Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹228.2 CrAdmitted-Finance UNIT NO 12 4 MERLIN ACROPOLLS 12TH FLOOR 1858 1 RAJDANGA MAIN ROAD KOLKATA 700107 WB | KOLKATA | WEST BENGAL | 700107 | ₹228.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹232.8 CrAdmitted-Finance | ₹232.8 Cr | L2 | Admitted-Finance |
| 3 | L3₹240.7 CrAdmitted-Finance D 90 OKHLA INDUSTRIAL AREA PHASE 1 NEW DELHI NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | ₹240.7 Cr | L3 | Admitted-Finance |
| 4 | L4₹241.5 CrAdmitted-Finance | ₹241.5 Cr | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S Sri Gopikrishna Infrastructure Pvt Ltd L2 | Lumino Industries Limited L1 | KEI Industries Limited L3 | KISHORE INFRASTRUCTURES PRIVATE LIMITED L4 |
|---|---|---|---|---|---|---|---|
| 1.00Item Description | |||||||
| 2.00 | 11 M long Steel Tubular poles with welded steel base plate 300x300x8mm of Designation 410 SP -56 as per IS 2713 amended upto date along with 75x40x5mm GI channel for earthing arrangement & Pole marking | 646 | Nos | 20,330 ₹2.5 Cr | 24,184 ₹2.1 Cr | 23,483.01 ₹2.2 Cr | 24,560.03 ₹2.2 Cr |
| 3.00 | 9 M long Steel Tubular poles with welded steel base plate 300x300x8mm of Designation 410 SP 33 as per IS 2713 amended upto date along with 75x40x5mm GI channel for earthing arrangement & Pole marking | 14,540 | Nos | 13,910 ₹30.4 Cr | 16,626.5 ₹32.6 Cr | 16,215.55 ₹33.5 Cr | 16,928.36 ₹34.9 Cr |
| 4.00 | 8 M long Steel Tubular poles with welded steel base plate 300x300x8mm of Designation 410 SP 15 as per IS 2713 amended upto date along with 75x40x5mm channel for earthing arrangement & pole marking | 5,272 | Nos | 10,486 ₹8.7 Cr | 12,092 ₹8.8 Cr | 11,948.3 ₹9.3 Cr | 12,431.72 ₹9.7 Cr |
| 5.00 | Pre-fabricated steel items (Galvanised) like V cross arm,Cantiliver cross arm wherever rquired , top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, guarding channels, back clamp, | 2,01,532 | Kgs | 85.6 ₹2.5 Cr | 120.92 ₹3.3 Cr | 111.97 ₹3.0 Cr | 127.99 ₹3.7 Cr |
| 6.00 | Transformer mounting structure etc made of GI Channels, GI angle, GI flats of given sizes for over head structures . | 2,63,400 | Kgs | 85.6 ₹3.3 Cr | 120.92 ₹4.3 Cr | 111.97 ₹3.9 Cr | 127.99 ₹4.5 Cr |
| 7.00 | ACSR Conductor (50 mm²) - Rabbit | 750.87 | Km | 41,516 ₹4.9 Cr | 58,880.48 ₹5.8 Cr | 57,640.7 ₹6.0 Cr | 61,174.63 ₹6.8 Cr |
| 8.00 | ACSR Conductor (100 mm²) - Dog | 1,224.26 | Km | 80,250 ₹14.1 Cr | 1,15,608.59 ₹18.1 Cr | 1,12,195.85 ₹18.1 Cr | 1,20,123.45 ₹20.7 Cr |
| 9.00 | 11kV Polymeric composite Pin Insulator with Pin 12kV, 5kN | 29,684 | Nos | 192.6 ₹90.4 L | 284.16 ₹1.1 Cr | 177.52 ₹71.4 L | 151.61 ₹70.5 L |
| 10.00 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN with fittings | 9,376 | Nos | 406.6 ₹56.1 L | 400.55 ₹48.8 L | 314.07 ₹39.1 L | 397.97 ₹57.8 L |
Tender Value
₹215.7 Cr
EMD Value
₹4.3 Cr
Closing Date
22 Sept 2022, 3:00 pmClosed
Chief Engineer Projects KPDCL
Chief Engineer Projects KPDCL House No. 9,10 Post Office Lane Hyderpora Srinagar Kashmir 190014
DEVELOPMENT OF DISTRIBUTION INFRASTRUCTURE AT ANANTNAG DISTRICT OF JAMMU AND KASHMIR UNDER REVAMPED REFORMS-BASED AND RESULTS-LINKED, DISTRIBUTION SECTOR SCHEME(RDSS)
2022_PDD_180351_1
CE/P/KPDCL/RDSS/ANT 02 of 2022-23
Open Tender
Electrical Works
730 days
District Anantnag
As per SBD
9 documents required · 9 mandatory
₹25,000
Accounts Officer Projects KPDCL.
₹4.3 Cr
Srinagar
11 Oct 2022
22 Jul 2022
24 Sept 2022
23 Jul 2022
22 Sept 2022
18 Aug 2022
24 Jul 2022 - 5 Aug 2022
6 Aug 2022
Amount
Item Description
11 M long Steel Tubular poles with welded steel base plate 300x300x8mm of Designation 410 SP -56 as per IS 2713 amended upto date along with 75x40x5mm GI channel for earthing arrangement & Pole marking
9 M long Steel Tubular poles with welded steel base plate 300x300x8mm of Designation 410 SP 33 as per IS 2713 amended upto date along with 75x40x5mm GI channel for earthing arrangement & Pole marking
8 M long Steel Tubular poles with welded steel base plate 300x300x8mm of Designation 410 SP 15 as per IS 2713 amended upto date along with 75x40x5mm channel for earthing arrangement & pole marking
Pre-fabricated steel items (Galvanised) like V cross arm,Cantiliver cross arm wherever rquired , top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, guarding channels, back clamp,
Transformer mounting structure etc made of GI Channels, GI angle, GI flats of given sizes for over head structures .
ACSR Conductor (50 mm²) - Rabbit
ACSR Conductor (100 mm²) - Dog
11kV Polymeric composite Pin Insulator with Pin 12kV, 5kN
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN with fittings
Galvanised Nuts, Bolts with Washers.
Anticlimbing devices as GI Barbed wire with Clamps (3.5 Mtr, 2.5mm Dia, (12 swg) galvinised Barbed wire for each pole wound over a length 1Mtr)
Danger plate(written in Urdu and English), with Clamps & Weather Proof as per IS 8709-1977)
Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Wire 8 swg complete job for Steel Tubular poles including Nuts and Bolts.
Red Oxide Paint
Aluminium Paint
Cement Bottoming 1:2:4 mix as per REC standards including muffing, form work and allied job 0.45 cum/pole for 8.0 mtr STP and 0.5 cum/Pole for 9.0 mtr and 11.0 mtr STP (To be quoted in erection only)
Aluminium Jointing Sleeves for 30 sqmm-100 sqmm ACSR Conductor
Galvanised Stay Set with 50x8mm stay clamp, guy insulator, anchor plate (200x 200 x 6 mm), nut-bolts,turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete with cement concrete as per standard drawings
PG Clamps suitable for 30sqmm-100sqmm ACSR Conductor
Wedge Connectors for ACSR Conductor for DTR only
Suspension/Tension Clamp with eye hook including GI Clamps for HT/LT AB Cable
Straight through cable jointing Kit for LT AB Cable
Piercing Connectors (16-120Sqmm)
35mm² (LT) AB Cable ( 3 x 35 + 1 x 16 + 1 x 35 mm²) XLPE
50 mm² (LT) AB Cable ( 3 x 50 + 1 x 16 + 1 x 35 mm²) XLPE
70mm² (LT) AB Cable ( 3 x 70 + 1 x 16 + 1 x 50 mm²) XLPE
120 mm² (LT) AB Cable ( 3 x 120 + 1 x 16 + 1 x 95 mm²) XLPE
120 mm² 11kV (HT) AB Cable (3x120 + 1x95 mm²) XLPE
Heat Shrinkable Outdoor Cable Termination Kit for 11KV ABC
Mid Span Straight Through Jointing Kit for 11 KV ABC
11/0.433 KV, 3 phase, 63 KVA Distribution Transformer with bimetallic terminal connectors, LV cable box with detachable Al gland plate, Energy Efficiency level 1 (Al. wound) as per IS-1180 including amendments 1,2,3 & 4.
11/0.433 KV, 3 phase, 100 KVA Distribution Transformer with bimetallic terminal connectors, LV cable box with detachable Al gland plate, Energy Efficiency level 1 (Al. wound) as per IS-1180 including amendments 1,2,3 & 4.
11/0.433 KV, 3 phase, 200 KVA Distribution Transformer with bimetallic terminal connectors, LV cable box with detachable Al gland plate, Energy Efficiency level 1 (Al. wound) as per IS-1180 including amendments 1,2,3 &4.
11kV, 200A, 25kA for 3sec, 3-ph, 3 Pole,9 Post Vertical Mounting type Gang Operated, AB Switch along with Support Insulators, Base Channel down Pipe, Arcing Horns etc. complete.
9KV, 10KA Lightening/Surge Arrester (sets of 3 Nos) for DT.(Station Type)
11 kV, 3-ph, 200 A Horn Gap fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long(set of 3) as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, bobbin Insulator 50mm with suitable strap clamp, GI nuts, bolts & washers.it shall also include Gi Wire for earthing of LTDB, LTCT and GO handle refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover with required treatment
LT Distribution Box with mounting clamps for 63 KVA DTR with Suitable MCCBs for incoming and outgoing Circuits with suitable rating including Glands of SS as per Technical Specification
LT Distribution Box with mounting clamps for 100 KVA DTR with Suitable MCCBs for incoming and outgoing Circuits with suitable rating including Glands of SS as per Technical Specification
LT Distribution Box with mounting clamps for 200 KVA DTR with Suitable MCCBs for incoming and outgoing Circuits with suitable rating including Glands of SS as per Technical Specification
Sundry Items Like Lugs (Cu/Al) ,Binding Tape, Cable Ties, glass Sleeve, Jumpers, ferules ,Glands etc per DT including LT Panel
95 mm² Single-Core Cable, 1.1kV Grade, XLPE Insulated, unarmoured Stranded Al Conductor FRLS type
185 mm² Single-Core Cable, 1.1kV Grade, XLPE Insulated , unarmoured Stranded Al Conductor FRLS type
70 mm² Single-Core Cable,1.1kV Grade, XLPE Insulated , unarmoured Stranded Al Conductor FRLS type
LT 3 Phase Distribution Box (Metallic) with Busbar for service connection including GI clamps ( Pole mounted)
4 core 35 sqmm,1.1kV ,XLPE Armoured Cable from AB Cable taping point through Piercing connector to MSDB
LT Single Phase Distribution Box (Metallic) with Busbar for service connection including GI clamps ( Pole mounted)
Single core 25 sq mm , 1.1kV XLPE Armoured Cable from AB Cable taping point through Piercing connector to MSDB
11kV Isolator ,3 pole 600 Amps with earth switch horizontal mounting type with all accessories.
Guard netting 6 SWG/8 SWG wire
Sign Board as per Technical specification(18 inch X 12 inch)
Dismantling of existing 11/0.433kV, 3 Phase Distribution Transformer of various capacities up to 250kVA including transportation to KPDCL stores (To be quoted in Erection only)
Dismantling of existing 11/0.433kV, 3 Phase Distribution Transformer of various capacities above 250kVA including transportation to KPDCL stores (To be quoted in Erection only)
Dismantling and all allied jobs including handling and re-erection for straightening of existing poles of any size including Cement Bottoming (To be quoted in Erection only)
Dismantling and all allied jobs of wooden poles and under sized PCC poles including transportation to KPDCL Stores or disposal to designated site. (To be quoted in Erection only)
Dismantling of existing conductor of various sizes including all accesories on HT/LT lines including transportation to KPDCL stores. (To be quoted in Erection only)
M/S Sri Gopikrishna Infrastructure Pvt Ltd
KEI Industries Limited
KISHORE INFRASTRUCTURES PRIVATE LIMITED
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.96 MB
SBSPART2B.pdf
Tender Documents • 11.98 MB
SBDPART1.pdf
Tender Documents • 1.60 MB
SBDPART3.pdf
Tender Documents • 1.83 MB
RDSSPART4.pdf
Tender Documents • 14.62 MB
BOQ_443555.xls
BOQ • 0.47 MB
SBDPART2A.pdf
Tender Documents • 2.49 MB
Anantnag_Activity_sheet.pdf
Additional Documents • 0.46 MB
Download all tender documents and submit your bid