Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹12.1 L+₹67,889 (5.95%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹12.5 L+₹1.1 L (9.65%)Rejected-Finance | L3 | Rejected-Finance Not being lowest |
Tender Value
₹13.1 L
EMD Value
₹27,000
Closing Date
18 Dec 2020, 6:00 pmClosed
GE (AF) B/R Chakeri Kanpur
GE (AF) B/R Chakeri Kanpur
ADDITION/ALTERATION TO LPG CYLINDER GAS GODOWN AND DOUBLE FENCING OF STATION LOGISTICS SECTION AT AF STN KANPUR
2020_MES_393813_1
GE(AF)/CHK/T-42 OF 2020-21
Open Tender
Civil Works
Item Rate
182 days
GE (AF) B/R Chakeri Kanpur
Class E and cat a(i)
8 documents required · 8 mandatory
₹500
GE (AF) B/R Chakeri Kanpur
₹27,000
11 Jan 2021
9 Nov 2020
22 Dec 2020
9 Nov 2020
18 Dec 2020
5 Dec 2020
9 Nov 2020 - 20 Nov 2020
Amount
M & L for river Ganga sand laying over existing floor, laid in layers not exceeding 10 cm thick spread, levelled and well rammed inluding watering complete all as specified and directed.
Dismantling wall or ceiling boards (AC sheet, fibre, pulp insulation etc) in any thickness and at any height complete all as specified and directed.
Dismantling timber scantling over 40 Sqcm sectional area as framed work in any position complete all as specified and directed.
Dismantling timber scantling under 40 Sqcm sectional area as framed work in any position complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces etc complete all as specified and directed.
M & L for preparation of old steel and iron surfaces of any description exceeding 10cm girth or width and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for 15 mm thick plastering on fair faces of brick wall or concrete surfaces in CM (1:6) finished even and smooth without using extra cement and preparation of new plastered surface of walls and applying two coat of oil bound distemper over one coat of primer over and including 1 to 2 mm thick wall care putty complete all as specified and directed.
M & L for 15 mm thick plastering on fair faces of brick wall or concrete surfaces in CM (1:4) finished even and smooth without using extra cement and applying two coat of cement based paint on newly prepared plastered surfaces of walls over a coat of chalk whitening complete all as specified and directed.
Complete removal of existing treatement of wall surfaes and M & L for preparation of surfaces by using of sand paper and applying two coat of oil bound distemper over a coat of primer over and including 1 to 2 mm thick wall care putty complete all as specified and directed.
M & L for preparation of old decorative plastered surface of walls and applying one coat of cement based paint complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of newly steel surfaces of any description exc. 10cm width or girth complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thick bellow or above ground level including tiles etc. complete all as specified and directed.
Demolition of brick work built in Cement mortar from brick wall complete all as specified and directed.
M & L for brick work with fly ash brick straight or cuved on plan exceeding 6.0 m mean radius built in CM(1:6) using of old size bricks complete all as specified and directed.
Taking down chowket or frame not exceeding 1.50 sqm with shutters (wihtout taking of shutter from frame) etc complete all as specified and directed.
Ditto all as per above item No.15.00 here-in-before but exceeding 1.50 Sqm but not exceeding 4.00 Sqm
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and 1.40 mm average width of aperature fixed with tinned tacks or galvanised wire staple complete all as speficied and directed.
Dismantling of asbestos cement (corrugated or semi corrugated etc) sheet in roof covering complete all as specified and directed.
S & F 6 mm thick asbestos cement sheets corrugated or semi corrugated fixed with 'L' type or 'J'' hook and washers as in roof covering etc. complete all as specified and directed.
Fixing only old asbestos cement (corrugated or semi corrugated) sheets fixed with and including M&L for 'L' type 'J' type hook or cranked bolt and washers complete all as specified and directed.
S & F 0.63 thick plain galvanised steel sheeting with 120 gm Zinc (spelter) coating per sqm both sides inclusive as in ridges, hips, valley gutters drip and straight flashing fixed with L or J type hook and washers complete all as specified and directed.
M & L for providing PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping, benching, roof curb, rounded or chamferred on edges or over pipes finished top surface even and smooth without using extra cement at any height complete all as specified and directed.
M & L for framed MS work as in steel doors including gusset plate, rails, bracket, MS plate, steel sheet and angle section, flat section conforming to Fe - 410 complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation of drainage line etc (manualy) or similar work and getting out in soft/loose soil complete all as specified and directed.
M & L for TMT bars of 10 mm and over dia cut to length bent to shape as required including cranking bending spirally for hooking ends and binding with mild steel wires (annealed not less than 0.9 mm dia) complete all as specified and directed.
Ditto all as per item no.25.00 here-in-before but for 6 to 8 mm dia bars.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as surfaces channel and drains complete all as specified and directed.
M & L for use of formwork for sides of RCC drains, faces of wall for fair finished surface complete all as specified and directed.
M & L for RCC M-20 (Nominal Mix) using 20 mm graded stone aggregate as in drain/channel complete all as specified and directed.
S & F 15 mm bore GI pipe medium grade with all fittings such as bend, elbow, socket, tees and fixed complete to wall or in ceiling or in floors including cutting threading and making forged bends on pipes MS hooks etc. complete all as specified and directed.
S & F bib taps of PTMT any colour scewed for iron pipe (Min Wt 110 Gms) complete all as specified and directed.
S & F 40 mm bore GI pipe medium grade with all fittings such as bend, elbow, socket, tees and fixed complete to wall or in floors including cutting threading and making forged bends on pipes MS hooks etc. complete all as specified and directed.
S & F 40 mm dia Gun metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe complete all as specified and directed.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in window/ door cills and lintels and similar articles complete all as specified and directed.
M & L for providing pre-cast RCC cover slab etc of cement concrete type B-1 (1:2:4) using 20 mm graded stone aggregate and set in (1:6) cement mortar complete all as specified and directed.
M & L for 50 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in floors finished even and smooth without using extra cement complete all as specified and directed.
M & L for 100 mm thick PCC (1:4:8) type B-2 using 40 mm graded stone aggregate as in sub base of floor finished rough to receive topping layer complete all as specified and directed.
M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Surface excavation not exceeding 30 cm and average 15 cm in soft/loose soil complete all as specified and directed.
M & L for moorum/ red bajri filling in floors or paving, laid in layers not exceeding 15 cm thick sread, levelled watering and well rammed complete all as specified and directed.
M & L for 20-25mm thick polished kota stone of size 550 mm x 550 mm as in flooring set in neat cement slurry mixed with colour over and including 20 mm thick screed bed in CM (1:6) complete all as specified and directed.
M & L for 20-25 mm thick polished kota stone of size 550 mm x 550 mm as in dado/shirting set in neat cement slurry mixed with colour over and including 10 mm rendering in CM (1:3) complete all as specified and directed.
M & L for PCC (1:2:4) type B-2 using 40 mm graded stone aggregate complete all as specified and directed.
Excavation in post holes each not exc 0.50 Cum, getting out, returning filling, in and ramming earth or broken rubble mixed with earth around in layers not exceeding soft/loose soil complete all as specified and directed.
S & F galvanished, 2 Strand, steel barbed wire of size 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and staining and fixing to any type of standard rails staining bolts, including securing or typing at crossing with and provision of galvanished mild steel wire, staples or steel pins etc complete all as specified and directed. Note-Each line wire to be measured.
S & F angle section or other steel sections for post and struts in fencing including cutting tops to shape as directed, drilling holes noching for wires, etc. flat iron fillets including all necessary drilling, bolting or reventting, welding and embedding in concrete etc and similiar work conforming to Fe-290 Gde E-165 complete all as specified and directed by GE/Engr-in-Charge.
Taking down unservicable MS Conduit point wiring from existing place ( Light fan, socket or power point) complete with all unservicable fittings such as switches, sockets, ceiling rose, pendants holders etc and making good to disturbed surface to wall, floor etc to match with existing surface either by using same colour distemper, putty or white / colour wash complete all as specified and directed.
M & L for flame-proof concealed point wiring on wall and surface wiring on ceiling / roof / Hanger with necessary fixing arrangments with stranded PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 Volts grade drwan in and including 16 Gauge stove enameled ERW rigid steel conduit (metallic) not less than 19 mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC-FRLS insulated andand unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 Volts grade for continous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching finishing of new surface either by means of plaster of Paris / Putty or Distemper / colour wash with same existing colour surface complete all as sppecified and directed by Engr-in-Charge for one light, fan point controlled by one switch complete all as specified and directed.
S & F in repair flame proof weather proof threaded type junction box LM-6 Aluminium alloy- 2 way complete all as specified and directed.
Ditto all as per Item No. 49.00 here-in-before but for 3-way
S & F in repair flame proof weather proof metallic hose conduit 3/4" dia 300mm long complete all as specified and directed.
S & F in repair flame proof weather proof switch with cable termination in LM 6 Aluminium alloy Housing 16 amp, 240 Volts complete all as specified and directed.
S & F in repair double metallic enclosure for DB when MCB's to be used SPN 4 ways, 240 V with IP 54 Protection with 200 Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/ wires complete all as specified and directed.
S & F in repair testing and commissioning of MCB SP 240 Volt 6 Amp to 32 Amp 10 KA capacity having 'C-Curve' charactestics complete all as specified and directed.
Ditto all as per item No.54.00 here-in-before but for SPN 16-32 Amps complete all as specified and directed.
S & F in repair flame proof waeather proof LED luminiare 2 X 16/20 W, epoxy finish with LM 6 Aluminium Housing, heat resistant borosillicate tubular glass held in two aluminium cups with inbuilt driver accessories & LED tubelight complete including taking down old unservicable. Make : Crompton cat Pt No. EXTN1LT8-16/20 or equivalent make or model in Havells/Wipro as approved by GE in writting complete all as specified and directed.
Excavation in trenches soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m depth for laying of under ground electric cable and getting out complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thickin any type of soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and spreading Ganga Sand dry, clean in trenches as cushining to underground electric cable provided with three layer of 80 mm thick before laying and 150 mm thick over cable laid in trenches complete all as specified and directed. Note : Punned thickness sand shall be measured and piad only.
Supply and laying dry bricks over cable laid in trenches as mechanical protection to cable with width equal to the length of bricks with well burnt sub class 'B' bricks complete all as specified and directed.
M and L for LT cable of size 10 Sqmm 2 Core complete all as specified and directed.
M & L in replacement for LED Building security light 110 Watt of Aluminium PDC housing glass cover with IP 66 Protection. Make : Philips cat part No. BRP 410 LED 110 BCW HE MR FG S2 PSU GR or equivalent make or model in Havells/Wipro as approved by GE in writting complete all as specified and directed.
S & F in repair switch flush type single pole one way 5 Amps, 240 Volts, White Finish ISI marked complete all as specified and directed.
S &F in repair ceiling rose surface backlite of size 65 mm X 20 mm three nterminal conforming ISI marked complete all as specified and directed.
Bindra Builders
aarohi nirman company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .