Tender Value
₹79.5 L
EMD Value
₹1.4 L
Closing Date
30 Jun 2025, 6:00 pmClosed
HQ CWE (U) Delhi Cantt-110010
HQ CWE (U) Delhi Cantt-110010
REPAIR AND MAINT OF 33 KV CIRCUIT BREAKER YARD MAINT AND TRANSFORMER REPAIR MAINT AND REPAIR OF 11 KV VCBs OUTGOING 33/11 KV UG CABLES AND CONNECTED ITEMS OF KHYBER GRID UNDER AGE ELECT SUPPLY (SLDC) UNDER GE (U) ELECT SUPPLY DELHI CANTT-10
2025_MES_712418_1
CWE (U)/D-07/2025-26
Open Tender
Civil Works
Works
180 days
HQ CWE (U) Delhi Cantt
Please refer Tender Documents
9 documents required · 9 mandatory
₹1,000
GE(U) Elect Supply
₹1.4 L
Yes
4 Aug 2025
4 Jun 2025
7 Jul 2025
4 Jun 2025
30 Jun 2025
25 Jun 2025
Amount
Material and labour for servicing /testing of line breaker/control panel, transformer breaker, line circut brakers including outdoor CT, PT and relays in control panel of outdoor VCB of capacity 800 Amps/1200 Amps / 2000 Amps and rating 36 KV complete as details mentioned as under (800 Amps x 01 Nos, 1250 Amps x 07 Nos and 2000 Amps x 3 Nos) :- (a) Details of servicing of breaker :- (i) Checking of Closing/Tripping coil assembly (ii) Adjustment of mechanism if required. (iii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iv) Checking the contact for wear. Replace if the contact piece has worn out. (v) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (vi) Check for rust and wear. (vii) Checking of spring charge mechanism (viii) Visual check for rust and deformation. (ix) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (x) Check for loosened connections, rust, damaged lead wires. (xi) Checking of control circuit & tighten the connections if any.
Material and labour for servicing /testing of breaker/control panel including CT, PT and relays in control panel of VCB of capacity 2000 /800/630 Amps and rating 11 KV complete as details mentioned as under (630 Amps x 05, 800 Amps x 15, 1250Amps x 01 and 2000 Amps x 03):- (a) Details of servicing of breaker :- (i) Adjustment of mechanism if required. (ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (iv) Check for rust and wear. (v) Check Spring Tension and pitting of the Cluster Contacts. (vi) Visual check for rust and deformation. (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (viii) Check for loosened connections, rust, damaged lead wires. (ix) Check whether the contacts are damaged by arcing. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Checking of Jaw Contacts Conditions and repair/adjust. (xiii) Replace the jaw contacts,If required.
(xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish. (xv) Replacement of Dashpot/shock absorbers . (xvi) Replacement of carbon brush of spring charging motor (b) The following test shall be carried out:- (i) Primary Injection Test of CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance (vi) Tripping coil resistance. (c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault relay (d) Testing of followig Aux relay (i) DC Supply supervision relay. (ii) Master trip relay
Supply installation, testing and commissioning in replacement Potential Transformer (PT) oil cooled out door single phase ( Earthed type) of voltage ratio 33 KV/110 V class 3P - 0.5-3, burden 50 VA insulation level of 70/170 KV as specified below:- (a) Normal System Voltage-33 KV (b) Highest System Voltage-36 KV (c) Rated Primary voltage- 33 KV/√3 (d) Rated secondary voltage- 110 V/√3 (e) Nos of Lt winding 2 (f) Metering Core Accuracy class - 0.5 (g) Metering Core Rated Burden- 50 VA (h) Nos of Phase- Single (Earthed Type) (j) Protection core accuracy class - 3P (k) Protection core rated Burden - 50 VA (l) Rated Voltage Factor - 1.2 continuous & 1.5 for 30 Sec (m) Insulation Level- 36/70 KV.170 KVP (n) Temp rise at rated contineous thermal current over ambient at site - 45 0C (o) Porcelain Bushing type - Hollow Cylinder (p) 1.2/50 mcro second impulse withstand test vol -170 KV (Peak) (q) Creepage distance of HV bushing - 900 mm (min) (r) Primary & Secondary winding material - Copper
Supply, installation, testing and commissioning in replacement 33 KV current transformer oil cooled out door single phase, oil immersed and self cooled type of ratio 800-400/1-1-1-1 suitable for metering and protection equipment installed on control panels terminal block as specified below :- (a) Normal System Voltage-33 KV (b) Highest System Voltage-36 KV (c) Rated Primary current- 800-400 Amp (d) Rated secondary current- 1 Amp (e) Nos of Core - 4 (f) Core01: Accuracy class 5P10, 10VA, ALF ≥10 (g) Core02: Accuracy Class 1.0, 10VA, ISF ≤ 5 (h) Core 03 Protection core accuracy class -PS,Protection knee point voltage- 300 Volt at lower ratio (j) Core 04-Spare (k) Continuous thermal current rating 120 % of rated primary current (l)Temp rise at rated contineous thermal current over ambient at site - Less than or equal to 45 degree C (m) Insulation Level- 36/70 KV.170 KVP
(n) 1.2/50 Micro second impulse withstand test voltage- 170 KV (peak) (o) Short time thermal current rating for one second - 25 KA/1 Second (p) Dynamic Current Rating - 62.5 KA ( peak) (q) Porcelain Bushing type - Hollow Cylinder (r) Creepage distance of HV bushing - 900 mm (min) (s) Primary & Secondary winding material - Copper
Supplying and fixing , Stretching, Securing, Connecting & testing of Aluminium Conductor Steel Reinforced (ACSR) of size Zebra/Panther/Wolf for 33 KV yard complete incluiding taking out old unserviceable conductor complete all as directed.
M&L in replacement of damage single/double /triple tension disc insulators and hardware fitting and fixing in position including tighetning of bolts & nuts, complete after desmantling and lowering of damage conductor/disc insulator by taking tension of conductor on a separate arrangement including opening & provinding of jumpers of 33 KV tension towers complete all as specified and directed.
M&L in replacement of damage single/ double /triple disc suspension disc insulator by re-arranging with good/new disc insulators after taking the load of conductor on alternate arrangement including proper clamping etc. as per site requirement of 33 KV tower complete all as specified and directed.
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 33 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note-: (a) 33 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover will be laid in trenches for cable protection. If extra PCC cover and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
Material and labour for emergency maintenance work of 33 KV yard during breakdown by deploying skilled labourer and electricians at faulty site having Gang of minimum 6 persons and transportation including hydraulic machine and other tools and plant required at site for fault rectification. Note:- Contractor or his rep shall come to the site of breakdown within one hour of notification of breakdown . In case the rep or contractor do not come to the site of breakdown and start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contractor and will be deduct from his dues.
All as per Item No 9 here-in -before above but Gang of minimum 3 persons and without hydraulic machine.
S&F in replacement dead end clamps aluminium cast alloy for both terminals suitable for ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf of 33 KV yard /33 KV towers with GI nuts bolts complete all as specified and directed.
S&F in replacement 33 circuit breaker clamp aluminium cast alloy for both terminals suitable for ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard with GI nuts bolts complete all as specified and directed.
S&F in replacement CT clamps aluminium cast alloy for both terminals suitable for ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard with GI nuts bolts complete all as specified and directed.
S&F in replacement PT clamps aluminium cast alloy for both terminals suitable for ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard with GI nuts bolts complete all as specified and directed.
Supplying, laying, jointing testing and commissioning of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 400 sqmm 3 core with multistranded aluminum conductors, 33 KV (earth) grade, IS 7098 marked, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed.
Supplying, laying, jointing testing and commissioning of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 300 sqmm 3 core with multistranded aluminum conductors, 33 KV (earth) grade, IS 7098 marked, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed.
Supplying, laying, jointing testing and commissioning of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 300 sqmm 3 core with multistranded aluminum conductors, 11 KV (earth) grade, IS 7098 marked, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed.
Supplying, laying, jointing testing and commissioning of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 240 sqmm 3 core with multistranded aluminum conductors, 11 KV (earth) grade, IS 7098 marked, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed.
Supplying, laying, jointing testing and commissioning of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 185 sqmm 3 core with multistranded aluminum conductors, 11 KV (earth) grade, IS 7098 marked, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed.
Supplying, laying, jointing testing and commissioning of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 150 sqmm 3 core with multistranded aluminum conductors, 11 KV (earth) grade, IS 7098 marked, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed.
Supplying, laying, jointing testing and commissioning of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 120 sqmm 3 core with multistranded aluminum conductors, 11 KV (earth) grade, IS 7098 marked, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed.
Supplying, laying, jointing testing and commissioning of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1000 sqmm 1 core with multistranded aluminum conductors, 11 KV (earth) grade, IS 7098 marked, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed.
Supplying & laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size 450mm x 230mm x 50mm in trenches for protecting under ground cable as per IS (for 33 KV Cable) complete all as specified and directed.
All as per srl item No 23 here-in-before but using old reinforced precast concrete cable cove obtained under srl item No 62 here in after.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm.
All as per srl item No 25 here-in-before but using old un-reinforced precast concrete cable cover obtained under srl item No 62 here in after.
S&F in replacement Isolators clamps aluminium cast alloy for both terminals suitable for ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard with GI nuts bolts complete all as specified and directed
Supply and fix Cable jointing kit for 33 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
400 sqmm 3 core.
300 sqmm 3 core.
Supply and fix Cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
400 sqmm 3 core.
300 sqmm 3 core.
Supplying and Fixing in replacement, Post insulator with hardware fittings, 33 KV Grade, for isolator complete all as specified and directed.
Supplying and fixing in replacement, Disc insulators with hardware fittings, 33 KV Grade for 33 KV yard complete all as specified and directed.
S&F in replacement of pin insulator with hardware fittings 33 KV grade complete all as specified and directed
M&L for replacement of aluminium jumper made of ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf conductor of 33 KV yard complete all as specified as directed .
Material & labour for cleaning of the bay/yard (82.5 RM x 26.5 RM) manually without damaging any equipments, cable or parts of the 33 KV Grid bays, removing of dusts/grass/hurbs etc all as specified and directed.
Material and labour for sprading of stone aggregate of nominal size not more than 40mm from the bay/yard manually without damaging any equipments, cable or parts of the 33 KV Grid bays, spreading & levelling of finished gravel uniformaly in layers n. exc. 15 cm thick watered and rammed to true surface all as specified and directed.
M & L for cutting and removing grass, vegetation bushes etc from inside boundary wall and outsite boundary wall of 33/11 KV Sub Stn, around 33 KV towers and removing all rubbish to a distance not exceeding 50 m as directed.
M&L for Servicing & Repairs to Air-break switch (isolator) off load, rotating type, 33 KV, 800 Amps to 1250 Amps capacity, with proper alignment of isolator rotating blades, with fixed contact jaws, arcing horns, applying petrolium jelly to moving mechanism, cleaning and lubricating to isolator gear box assembly, tightening all nuts, bolts and clamps of jumpers etc, repairing to isolator gear box assembly and making in proper serviceable condition for smooth functioning, testing and commissioning on load complete all as specified and directed.
Supplying and fixing in repairs, male/moving contact/ rotating blade of HDE copper silver plated of Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity with all fixing nuts, bolts etc complete all as specified and directed.
Supplying and fixing in repairs, Fixed Contacts, made of HDE copper, silver plated, of Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity with all fixing nuts, bolts etc. complete all as specified and directed.
Supplying and fixing of terminal pad for Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity.
Supplying and fixing of arching horn for Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity.
Supply , installation, testing and commissioning in replacement of 33 KV air brake off load line isolator switch rotating type manually gear drive mechanism operated highest system voltage 36 KV rated current 1250 Amps triple pole with earthing device each pole consist of insulating pedestals 03 Nos on galvanized steel base as per BSS /IS incuding rotating blade of HDE copper and fixed contacts of same material , spring loaded arcing horns of adequate section to brake magnetizing current of transformer as directed with adequate 50mm dia GI operating pipe for operation from ground level and operating handle complete with both off and on positions complete all as specified and directed.
All as per item No 42 above but bus isolator without earthing device
Supplying ,fixing , testing of master trip relay , 50/24 Volt DC in control panel including wiring and taking down old UNSV relay complete all as specified and directed.
Supplying ,fixing , testing of Trip circuit supervision relay , 50/24 Volt DC in control panel including wiring and taking down old UNSV relay complete all as specified and directed.
Supplying ,fixing , testing of DC supervision relay, 50/24 Volt DC in control panel including wiring and taking down old UNSV relay complete all as specified and directed.
Supplying ,fixing , testing of SF 6 gas pressure supervision relay , 50/24 Volt DC in control panel including wiring and taking down old UNSV relay complete all as specified and directed.
Supplying and fixing in replacement PT fuse for 11 KV/110 V PT complete as directed at site.
S&F steel structure with ISMB/Channel/Angle iron/flat , clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint at 33 KV yard for fixing of isolator/CT/PT and for fixing of GO/DO etc complete as directed by Engr -In-Charge.
Supplying, installation, commissioning and testing in replacement of 11 KV Current Transformer (CT`s), indoor type, epoxy cast bar Primary type having ratio 1200/600/5-5-5 Amps , core -1, Class 10 P20 , 15 VA for protection , Core 2 Class 0.5 , 15 VA for metering, core -3 for differential protection , Short circuit time rating 18.4 kA for 3 Sec including associated wiring including taking down old UNSV CTs complete all as specified and directed.
Supplying, installation, commissioning and testing in replacement of 11 KV Current Transformer (CT`s), indoor type, epoxy cast bar Primary type having ratio 800/400/5-5-5 Amps , core -1, Class 10 P20 , 15 VA for protection , Core 2 Class 0.5 , 15 VA for metering including associated wiring including taking down old UNSV CTs complete all as specified and directed.
Material & labour for repair /servicing of RTCC panel of OLTC control panel of 33KV/11KV Power transformers of capacities 20MVA including repair /replacement to control wiring, repair to operation of OLTC from RTCC and checking of following and testing complete all as specified and directed :- (a) Digital Winding temp meter. (b) Digital oil temp meter. (c) Degital remote tap position indicator. (d) Indicator lamps. (e) Space Heater. (f) Fan auto working switch. (g) Analog to digital convertor and other spares required for displaying winding and oil temp.
All as per item ser No 52 here-in-before but 33KV/11KV Power transformers of capacities 16MVA
All as per item ser No 52 here-in-before but 33KV/11KV Power transformers of capacities 20 MVA
Supply only transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in transformer or for topping up as required and directed.
Material & Labour for Cable jointing kit for 11KV (earh) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size:-
120 Sqmm to 185 Sqmm
240 Sqmm to 300 Sqmm
Material & Labour for Cable jointing kit for 11KV (earh) grade cable for oudoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size:-
120 Sqmm to 185 Sqmm
240 Sqmm to 300 Sqmm
Material & Labour for Cable jointing kit for 11KV (earh) grade cable for straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size:-
120 Sqmm to 185 Sqmm
240 Sqmm to 400 Sqmm
Supply and fixing in replacement of ACB 4 Pole 800 Amps,50 KA 415 Volt, Horizontal , Mannual draw out type motorized, front operated with mircroprocessor based LCD protection release and adjustable over current and earth fault protection complete all as specified and directed.
Supply and fixing in replacement of ACB 4 Pole , 1250 Amps,50 KA 415 Volt, Horizontal draw out type motorized, front operated with mircroprocessor based LCD protection release and adjustable over current and earth fault protection.
Supply and fixing in replacement of ACB 4 Pole , 1600 Amps,50 KA 415 Volt, Horizontal draw out type motorized, front operated with mircroprocessor based LCD protection release and adjustable over current and earth fault protection.
Excavation in trenches not exceeding 1.5m wide & not exceeding 1.5m in depth and n.exc 10 sqm on plan for foundations , laying of LT under ground cables/ GI pipes and steel tubular poles etc. and getting out as in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm deep as in soil complete all as specified and directed.
Removal of excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above in starting point.
S & F common burnt bricks as mechanical protection of this cables using old size sub class ‘B’ bricks laid dry flat over the cable width equal to the length complete all as specified and directed.
Sand filling in trenches for cushioning of UG cables as layers of 8 cm before laying and 15 cm after laying of cables all as directed.
M&L for GI Tubes,of size 40 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
M&L for GI Tubes,of size 50 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
Supply, laying, testing and commissioning in replacement LT XLPE UG cable insulated, armoured heavy duty electric cable, 1100 volts grade with stranded aluminium conductor of 16 Sqmm 4 core complete including dismantling of old unserviceable cable.
Supply, laying, testing and commissioning in replacement LT XLPE UG cable insulated, armoured heavy duty electric cable, 1100 volts grade with stranded aluminium conductor of 25 Sqmm 4 core complete including dismantling of old unserviceable cable.
Supply & installing in replacement of steel tubular swaged poles type 410 SP-31 (9 mtr long) of apprx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting of flood light fittings , complete all as per manufacturer's instructions and as specified and as directed by E-in-charge. Make : National Tubing Co Kanpur/ or equivalent in Bajaj/CG NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of Channel /flat iron incl nut bolts,clamps etc , 1.5 mtr x 1.5 mtr long for fixing of LED Flood light fitings . The steel pole shall be painted by bituminious paint total lenth inside and up to planting depth outside.
Supply & fixing in replacement of 90 Watt LED flood light fittings made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed.
S&F in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps and 15 Amps fuse grip with base including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.
Supply, drawing, connecting & testing in replacement of 3 core, 2.5 Sqmm PVC insulated and PVC rounded sheathed, copper conductor (flexible) industrial cable 1100 Volts gradde conforming to IS-694 in steel tubular pole from KIOSK box to light fittings including providing suitable copper lugs all as specified and directed. Note : Steel tubular pole shall be measured and paid separetely.
S&F of time switches astro type in having longitude and latitude of Indian cities in memory 415 V three phase 20 Amp rating with 20 Amps, 415 Volts, three pole contactor fitted inside factory made 2mm thick steel enclosure duly powder coated paint complete all as specified and directed.
Supply and fix LED Flood light 200W including all fixing accessories completed all as per specified and directed. Make:- Surya Cat No. SLF FL 200W IP 65 Lumos or equivalent in Philips/GE
S&F 4 mm dia MS wire 150 mm x 100 mm mesh, made upto into mattress or cages appx 1.5 mtr height and fixed with flate iron/angle by welding in position and directed including complete all as specified and directed.Note:- MS angle /MS flate will be measured and paid seperately.
M & L for two coats of synthetic enamel paint of silver colour on steel surfaces over a coat of red oxide primer including preparation of surfaces complete all as specified.
Material and labour for cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) for sub floors, sub-bases, floors, foundation and paving etc complete all as specified and directed .
M&L for MS work of angles for post and struts of fencing around transformer plinth etc drilling holes, flate iron fillet for securing wire mess by welding to angle iron frame and framed work as in door/ gate of angle and wire mess. Door to be fixed by 03 Nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement complete all as specified including.
Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 50 to 100 mm bore and making good both ends all specified and directed
Supply and installation of Decorative pole as per Lustre Item No. LI-8440 with 36 watt led light fitting and standard fitment as per catalogue. The total height of the Decorative pole shall be 3870 mm nominal above the ground. The pole and base plate dia are 114mm and 250mm respectively.The pole is made out of mild steel tube with built in Service window at the bottom part of the pole to accommodate the 6 amp. SPMCB & 32 AMP. Heavy duty connector for mains connections. The MCB and connector shall be provided in the service window duly fitted on a suitable size heavy duty bakelite plate. The decorative arm and fixture is made of Aluminium. A toughened glass protector shall be fitted on the top of the fixture. The top reflector is made of Aluminium. The body of decorative pole should be machined & polished properly to give it a smooth surface. The decorative pole shall be duly pre-treated by Shot Blasting Process & painted in UV ray resistant P.U. top coating in approved finish. Decorative pole shall be installed at desired location including foundation of the pole by making cement concrete foundation of 1:2:3(1 cement: 3 course sand : 6 graded stone aggregate 40mm nominal size) with the help of anchor bolts and 38mm G.I sleeve as required.
Material and Labour for shifting of 33 KV Isolator from PT Bus isolator to line isolator and shifting of 33 KV Line Isolator to Bus PT Isolator carefully without damaging any equipment by disconnecting of Electrical Connections by taking proper Shut down Complete all as specified the isolator is deemed to be included in the quoted rate
S&F in replacement Feeder Protection relay suitable for 11 KB VCB.
S&F in replacement Electronic Trivector Meter ER 300 P, 3 Phase 4 wire, 3 x 63.5 V, Principal unit : Kwh/KVARH, Frequency: 50 Hz, Pulse rate 10000 Imp/Kwh, 10000 Imp/KVArh, Class : 0.5 s for Active 1.0 s for Reactive,
S&F in replacement Amp Meter Suitable for 11 Kv CTR 400/200/5 + 5 Amp as per Sample
S&F in replacement volt meter suitable for 33 KV VCB Panel, Auxilong supply 50 V DC as per sample.
S&F in replacement over current relay suitable for 11 Kv VCB control Panel.
Boring of hole under road/pavement/hard standing or any other situation by trenches Technology using ultra sounding Technique and necessary machine including HDPE pipe of 160mm dia suitable for 0.6 MPA working pressure complete all as directed.
Powerlite Engineers (BID ID -3341723)
Rajindera Enterprises (BID ID -3341620)
M/s JAIMAA ASSOCIATES (BID ID -3341602)
Vijay Electricals (BID ID -3341202)
DS CONSTRUCTION (BID ID -3341538)
mayur enterprises (BID ID -3336712)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .