| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.4 LAdmitted-Finance | -14.86% | ₹8.4 L | L1 | Admitted-Finance |
| 2 | L2₹8.7 LAdmitted-Finance | -11.17% | ₹8.7 L | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Others-Affidavit uploaded but not as per dnit favoring in Engineering Department, Chandigarh Administration. |
Tender Value
₹9.8 L
EMD Value
₹19,660
Closing Date
22 May 2026, 11:00 amClosed
Hospital Engineer (Electrical)
Electrical Division, First floor, SPH, PGI, CHd
Annual Preventive Maintenance of 11KV Substation installed at Nehru Hospital Extension Block, PGIMER, Chandigarh
2026_PGIME_908394_1
PGI/Engg./Elect./2026-27/06
Open Tender
Electrical Works
365 days
Electrical Division, First floor, SPH, PGI, CHd
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹19,660
Yes
27 May 2026
12 May 2026
23 May 2026
12 May 2026
22 May 2026
12 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | One time complete preventive maintenance and testing of Voltamp Make 1600 KVA dry type transformers as per scope of work. The work is to be executed by the authorised channel partener/authorised service agency of OEM. | 3 | Job | 43,173 | ₹1,29,519 | BI01010001010000000000000515BI0100001113 |
| 2Repair and servicing of HT VCB trolley 11KV including dismentaling of old defective spare parts from the panel, cleaning, lubrication and fixing of new spares, checking of On Off operation, mechanical and electrical operaitons and required correction complete as required and testing of the panel as per following. | ||||||
| 2.1 | 1. Testing of CT, PT and relay with primary & secondary injection kit. | - | - | - | - | BI01010001010000000000000515BI0100001115 |
| 2.2 | 2. Tripping of VCB, through over current and earth fault relay. | - | - | - | - | BI01010001010000000000000515BI0100001116 |
| 2.3 | 3. Bus Bar testing | - | - | - | - | BI01010001010000000000000515BI0100001117 |
| 2.4 | 4. Megger Value. | - | - | - | - | BI01010001010000000000000515BI0100001118 |
| 2.5 | 5. Contact resistance testing | - | - | - | - | BI01010001010000000000000515BI0100001119 |
| 2.6 | 6. Aux. Relay testing for transformers | - | - | - | - | BI01010001010000000000000515BI0100001120 |
| 2.7 | The above work to be executed by the authorised channel partener/authorised service agency of OEM (Make CG) | 5 | No. | 27,137 | ₹1,35,685 | BI01010001010000000000000515BI0100001121 |
| 3 | One time complete Servicing cum Overhauling of ACBs upto 2500A. (Make - Schneider-17 Nos & Legrand-2 Nos) The work is to be executed by the authorised channel partner/authorised service agency of OEM | 19 | Job | 14,391 | ₹2,73,429 | BI01010001010000000000000515BI0100001122 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.80 MB
BOQ_954734.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid