Executive Engineer, DWS Maintenance Unit
Administrative Building, 245 M.L.D. Gangajal WTP Campus, Siddharth Vihar, Ghaziabad-201009
Internal Repair works of 2800mm dia. R.C.C. Pipeline using Chemicals at Select locations between Chainages 15.60 Km. to Teela Morh under 200Cusec Delhi Water Supply Maintenance Scheme for DJB
2026_UPJNM_1177088_1
874/NIVIDA/50 DATE 12/08/2026
Open Tender
Civil Works
Percentage
30 days
Ghaziabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
Executive Engineer, DWS Maintenance Unit
₹86,000
14 Aug 2026
14 Aug 2026
15 Sept 2026
14 Aug 2026
15 Sept 2026
14 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Internal Repair works of 2800mm dia. R.C.C. Pipeline using Chemicals at Select locations between Chainages 15.60 Km. to Teela Morh under Delhi Water Supply Maintenance Scheme for DJB. | - | - | - | - |
| - | Making lighting arrangement inside the RCC conduit by laying/stretching 4 Sq mm 2 core PVC insulated 1100V grade copper cable on top surface of rcc conduit, supply and fixing of multiple holder and 15 watt LED of Bajaj/Anchor/Havells or equivalent ISI mar | 500 | Rm. | 66.6 | ₹33,300 |
| - | Dewatering from RCC pipe line including hiring of pump set of . diesel operator etc. complete & suction pipe & delivery etc. complete. | 170 | Hour | 396.6 | ₹67,422 |
| - | Hiring of generator 25 KW at site for 8 hours including supply of diesel, Mobil oil, generator operator and cartage up to site. | 30 | Day | 5,988.25 | ₹1,79,647.5 |
| - | Cleaning of Joints including removing of rubber compression seal (baker rod), filling and all other loose materials from the expansion joint and clean the surface around the joint to make it free from loose particles,dirt,oil,grease etc and disposal of ma | 125 | Rm. | 319 | ₹39,875 |
| - | Drilling and fixing injection packers in RC members including, Drilling Holes: Drilling holes in structural members at the intervals as per recommendation of engineer in charge.Cleaning of holes: Clean the holes by air blower prior to fixing nozzles. Fixi | 270 | No. | 480 | ₹1,29,600 |
| - | Supply and apply single component, Polyurethane Injection foam based system for wet condition and temporary sealing, which cures to a dense flexible foam with a fine cellular structure. Minimum Product Requirements:
Viscosity cps 500-1300 at 23°C | 172 | Kg | 1,480 | ₹2,54,560 |
| - | Supply and apply 2 component, elastic, low viscous, solvent free, Polyurethane Injection resin based system for permanent sealing, that does not need the presence of water for hardening reaction
Product Requirements:
Viscosity of mixture < 100 mPa•s (at | 142 | kg | 1,790 | ₹2,54,180 |
| - | Repairing the edges of the joint (in case of weak concrete at the joint edge) and also configuring the joint width (in case of expansion joints with irregular width more than the width of the chosen Sikadur Combiflex Tape width) with epoxy repair mortar S | 125 | Rm. | 320 | ₹40,000 |
| - | Filling the joints with Rubber compression seal (baker rod) for expansion joints of size next higher to the joint gap and apply Polysulphide sealant in the expension joint up to a depth equal to not less than 1/2 the width of the joint including insert b | 125 | Rm. | 4,364 | ₹5,45,500 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.16 MB
TD874.pdf
Tender Documents • 2.06 MB
BOQ_2212090.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].