Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹23.4 L+₹2.3 L (11.1%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹27.2 L+₹6.2 L (29.3%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Rejected |
Tender Value
₹47.5 L
EMD Value
₹94,900
Closing Date
15 Mar 2023, 6:00 pmClosed
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
MAINT/ REPAIR TO INTERNAL ELECTRIC SUPPLY INCLUDING ATTENDING DAILY COMPLAINS OF SWITCH SOCKETS FITTINGS AND FIXTURE DBS MCBS AND ALLIED WORKS AT WAC SMQ SNCOS MESS, AIRMEN MESS ETC, REPAIR REPLACEMENT AND MAINTENANCE OF UNSERVICEABLE UG CA
2023_MES_581681_1
GE/SP/ TOKEN-80/2022-23
Open Tender
Civil Works
Item Rate
180 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹94,900
Yes
5 Apr 2023
17 Feb 2023
22 Mar 2023
17 Feb 2023
15 Mar 2023
3 Mar 2023
Amount
Taking down carefully copper/aluminium point wiring( light ,fan, socket or power) complete, fitting such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 1.5 sqmm single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20 mm including conduit fittings and accessories concealed in wall / ceiling wiring on ceiling /wall terminated in flush metal box alongwith outer cover plate for mounting modular/piano switch, socket and electronic regulator along with provn of earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS ISI marked copper conductor of size 1.5 sqmm all as specified and directed by Engr-in-Charge. For One light point/fan poit/bell point controlled by one switch one way.
All as per item No 2 above but for one 3 pin 5 amps socket outlet on indipendent board with other switchs.
All as per item No 2 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 2 above but with 2.5 Sq mm cable for Independent one 3 pin 15 Amps socket outlet In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
M&L for point wiring with 1.5sqmm PVC insulated unsheathed multi stranded copper conductor cable drawing in existing steel/PVC conduit with 1.5 Sq mm PVC insulated copper conductor cable for continuous earth wire connected to main earth dolly complete. One light point/fan point/bell point controlled by one switch complete all as specified and directed by Engineer in Charge.
All as per srl item 6 above but for one 5 pin 5 amps socket outlet on the independent board.
All as per item No 6 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 6 above but with 2.5 Sq mm PVC insulated stranded copper conductor cable for one 3 pin 15 Amps socket outlet. In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
S&F switch piano, flush type single pole, one way, 6 Amps, 240 volts all as specified and directed by Eng-in-charge.
S&F Socket outlet 2 in 1, 3 pin,6 A, 240 volts all as specified and directed by Eng-in-charge.
S&F switch piano, flush type single pole, one way, 16 Amps, 240 volts all as specified and directed by Eng-in-charge.
S&F socket 16 Amps, 2 in 1, flush type all as specified and directed by Eng-in-charge.
Supply & fix bell push, flush type, 5 Amps, 240 volts all as specified and directed by Eng-in-charge. .
S&F Fan Regulator step type 120 watt, 240 volt complete.
Supply and fixing ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed by Eng-in charge
Taking down the old white hylium sheet from the existing flash metal box and replacing new supper quality white hylium sheet of size 9" x 13" complete all as specified and as directed by Engineer-in-Charge.
All as per srl item 17 above but of size 8" x 5" complete all as specified and as directed by Engineer-in-Charge.
All as per srl item 17 above but of size 7" x 5" complete all as specified and as directed by Engineer-in-Charge.
All as per srl item 17 above but of size 5" x 5" complete all as specified and as directed by Engineer-in-Charge.
Taking down rusted sunkan metal box and fixing new metal box of 3 mm thick of size 8''x11'' with finishig of disturbed surfaced as directed by Engineer in charge.
Taking down rusted sunkan metal box and fixing new box of 3 mm thick of size 8''x5'' with finishig of disturbed surfaced as directed by Engineer in charge.
Taking down rusted sunkan metal box and fixing new box of 3 mm thick of size 7" x 5" with finishig of disturbed surfaced as directed by Engineer in charge.
Taking down rusted sunkan metal box and fixing new box of 3 mm thick of size 5" x 5" with finishig of disturbed surfaced as directed by Engineer in charge.
S&F in repair of sub main wiring with 2 single core 04 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in existing rigid non- metallic PVC/metallic conduit incl 4.0 Sq mm PVC insulated single core copper conductor cable for continuous earth wire.
S&F in repair of sub main wiring with 2 single core 06 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in existing rigid non metallic PVC conduit incl 6.0 Sq mm PVC insulated single core copper conductor cable for continuous earth wire.
M & L in repairs rigid non metalic PVC medium grade conduit including junction boxes, tee, bends, elbows, reducers bell mouth tube ends,fixing accessories such as couplers, lock Nuts, saddle pipe hook etc for 25 mm dia.ISI Marked.
Supply & fix in replacement of Casing capping double lock type supper quality size 20 mm width ISI marked with fixing accessories complete all as specified and directed by Engineer in Charge.
Taking down of LED/Tube light/CFL fitting of any type of make and removing material to store for keeping in safe costudy or for reuse or taking credit and making good distrub surface of walls,floor etc complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED lights fitting 1x 10W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fix in replacement lamp holder PVC/Poly Carbonate type suitable for LED Bulb with ISI mark complete all as specified and as directed by Eng-in-charge.
Taking down carefully ceiling fans of any size for repair/service/rewinding/greasing and refixing in its original position after necessary repair/rewinding/servicing/greasing etc including connecting up with flexible twin core cable 23/0.0076 from ceiling rose or connector to fan complete and to ensure that ceiling fan should be fix in position in all respect all as directed by Engineer in Charge.
M& L for minor repair/service and greasing of bearings, cleaning of dust on ceiling fans with blades and canopys and reconnecting the electrical conections and with regulators complete all as specified and as directed by Engineer-in-Charge. Note: All required Materials are deemed to be included in the unit rate quoted.
M & L for repair to Ceiling fan of of any size by replacing unserviceable ball bearing of suitable size including neccessary greasing complete all as specified and directed by Engineer-in-Charge.
M&L for Rewinding of ceiling fan of sweep 1200mm/1400 mm sweep of any make and model with super enameled copper winding wire of same size as per old winding wire and confirming to relevent IS including replacement of insulation material, varnishing, greasing and lubricating, ball baring, GM bushes and replacement of suitable capacity of condenser and testing complete all as specified and directed by Engineer in Charge.
S&F in replacement of fan capacitor with copper wire plastic body 2.5 mfd.
S&F in replacement of fan capacitor with copper wire plastic body 3.15 mfd.
S&F in replacement of rubber real for ceiling fan complete all as specified and directed by Engineer in Charge.
S&F in replacement of mild steel U clamps including 10 mm dia but, nuts, washers and split pin for ceiling fan complete all as specified and directed by Engineer in Charge.
S&F in replacement of mild steel fan hook made out of 12 mm dia mild steel round bar of suitable size as per existing hook as directed by Engineerin Charge.
S&F in replacement of upper louver conopy of ceiling fan of any sweep, make, modles & size as per existing complete as specified and directed by Engineer in Charge.
S&F in replacement of ceiling fan heady duty 1200 mm sweep including necessary fixing arrangement for proper fixing as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully Exhaust fans of any size for minor repair/service/rewinding/greasing and refixing in its original position after necessary repair/rewinding/servicing/greasing etc including connecting up with flexible twin core cable 23/0.0076 from ceiling rose or connector to fan complete and to ensure that ceiling fan should be fix in position in all respect all as directed by Engineer in Charge.
M& L for minor repair/service and greasing of bearings, cleaning of dust on exhaust fan fans with blades and reconnecting the electrical conections and with regulators complete all as specified and as directed by Engineer-in-Charge.
M & L for repair to exhaust fan/ of of any size ( 200 to 600 mm sweep) by replacing unserviceable ball bearing No 6201/6202/6203 including neccessary greasing complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of exhaust fan pvc of 200 mm sweep with super enamelled copper winding wire of same size as per old winding wire and confirming to IS including replacement of insulating material, warnishing, greasing lubricating, ball bearing, GM bushes and replacement of suitable capacity of condenser and testing complete all as specified and directed by Engineer in Charge.
All as per item No 47 above but size of exhaust fan metal 200/225/250 mm sweep complete all as directed by Engr-in-charge.
All as per item No 47 above but size of exhaust fan metal 300 mm sweep complete all as directed by Engr-in-charge.
All as per item No 47 above but size of exhaust fan 450 mm sweep complete all as directed by Engr-in-charge.
S&F in replacement of fan capacitor with copper wire plastic body 1.0 mfd suitable for exhaust fan
S&F in replacement of fan capacitor with copper wire plastic body 4.0 mfd suitable for exhaust fan
S&F in replacement of exhaust fan heavy duty plastic body 200 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of exhaust fan heavy duty metal body type 225/230 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
All as per item No 54 above but size of exhaust fan 250 mm sweep complete all as directed by Engr-in-charge.
All as per item No 54 above but size of exhaust fan 300 mm sweep complete all as directed by Engr-in-charge.
All as per item No 54 above but size of exhaust fan 450 mm sweep complete all as directed by Engr-in-charge.
S&F in replacement of wall mounting fan heady duty 450 mm sweep including necessary fixing arrangement for proper fixing on wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of exhaust fan louvers fan suitable for 225/230/250 mm sweep including necessary fixing arrangement for proper fixing on wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
All as per item No 59 above but size of exhaust fan 300 mm sweep complete all as directed by Engr-in-charge.
Cutting of existing surface/wall for making hole suitable for fixing of exaust fan of required size including 04 Nos hold fastner and making good the disturbed surface all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type regal gray horizontal typecomplete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCCB four Pole 125 Amps, 415 volt thermal release bearing cap 16 KA suitable for the MCB DB above comlete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement MCCB four Pole 100 Amps, 415 volt thermal release bearing cap 16 KA suitable for the MCB DB above comlete all as specified and as directed by Engineer-in-Charge.
S&F in replacement MCCB FP 16 to 63 Amps 16 KA, 440/415 volt 50 Hz all as specified ans directed by engineer in- charge.
S&F MCB in replacement TP 25 to 63 Amps 10 KA, 440 volt 50 Hz all as specified ans directed by engineer in- charge.
S&F MCB in replacement TP 100 Amps 16 KA 440 volt 50 Hz all as specified ans directed by engineer in- charge.
S&F in replacement MCB TP 125 Amps 16 KA 440 volt 50 Hz all as specified ans directed by engineer in- charge.
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, 240 volts, 6 to 32 amps C Curve capacity.
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, and neutral, 240 volts, 40 amps C Curve capacity.
Supply and fix in replacement of flexible wire twin core 23/.076 complete all as specified and as directed by Engr-in- Charge.
Supply & fix in replacement PVC FRLS Flexible cable copper conductor, unsheathed , 1100 volts grade confirming to IS:694/1990 of size 1.5 sqmm complete all as specified and as directed by Engineer in Charge.
Supply & fix in replacement PVC FRLS Flexible cable copper conductor, unsheathed , 1100 volts grade confirming to IS:694/1990 of size 2.5 sqmm complete all as specified and as directed by Engineer-in- charge.
Supply & fix in replacement PVC FRLS Flexible cable copper conductor, unsheathed , 1100 volts grade confirming to IS:694/1990 of size 4.0 sqmm complete all as specified and as directed by Engineer-in- charge.
M&L in repairs earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
Supply and fix in repairs 4mm dia GI wire
Supply and fix in repairs tape insulation PVC 25 mm wide in various colours of standard length complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
Excavation in trenches in hard and dense soil n exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipe,foundation for poles, stay, laying cables etc and getting out complete all as directed by engineer-in-charge.
Returning/ filling in including spreading, leveling watering and well ramming in layers n. exc 25 cm in hard/dense soil complete all as directed by engineer-in-charge..
Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point complete all as directed by engineer-in-charge.
M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable complete all as directed by engineer-in-charge.
Supply and laying in repairs well burnt sub class ‘B’ bricks old size as mechanical protection to under ground cables laying across the cable complete all as directed by engineer-in-charge.
Material and labour for cutting of road/ hard standing up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 and block top with black bituminous upto existing surface level complete all as specified and as directed by Engineer-in-charge.
Supply and laying in repairs GI pipe light grade galvanized with all fittings laid in trenches or fix on wall for cable protection of 80 mm bore copmlete all as directed by engineer-in-charge.
All as per srl item No 87 above but size 50 mm bore complete all as directed by engineer-in-charge.
Disconnecting,removing & taking out faulty U/G cable off sizes from trenches,wall and ducts complete all specified and as directed
Supply, Laying, Testing and connecting cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area of 300 sqmm x 3.5 core copmlete all as directed by engineer-in-charge.
All as per srl item No 90 above but size 185 Sq mm x 3.5 core copmlete all as directed by engineer-in-charge.
All as per srl item No 90 above but size 120 Sq mm x 3.5 core copmlete all as directed by engineer-in-charge.
All as per srl item No 90 above but size 95 Sq mm x 3.5 core copmlete all as directed by engineer-in-charge.
All as per srl item No 90 above but size 70 Sq mm x 3.5 core copmlete all as directed by engineer-in-charge.
All as per srl item No 90 above but size 50 Sq mm x 3.5 core copmlete all as directed by engineer-in-charge.
All as per srl item No 90 above but size 35 Sq mm x 3.5 core copmlete all as directed by engineer-in-charge.
All as per srl item No 90 above but size 16 Sq mm x 4 core copmlete all as directed by engineer-in-charge.
All as per srl item No 90 above but size 10 Sq mm x 2 core copmlete all as directed by engineer-in-charge.
Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 240 to 400 sq mm all as specified and directed by engineer-in-charge.
Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 16 to 180 sq mm all as specified and directed by engineer-in-charge.
M & L in replacement FRP juction box including MCBs with front cover fixed with locking arrangement with suitable clamp/fixture on pole complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement PVC insulated Aluminium conductor twin core service cable ISI marked of size 6 Sqmm complete all as specified & directed by engineer in charge
Supply & fix in replacement PVC insulated Aluminium conductor twin core service cable ISI marked of size 10 Sqmm complete all as specified and as directed by Engr-inCharge.
S&F in replacement of MCCB 400 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 36 KA.
S&F in replacement of MCCB 250 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA.
S&F in replacement of MCCB 200 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA.
S&F in replacement of MCCB 160 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA.
S&F in replacement of ACB 630 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 36 KA.
Maintenance and general servicing 'B' Check of DG sets of following capacities of any make including replacing of Engine Oil, oil filter, fuel filter, air Filter, fuel hose, water separator, By-pass filter, air cleaner and topping up of coolant etc. complete including general cleaning including cleaning of accoustic enclosures of DG set with the help of air blowers complete and if required replacing of O ring,nut, bolt,washers etc complete all as specified and as directed by the Engineer-In- Charge. (a) 320 KVA DG set
(b) 200 KVA DG set
(c) 125 KVA DG set Note for items 110 to 112: (i) The work shall be executed only though authorised service provider of OEM of respective DG set. The contractor has to submit MOU with the authorised service provider duly noterised and uploaded at the time of submission of bid documents.(ii) The authorised service provider shall give his complete investigation report of respective DG set seperately on his first visit to each DG set including the complete details of repairs to be carried out with warrantee of 2 years for parts replaced by authorised service provider of OEM.(iii) No repair work other than essential repair work indicated in the investigation report of the service provider for respective DG set will be carried out. (iv) The rate quoted include supply and fixing of carbon brush set with holder, solenoid switch assembly with bush, commuter unit, stator starting and running coil.
Disconnecting all electrical cable connections from the dynamo assembly and taking down the dynamo assembly for carrying out repairs and complete overhauling the system including replacing the unserviceable parts like Carbon brushes, Bearings, Armature. Burnt out coils etc. reassembling and re-fixing the dynamo assembly to its original position and reconnect all disconnected cable connections including testing complete for the following capacities of DGs complete all as specified and as directed by the Engineer-In- Charge. (a) 320 KVA DG set
(b) 200 KVA DG set
( C) 125 KVA DG set Note : The work shall be executed only though authorised service provider of OEM of respective DG set. The contractor has to submit MOU with the authorised service provider duly noterised at the time of submission of bid documents.
Supply & Fix in repairs 24 Volts 30 Amps battery Charger, panel mounting type including removing the unserviceable battery Charger from the existing position complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in repair lead acid maintenance free batteries 180 AH, 12 V, 25 plates complete all as specified and as directed by the Engineer-In- Charge.
Supply and connect in repairs maintenance free lead acid battery 12 Volt, 150 AH complete all as specified and as directed by the Engineer-In- Charge.
Draining out the fuel from the fuel tank of DG Set of various capacity and keeping it in separate container, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, cleaning the fuel tank both internally and externally by removing all the accumulated dust / sediments, leak testing the tank and welding / brazing if required and re-fixing the tank to its original position, replacing the drain plug and PVC pipe protected with steel flexible pipe, calibrating the fuel tank, refilling the drain out fuel back into the tank and provision of locking arrangements complete all as specified and as directed by the Engineer-In- Charge.
Repairs to radiator of copper/aluminium all types taking out by disconnecting from DG set locating the leaking places and trnasposting to workshop for soldering / brazing complete including cleaning with acid and refixing in position complete all as direcetd incl replacement of hoses with new one for DG sets of capacity 125 to 250 KVA complete all as specified and as directed by the Engineer-In- Charge.
Disconnecting and taking down the defective / unserviceable DC wiring and rewiring with same size of cable including supply and replacing of complete wire with flexible pipe, control cable including testing complete for following capacities of DG Set complete all specified and directed by engineer- in- charge :- (a) 320 KVA DG set
(b) 200 KVA DG set
(c ) 125 KVA DG set
Supply and fill distilled water of best quality sealed packing complete all as specified and as directed by the Engineer-In- Charge.
M&L for servicing of AMF panel of DG set of capacity 125 KVA/160/250KVA cleaning of AMF panel, rectification of defect rewiring replacement of D/S indicator,fuse, timer. and new indicator of complete AMF panel and replacement of unserviceable relays under respective item of this schedule complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in repair Auto voltage regulator relay 415V AC as exists complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in repair under voltage relay 300-400V as exists complete all as specified and as directed by the Engineer-In- Charge.
Suppy and fix in repair electronic timer 240V AC, adjustment time 6-60Sec as exists complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in repair engine start relay, 12V DC as exists complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in repair reverse power relay, 415V AC as exists complete all as specified and as directed by the Engineer-In- Charge.
Supply and fixing in replacement of copper terminal end suitable for batteries of capacity 12V 180AH complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in repair earth leakage relay, 240V AC complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of digital multi function meter to read voltage, current and power factor including set of CT-1 each complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of 3 pole power contactor MNX 185 , 185 Amps complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of 3 pole power contactor MNX MNX 300 , 300 Amps complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of 3 pole power contactor MNX 225, 225 A complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement power contractors in built 1 No + INC No auxiliary 3 pole AC 220 Volts type MNX – 12, 30 A complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of 3 pole power contactor MNX 40, 40 A complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of 3 pole power contactor MNX 32, 32 A complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of 3 pole power contactor MNX 70, 70 A complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement power contractors front Add on aux, contact block in built 3 No + 1NC No auxiliary 3 pole AC 220 Volts type MNX (CS9411), 23 to 40 A complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of side mounting add on aux contact block MNX 1 No + 1 NC complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement coil suitable for contactor MNX 185 / MCX 33 with coil voltage 240/415 V complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement coil suitable for contactor MNX 225/MCX 34 with coil voltage 240/415 V complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement coil suitable for contactor MNX 400/MCX - 43 with coil voltage 240/415 V complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of solenoid switch suitable including all necessary arrangement complete all as specified and as directed by the Engineer-In- Charge.
Supply and replace engine oil from engine oil sump with suitable grade oil SAE-20W40 complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement self starter for suitable of 125 KVA DG set capcity including all necessary electrical connections complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement self starter for suitable of 200 KVA DG set capcity including all necessary electrical connections complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement self starter for suitable of 320 KVA DG set capcity including all necessary electrical connections complete all as specified and as directed by the Engineer-In- Charge.
S&F in repair fan belt with provided new fan belt DG set pf capacity 125 complete all as specified and as directed by the Engineer-In- Charge.
S&F in repair fan belt with provided new fan belt DG set pf capacity 200 KVA complete all as specified and as directed by the Engineer-In- Charge.
S&F in repair belt for water pump ( set ) 320 KVA DG set for greevs complete all as specified and as directed by the Engineer-In- Charge.
M&L for de-scaling / Servicing of radiator unit of DG set capacity 200 KVA including draining water, filling & circulating chemical and flushing complete including minor spare as inlet and outlet hose pipes of required size, jublee clamps etc as required complete all as specified and as directed by the Engineer-In- Charge.
S & F in repair of PT fuel pump by dismantling, transporting, repairing and calibration, testing and commissioning of PT fuel pump for 200 KVA DG set including the replacement of all service kits, pulsvation damper, tacho drive shaft and seal, gear drive shaft , bearing, weight carriers, etc complete all as specified and as directed by the Engineer-In- Charge.
M&L for repair to turbo charger of DG set capacity 200 KVA from authorized vendor including testing on test bench complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix oil safety switch to engine of 125/200/320 KVA DG set as per existing complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement exhaust manifold set of three pieces complete with gaskets , stud mountings, nuts etc complete ( centre , rear and front) in 62.5/125/140/160 KVA DG set complete all as specified and as directed by the Engineer-In- Charge.
M&L for repair including replacement of coils , bush/ bearings and other spares as required to alternator/dynamo unit of DG set of capacity 125/160/200 KVA complete all as specified and as directed by the Engineer-In- Charge.
M&L for carry out the tappet setting after opening the top cover to DG set capacity 125/200/320 KVA including replacement of gasket and minor spares as required complete all as specified and as directed by Engineer-in-charge.
M&L for repair the water pump of DG set 125 KVA including replacement of impeller, ball bearing, shaft, spacer, plug and seal complete all as specified and as directed by the Engineer-In- Charge.
S&F in repair Air filter suitable for 125/200 KVA DG set complete all as specified and as directed by the Engineer-In- Charge.
S&F in repair Air filter suitable for 320 KVA DG set complete all as specified and as directed by the Engineer-In- Charge.
S & fix in repairs solid state potentiometer under cummins part no. 3877372 in 140/160/200/380 KVA and testing complete all as specified and as directed by the Engineer-In- Charge.
Supply only coolant for radiator suitable for DG set 62.5/125/140/160/200/380 all as per manufacturers recommendations and complete all as specified and as directed by the Engineer-In- Charge.
S & F in repairs start and stop relay 12 V/24 V DC suitable for AMF Panel capacity of 125/200/320 KVA all as per manufacturers recommendations and complete all as specified and as directed by the Engineer-In- Charge.
S & Fix in repairs Lub oil pressure transducer make Cummins Part no.3392445 in 200 KVA DG set and connecting with DG set system all as per manufacturers recommendations complete all as specified and as directed by the Engineer-In- Charge.
S & Fix in repairs Low lub oil pressure safety make Cummins Part no.3408609 in 125 KVA DG set and connecting with DG set system complete all as specified and as directed by the Engineer-In- Charge.
S & Fix in repairs High water temperature trip safety make Cummins part no.3408624 in 320 KVA DG set and connecting with DG set system complete all as specified and as directed by the Engineer-In- Charge.
S & Fix in repairs harness wiring make Cummins part no. 3056356 in 200KVA DG set and connecting with DG set operating system complete all as specified and as directed by the Engineer-In- Charge.
S & Fix in repair shutdown valve under make Cummins part no. 3239599 in 125/200 KVA DG set complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement AVR unit Suitable for DG set 125 /320 KVA incl connecting with alternator and control panel circuits, starting and testing complete all as specified and as directed by the Engineer-In- Charge.
Supply, installation and commissioning in repairs radiator for 125 KVA Cummins DG set under Cummins Part no. 4020300 including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet complete all as specified and as directed by the Engineer-In- Charge.
Labour only for disconnecting the engine from the coupling, dismantling the Cummins engine 160 KVA water cooled engine cylinder heads, cylinder liner, pistons & connecting rod, injectors, intake and exhaust manifolds and its connected accessories, thorough cleaning and inspection of all removed parts for accessing the servicability, carrring out repair in the engine by replacing the defective / worn out parts, reassembling the engine, carryingout engine valve and injector settings, fixing all removed parts, starting, testing and commissioning complete all as specified and as directed by the Engineer-In- Charge. Note : Parts required to be replace shall be measured and paid seperately.
Complete dismantling of Injector assembly of Cummins DG set engine 160 KVA, carry out repair and servicing by renewing the defective parts / wornout items of barrel and plunger, injector cup, and reassembling the same , calibrating the injector and adjusting the spray pressure timing as per the engine capacity, fixing and testing in the engine complete all as specified and as directed by the Engineer-In- Charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure diem cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure diem cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED street light fitting 90Watt 230 V AC outdoor type with high pressure diem cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type with high pressure diem cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
M/S LADPURIA ENTERPRISES
J.P. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .