Tender Value
₹1.6 Cr
EMD Value
₹3.1 L
Closing Date
21 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SIG/NORTH
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of "V/N" or "V" whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Format-6, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar nature of work approved by CSTE/Western Railway. Note :- Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Defination of Similar Work :- Any signaling work involving outdoor work and / or addition and /or alteration in existing Indoor signaling system. OR any CLS or RI or EI or TPWS or IBS or ABS or BPAC work involving indoor and/or outdoor. Similar work to include indoor if the tendered work involves addition and / or alteration in existing indoor signaling system and outdoor if the tendered work involves outdoor work. OR Any such work involving activities as given in the name of the tendered work.
11 conditions · 3 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be
(a)Sole Proprietorship Firm: (i)All documents in terms of Para 10 of the Tender Form (Second Sheet).
(b)HUF: (i)A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii)All other documents in terms of Para 10 of the Tender Form (Second Sheet).
(c)Partnership Firm: (i)All documents as mentioned in para18 of the Tender Form (Second Sheet).
(d)Company registered under Companies Act2013: (i)The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii)A copy of Certificate of Incorporation (iii)A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv)All other documents in terms Para 10 of the Tender Form (Second Sheet).
(e)LLP (Limited Liability Partnership): (i)A copy of LLP Agreement (ii)A copy of Certificate of Incorporation (iii)A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv)An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v)All other documents in terms of Para 10 of the Tender Form (Second Sheet).
(f)Registered Society & Registered Trust: (i)A copy of Certificate of Registration (ii)A copy of Memorandum of Association of Society/Trust Deed (iii)A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv)A copy of Rules & Regulations of the Society (v)All other documents in terms of Para 10 of the Tender Form (Second Sheet).
Information as per Para 16 of GCC Part (1)(Tender form second sheet AnnexI) related to Employment/Partnership Etc. Of Retired Railway Employees revised by Railway board's letter no. 2014/CE-I/CT/0/9/RET dt.22.01.2015 : Amendment in Para 17 (a) of tender form and clauses 59 (9) & 62 (1) (xv) to GCC regarding employment etc. Of retired government officers by railway contractors"
Certificate of Information regarding EMPLOYMENT/PARTNERSHIP etc. of Retired Railway Employees with the tender as per the attched performa.
Certificate of NO RELATIVE being an employee of Western Railway as per attached Performa
Signal and Telecom work in connection with earthwork of Construction of Important Bridge No. 313 Up & Dn line on new alignment including Earthwork, Track work and associated Civil Works (From Chainage Rly KM 188+200 to Rly KM 189 + 500) between Pardi station and Atul station in connection with increase of speed to 160 Kmph in Virar-Surat section of Mumbai Division Western Railway.
SG_216_2_113_WA_313~WR
SG_216_2_113_WA_313
Open
Works - General
6 Months
Mumbai, Maharashtra
₹0
₹3.1 L
20 Aug 2026
20 Aug 2026
7 Sept 2026
85 items across 2 schedules · ₹92,68,097.65 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Main Signal Post Tubular 140 mm Dia, 5.6 Mtr Length as per IRS: S-6/81 or Latest & RDSO Drg. No. SA-24625 (Advance). CI Base (As per IRS S- 10 & RDSO Drg. No. 2011/M With latest assembly).2. Pinnacle.3. Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder.4. Signal Front Staging Complete Assembly for CLS Unit.5.Signal back staging as per extent WR Practice. | Numbers 3.00 | — | 11,388.76 | 34,166.28 |
| 2 | Excavation and Casting of foundation for main signal post as per CSTE/6294 (WR) with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost. | Numbers 3.00 | — | 8,399.14 | 25,197.42 |
| 3 | Junction route indicator unit 2 way as per Drg. No. RDSO SA 23402 is suitable for LED Signal Lighting Units & as IRS: S-66/84 amndt-1 or latest. | Numbers 1.00 | — | 21,875.31 | 21,875.31 |
| 4 | Erection of CLS Post with base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any... The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. It also includes supply of padlock for signal units and cable termination box. X' arms to be provided by the contractor till the signals are introduced. The Item includes cutting of Signal post if required by Site In charge. 2/3/4 aspect signal unit mounted directly on signal post. | Numbers 2.00 | — | 2,468.67 | 4,937.34 |
| 5 | Erection of CLS Post with base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any... The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. It also includes supply of padlock for signal units and cable termination box. X' arms to be provided by the contractor till the signals are introduced. The Item includes cutting of Signal post if required by Site In charge. 2/3/4 aspect signal unit mounted on offset bracket with junction type route indicator 1/2/3 or multilamp lamp route indicators mounted on signal post. | Numbers 1.00 | — | 3,640.86 | 3,640.86 |
| 6 | A -sign/AG - Sign Unit with Brackets & Fixing accessories. | Numbers 3.00 | — | 2,626.12 | 7,878.36 |
| 7 | Calling ON Signal Unit with Brackets & Fixing accessories. Calling On Signal Unit shall conform to RDSO Drg no 24351(Adv.) Alt1 suitable to LED Signal Lighting Unit. | Numbers 1.00 | — | 3,297.76 | 3,297.76 |
| 8 | Offset brackets for Main Signal, made of tubular steel, outer diameter 140 mm, thickness of pipe 4.5 mm. horizontal length of pipe 545 mm & vertical length of pipe 324 mm with fixing arrangement on Main Signal post as per Drawing No SW/554/G/R. | Numbers 1.00 | — | 5,036.25 | 5,036.25 |
| 9 | Offset brackets for ShuntSignal, made of tubular steel,outer diameter 89 mm,thickness of pipe 4.5 mm.horizontal length of pipe 324mm & vertical length of pipe324 mm with fixingarrangement on Shunt Signalpost as per Drawing NoSW/354/I | Numbers 1.00 | — | 4,953 | 4,953 |
| 10 | Fixing of Calling-on Signal/A-Sign/AG-Sign unit on signal post. The item includes fixing ofCo- On signal /'A' sign/ 'AG'sign unit on signal post with bracket, hood etc. Item includes supply bracket & fixing materials etc. by the contactor. The item also includes termination of cables & wiring inside Co- On signal /'A' sign/'AG' sign unit as per standard practice. Note: This Item must be operated individually, Not to be operated in Installation/Erection of CLS. | Numbers 4.00 | — | 2,316.82 | 9,267.28 |
| 11 | Pad locks Godrej make, Hardened NavTal 7 lever, 65mm Dia with common key or similar product having same feature & technical data. | Numbers 4.00 | — | 181.09 | 724.36 |
| 12 | Fabrication and fixing of 'A' Marker (Drg No. CSTE/6180), 'AG' Marker (Drg No. CSTE/6181), 'P' Marker (Drg No. CSTE/6182), Arrow Marker (Drg No. CSTE/6183), 'G' Marker (Drg No. CSTE/6184), 'C' Marker (Drg No. CSTE/6185). Marker disk on signals as per standard practice All material required for this work shall be supplied by Contractor. | Numbers 1.00 | — | 1,249.72 | 1,249.72 |
| 13 | Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990) Base, Hood, and Cover, etc. as per Drg. No. SA- 23840, Signal Number Plate, suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item). | Numbers 1.00 | — | 4,804.61 | 4,804.61 |
| 14 | Excavation and Casting of foundation for Shunt Signal as per Drg. No. CSTE/6090 with Contractor's own materials including Cement and Anchor Bolts of Standard Size. The required scaffolding, Ferma etc. for Casting of foundation will have to be brought by the Contractor at his own cost. | Numbers 1.00 | — | 5,640.71 | 5,640.71 |
| 15 | Erection of Position Light Shunt signal with Base, Post, and Signal unit. Wiring & Fixing of Number Plate .The work shall be done as per instructions of Rly engineer at site. | Numbers 1.00 | — | 1,856.21 | 1,856.21 |
| 16 | Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost. Single Case as per Drg No SK 748 or CSTE/5074 or SSLocation | Numbers 15.00 | — | 7,890.44 | 1,18,356.6 |
| 17 | Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost. Half Case as per Drg No SK 747or CSTE/5074 or SSLocation. | Numbers 15.00 | — | 5,871.18 | 88,067.7 |
| 18 | Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. Single Case | Numbers 15.00 | — | 1,162.15 | 17,432.25 |
| 19 | Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. Half Case | Numbers 15.00 | — | 683.36 | 10,250.4 |
| 20 | Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. Full Case. | Numbers 100.00 | — | 139.04 | 13,904 |
| 21 | Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. Half Case. | Numbers 100.00 | — | 93.16 | 9,316 |
| 22 | Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). | cum 10.00 | — | 3,855.74 | 38,557.4 |
| 23 | Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor. | cum 10.00 | — | 2,105.87 | 21,058.7 |
| 24 | ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | Numbers 8550.00 | — | 66.46 | 5,68,233 |
| 25 | Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. | Numbers 8550.00 | — | 13.38 | 1,14,399 |
| 26 | IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x8 | Numbers 38.00 | — | 4,944.55 | 1,87,892.9 |
| 27 | Fabrication and fixing of SMC sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783-1/2. With latest alterations & as per instructions of Rly engineer at site. Single Case Note: SMC sheet will be taken in place of phenolic laminated sheet. | Numbers 15.00 | — | 2,470 | 37,050 |
| 28 | Fabrication and fixing of SMC sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783-1/2. With latest alterations & as per instructions of Rly engineer at site. Half Case Note: SMC sheet will be taken in place of phenolic laminated sheet. | Numbers 15.00 | — | 815.12 | 12,226.8 |
| 29 | Thermo shrink UniversalJointing kit for Quad Cable (forstraight joints) as per RDSOspec IRS/TC-77/2012 revision3 With latest Amd. | Numbers 16.00 | — | 2,361.23 | 37,779.68 |
| 30 | Transferring ofSignaling/Telecom cables fromexisting Location box to new Location box . The workinclude breaking/ Dismantlingof Existing foundation oflocations, excavating andremoving / segregating coils of 2C/6C/12C/19C/24C/30C/Quadcables which may be about 10mtrs. in length. These cablesare to be disconnected andremoved from the existinglocation one by one as per theinstruction and under thesupervision of Railway staffpresent at site. The cable isthen to be inserted andterminated in new locationbox. The item includes neatlydressing of cable, makingwiring tree etc.The materialrequired to dressing /lacing willbe arrange by contactor. Thework is required to be donesystematically and with dueprecaution during the block ordisconnection within the timethat may be allowed. Theexcavation work to be donecarefully without damaging thecable to avoid undue failure.(Termination charges will begiven separately). Note:Proportionate payment will bemade if cable of other length.One No unit = One cable of 10m length) | Numbers 100.00 | — | 371.26 | 37,126 |
| 31 | Tic-tac Piano type Switches , 5A (ISI mark of reputed make) | Numbers 30.00 | — | 33.37 | 1,001.1 |
| 32 | Lamp holder , two pin , Bakelite type for Apparatus Cases (ISI mark of reputed make) | Numbers 30.00 | — | 50.09 | 1,502.7 |
| 33 | Track feed battery chargers, 110V AC input, 2 to 6/10 V DC Output; as per Specn.No.IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery. | Numbers 6.00 | — | 3,516.09 | 21,096.54 |
| 34 | Adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv.) with latest amendments (with Phenolic molded base). | Numbers 6.00 | — | 942.29 | 5,653.74 |
| 35 | Choke Coil for Single Rail Track Circuit on 25 KV 50 Hz AC Electrified Section as per Spec No IRS S 65/1983 with latest amendments. | Numbers 6.00 | — | 1,801.62 | 10,809.72 |
| 36 | Track Lead Junction Boxes as per C.Rly Drg. No.RST 11509 made from fiber glass/SMC/FRP along with terminal blocks. | Numbers 28.00 | — | 1,025.56 | 28,715.68 |
| 37 | Charging of Lead Acid Batteries with contractors own battery grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of W.Rly &instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in- charge.2V 80AH | Numbers 18.00 | — | 423.12 | 7,616.16 |
| 38 | Installation of DC track circuits covering points zones also. The item includes provision of continuity bonds of seven strand PVC jacketed wire/ GI wire 8 SWG on rail joints after drilling bond-hole of 7.0/7.1/7.2mm Dia (double bond with sleeves and rail clips are to be provided at each rail joint), insertion of insulated block joint, fixing of Track lead Junction box on MS angle two numbers of size 40X40X5 mm 1200 mm length for track feed/ jumper / track relay ends of track CCTs (as per double TLJB arrangements) and also for fixing jumper cables as per insulation diagram WR Drg No. CSTE/6055 and standard practice, making rail connections through suitable insulated sleeves from Track lead Junction box at TF, jumper & TR end with seven strand PVC jacketed wire /GI wire 8 SWG, rail clips for fixing bond wire on the TLJB as per standard practice, termination of tail cables on bootleg terminals etc. TF/TR wiring shall be fixed on the suitable arrangement on PRC sleepers with the help of hooks. Hooks shall be provided on PRC sleepers with the help of suitable steel bracket. This item also includes fixing & supply of channel pins etc. The item also includes supply of MS angles/ trestles, GI wire 8 SWG / seven strand PVC jacketed wire, hooks, rail clips etc. | Set 6.00 | — | 7,280.28 | 43,681.68 |
| 39 | Fixing and wiring of DC track circuit equipments i.e. track feed charger, resistance, track relay, battery, PPTC fuses etc., in the Apparatus Case and battery box as per standard practice. Termination of tail cable on M 6 / Screw less terminals WAGO or FINOLEX or similar approved make terminals/ fuse blocks / HRC fuse. Item includes testing /commissioning of track circuit. Complete wiring material (including PPTC fuses) which are not covered in Schedule will be supplied by contractor. (Supply of Track feed battery charger, track feed battery, resistances & 'B' type choke & Track relays will be supplied by Railways / covered in Schedule separately). | Per Track 6.00 Circuit | — | 7,439.74 | 44,638.44 |
| 40 | Low maintenance Lead acid secondary cell 2V/80 AH (Track feed Battery), shelf mounting type conforming to IRS:S- 88/2004 or latest (uncharged). | Numbers 18.00 | — | 2,782.94 | 50,092.92 |
| 41 | Miniature, Plug in Type, M to C,DC Neutral ,Track relay, ACI, Style QTA2, 9 Ohm, 2F-1B contact,Code - FGHKX Spec : BRS :939-A & 966 (Appx-F2) & IRS : S-23, S-23,S-34 & 60. | Set 6.00 | — | 5,981.72 | 35,890.32 |
| 42 | G.I. wire 8 SWG (4mm Dia) suitable for track circuit rail bonding or as per instructions of Engineer In-charge. | Kg 5.00 | — | 65.72 | 328.6 |
| 43 | Drill bits 7.2 mm or as per instructions of Engineer In-charge. | Numbers 20.00 | — | 140.75 | 2,815 |
| 44 | Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm Dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M. | Numbers 100.00 | — | 6.18 | 618 |
| 45 | Fuse block 2 Amp for DC trackcircuit or as per instructions of Engineer In-charge. | Numbers 100.00 | — | 134.25 | 13,425 |
| 46 | Non-detrioting type fuse 2 Amp or as per instructions of Engineer In-charge. | Numbers 100.00 | — | 62.76 | 6,276 |
| 47 | Supply of PPTC fuses 2A for TF TR or as per instructions of Engineer In-charge. | Numbers 50.00 | — | 20.34 | 1,017 |
| 48 | Excavation of cable trench as per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m. | cum 1200.00 | — | 311.05 | 3,73,260 |
| 49 | Digging of cable trench 0.3 Mtr. Deep and 0.3 Mtr. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches. | cum 50.00 | — | 410.21 | 20,510.5 |
| 50 | Digging of trench 1.2 M deep from rail flange/ road level and, 0.3 Mtr to 0.6 Mtr wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No.CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed. | cum 50.00 | — | 278.75 | 13,937.5 |
| 51 | Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trucking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be daggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. | Running 60000.00 Metre | — | 9.86 | 5,91,600 |
| 52 | Half Round RCC pipes & collarsof 150 mm internal dia (1 no =1 meter long) along withcollars as per IS No.458/2003of NP type. Tenderer shallsubmit inspection/test reportbefore supply for priorapproval by Engineer incharge. | Numbers 4000.00 | — | 185.08 | 7,40,320 |
| 53 | Laying of half round RCC pipe after laying the cables in thetrenches. (Cable laying iscovered separately) | Running 4000.00 Metre | — | 25.1 | 1,00,400 |
| 54 | Double Walled Corrugated(DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No.RDSO/SPN/204/2011 or latestanti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size120 mm outer die,& 103.5mm inner dia. (Them anufacturers, suppliersmust produce valid IS license and should be certified under ISO9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1)Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3)Tees 4) Bend,5) End-cap(The total quantity of aboveitems isequal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Test Check by Consignee & Sample check by JAG officer. | Numbers 25.00 | — | 2,167.93 | 54,198.25 |
| 55 | Medium Class G.I. Pipes to IS: 1239 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes. | Metre 20.00 | — | 637.22 | 12,744.4 |
| 56 | Placing of DWC/RCC pipes along with collars in trenches at places of track and road crossings, platform cuttings etc. also for straight cable laying. (Cable laying is covered separately.) | Running 170.00 Metre | — | 31.46 | 5,348.2 |
| 57 | Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50mm and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker. | Numbers 133.00 | — | 491.14 | 65,321.62 |
| 58 | Termination of outdoor cables, main cables laid in location boxes, Cable termination rack etc. at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site. | Numbers 8550.00 | — | 2.58 | 22,059 |
| 59 | Removal of Rail (13 mtrs.) inthe way of cable route. In caseof panel (39 Mtrs. Each) will beconsider as three rails forpayment purpose. | Numbers 20.00 | — | 110.63 | 2,212.6 |
| 60 | Removal of PRC Sleeper in theway of cable route | Numbers 20.00 | — | 123.74 | 2,474.8 |
| 61 | Jointing of 4 / 6 quad /Signaling cable with Heat Shrinkable straight through Jointing Kit. All the material required for the work are to be arrange by contractor himself at his own cost except Thermo shrinkable Joint Kit | Numbers 16.00 | — | 1,378.34 | 22,053.44 |
| 62 | Laying and fixing of Medium class GI pipes 100 mm Dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm Dia hole, or at any other locations as decided by Site Engineer. The GI pipe is to be filled with chattered compound. It includes supply of all material required for fi Xing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The e laying and fi Xing to be done as per RDSO drawings No. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest. | Running 20.00 Metre | — | 186.36 | 3,727.2 |
| 63 | Supply & fixing of GI troughing & Channel on girder bridges for carrying cables. Fixing of channel with Girder to be done with hook/ 'J' bolts of suitable size to held the load of the troughing as per Drg. No. CSTE/3004 and CSTE/3006. This item also includes the filling one layer of Bitumen compound as per extant practice. Supply and fixing of GI channel of size 100 mm x 50 mm x 06 mm, 1.2 Mtr. Long | Numbers 1400.00 | — | 799.96 | 11,19,944 |
| 64 | Supply & fixing of GI troughing & Channel on girder bridges for carrying cables. Fixing of channel with Girder to be done with hook/ 'J' bolts of suitable size to held the load of the troughing as per Drg. No. CSTE/3004 and CSTE/3006. This item also includes the filling one layer of Bitumen compound as per extant practice. Supply and fixing of GI troughing of size 150mm x 200 mm x 2000mm. | Running 700.00 Metre | — | 1,089.88 | 7,62,916 |
| 65 | Supply of Modular Location Box as per WR CSTE Drg No. 6285 Modular Type SS 304 Full Location Box. It includes Angle frame Relay frame fixture , earthing Rod , Drawing Board , Lock etc. as per WR CSTE Drg No. 6285. | Numbers 15.00 | — | 74,672.44 | 11,20,086.6 |
| 66 | SS Location box is made of Spl Grade SS 304 of sizeas per drg. No.DRM/SG/945 (Half app.Case).Manufacturer's certificate in regard tograde of stainless steel and test report shall be submitted at the time ofsupply. Note:- (1)Enclosed should be made of 1.6mm & door made of 2mm thick SS304 sheet.(2)SS 20 mm (rod) X 100mm (height)male female hinges for moving doors moothly.(3)SS 16 mm Rod fix handle for both the door.(4)SS sheet stiffner (0.8 to 1 mm thickness) for strengthenthe door both side. (5) SShook (6 mmrod) to beprovided on both doorsfor keeping thedoor openposition. Stoppers to beprovided forboth doors.(6)E-type lockingarrangement (W11)forboth door and lifting hook(5X150 mm) 02 Nos(7)SS sheet 250 mm x 450mm for half locationboxprovision of any writingwork at front sidedooretc. (8) Provision ofswitch board forlocationlight fitted with one twopin holder, Onethree pinsocket (female) and twopiano typeswitches of 6Afor location boxes withinternalwiring 2.5 sq.mm flexible copper wires,Holders,socket andswitch should be of ISImark.(9)Indian Railwayproperty tag is providedon twoside with followingdetails, Sr. No, Manufacturingfirm name& year of Manufacturing.(10)Whiteenamel paintshall be provided inside location box.(11)SS angle frame 30 mm x 30mm x 5 mm isprovidedalong with location box.(12)Earth GIclamp 5 mmx 50 mm flat is providing to locationat two ends toconnection earth GI patti.(13)Allhardware used inlocation box for mounting arrangements shall be of SS (nuts,bolts, washerse tc). (14)Suitable location box Hylam fabrication toprovide the clear space of writing to 18 cm to 20cm. (15) Packing each location box to be shipped using wrapping plastic sheet around location box. | Numbers 15.00 | — | 54,163.2 | 8,12,448 |
| 67 | Maintenance Free Earth Electrode of length 3m,including supply of 3 bags of Earth enhancement material for earthling (10KGs/bag) for each electrode & other accessories as per Drg. No.SDO / RDSO/ E&B/001 and RDSO Spec No.RDSO / SPN/197/2008. This item includes thefollowing items: (a) Copper bonded steel earthelectrode of 3.0 meter long & 17.2 mm dia withCu- bonding thickness of min 250 micron - 1 no.(b) Earth-enhancing compound (10 Kg/Bag) - 3No. (c) Cu-strip 200 X 25 X 6 mm to terminateearth rod = 1no. (d) Cu-strip 300 X 25 X 6 mm(MEEB) = 1 no. (e) Cu-strip 150 X 25 X 6 mm(SEEB) = 1 no. (Inspection by RDSO) | Numbers 30.00 | — | 9,518.51 | 2,85,555.3 |
| 68 | Installation of Maintenance Free Earth Electrode for Maintenance Free Earth spec of RDSO/SPN/197/2008. | Numbers 30.00 | — | 1,553.34 | 46,600.2 |
| 69 | Dismantling / Releasing of existing SignalingGears. One Signalling gear will be all parts ofone signal (consisting of CLS unit, Signal postalong with base) or lever frame (5 levers set),or one point (consisting of all parts of amechanical point, point machine, groundconnections etc.) or one track circuits(consisting of battery box & other parts of DCTrack circuit / AFTC /DAC) or one Blockinstruments or One Lifting Barrier or OneLocation Box etc. .This includes the cost oftransportation of release materials to storedepot or as decided by consignee in charge. Thiswork to be done by contactors with his ownvehicle and labour. (Per unit means Per Gear). | Per Unit 20.00 | — | 904.2 | 18,084 |
| 70 | Dismantling of Concrete foundation /Demolishing RCC / CC / Stone work / CuttingTar / carpentering / CC Flooring / Precastconcrete slab / Brick work including leading thedebris inside Railway limit or outside Railwaylimit as directed by site in charge. This work tobe done by contactors with his own vehicle and labour. | cum 20.00 | — | 747.24 | 14,944.8 |
| 71 | Horizontal direction drilling/boring withoutdamage of surface road using Auger Machine.The bore shall be 150 mm Dia & shall be doneat the depth of minimum 1200 mm from theground level. The ground level shall beconsidered ignoring the bank height of the bankof the road. The length of the bore shall beminimum 4 Mtr long. The HDD with or withoutHDPE pipe as per direction of Engineer Incharge. Note: HDPE pipe supply is taken asseparate item. This item also includes cablelaying (HDD boring). | Running 600.00 Metre | — | 1,312.31 | 7,87,386 |
| 72 | Fixing of Electrical Point Machine on theextended sleepers at points as per std. practiceand as per RDSO Drg No. SA 91 51-52 or 9710or 9161 as per section of rails used. Itemincludes fixing switch extension bracket,providing insulation for switch extensionbracket, fixing ground connection, adjustingopening of the switches and adjusting the point machine with crank handle. The item alsoincludes : (i) Complete material for installationlike ground-connections, switch extensionbrackets, point insulation material, I pipes,wiring materials, various fixing nuts & boltsincluding castle nuts, spring washers (ii) Allsmithy & fitting works required at site forcomplete installation. (iii) Installation of gaugetie plate & providing insulation for gauge tieplate (Insulation in William Stretcher Bar will beProvide by Railways). (iv) Wiring inside the pointmachine, insertion and termination of tail cablein point machine and junction boxes / locationbox /cable hut as per extent practice on WR andthe instruction of Railway Engineer at site. (v)Supply and fixing of suitable size GI pipes withflange for taking cable into point machine. Note; The ground connections shall be suitable to thePoint Machines as specified by Engineer-in-charge and shall be suitable to the point lay outi.e. 60 Kg. / 52 Kg / 90R as per yard layout.Electrical Point Machine and M-6 / Screw lessterminals will be supplied by Railways / coveredin Schedule separately. | Numbers 2.00 | — | 24,887.17 | 49,774.34 |
| Schedule total | ₹87,69,261.25 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].