Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹53.9 L+₹1.1 L (2.16%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹54.3 L+₹1.5 L (2.92%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹56.9 L+₹4.2 L (7.89%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹57.5 L+₹4.7 L (8.96%)Rejected-Finance | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
3 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
PROVN OF EXTERNAL SERVICES AND ALLIED WORKS FOR INSTALLATION OF OXYGEN GENERATION PLANT AND PROVN OF MED GAS PIPE LINE SUPPLY SYSTEM AT KALIMPONG UNDER GE 867 EWS
2021_MES_473086_3
CA NO GE/867/TOKEN/41 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Kalimpong
Refer tender documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹96,000
Yes
26 Nov 2021
22 Oct 2021
4 Nov 2021
22 Oct 2021
3 Nov 2021
29 Oct 2021
22 Oct 2021 - 27 Oct 2021
60 days
Amount
Surface excavation not exceeding 30 Cm deep and averaging 15 Cm deep and getting out in soft/loose soil all as specified and directed by Engineer-in-charge.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, laying of pipe, cable etc., or for shafts, wells, cesspits, manholes, pier holes, etc., not exceeding 10 sqm on plan and getting out in soft/loose soil all as specified and directed by Engineer-in-charge.
M&L for Plain cement concrete 1:4:8 mix type D2 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete etc., all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete 1:2:4 mix, type B1 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams etc., all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
M&L for reinforced cement concrete 1:2:4 mix, type B1 (using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc., all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
M & L for old size fly ash bricks as in brick work straight or curved on plan exceeding 6m mean radious built in cement mortar 1:6 including demolition of existing brickwork complete all as specified and directed by Engineer-in-charge.
M&L for 15 mm thick cement mortar 1:2 as in damp proof cource to horizontal or vertical surfaces including necessary formwork, with and including integral waterprofing compound @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge.
Use and removal of steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete flat all as specified and directed by Engineer-in-Charge.
Use and removal of steel formwork to sides of square, rectangular or polygonal pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete 1:2:4 mix, type B1 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels exceeding 1.5 m span, bands etc., all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
Use and removal of steel formwork to sides and soffits of floor or roof beams, bands, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., for rough finished surfaces of concrete flat all as specified and directed by Engineer-in-Charge.
M&L for Mild steel deformed TMT bars 10mm dia and above as in reinforcement to concrete cut to length bent to shape required including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as directed by Engr-in-charge.
M&Lfor Mild steel deformed TMT bars 5mm dia and over up to and including 10 mm dia as in stirrups, spacers and binders , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified.
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:4 finished fair and even including waterproofing compound @ 3% by weight of cement as per manufacturer's instructions complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removing surplus excavated soil to a distance not exceeing 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
Filling under floors with approved earth obtained from excavation, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
M&L for Hardcore with Broken stone/boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified and directed by Engineer-in-charge.
M&L for 100 mm thick Plain Cement Concrete 1:4:8, type D2 (using 40mm graded stone aggregate) as in sub base and finishing even and rough to receive toping layer complete all as specified and directed by Engineer-in-charge.
S&F Mild steel works as in grills, framed guard bars, gates barred iron doors framed and hung as gates including pintal hinges stops, hand made sliding bolts and similar works conforming to Fe-290, Gde E-165 all as specified and directed.
M&L Mild steel work such as bands, straps, clamps and hold fasts etc. of Fe-290 Gde E-165 all as specified and directed.
M&L Mild steel works as in Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-charge.
M&L for 1.25mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed by Engineer-in-charge.
M&L 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 6 mm wide grooves to full depth at 2m to 3m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight complete all as specified and directed by Engineer-in-Charge.
S&F Mild steel bolts exc. 12mm dia and néxc. 20 mm dia purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and directed by Engr-in-charge.
S&F Fe 410-W (Gde-E- 250) quality-A rolled mild steel plates (plain or chequered), as in base plates etc., square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over one coat of primer complete all as specified and directed by Engineer-in-Charge. Make: INDOCEM/ SUPERSNOWCEM/ AQUACEM/ DURACEM
M&L 100 mm thick PCC 1:2:4, type B2 (using 40mm graded stone aggregate) in floors laid in alternative bays finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
S&F mild steel work in trusses, posts, purlins, rafters etc., including special shaped washer etc. complete using round or square or rectangular hollow sections of grade st 240 complete all as specified and directed by Engineer-in-Charge.
M&L Preparing new or previously un treated surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer all as specified and directed. Make: ASIAN/ SHALIMAR/ BERGER/JENSON&NICHOLSON/IEL
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for preparing new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed by Engineer-in-charge. Make: LOVELYCEM/ SURYACEM/ JANATHACEM / LUCKYCEM or equivalent make as approved by GE.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated (Trepezium or tiled pattern etc.) steel sheet 0.50 mm thick (with 0.45 mm BMT) of any colour having tensile strength of 550 Mpa (pitch of corrugation shall be 200mm to 250mm and crest shall be 28mm to 32mm) as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick (with 0.45 mm BMT) of any colour having tensile strength of 550 Mpa as in roof covering, eaves board, ridges, hips,valley gutters, drip and straight flashing cladding to wall etc, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. Make for Item No. 33&34: TATA BLUESLOPPE/ LLYODS /JMBS/ EVEREST INDUSTRIES LTD/CRIL/JSW Steel Ltd (JSW BISHWAS+) or equivalent as approved by GE.
M&L for Expanded metal, exceeding 4 kg per Sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and directed by Engineer-in-Charge.
M&L for Plain cement concrete 1:3:6 mix type C2 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete etc., all as specified and directed by Engineer-in-Charge.
S&F 20mm bore GI water tubing medium grade with all fittings and fixed to wall, floor, ceiling complete including short lengths all as specified and as directed by Engr-in-charge. Make: TATA/JINDAL/ZENITH
S&F 25mm bore GI water tubing medium grade with all fittings and fixed to wall, floor, ceiling complete including short lengths all as specified and as directed by Engr-in-charge. Make: TATA/JINDAL/ZENITH
Supply and fixing Rotational moulded polyethylene water storage tank cylindrical vertical double layered, 1000 ltrs capacity with closed top hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engineer-in-Charge. Make: SINTEX/ INFRA/ GP/ ROTEX/ ORIPLAST/ ASHISH/ POLYCON or equivalent ISI marked make as approved by GE.
S&F Symet ball valve 25 mm with high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipe and fixed min weight for 25 mm 455 gms, complete all as specified and directed by Engineer-in-Charge. Make: PRAYAG/POLYTUFF or equivalent as approved by GE.
S&F gun-metal, globe or gate valves of with iron wheel head, screwed both ends for iron pipe of 20 mm dia bore and fixed complete all as specified and directed by the Engineer-in-Charge.
All as per item No. 40 above but 25 mm dia bore. Make for Item No. 41&42:LEADER/NETA/ANCHOR/NMC/ DURGA/ZOLOTO or equivalent ISI marked make as approved by GE.
M & L Fe 290 Gde -E-165 mild steel angles or tees etc., as in staging of water tanks with web and flanges cut to shape, drilled and counter-sunk for screw, including bending and weilding angles as necessary , gusset plates, riveting etc, n exc 10 kg each brackets including painting with two coat of black bitiminious paint over a coat of Red Oxide primer complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:4 finished fair and even complete all as specified and directed by Engr-in-charge.
M&L for factory made precast cement block masonry with solid blocks made of Plain cement concrete 1:3:6 mix type C1 (using 20 mm graded stone aggregate) exceeding 10cm width and setting in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge. Make : Shankar Saw Mills/Sangam Prefeb Products or equivalnt as approved by GE.
M & L Plain cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping including necessary formwork, weathering, slightly rounded or chamfered andgles, finishing of exposed surfaces of concrete to even and smooth without using extra cement all as specified and directed by Engr-in-charge.
M&L for Cutting existing steel tubing of 25 to 50mm dia for alterations or additions (Each cut measured) complete all as specified and directed by Engr-in-Charge.
M&L for shifting of existing water staging tank complete with dismantling of existing tank to safe location and refixing complete staging to new location 10 mtr away from existing site complete all as directed by Engr-in-Charge.
M&L for taking up or down existing 15 mm dia bore water tubing and connections and cleaning & re-laying with and including new ISI marked pipe fittings, in new or old position in trenches, floors, etc., or fixed to wall complete all as specified and as directed by Engineer-in-Charge. NOTE: Excavation and earth work shall be measured and paid separately.
All as per item No. 49 above but 20 mm dia bore.
All as per item No. 49 above but 25 mm dia bore.
Supply, installation, testing and commissioning of 12 mm dia Copper Pipe : Copper tube of soiled drawn seamless deoxidized, non-arsenical, half hard, tempered and degreased as per BS EN 13348:2001 duly supported with manufacturer test certificates for physical properties and chemical composition complete all as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of 15 mm dia Copper Pipe : Copper tube of soiled drawn seamless deoxidized, non-arsenical, half hard, tempered and degreased as per BS EN 13348:2001 duly supported with manufacturer test certificates for physical properties and chemical composition complete all as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of 28 mm dia Copper Pipe : Copper tube of soiled drawn seamless deoxidized, non-arsenical, half hard, tempered and degreased as per BS EN 13348:2001 duly supported with manufacturer test certificates for physical properties and chemical composition complete all as directed by Engr-in-Charge.
Supply, installation, testing and comissioning of GAS TERMINAL UNIT : Terminal Units (Gas Outlets) with adaptors/probe for oxygen, compressed air and vacuum: Matching adaptors to the gas outlet mentioned above i.e. adaptor for oxygen, air and vacuum. The terminal units would have following features complete all as directed by Engr-in-charge. (a). It would be front insertion type, (b). Terminal unit would have mechanism with check valve, (c) Allow single hand operation. (d) On first insertion of probe the probe shall sit in a standby position. At the stage there shall be no gas flow, (e) Only on pressing the probe second time the gas supply would start, (f). They would close automatically when connected apparatus is removed, (g) For allowing on line maintenance the terminal unit would be equipped with a check valve for all positive pressure gases for closing gas supply whenever the outlet point is opened, (h). The outlet would be non interchangeable for specific gas and it would accept only correct medical gas adopter/Probe. (j). It would be color coded as per HTM 2022 (k) The design of this outlet would be compatible to installed vertical on valve horizontally on ICCU panel and area servicing unit and also vertical to fit in pendants. (l). It would only supply with correct probe/ adopter.
Supply, installation, testing and comissioning of ISOLATION VALVES ASSEMBLY: CE MARKED ISO 9001-2008. SPECIFICATION to control the pressure as well as for maintenance quarter turn open at 90-degree ball type valves would be provided. These valves would be of nickel-plated brass body having PTFE seat and inner outer seals. These valves would have stainless steel ball of specific ID clearance so that line pressure would not drop. For installation only PTFE gaskets would be used in between nuts and valve to prevent leakage. All the nuts for fixing the ball valve would be of brass with brass nozzles for easily brazing with copper tube. All ball valve assemblies would be on approachable height for easily operation and enclosed in powder quoted visible box complete all as directed by Engr-in-charge. TECHNICAL SPECIFICATIONS: (a). Leakage Clause : 1 (b). Temperature range : Ambient (c). Working Pressure : 7.5 bar maximum (d). Test pressure : 50 bar maximum (e). Standard : As per HTM 2022 (f) Size : 15mm to 28 mm
Supply and fix Bed Head Panel CE MARKED AS PER HTM 2022 : The modular medical bed head panel 1200 mm long: would be fabricated of aluminous die pressed 1.6 mm thick imported laminated sheet in such a way to provide 100% safe and efficient means to deliver all the gases as well as electrical to the patient/staff in intensive care conditions. To enclosed all piping, electrical wires, monitor wire ect it would be fitted continuously running on wall The design of modular BHU would consist of aluminum section to meet the requirement of HTM 2002, NFPA and other international standard.It would have separate duct for medical gases as well as electrical. There would be no sharp edges having smooth finish and without any visible screw etc.It would be have ability fix medical gas outlets, electrical sockets, It would also have color code around the specific gas outlet and a slide rail for focus lamp. It would be polyester powder coating finish on all external surfaces and would be fitted with wall with the help of 8mm fasters at specific It would be fixed in such a manner that it could be remove easily for servicing and repair. It would be long and continuous to fix for any distance complete all as directed by Engr-in-charge. Following fixed Accessories on Pendant: (a). Four 5 Amp. Sockets, (b) one I.V Hooks
Material and labour for BPC Flowmeter with humidifier bottle CE MARKED- would be BPC single type Pipeline Flow Meter unit duly fitted with the fine adjustment valve. It would be backpressure compensated to bear and 7 control the Oxygen Pressure approx. 60psi. Flow meter unit would be consisting of double wall rottameter has range of flow 0 to 13 ltrs. per minute with fine adjustment valve. The rotta meter and humidifier bottle would be made of clear, impact resistance polycarbonate (duly graduated). This unit would be have attachment to fit humidifier bottle of capacity 100 Ml. consist of clear, impact resistance polycarbonate jar. This would also have Reciprocating on top for flow meter/plastic cap having nozzles for outlet tubes and the inlet tube end would be multi function combination bubblier/ nebulizer to add the humidity and create an aerosol in Medical Gas min marks would be on jar. This unit would be supplied with PVC Clear green tube of 1.5mtrs. Long duly fitted with disposable Oxygen mask. complete all as directed by Engr-in-charge
M & L for making of hole on wall of any size and making good to disburbed surface and provn of pipe for passing of gass pipe from wall all as specified and directed by Engr-in-charge.
M&L for cross arms , bracings, supports, clamps and back plate fabricated from structural sections including nuts, bolts, and washer bending hot or cold , drilling holes for bolts of any size and painting with two coats of aluminum paint over one coat of red oxide primer including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for connection of new copper oxygen gas pipe line with the existing oxygen gas pipe line installed at existing manifold room with provn of new control valve complete with copper wilding, cutting, brazing complete all as specified and directed by Engineer-in-Charge.
Material and labour for 40 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection complete all as specified and directed by Egineer-in-Charge.
Material and labour for 25 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection complete all as specified and directed by Egineer-in-Charge. Make for iItem No. 63 & 64: TATA/ZENITH/JINDAL
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit, medium grade of suitable size with all necessary fittings, concealed in walls/ceilings etc., including 1.5 Sq mm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and including modular type terminal boxes with inner and outer cover concealed type for mounting fittings like modular switch, socket, fan regulator etc., for one light /fan point controlled by one switch/one bell / buzzer point controlled by one bell push/one 3 / 5 -pin switch socket outlet 5 amps on independent board including testing on completion complete all as specified and directed by Engineer-in-Charge.
All as per item No. 65 above but for One 3/5 pin switch socket outlet 5 amps on same board along with other switches complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 2.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit, medium grade of suitable size with all necessary fittings, concealed in walls/ceilings etc., including 2.5 Sqmm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and including modular type terminal boxes with inner and outer cover concealed type for mounting fittings like modular switch, socket, fan regulator etc., for one 5 / 6 -pin switch socket outlet 15 amps on independent board including testing on completion complete all as specified and directed by Engineer-in-Charge. Make for Item No. 65 to 67 Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Conduit: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
Supply and fixing modular switch one way 6 Amps, 1 module complete all as directed by Engr-in-charge.
Supply and fixing modular switch one way 16 Amps, 1 module complete all as directed by Engr-in-charge.
Supply & fixing modular socket, 6A-2/3 pin combined 2 module complete all as directed by Engr-in-charge.
Supply and fixing modular socket 6/16A, 6 pin, 2 module complete all as directed by Engr-in-charge. Make for Item No 68 to 71: - MK/ANCHOR ROMA/CRABTREE/ NORTH WEST/LEGRAND/HAVELLS
S&F lamp holder, PVC/Polycarbonate insulated body with back plate for batten fittings complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose 3 terminal PVC/Polycarnonate, isolated body complete all as specified and as directed by Engineer-in-Charge. Make for Item No.72&73: (i) Anchor (ii) Plaza, (iii) Havells (Crabtree) (iv) ABB (v) Shalabh
S&F 9 W retro fit B-22 LED lamp complete all as specified and as directed by Engineer-in-Charge. Make: Havells Cat No. LMLDERHEML 8X009 or equivalent in Philips/Crompton
S&F Energy efficient LED Tube light fitting, 4', 1x18 watt, with LED tube rod 18 Watt with bipin holders, connector block etc., complete with all accessories internally prewired and including connecting up with three core pvc sheathed flexible copper conductor cable of size 0.5 sqmm and 2 Nos PVC mounting blocks complete all as specified and as directed by Engineer-in-Charge. Make: Philips Model Batten TMC 501, TMC 501P 1xT-LED 22 W P3241 Tube rod MAS LED tube 18W 1800lm 865 T8 or equivalent in Crompton/Havells.
Supply, Fixing, Testing & Commsioning of IP66 & IK09 integral LED Bulk Head luminaire with housing made of Pressure Die Cast alumunium & Optical cover made of Opal Polycarbonate for glare free lighting . System Lumen Output of minimum 600 lumens. Power Consumption should not exceed 10W (Including Driver Loss). For Glare free lighting luminaire should be with Opal diffused Polycarbonate, Color temperature 6500 K, CRI >80, Housing - High pressure die cast aluminum, Mounting - Surface, THD < 20%, PF >0.9, Operating voltage range 120V-277V AC. Submission of LM80-08 for LED source & LM79-08 for Luminaire from third NABL Accredited Lab / UL mandatory including connecting up with 3.0 core, 0.5 sqmm copper conductor sheathed complete all as specified and as directed by Engineer-in-Charge. MAKE: Philips, Cat part No. "WT 202W LED 6S CW PSU S2 PC", or equivalent in Crompton /Havells
S&F sheet metal enclosure DB SPN 8 way 240 V with 200 Amp rated bus bar, powder coated, double door complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SPN 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SP 6 to 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 77 to 79: Legrand/Siemens/Schindler
M&L for sub main wiring complete with 2 runs of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through and including non metalic rigid PVC casing & caping of 25mm size fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor as earth continuity conductor and connecting to earth dolly complete all as directed by Engr-in-charge. Note: 2 runs of 4 Sqmm and one run of 4 Sqmm and one run of Casing&Caping shall be measured as one unit length. Make Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Casing&Caping: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
Supply install, testing and commissioning of automatic mains failure (AMF) silent Diesel Engine driven Generating set 415 volts, 62.5 KVA, three phase, 0.8 power factor, 50 Hz,1500 RPM, self excited, self regulated, AC generator installed including acoustic enclosure suitable for ambient condition at Kalimpong (WB) and confirming to condition under IS 10002/13364 Part-I 1992, BS 5514/5000 with following:-. Notes :- (i) The capacity of generator set shall be net after all due derating factors as per relevant IS/BS standard design. (ii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test. (iii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in particular specifications in presence of rep of accepting officer, all testing arrangement/equipment and deisel shall be made available by contractor for tests. (iv) The quoted rate shall be deemed to be inclusive of AMF inbuilt panel of suitable rating which will start the DG set during main failure and stop the DG set when main supply restores. (v) The contractor shall arrange for artificial load for testing for final testing of DG set at site and the cost is deemed to be including in the quoted rate. (vi) The quoted rate shall be deemed to be inclusive of necessary platform as per manufacturer's insstructions.
A. ALTERNATOR Standard desing alternator rated at 62.5 KVA/nearest higher available capacity at 0.8 (lag) power factor AC, three phase, 4 wire, 415 volts, 50 Hz, 1500 RPM, self excited, self regulated , screen protected, drip proof , bushless design with winding in pole faces, insulating class ‘H’ and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 5000, IS 13364 Part-I (1992) and shall be in position to generate supply with frequency regulation with within + 1% tolerance. The alternator shall be suitable for tropical climate and shall generally confirm to BS 2613/5000, IS-4722. (i) Insulation Class ‘H’. (ii) Temperature rise Class ‘H’. (iii) Excitation : Self-excited. (iv) Regulation performance : The voltage is kept constant with + 1% manual voltage adjustment within + 5%. (v) Frequency regulation + 1%.
B. DIESEL ENGINE :- Adequate capacity of diesel engine water cooled to drive independently above alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall as under :- (i) Fly wheel with housing. (ii) Cooling system – Moulded radiator with fan and belts. (iii) Cooling water pump : Centrifugal type belt driven. (iv) Exhaust System : Exhaust system complete with exhaust piping of suitable dia with MS pipe medium grade upto and outside the building, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall/enclosure : Turbo charger type Exhaust manifold Silencer, Residential type Bellows (v) Fuel system : Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electronic operated/(as recommended by OEM) for 1% speed/frequency regulation Fuel filter Fuel hoses (vi) Lub oil system :- Lubricating oil filter Lubrication oil pump
(vii) Air intake system :- Air intake manifold Air cleaner dry type (viii) Governer electronic (ix) Starting system- Electric self starter with and including battery charging alternator. (x) Batteries of capacity 12 V, 150 AH -01 No. Complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and directed. Starter gear ring Start and stop push button Ignition key/Switch Handling and operation : Salient features of accessories shall be as under :- Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel , lub oil and by pass. Governer electronic controlled direct fuel injection system Fly wheel and fly wheel. (xi) Generator Mounting Panel – Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start/stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/ coolent temperature indicator, Battery volt display. (xii) Safety controls :- Engine low lube oil pressure high water temperature and over speeding of engine.
(xiii) Coupling arrangements – Flexible coupling, fly wheel to suit flexible coupling. (xiv) Base Frame ;- Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes. (xv) Fuel tank :- Daily service fuel tank made out of 3 mm thick (10 SWG) HR Sheet top and bottom with calibrated level indication arrangement, stop cock, drain plug, complete on a common base inside in the acoustic enclosure. (xvi) MS pipe line to and from the fuel tank to the DG set.
(C) Acoustic Enclosure : Manufactured by OEM suitable for 62.5 KVA DG Set. (i) NAL approved as per CPCB. (ii) It should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board. (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Fuel tank should be inside the enclosure. (v) Construction Details/specification are as follows :- (a) Outer body : CRCA Sheet of 1.6 mm thick (b) Doors: CRCA sheet of 1.6 mm thick. (c) Sound insulation : 100 mm thick rock wool (minimum density 64 Kg/Cum)/fire resistance foam as per OEM/as per standard manufacturing to achieve desired decibel level. (vi) The acoustic should be composite in construction and fully assembled integral unit. (vii) The DG Set should be provided with external emergency stop push button. (viii) The enclosure should be suitably illuminated by CFL/FTL lamp fittings. (ix) The noise level should be 75 dB at 1 m under free field conditions. (x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The base frame should be painted with epoxy based black shade. Make of Engine: Kirloskar Oil/Cummins/Greaves/Mahindra Make of Alternator:- Kirloskar Green/Mahindra/Greaves/Cummins
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 Sqmm 3 core and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge. Note:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. Make of cable shall be CCI / Gloster / ICC / Unistar / NICCO / Asian (RPG) / Havells / Polycab/PRG/Universal/Plaza/Crystal cables/Terracom/ Rallison/Mescab/Jeypore/KEI
Supply and fix cable jointing kit for 11KV grade cable for outdoor termination heat shrink type with jointing material and accessories suitable for 3 core XLPE armoured Al conductor of size 95 Sqmm complete all as specified and directed by Engineer-in-charge. Make: RAYCHEM/ 3M / M-SEAL
Earhing complete with galvanized steel earth plate electrode 600X600X6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to GI earth strip of size 32x6mm, by means of galvanized iron or steel bolts, nuts, check nuts and washers, and conneced to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore, wire mesh charcoal or coke and common salt in alternate layers, of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia reinforced bar 15 cm C/C and earth lead handle protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc.50m and necessary testing complete all as shown on electrical plate No.3 of MES SSR Part I complete including taking out existing earthing all as specified and as directed by Engineer-in-charge. NOTE: Rate quoted shall be deemed to include for GI earth strip upto 7.5m.
Material and labour for 80 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection complete all as specified and directed by Egineer-in-Charge.
Material and labour for 50 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection complete all as specified and directed by Egineer-in-Charge. Make for iItem No. 85 & 86: TATA/ZENITH/JINDAL
Supply and spreading of dry sand in trenches for cable coushioning and punned down complete all as specified and directed by Engineer-in-Charge. Note:- Punned thickness only shall be measured for payment purpose.
Supply and laying unreinforced precast concrete cable cover, class LV, type 2, flat, size 300mm x 180mm x 40mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-charge.
Motorized Auguring/driling in road at 75 cm depth of dia sutable for laying of 40/50/80/mm dia GI tubing pipe complete all as directed by Engr -in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge. Note for Item No. 90 & 91:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. Make of cable shall be CCI / Gloster / ICC / Unistar / NICCO / Asian (RPG) / Havells / Polycab/PRG/Universal/Plaza/Crystal cables/Terracom/ Rallison/Mescab/Jeypore/KEI
Supply, install, testing and commissioning of LT Panel board, CPRI approved, outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars duly insulated by insulation of RYB colour 300 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40X40X6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following complete all as specified and directed by Engineer-in-Charge. (A) INCOMING (a) MCCB 4 Pole 415 Volts 25 KA 200 Amp rating thermal magnetic release type (Icu=Ics=100%), overload adjustment-0.8 to 1 X In -01 No (b) Panel mounted multi function energy meter of accuracy CL-1.0 rating - 01 No (c) RYB LED indicating lamp panel mounting type (Set of three) - 01 No. Make:-Schneider Model no: EM 6400 cat no : 30002012 or Eqvallent in Legrand/Siemens. (B) OUTCOMING (a) MCCB 4 Pole 415 Volts 25 KA 100 Amp rating thermal magnetic release type -01 Nos (b) MCCB 4 Pole 415 Volts 36 KA 63 Amp rating thermal magnetic release type -01 Nos (c) MCCB 4 Pole 415 Volts 36 KA 40 Amp rating thermal magnetic release type -03 Nos (d) MCB TPN 32 A -01 Make:-Schneider/Legrand/Siemens
Material and Labour for fixing of existing serviceable Transformer 100 KVA by transporting carefully to MH sub station from MES Power house with the help of crane and vehicle complete fixing on platform, making all connection from 4 pole str complete all as required at site and directed by Engr-in-Charge. Note: (i) Tool, machinery and transportation required for carry out of dismantling work and shifting of Transformer to MES yard shall be arranged by contractor and rates for the same shall bd deemed to be included in quoted rate.
Supply, install, testing and commissioning of LT Panel board, CPRI approved, outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars duly insulated by insulation of RYB colour 300 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40X40X6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following complete all as specified and directed by Engineer-in-Charge. (A) INCOMING (a) MCCB 4 Pole 415 Volts 25 KA 200 Amp rating thermal magnetic release type (Icu=Ics=100%), overload adjustment-0.8 to 1 X In -01 No (b) Panel mounted multi function energy meter of accuracy CL-1.0 rating - 01 No (c) RYB LED indicating lamp panel mounting type (Set of three) - 01 No. Make:-Schneider Model No: EM 6400 cat No : 30002012 or Eqvallent in Legrand/Siemens. (B) OUTCOMING (a) MCCB 4 Pole 415 Volts 25 KA 200 Amp rating thermal magnetic release type -01 Nos (b) MCCB 4 Pole 415 Volts 36 KA 125 Amp rating thermal magnetic release type -01 Nos Make:-Schneider/Legrand/Siemens
SANJAY SAW MILL
MANOJ JINDAL
JAYSHREE CONCERN
MS MAYA PRAKASH GOEL AND SONS
RAMESH GURUNG
G K SUTHAR
HEM RAJ GURUNG
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .