Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹27.6 L+₹2.3 L (9.23%)Rejected-Finance | L2 | Rejected-Finance Higher Bid value. | |
| 3 | L3₹27.9 L+₹2.6 L (10.4%)Rejected-Finance | L3 | Rejected-Finance Higher Bid value. | |
| 4 | L4₹28.2 L+₹3.0 L (11.9%)Rejected-Finance | L4 | Rejected-Finance Higher Bid value. | |
| 5 | L5₹28.4 L+₹3.1 L (12.4%)Rejected-Finance | L5 | Rejected-Finance Higher Bid value. |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
30 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Gangtok
GE Gangtok New Mil Stn Gangtok, Sikkim PIN-737102
REPAIR MAINT TO EXTERNAL LT ELECTRIFICATION AT NEW CANTT UNDER GE GANGTOK
2023_MES_617729_1
8156/A/E8
Open Tender
Electrical and Maintenance Works
Works
336 days
GE Gangtok New Mil Stn Gangtok
As per tender documents.
8 documents required · 8 mandatory
₹500
GE Gangtok
₹50,000
Yes
20 Oct 2023
8 Sept 2023
2 Oct 2023
8 Sept 2023
30 Sept 2023
16 Sept 2023
Amount
Taking up/down existing defective cable of sizes 2/3/3.5/4 core 10 to 70 Sqmm from the trenches ducts/along walls / poles/ under roads inside sub station including relaying in same or different position / location complete all as specified and as directed.
All as per above item No 1 but 95 to 185 Sqmm complete all as specified and directed.
Supply and laying testing and commissioning in trenches or fixing on wall or passing through pipe or in cable ducts XLPE insulated PVC FRLS, screened, PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of following sizes including cable lugs, glands, insulation tape etc complete all as specified and as directed.
10 Sqmm 4 Core
16 Sqmm 2 Core
16 Sqmm 4 Core
25 Sqmm 4 Core
35 Sqmm 4 Core
50 Sqmm 3.5 Core
70 Sqmm 3.5 Core
95 Sqmm 3.5 Core
120 Sqmm 3.5 Core
150 Sqmm 3.5 Core
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of cable & pole foundations and getting out in soft/loosse soil complete all as specified and as directed.
Returning filling in soft/loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removal of surplus excavated material (soil) to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
M&L for cutting the existing road/PCC / drain for taking out / laying of underground cable including necessary earthwork excavation and making good to match with the exisitng surface complete al as specified and with PCC 1:3:6 type C1 by (using 20 mm graded stone aggregate) 100mm thick complete all as specified and directed. Note- (i)GI pipe shall be measured and paid separately. (ii) Any damages made/caused to the HT/LT cables, water supply pipelines, OFC cables etc during the excavation works shall be made good by the contr as per original and GE Cost of the same is deemed to be included to be included in the unit quoted rate.
M&L for 50mm dia bore galvanised iron light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and as directed. Make:- Tata/ Jindal/ Prakash Surya
M&L for 80mm dia bore galvanised iron light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and as directed. Make:- Tata/ Jindal/ Prakash Surya
Laying, jointing, testing and commissioning of serviceable cable obtained from taking out in same or new location or position i.e. trenches/on walls/ floord/roof/ceiling etc of size 2/3/3.5/4 core 16 to 70 Sqmm including necessary cable lugs, gland etc complete all as specified and as directed.
M&L for straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 10/16Sqmm x 4 core cables including testing complete all as specified and as directed. Make :- Densons/ 3M /Raychern
All as per above item No 11 but 25 to 50 Sqmm 3/3.5/4 core complete all as directed.
All as per above item No 11 but 70 to 150 Sqmm 3/3.5/4 core complete all as directed.
All as per above item No 11 but 185 to 300 Sqmm 3/3.5/4 core complete all as directed.
M&L for LT outdoor end termination Kit (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty cables with aluminium conductor including all jointing accessories for making joints for the cable of following sizes 3/3.5/4 core incluing testing complete all as specified and as directed. Make :- Densons/ 3M/ Raychern (a) 185Sqmm to 300 Sqmm
S&F in replacement MCCB of 50Hz, 415 V adjustable type including necessary cable lugs & wire etc complete all as specified and as directed of following sizes Make : Legrand/Seimens/ABBL/L&T/HPL/Havells
400 Amp, 4 Pole, 36 KA
250 Amp, 4 Pole, 36 KA
250 Amp, 3 Pole, 25 KA
200 Amp, 4 Pole, 25 KA
100 Amp, 4 Pole, 16 KA
63 Amp, 4 Pole, 16 KA
S&F in replacement Onload/Off load change over switch I-O-II Operation, manual type, with sheet steel enclosure or panel mounted as per site requirement including necessary cable lugs & wire etc complete all as specified and directed for following capacity:- Make :- Legrand/Seimens/ABB/L&T/Havells
160 Amps, 4 Pole
100 Amps, 4 Pole
63 Amps, 4 Pole
Supply and replace aluminium lugs suitable for LT UG XLPE aluminium conductor cable including nuts, bolts, washers and PVC tape complete all as specified and directed for following sizes
240 Sqmm LT UG XLPE aluminium condutor cable
185 Sqmm LT UG XLPE aluminium condutor cable
120 Sqmm LT UG XLPE aluminium condutor cable
95 Sqmm LT UG XLPE aluminium condutor cable
70 Sqmm LT UG XLPE aluminium condutor cable
50 Sqmm LT UG XLPE aluminium condutor cable
25 Sqmm LT UG XLPE aluminium condutor cable
300 Sqmm LT UG XLPE aluminium condutor cable
M & L for servicing of LT panels/Feeder piller box of any size by complete cleaning of panel and bus bar at chamber with CTC solution, and welding the door using arc welding and fixing of hinges/Locking Handles/latches and necessary nut, bolts, washers and made it completely functional for open/close and incl checking of incoming and out going cable connections, Re-fixing of existing Cables, ACBS & MCCBs, and repair to connected PCC foundation and frame works, rewiring of control and power wiring of LT panel/Feeder with suitable size of FRLS cable but not less than 1.5 sqmm, replaceing of various unserviciable ON/OFF switches, lugs/Gland/Base plate/indicating Lamp/CT Coil etc making the panel fully functional including numbering the LT panelfeeder box and marking on panels (incoming and locations of outgoing MCCBs), to the satisfaction of Engr-in-Charge complete all as specified and as directed
M&L for painting of LT panel by spraying two coats of epoxy based weather proof paint of ivory colour over a coat of red oxide primer after cleaning of rusty panel surface of both inside/ outside by emery paper and necesary preparation of old steel surface complete all as specified and as directed.
M & L for Earthing complete with galvanized earth plate electrode 600 x 600 x 6 mm buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 32x6mm dia means of nut, bolts and washers made out of galvanized iron mild steel and 40 mm dia Gl pipe "light grade" for protection of earth lead/Strip and connected to control board or main switch or as directed by Engineer -in-Charge including earthing pit in PCC (1:3:6) type C1 for chamber & Pre-cast RCC cover of size 380 x 380 x 40 mm with one handle made out of 8 mm dia round bar, 20 mm dia GI pipe light grade for watering funnels, wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete.
S&F LED Multifunctional meter with CTS Complete all as specified and directed Make:CAT No. WL4110100000 of L&T or its equivalent in Legrand/ ABB/ Siemens/ GE/ C&S Electric Ltd/ Schneider as approved by GE.
S&F Indication Lamp (LED type) Set of 3 Complete all as specified and directed by Engr in-Charge. Make L&T or its equivalent in Legrand/ ABB/ Siemens/ GE/ C&S Electric Ltd/ Schneider as approved by GE
Supply installation, testing and commissioning factory made LT feeder pillar box outdoor type platform mounted,CPRI appoved suitable for 415 volts,3 phase,4 wire,50 Hz AC supply system all as specified and directed having busbar insttaled on DMC/Epoxy insulators. The panel shall be sust and vermin proof,lp-65 cass protection and made 3.15mm CRCA sheet with double door shutter and locking arrangement,openable front & back both including power coated on both outer and inner surface of panel. TPN aluminium bus bar not less than 1.5 times the rated capacity of incommer MCCB including 50x50x6mm thick angle iron frame workupto height of 0.9 mtr above ground level (dult painted with synthetic enamel paint over a coat of red oxide primer onexposed surfaces) with and including following spares and including dismantling old unserviceable existing feeder pillar box all as specified and directed by Engineer-in-Charge. (a) MCCB 4 pole 25 KA 100 Amp-01 No(Incomer) (b) MCCB 4 pole,25 KA 63 Amp-03 Nos(Outgoing) (c) Phase indicating lamps(R-Y-B)-01 set (Multifunctioning meter with necessary CTS
Supply, installation testing and commissioning factory made LT feeder pillar box outdoor type platform mounted,CPRI appoved suitable for 415 volts,3 phase,4 wire.50 Hz AC supply system all as specified and directed having busbar insttaled on DMC/Epoxy insulators. The panel shall be sust and vermin proof,lp-65 cass protection and made 3.15mm CRCA sheet with double door shutter and locking arrangement,openable front & back both including power coated on both outer and inner surface of panel. TPN aluminium bus bar not less than 1.5 times the rated capacity of incommer MCCB including 50x50x6mm thick angle iron frame workupto height of 0.9 mtr above ground level (dult painted with synthetic enamel paint over a coat of red oxide primer onexposed surfaces) with and including following spares and including dismantling old unserviceable existing feeder pillar box all as specified and directed by Engineer-in-Charge. (a) MCCB 4 pole 25 KA 400 Amp-01 No(Incomer) (b) MCCB 4 pole,25 KA 160 Amp-02 Nos(Outgoing) (c) MCCB 4 pole,25 KA 100 Amp-01 Nos(Outgoing) (d) MCCB 4 pole,25 KA 63 Amp-02 Nos(Outgoing) (E) Phase indicating lamps(R-Y-B)-01 set (Multifunctioning meter with necessary CTs
Supply and fixing 1100 volts ghrade heavy duty duty 10 sqmm stranded cable PVC insulated aluminium conductor,served with inner sheathing of PVC and overall PVC sheathed in service connections supended by insulating hangers not more than 01 meter apart including 4 mm suspnsion wire one twin core cable flat/circulaor complete all as specified and directed.
Supply and fixing 1100 volts ghrade heavy duty duty 16 sqmm stranded cable PVC insulated aluminium conductor,served with inner sheathing of PVC and overall PVC sheathed in service connections supended by insulating hangers not more than 01 meter apart including 4 mm suspnsion wire one twin core cable flat/circulaor complete all as specified and directed.
Supply and laying of DWC HDPE pipe,ISI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket,bend,couplers etc confirming to IS 14930.part- complete with fitting cutting jointing etc of size 50 mm outer dia complete all as specified and directed by Engr-in-Charge
Supply and laying of DWC HDPE pipe, ISI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket.bend couplers etc confirming to IS 14930.part- complete with fitting cutting jointing etc of size 75 mm outer dia complete all as specified and directed by Engr-in-Charge
M&L for earthing complete in repairs with advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (zinc & alloy coated), ZINC coated (80-100) microns with pure Zinc (99.9%) & ALLOY COATING (200-250) microns. Earthing System confirming IS 3043. The outer and inner pipe should be 48.3mm & 26.4mm 2mtrs length, zinc coated with additional special Alloy coating 300mm on the topside for additional protection of the terminal. The annular space between the pipes being filled up with COMPACT FILL (CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity. The job includes digging the pits and refilling the same by BARONS electrodite OR conductolite back fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having ROHS certification from NABL accredited lab. The earth pit should be provided with a FRP OR EPCC earth pit cover for protection and safe guard of terminals. In areas where soil condition is bad, GOOD EARTH ie BLACK COTTON or MOISTUROUS NORMAL SOIL is to be arranged to fill the excavated pits by mixing the arranged soil with BFC 2 to 4 bags ELECTRODITE OR 2.4 BAGS CONDUCTILITE BFC FOR INSTALLATION OF EARTH. ELECTRODE. The electrode should be of galvnised (80-100 micron) along with earth lead as Galvanised steel strip of size 32 x 6mm, 7.5 m. including excavation earthwork etc connected to electrical eqpts/panels and testing on completion all as specified and directed by Engr-in-Charge.
Supply and fix in repairs MCB of 4 pole of 63 Amps 415 volt complete with connection testing and commissioning.
Supply and fix in repairs MCB of 2 pole of 63 Amps 240 volt complete with connection testing and commissioning.
S&F loop in loop junction box internal dimension 155X210X92mm made out of polycarbonate and locking amgement incl 6 Amps MCB-01 No, 20 Amps rated 4 way connectionfor 3 phase and neutral incoming/outgoing mouted in the box, fixing on steel, tubular poles including necessary clamps,suitable glands,lugs and GI nut and bolts including taking out old unserviceable junction box complete all as specifed and directed.
M/S ANIL KUMAR THAKUR
RABI BANIK
Phurba Wangdi Sherpa
KAMLESH ENTERPRISE
MS CHOWDHURY ENTERPRISE
BIJAY MITTAL
MAHENDRA KHAWAS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .