Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical BQR Satisfied |
| 2 | Accepted-Technical | Accepted-Technical BQR Satisfied |
| 3 | Accepted-Technical | Accepted-Technical BQR Satisfied |
| 4 | Accepted-Technical | Accepted-Technical BQR Satisfied |
Tender Value
Refer Docs
EMD Value
₹3,500
Closing Date
18 Sept 2026, 2:00 pmClosed
SEES NCTPS2
OFFICE OF SE ES NCTPS II
Sp.41 NCTPS II ES circle MRT Division UnitII Annual Overhauling 2026 27 Maintenance Works Contract Under Open tender Basis.
2026_EB_703761_1
CE NCTPS II SE ES Spec No 41 2026 27
Open Tender
Electrical and Maintenance Works
Works
45 days
NCTPS2
AS PER TENDER SPECIFICATION
2 documents required · 2 mandatory
₹0
₹3,500
Yes
23 Sept 2026
11 Sept 2026
19 Sept 2026
11 Sept 2026
18 Sept 2026
11 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Charges for cleaning and checking the tightness of CT, PT and control circuit terminals in 11KV, 3.3KV and 415V switchboard panels and also assistance during the testing of 217 no. of relays and attending defects, replacing defective relays, CT & PT terminal tightness checking in GRP panels, 11KV, 3.3KV, 415V switchgear panels as instructed by our maintenance engineer in charge. (including consumables cotton/banian waste, cleaning brush, rust removal spray, PU Foam and neccessary tools, hot air blower etc.,) | 210 | Nos | 453.69 | ₹95,274.9 |
| 2 | Charges for checking of the limit switch gear mechanism, manual engage lever assembly, lubrication in the actuator and also topping up if necessary,cleaning the actuator and checking of the power and control terminal tightness. Removing the power and control cables for changing the orientation of the actuator, & during overhauling of the valves to be carried out by Turbine maintenance and Boiler maintenance. Reconnecting the power & control cables and E-pac assembly after completion of overhauling works by TM/BM and checking the operation of both local and remote as instructed by our maintenance engineer incharge. (including consumables cotton/banian waste, rust removal spray, cleaning brush, PU Foam and neccessary tools, hot air blower etc.,) | 120 | Nos | 453.69 | ₹54,442.8 |
| 3 | Cleaning & Testing of Power modules in Variable Frequency Drives of ID FAN. Removing & cleaning of Power modules & Voltage snubber circuits from VFD Thyristor bridge panel after disconnection of Gate, Cathode, NTDA card connection & pulse transformer circuit. Testing of each Thyristor cell in Power module and refixing of power module and Voltage snubber circuit in VFD Thyristor bridge panel reconnecting the same.(including consumables cotton/banian waste, rust removal spray, cleaning brush, PU Foam and neccessary tools, hot air blower etc.,) | 96 | Nos | 2,262.6 | ₹2,17,209.6 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_845921.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .