| Sl No | Description | Qty | Unit | AARNA Constructions L1 |
|---|---|---|---|---|
| 1.00Providing, fixing and installation of NGR in different types of Power Transformers and Tran Switch units of Damini UG mine and Bangwar UG mine of ABD sub-area of Sohagpur Area, SECL | ||||
| 1.01 | Part-A Providing and Fixing of NGR at LT side of Power Transformer (CS Steel Make 500KVA. 3.3KV/550V, Oil Cooled) of Damini UG mine -
Supply & Fixing of NGR and sensitive Earth fault relay with sensor unit including installation & other associated charges | 1 | Nos | 15,500 ₹15,500 |
| 1.02 | Supply and Fixing of Under voltage relay & Earth fault relay | 1 | Job | 16,000 ₹16,000 |
| 1.03 | Supply and Fixing of Test/reset push button | 1 | Job | 5,000 ₹5,000 |
| 1.04 | Complete overhauling & wiring of LT Chamber, cable entry box & HT switches | 1 | Job | 5,000 ₹5,000 |
| 1.05 | Testing, supervision and Labour charge | 1 | Job | 18,000 ₹18,000 |
| 2.01 | Part-B Providing and Fixing of NGR at LT side of Trans Switch Unit (315KVA, 3.3KV/550V, FLP, Air Cooled - 04 nos) installed at Damini UG mine -
Supply & Fixing of NGR and sensitive Earth fault relay, single phase preventor, short circuit relay etc. in secondary breaker of TSU | 4 | Nos | 38,000 ₹1.5 L |
| 2.02 | Supply and Fixing of Under voltage relay & Earth fault relay | 4 | Nos | 16,000 ₹64,000 |
| 2.03 | Supply and Fixing of Test/reset push button | 4 | Nos | 5,000 ₹20,000 |
| 2.04 | Complete overhauling & wiring of LT Chamber, cable entry box & HT switches | 4 | Nos | 5,000 ₹20,000 |
Tender Value
₹14.4 L
EMD Value
₹18,000
Closing Date
13 Aug 2025, 5:00 pmClosed
Staff Officer EnM SECL Sohagpur Area
Staff Officer EnM SECL Sohagpur Area Dhanpuri Distt Shahdol MP 9424141331
Providing fixing and installation of NGR in different types of Power Transformers and Tran Switch units of Damini UG mine and Bangwar UG mine of ABD sub area of Sohagpur Area SECL
2025_SECL_340167_1
SECL/SGP/EnM/eT/25-26/343 Dtd 24.07.2025
Open Tender
Miscellaneous Works
30 days
Bangwar UG and Damini UG mine
As per NIT and Tender documents
4 documents required · 4 mandatory
₹18,000
5 May 2026
25 Jul 2025
15 Aug 2025
25 Jul 2025
13 Aug 2025
26 Jul 2025
25 Jul 2025 - 2 Aug 2025
Amount
Providing, fixing and installation of NGR in different types of Power Transformers and Tran Switch units of Damini UG mine and Bangwar UG mine of ABD sub-area of Sohagpur Area, SECL
Part-A Providing and Fixing of NGR at LT side of Power Transformer (CS Steel Make 500KVA. 3.3KV/550V, Oil Cooled) of Damini UG mine - Supply & Fixing of NGR and sensitive Earth fault relay with sensor unit including installation & other associated charges
Supply and Fixing of Under voltage relay & Earth fault relay
Supply and Fixing of Test/reset push button
Complete overhauling & wiring of LT Chamber, cable entry box & HT switches
Testing, supervision and Labour charge
Part-B Providing and Fixing of NGR at LT side of Trans Switch Unit (315KVA, 3.3KV/550V, FLP, Air Cooled - 04 nos) installed at Damini UG mine - Supply & Fixing of NGR and sensitive Earth fault relay, single phase preventor, short circuit relay etc. in secondary breaker of TSU
Supply and Fixing of Under voltage relay & Earth fault relay
Supply and Fixing of Test/reset push button
Complete overhauling & wiring of LT Chamber, cable entry box & HT switches
Testing, supervision and Labour charge
Part-C Providing and Fixing of NGR at LT side of 03 nos. Power Transformer (315KVA. 3.3KV/550V; 250KVA, 3.3KV/440V; 1000KVA, 33KV/3.3KV) of Bangwar UG mine - Supply & Fixing of NGR and sensitive Earth fault relay with sensor unit including installation & other associated charges
Supply and Fixing of Under voltage relay & Earth fault relay
Supply and Fixing of Test/reset push button
Complete overhauling & wiring of LT Chamber, cable entry box & HT switches
Testing, supervision and Labour charge
Part-D Providing and Fixing of NGR at LT side of Trans Switch Unit (315KVA, 3.3KV/550V, FLP, Air Cooled - 08 nos) installed at Bangwar UG mine - Supply & Fixing of NGR and sensitive Earth fault relay, single phase preventor, short circuit relay etc. in secondary breaker of TSU
Supply and Fixing of Under voltage relay & Earth fault relay
Supply and Fixing of Test/reset push button
Complete overhauling & wiring of LT Chamber, cable entry box & HT switches
Testing, supervision and Labour charge
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.36 MB
Tendernotice_2.pdf
PDF • 0.57 MB
BOQ_352630.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid