| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 LAccepted-AOC 143 C DR RAJENDRA ROAD KOLKATA 700020 | KOLKATA | KOLKATA | WEST BENGAL | 700020 | L1 | Accepted-AOC AOC | |
| 2 | L2₹1.5 L+₹20,200 (15.6%)Rejected-Finance BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L2 | Rejected-Finance Not L1 bidder | |
| 3 | L3₹1.6 L+₹26,700 (20.6%)Rejected-Finance 103 1A RAJA DINENDRA STREET KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance Not L1 bidder | |
| 4 | L4₹1.6 L+₹33,375 (25.7%)Rejected-Finance | L4 | Rejected-Finance Not L1 bidder |
| Sl No | Description | Qty | Unit | UNIVERSAL SALES L4 | S.R. REFRIGERATION AND APPLIANCES L3 | NATIONAL AIRCON L2 | BIKASH ENTERPRISE L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply & installation of 2 TR Split type Air conditioner machine having cooling capacity not less than 7033 W , BEE rating not less than 3 star with super tropical-return cooled rotary compressor, 26017 Btu/h, indoor unit airflow 1450/m3/hr, CMH, Super turbo DC Fan Motor speed Auto/High/Low, Sound level 48/42/39 dB, Louver swing 3D, current minimum 8.0 & maximum 9.2 Amps. LCD remote & all other accesories suitable for refrigerant-R32A, 5 point Multi Port Refrigerent inject coil, outdoor & indoor unit coil must be made by copper tubes incl 10 ft. installation kit like-refrigerent pipe with rubber insulation & control cable. ( Make-Carrier, Model: 24K Durawhite DX R32). | 2 | Set | 76,500 ₹1,53,000 | 75,000 ₹1,50,000 | 73,000 ₹1,46,000 | 60,000 ₹1,20,000 Lowest |
| 2.00 | Supply & drawing 4 core 1.5 sq. mm. P.V.C. insulated wire with appropriate size copper lag for communication outdoor & indoor unit. (Heavels / Finolex/ KEI). As per direction by EIC. | 20 | mtr. | 145 ₹2,900 | 140 ₹2,800 | 120 ₹2,400 | 110 ₹2,200 Lowest |
| 3.00 | Supply & laying of Refrigerent Copper piping with 9 mm thick nitrile rubber insulation (Class 0)[Make : Supreme/Aroflex] with wrapping by tape, minimum thickness of piping is 0.85 mm. Liquid pipe 6.35 mm.(1/4") Gas pipe 15.88 mm. (5/8")[Make : Ryoku/Totaline]. As per dirwection by EIC. | 15 | mtr. | 280 ₹4,200 | 240 ₹3,600 | 100 ₹1,500 Lowest | 410 ₹6,150 |
| 4.00 | Supply and laying of Drain water pipe work out of PVC /HDPE hard pipes of 16 mm sizes incl. Fitting accesories, bends, elbows,tees, cutting the floorby expert labour and mending good the damages. | 25 | mtr. | 120 ₹3,000 | 1 ₹25 Lowest | 1 ₹25 Lowest | 55 ₹1,375 |
| 5.00All rates should be inclusive of GST & LWC. | |||||||
Tender Value
Refer Docs
EMD Value
₹3,000
Closing Date
22 Sept 2023, 6:00 pmClosed
Assistant Engineer, Dhana Dhanya Electrical Sub-Di
Office of the Assistant Engineer, P.W.Dte. Dhana Dhanya Electrical Sub-Division PWD Office Building (2ndFloor), 32, Belvedere Road, Alipore,Kolkata-27
SITC of Two nos. Split type Air conditioner machine at Sr. IAS Residence Building, 12 B C Road, Kolkata-700019
2023_WBPWD_567028_1
10/Q/AE/DDESD/PWD/2023-24
Open Tender
A/C ORG
Item Rate
7 days
Office of the Assistant Engineer, P.W.Dte. Dhana D
Please refer Tender documents.
9 documents required · 9 mandatory
₹3,000
3 Sept 2026
11 Sept 2023
26 Sept 2023
12 Sept 2023
22 Sept 2023
12 Sept 2023
Amount
Supply & installation of 2 TR Split type Air conditioner machine having cooling capacity not less than 7033 W , BEE rating not less than 3 star with super tropical-return cooled rotary compressor, 26017 Btu/h, indoor unit airflow 1450/m3/hr, CMH, Super turbo DC Fan Motor speed Auto/High/Low, Sound level 48/42/39 dB, Louver swing 3D, current minimum 8.0 & maximum 9.2 Amps. LCD remote & all other accesories suitable for refrigerant-R32A, 5 point Multi Port Refrigerent inject coil, outdoor & indoor unit coil must be made by copper tubes incl 10 ft. installation kit like-refrigerent pipe with rubber insulation & control cable. ( Make-Carrier, Model: 24K Durawhite DX R32).
Supply & drawing 4 core 1.5 sq. mm. P.V.C. insulated wire with appropriate size copper lag for communication outdoor & indoor unit. (Heavels / Finolex/ KEI). As per direction by EIC.
Supply & laying of Refrigerent Copper piping with 9 mm thick nitrile rubber insulation (Class 0)[Make : Supreme/Aroflex] with wrapping by tape, minimum thickness of piping is 0.85 mm. Liquid pipe 6.35 mm.(1/4") Gas pipe 15.88 mm. (5/8")[Make : Ryoku/Totaline]. As per dirwection by EIC.
Supply and laying of Drain water pipe work out of PVC /HDPE hard pipes of 16 mm sizes incl. Fitting accesories, bends, elbows,tees, cutting the floorby expert labour and mending good the damages.
All rates should be inclusive of GST & LWC.
NATIONAL AIRCON
S.R. REFRIGERATION AND APPLIANCES
UNIVERSAL SALES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .