Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-Finance GE W COLABA MUMBAI | CHANDRAPUR | MAHARASHTRA | 441205 | L1 | Accepted-Finance Lowest one | |
| 2 | L2₹29.6 L+₹2.5 L (9.28%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹29.8 L+₹2.7 L (10.1%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹30.0 L+₹2.9 L (10.7%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹32.7 L+₹5.6 L (20.6%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
22 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW NOFRA
DR HOMI BHABHA RAOD NEW NAVY NAGAR COLABA MUMBAI-05
REPAIR MAINT OF MES INSTALLATIONS AND MAIN SEWAGE LINES IN NOFRA AREA UNDER GE NW NOFRA COLABA MUMBAI
2022_MES_543319_1
8035
Open Tender
Civil Works
Item Rate
240 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹80,000
Yes
1 Sept 2022
4 Aug 2022
27 Aug 2022
4 Aug 2022
22 Aug 2022
16 Aug 2022
4 Aug 2022 - 15 Aug 2022
Amount
Dismantling brick work built in cement mortar and removing the rubbish outside MD land complete all as specified and directed by Engineer in charge.
M&L for brick work with sub class B brick straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer in charge.
M&L for Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work finished even and smooth (without using extra cement) including taking down existing plaster of any thickness complete all as specified and directed by Engineer in charge.
M&L for Cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete complete all as specified and directed by Engineer in charge.
M&L for Plain cement concrete 1:3:6 type-C2, using 40mm graded stone aggregate as in bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested in for 300mm dia SWG pipe complete all as specified and directed by Engineer in charge.
M&L for Plain cement concrete 1:3:6 type-C2, using 40mm graded stone aggregate as in bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested in for 150mm dia SWG pipe complete all as specified and directed by Engineer in charge.
M&L for Salt-glaged stoneware drain pipes 150 mm internal dia, laid in trenches and jointed as specified including demolition of existing drain pipe complete all as specified and directed by Engineer in charge.
M&L for Salt-glaged stoneware drain pipes 300 mm internal dia, laid in trenches and jointed as specified including demolition of existing drain pipe complete all as specified and directed by Engineer in charge.
Taking down CI/rain water pipes/PVC pipes (any size or pattern) including all fittings, heads, shoes, bends, swan necks, etc., including cleaning etc complete all as specified and directed by Engineer in charge.
S&F 100 mm dia sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste fixed to wall upto 16th floor.
S&F 75 mm dia sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste fixed to wall upto 16th floor.
S&F in repair 100 mm dia sand cast CI bend of any radius with ovel access door and jointed with neat cement paste.
S&F in repair 100 mm dia branch piece single branch of any radius with ovel access door and jointed with neat cement paste.
S&F in repair 75 mm dia branch piece single branches any radius fixed to ovel acess door and jointed with neat cement paste.
S&F in repair 75 mm dia sand cast CI bend of any radius with ovel access door and jointed with neat cement paste.
S&F 160mm dia PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wall including GI clamps of approved shape and size approved by GE. Make : SFMC, Prince, Finotex.
S&F 160mm dia PVC (SWR) bends/shoes any radius. Make : SFMC, Prince, Finotex.
M&L in repair cast iron Nahani trap 100mm including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
S&F in repairs cast iron manhole covers alongwith frame grade A-35 T/A-350 KN, machined each exceeding 5 Kg by weight complete all as specified and directed by EIC.
Taking down existing cement or cement lime plaster and preparation of surfaces of walls of any description incl racking out joints backing for scrubbing down with water including rubbish out side MD land complete all as specified and directed.
M and L for rendeing 20mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two coats 15mm thick and 5 mm thick each coat mixed with integral water proofing compound at the rate of 3% of cement or as per manufacturers instructions Note: Integral water proofing compound shall be measured & paid separately)
Preparation of new plastered or unplastered surfaces and apply two coat of acrylic emulsion exterior grade (100%) on wall over a coat of primerall as specified and directed
M & L for precast cement concrete type B1 1:2:4 (20mm graded aggregate) in landings,cover slabs (for manholes etc) chullah hoods,chajjas,water roughs, mangers, shelves and similar articles with plain faces including necessary form work and reinforcement.
M & L for Non-Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06sqm but not exceeding 0.11 sqm over & including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling complete all as specified and as directed by the Engineer-in-Charge Make: Somany, Kajaria, Orient bell.
M & L Glazed ceramic tiles in vertical surfaces of size 350x250mmx7mm thick/450x350x7 mm th including over 10mm thick Screed bed or bedding layer in CM 1:4 for laying tile finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling complete all as specified and as directed by the Engineer-in-Charge Make: Somany, Kajaria, Orient bell.
S&F in repair wash hand basin vitreous china white flat back or angle type of size 580mmx450mm including waste chain and plug and porcelain stopper, a pair of brackets or errecting stand and etc. complete all as specified and directed. Make : Jaquar ESSCO Cat part No. ECS-801 or Grohe
S&F in repairs white vitreous china wash down water closet pan (pedestal pattern) including fixing bolt with and including plastic water closet seat cover closed pattern with flat bottom and cover and MSCP aluminum hinges device complete connecting to P or S trap all as specified and directed. Make : Jaquar ESSCO Cat Part No. ECS-801 or Grohe or Kohler.
S&F in repairs PVC Valveless, 10 Ltr capacity, syphonic action type, flushing cistern low level all accesories complete all as specified and directed. Make : ESSCO Cat Part No. WHE-183L or equivalent in Jaquar , kohler , Grohe
S&F in repair vitrous china squatting pan 'Orrisa Pattern' size 580x440mm white with integral foot rest including connecting and necessary provision of lime concret complete all as specified and directed by Engr-in-Charge
S&F in repairs Kitchen sink with drainage board made of stainless steel 1mm thick with plugs washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mmx420mm bowl size 410x330x160mm etc Complete all as specified and as directed. MAKE : Cera Cat Part No B45/2203 Matt Finish/ Kohler or Diamond Blanco
S&F in repairs plastic water closet seat covers standered closed pattern with flat bottom and cover and MS chromium plated or aluminised hinging device complete all as specified and directed. Make : Jaquar ESSCO Cat Part No. ECS-WHT-109N(Seat cover) or equivalent in Hindware, Kohler .
Treatment of sunken floor slab compraises of the following specifications and all as specified :-
(i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout (Cost cutting holes and pipes shall be measured and paid separately)
(ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out.( WPC shall be measured & paid separately)
(iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty.
(iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean.
(v) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.(This item shall be measured and paid separately)
(vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.( WPC shall be measured & paid separately)
(vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (this item shall be measured & paid separately)).
Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. Cost of testing is inclued in the rates quoted above.
Cutting holes in bricks or RCC walls exc half brick built in cement mortar including making good after inserting and setting spouts all as specified.
M & L GI pipe 50mm dia medium grade laid on sunken floor complete all as specified and direced by EIC.
M & L all pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round including painting with anticorrosive paint
M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. Make :- Pidilite, Sico, Dr fixit, Shalicem
M & L Injection grouting in RCC slab shall be cast/laid to the slope as directed/as per site conditions. After RCC slab is laid, cured and fully set, water shall be ponded in the sunken slab portion as per specified ponding test. The location of seepage/leakage, if any, shall be identified and marked. The portion of the slab where leakage/seepage is observed shall be repaired with grouting at contractor's expences. The area of dripping/leakage shall be cleaned to expose the surface. Mark the spots for injection grouting. If leakage is through a crack, mark grouting points along the crack in a staggered manner. If the leakage is across the area mark grouting spots in a grid pattern. Drill grouting holes so as to neatly fit the injection packers. Drilling to be done at an angle of 45 to the plane of grouting surface. Fix PVC/MS nozzles in the low viscosity, polyurethane resin/epoxy grout using a grouting pump. Repeat the process after 1 or 2 days if the leakage continues at some point. allow to cure for 24 hours and seal the grouting holes appropriately using epoxy putty etc complete all as specified and as directed. Make :- Dr Fixit, Pidilite
Supply only Integral water proofing compound. Make :Pidilite, Dr Fixit, SICO
Demolition of Cement concrete in any description and in any position not other wise specifically provided directed by Engineer-in-Charge and removal of debris to out side MD land.
M&L PCC 1:7:12 with brick aggregate as in lean concrete/filling concrete
Providing Cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in copings and sides of drain/manholes cover etc and like including weathering slightly rounded or chamfered angles and throating as directed.
M & L for 100 mm th pcc 1:3:6, grade B-1 (40 mm graded aggregate) type C-2 in sub bases and sides of paver block including demolition.
M &L for 80 mm thick interlocking paver block machine pressed of any size and shape as approved by GE incl 50mm sand cushion and dismantling of old paver blocks and removal to store
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws in repair, complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
S& F for Framed work such as grills, gratings, angle irons, pipe sections, railings etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors ladders; framed balusters; walk ways; railings; framework of water tanks, embedded in concrete and similar work con- forming to Fe.290.Gde-E-165 at any height including necessary scaffolding complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified incl all necessary scaffolding etc.
M&L for Chequered cement concrete tiles 300x300x25 mm etc. glosy finish set and jointed and pointed in neat cement slurry in floor with grey cement and pigment over and including screed bed of 20mm thick in CM 1:4, including dismantling complete all as specified and as directed by Engr in Charge.
SAHI SAGAR ENTERPRISES
SHRI SAI ENTERPRISES
Nagma Enterprises
Angrahit Services Trading Co
Unitech Enterprises
SR Construction
SHREE JAGDISH FURNITURE CO.
Genius Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .