TPN 32 to 40 Amps 240 volts 10 KA. Cat Part No- 408680 Make : Legrand Standard L & T,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB TPN 63 to 100 Amps 240 volts 10 KA. Cat Part No-408683 Make : Legrand Standard /L & T,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s 2 way 240 volts. Make : Standard/HPL/Legrand,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s SPN, with 200 amps rated bus bar , 4 way ,240 volts double door. Make : Standard/HPL/Legrand.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s SPN, with 200 amps rated bus bar ,8 way ,240 volts double door. Make : Standard/HPL/Legrand.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s TPN, with 100 amps rated bus bar , 4 way ,415 volts double door. Make :Standard/Legrand/L&T.,Complete all as specified & as directed by Engineer-In-Charge.
Fixing in repair MCCB, 100 Ampere , 4 Pole 16KA
Fixing in repair MCCB, 125 Ampere , 4 Pole 16KA
Fixing in repair MCCB, 200 Ampere , 4 Pole 16KA
Fixing in repair MCCB, 250 Ampere , 4 Pole 16KA
S&F MCCB TP ,Thermal magnatic with enclouser , 415 Volts,50 HZ, 30 KA, 100 Amps DU-100H Cat No CM9789400k2 of L&T or equivalent Model of Legrand, Siemens.,Complete all as specified & as directed by Engineer-In-Charge.
Supply & Fix in repairs MCB TP 32 Amps 415 volts 50HZ of Legrand Cat No 4086 58 or equivalent in L&T /Seimens. ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair PVC rectangular board 100 mm x 100 mmx 50 mm deep. Make : Press Fit or equavelent ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair PVC rectangular board 175mm x 100mmx50mm deep. Make : Press Fit or equavelent.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair PVC rectangular board 200mmx150mmx50mm deep. Make : Press Fit or equavelent.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair PVC rectangular board 250mmx200mmx50mm deep. Make : Press Fit or equavelent .
Disconnecting all existing electric supply and taking down carefully ceilling/ exhaust/cabin/wall fan of any make and sweep dismantlling blades, checking for repairs required ( Note: Repairs/ Replacement of spares shall be carreied under appropriate items. for C/fan, Exhaust fan . The item will be taken down and brought to MES yard for repairs, i.e overoiling,rewinding,replacement of bush/bearing, brazing/machine work, painting and after testing at MES store yard Cost for transportation from site to MES store yard & vice versa is deemeed to be included under the quoted rate.
Hanging/fixing only ceiling fans of any make and sweep connecting the complete with & including provision of copper conductor cord 3 core PVC insulated and sheathed 0.5 Sqmm from ceiling rose to exhaust fan connector and testing as directed and specified( Note: The exhaust fan shall be fitted with new set of clamps, rubber shackle split pins and top and bottom nut bolts etc.)
Hanging/fixing only exhaust/cabin/wall fan of any make or sweep connecting up complete with and including provision of copper conductor cord 3 core PVC insulated and sheathed from celing rose to fan connector & testing as directed and specified. ( Note: The Exhaust fan shall be fitted with new set of washers, nuts, rubber packing etc.)
M & L for Opening up of fan, motor of fan, cleaning stator,rotor, cleaning of all parts greasing oiling of bushes and bearing reassembling and testing for smooth functioning for celling fan 1200 mm sweep Note;-rate shall be quoted for taking down & refixing of ceiling fn afterrepair work
All as per item No 103 but for Exhaust fan 300/375/450mm sweep
All as per item No 103 but for Table/pedastal fan/Air circulator fan 400 /600/750 mm sweep
M & L for removing the burnt winding and rewinding the fan with super enamelled copper winding wire of suitable gauge, insulating, putting sleeves etc complete all as specified and directed by Engineer-in-Charge for celing fan 1200 mm sweep
All as per item No 109 but for Exhaust fan 300/380 mm sweep
All as per item No 109 but for Exhaust fan 450 mm sweep
All as per item No 109 but for Table/pedastal fan/Air circulator fan 400 /600/750 mm sweep
Supply & Fixing bearing/ busg in repairs or replacement for celing fan 1200 mm sweep
All as per item No 113 but for Exhaust fan/Air ciculator fan 300/400/450/650/750 mm sweep
S&F in repairs Fan capacitor 2.5 MFD, 250 V.
S&F in repairs capacitor 4.0 MFD, 250 V Heavy duty.
Suppy & fixing only gear assembly of table/wall mounted/air circulator/ pedastal fan suitable for easy air circulatig movements of any size of fan
Supply and fixing in replacement fan motor suitable for PCV exhaust fan 230/300 mm complete Note;-rate shall be quoted for taking down & refixing of exhaust ceiling fn afterrepair work
S&F fan clamp assembly consisting of nut, bolts, washers and split pin alongwith suitable size rubber real for mounting of fan down rod.
Disconnectiing of all electrical connections of the existing ceiling fan and taking down ceiling fan (any type/ sweep) from the ceiling and removing the existing down rod of the ceiling fan .
M&L for down rod 1000 mm long for ceilling fan of any make and sweep made out of medium grade GI tubing 15 mm dia duly painted with two coats of enamel paint and provision of holes for electric wire at top and bottom also arrangemnts for fittment of ceiling fan motor,clamp assembly and condensor all specified and directed by Engineer in charge
All as per item No 121 do but 1500 mm
S&F copper flexible twin twisted cable of size 23/ 0.0076 .
S&F louver complete for exhaust fan of size 300mm , made of iron/ aluminium (As Sample approved ) of matching colour with exhaust fan of suitable size ,duly grauted bolts in the wall fixed with nuts, bolt and washers and making good the plastering by matching colour with existing colour to the disturbed surface of wall complete
S&F louver complete for exhaust fan of size 450mm , made of iron/ aluminium (As Sample approved ) of matching colour with exhaust fan of suitable size ,duly grauted bolts in the wall fixed with nuts, bolt and washers and making good the plastering by matching colour with existing colour to the disturbed surface of wall complete
M&L for Cutting 450/300 mm size hole for exaust fan in existing wall and making good with plastering and matching colour,(Hume pipe cut to the round sling sleeve of the required dia will be used in the wall to achive perfect round ) then Plaster the cut edges and surrounding area to restore the wall surface and apply surface treatment and paint the patched area using match colour and texture to blend seamlessly with the existing wall. Note Remove all debris and clean the site after work.
S&F ceilling fan BLDC 1200 mm sweep operated on 230/240V AC,26 W Single phase electric supply ,5 star with remote in white in colour complete including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to fan connector including writing MES No. on ceiling fan white synthetic enamelled paint complete all as per specified and directed by Engr-in- Charge . Make Havelles cat pt- Efficienia Neo BLDC or equivalent in Orient n & crompton
S&F Exhaust fan 300 mm sweep, 4 blade ( Mettallic type ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connectorcomplete all as per specified and directed by Engr-in- Charge . Make Crompton, havells , Usha
S&F Exhaust fan 450 mm sweep, 4 blade ( Mettallic type ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connectorcomplete all as per specified and directed by Engr-in- Charge . Make Crompton, havells , Usha
S&F Exhaust fan 300 mm sweep, 4 blade ( PVC ) with louvers & suitable size aluminium frame to fix it in wall/window, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector complete all as per specified and directed by Engr-in- Charge . Make Crompton, havells , Usha
S&F Exhaust fan 250 mm sweep, 4 blade ( PVC ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector complete all as per specified and directed by Engr-in- Charge . Make Crompton, havells , Usha
S&F Exhaust fan 200 mm sweep, 4 blade ( PVC ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector complete all as per specified and directed by Engr-in- Charge . Make Crompton, havells , Usha
Disconnecting carefully water and electric connection from geyser, taking down carefully storage type water heater of any type and capacity and dismantling geyser by removing glass wool, thermostat, heating element for checking of defects, repalcement of defective thermostat, heating element of any capacity, indicating lamps (round/rectangular) flange assembly, top or bottom cover half round plate glass wool etc where required, cleaning of inner container by anti corrosive liquid removing scales repair by brazing, Re-assemblong of geyser and refixing at its original location and testing complete(Replacement of spares such as heating element , thermostat, indicating lamp, top and bottom cover, half round plate, glass wool heating flange assembly will be measured and paid under relevent items) all as directed
M&L for replacement of heating assembly (flange) made out of copper/steel as existing including heat resistance and leak proof gasket suitable for 25 ltrs capacity geyser all as directed Make : Ditzs/ Racold/ Shakti/Spheroat
All as per item No 134 above but for 35/50 lts capacity
S&F in repair thermostat having range 0 to 100 C for geyser as original size of 25/35/50ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
S&F in repair heating element 2 KW with round or triangular base for 50 ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
S&F in repair lamp indicator with red colour 230 volts complete with fixing arrangement round or rectangular shape and size as per existing geyser suitable for Ditzs/ Racold/ Shakti/Spheroat Make.
metro electrical services (BID ID -3356880)
SHRI SULAI ELECTRICALS (BID ID -3348208)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .