Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹45.1 L+₹3.5 L (8.30%)Rejected-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L2 | Rejected-AOC NOT LOWES | |
| 3 | L3₹46.0 L+₹4.3 L (10.4%)Rejected-AOC 19 AIRVIEW APARTMENT VAKOLA BRIDGE NEHRU ROAD SANTACRUZ EAST MUMBAI 400 055 | MUMBAI SUBURBAN | MAHARASHTRA | 400055 | L3 | Rejected-AOC NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
24 Jun 2020, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI 400088
SPL REP TO CIV EST SEC IN CABS PROVN OF ESCAPE LADDER IN BLDG P-44 PROVN OF 01 RCC SEPTIC TANK SOAK WELL NEAR BLDG NO P-5 P-6 P-7 P-11 AT NAD PROVN OF RAIN WATER HARVESTING AT NOFRA AND CERTAIN REVENUE WORKS UNDER GE (NW) MANKHURD
2020_MES_339317_1
8976/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) MANKHURD
AS PER NIT AND TENDER PAGES
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹90,000
Yes
10 Jul 2020
17 Apr 2020
26 Jun 2020
17 Apr 2020
24 Jun 2020
11 Jun 2020
17 Apr 2020 - 2 May 2020
Amount
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed
Demolition cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking down chowkhat or frame (without taking off shutter from the frame) exceeding 1.5 Square Metre not exceeding 04 Square Metre each , removing from the site including cutting holes required for taking out existing hold fast etc. complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubish off the premises complete all as specified and directed
S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame, shutters for doors, window / ventilators, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed. Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes, wire cloth shall be measured and paid separately as supply only under respective items.
Supply only 9mm thick prelaminated particle, board, interior grade, prelaminated both sides with decorative choice laminations, fixed with screws to aluminium frame work complete all as specified and directed
Supply only sheet glass 5 mm thick quality fixing to wooden /aluminium frame door/ window shutters in any position with new beads/ steel section as required for securing including dismantling of old jalli and painting to match with existing complete all as specified and as directed.
Supply and fixing hot dipped GI imposed grid with 24mm wide T sect exposed flanges powder coated frame work comprising of main runner made from 0.33 mm thick GS sheet of size 24mmx32mmx3000 mm @1200 mm C/C GI wire 4mm dia fixed by rawl plug,level adjusters and screws etc flush fitting of 1200mm long cross tee interlocked between main runners @ 600mm c/c to form 1200mmx600mm modules cross tee longer than 600 mm to be supported independently 600mmx600mm modules shall be formed by fitting 600mm long cross tee centrally between 1200mm cross tee, perimeter wall angle shall be GS of size 19mmx19mm and 0.45 mm thick 300mm long inclucing 600mmx600mmx8 to 10mm thick PVC laminated board of make armstrong/gypsum board / Ramco / Bisan complete all as specified and directed.
M&L 40 mm thick plain cement concrete type B1, 1:2:4 (using 20 mm graded aggregate) as in subbase of flooring complete all as specified and as directed
S&F for aluminium (Die cast body) hydraulically Door closer regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed as in repairs complete all as specified and directed
M&L in repairs for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed including taking down and refixing of shutter complete all as specified and directed
Taking down cement plaster on brick or stone walls/ceiling, etc, including raking out joints, hacking for key, scrubbing down with water , etc complete all as specified and directed.
Chipping, removing carefully loose/damaged concrete incl plastering (total thickness upto 60mm ) from RCC surfaces of columns, beams,Chajas, soffits of slabs etc in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land, even including necessary scaffolding up to 24 m height complete all as specified Note: 1. Hard concrete shall not be removed by force. Note : 2. Item No 13 will not be applicable for the location/areas where item No 12 is applicable.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit or Monobond SBR of M/s. Krishna Conchem or Shalicrete URP of STP Ltd as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application including necessary scaffolding up to 24 m height complete all as specified and directed
M&L for cleaning existing reinforcement by sand blasting with suitable pump as directed by the GE and wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make Feovert of Krishna Conchem or Roffrust cleaner of 'Pidilite' or 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed.
M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed .
M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit or Shalifix RMSG 01 of STP Ltd while the bonding agent is still sticking upto 20mm thickness including levelling, profiling etc complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of bricks or concrete surface work in CM 1:6, finished the surfaces even & smooth with sagol finish complete all as specified and directed
M& L rendering 10 mm thick in CM 1:3 on ceiling surface finished even & smooth with sagol finish complete all as specified and directed
M&L for prepration of newly plaster surface of wall and applying two coat of distemper oil emulsion on walls with one coat of primer over a coat 3mm thick white cement based putty complete all as specified and directed
M&L for preparation of newly plastered surfaces of celings and applying two coats of OBD complete all as specified and directed
M& L for preparing old surfaces walls of distempered & painted surfaces and applying one coat of oil bound distemper complete all as specified and directed
M&L Preparation of old plastered or un-plastered surface of ceiling and applying one coat of OBD complete all as specified and directed.
S&F Vitrified light shade ceramic tiles 10 mm thick (square/rectanglar) polished area of each tile not exceeding 0.36 sqm ,in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over & including 15mm in CM (1:6) bedding layer complete all as specified and as directed.
All as per item No 24.00 but as in skirting /dado laid over 10 mm thick in CM (1:4) bedding layer complete all as specified and directed
Taking down carefully aluminium sliding window shutters from the frames or chowkhat and supply and fix New locking arrangement in place of old one and re-fixing the same shuters in existing position etc, complete all as specified and directed
Taking down existing aluminium joinery of any description (frame/ shutters) with all fittings (but excluding grills) complete all as specified and directed.
M & L for Machine cut cudappah stone slab 18-20mm thick over cement screed base, laid and mixed with pigment to match the shade of the slab window cills and jambs to full thickness of wall fixed in steps over & including cement screed bed 10mm thick in CM 1:4 and jointed with grey cement paste and slurry including rubbing and polishing complete all as specified and directed
S&F aluminium anodised Grills of approved design for window / ventilators and fixing with F/U channel for window, ventilators, balcony opening in architectural or rectangular type in existing bldg including drilling as required in RCC sections in rectangular or architectual type balcony opening in existing building, complete all as specified and directed. Note: The Grills shall be of Model DG-100/DG-102 of Make Deco or equivalent make as specified in PS
Taking down existing glass door n.exc 1.5 Sqm and refixing the same in same or other position , complete all as specified and directed
M&L RCC M-30 (Design Mix) (using 20 mm graded aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc basement slabs, under-reamed piles and mass concrete etc all as specified and directed. Note : Design mix shall be carried out from approved lab such as Govt College/ IIT/ NIT/ SEMT Pune or any NABL approved lab.
M & L RCC M-30 (Design Mix) (using 20 mm graded aggregate) in Columns, pillars, piers, posts and struts all as specified and directed. Note : Design mix shall be carried out from approved lab such as Govt College/ IIT/ NIT/ SEMT Pune or any NABL approved lab.
Use and waste of formwork to sides of rough finished surface of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beam and similar work vertical or batter all as specified and directed.
Use and waste of formwork to rough finished surface of square, rectangular or polygonal sides of pillar, posts, struts, piers, columns and stanchions all as specified and directed.
M&L for CRS bar 10mm dia and over, cut to lenth,bent to shape required,including cranking bending spirally for hooping for columns,hooping ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
All as per item No 35.00 but 8 mm dia bars complete all as specified and directed
All as per Item No 35.00 but 5mm dia and over upto including 10mm dia in stirrups, spacers and binders complete all as specified and directed
Returning,filling in,including spreading, levelling,watering and well ramming in layers n.exc 25cm thick in soil complete all as specified and directed
Removing excavated material outside MD land and depositing outside MD land complete all as specified and directed.
S&F rolled mild steel section as in Plate girder or single stanchions, built up of one beam of channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections plates. Guesette plates, wind ties, fastening, nuts, bolts etc, conforming to Fe 410-W(E-250 grade quality 'B'), complete all as specified and directed
M&L rolled mild steel as in Stairs (framed) including stringers, treads, landing, balusters, hand rails etc, including cleats, brackets, etc with MS Angle flat etc confirming to Fe- 410 Gde E. complete all as specified and as directed.
S&F rolled mild steel as in Plates (chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed .
S&F mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 gde E complete all as specified and directed
S & F rolled Mild Steel as in Framed work as in doors or Gates of angle or other section confirming to Fe 410 - S, with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering and hanging and fixing complete all as specified and directed.
M&L Cutting openings, through brick walls for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc., to store and rubbish not exc. 50m complete all as specified and directed
M & L for brick work in CM (1:6) using sub class 'B' bricks strainght or curved as required on plan exc 6mtrs mean radius etc complete all as specified and directed.
M&L PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in coping hold fast, bed plate etc including necessary form work complete all as specified and as directed.
M&L for rendering 20 mm thick ( 15+5 mm )on fair faces of bricks or concrete surface work in CM 1:4, finished including with integral water proofing compound 3% for 5mm thick plaster by weight of cement finished fair and even including necessary scaffolding up to 24 m height as sand faced finish complete all as specified. Note - WPC shall be measured and paid separately.
M & L for preparation of new plastered surfaces of wall etc and applying two coats of 100% anti fungal acrylic exterior emulsion paint over one coat of primer all as per manufacturer's instructions including necessary scaffoldings upto 24 mtr etc, complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
M & L two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of previously untreated surfaces of steel and iron exc 10 cm width or girth complete all as specified and directed.
Excavation in trenches, n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in average soil complete all as specified and directed.
Excavating in over area n. exc. 1.5 m in depth; for foundation, etc.and getting out in average soil complete all as specified and directed.
Excavating in over area exc. 1.5 m and n exc 3 mtr in depth; for foundation, etc.and getting out in average soil complete all as specified and directed
Excavating in over area exc. 3.0 m and n exc 4.50 mtr in depth; for foundation, etc.and getting out in average soil complete all as specified and directed.
Excavating in over area exc. 4.50 m and n exc 6.00 mtr in depth; for foundation, etc.and getting out in average soil complete all as specified and directed.
M & L for hardcore with broken stone or boulders of gauge n exc.63mm, deposited, spread & levelled in layers n exc 15cm thick, watered & rammed to a true surface complete all as specified and directed.
M & L plain cement concrete Type D2 1:4:8 (40 mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed
M&L RCC M-30 (Design Mix) (using 20mm graded aggregate) in Walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed Design mix shall be carried out from approved lab such as Govt College/ IIT/ NIT/ SEMT Pune or any NABL approved lab.
M&L PCC block masonry with solid blocks, grade C (5.0) exc 10 cm in width and setting in cement mortar (1:6) etc complete all as specifiend and directed.
All as per item No 60.00 but as in honey comb block walls complete all as specified and directed
M&L PCC block masonry with solid blocks, grade C (5.0) n.exc 10 cm in width and setting in cement mortar (1:4) etc complete all as specifiend and directed.
M & L RCC M-30 (Design Mix) (using 20mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed Design mix shall be carried out from approved lab such as Govt College/ IIT/ NIT/ SEMT Pune or any NABL approved lab.
M & L RCC M-30 (Design Mix) (using 20mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like complete all as specified and directed Design mix shall be carried out from approved lab such as Govt College/ IIT/ NIT/ SEMT Pune or any NABL approved lab.
Use and waste formwork for rough finished surfaces to walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to better complete all as specified and directed
Use and waste of formwork to sides and soffits of rough finished surface of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etccomplete all as specified and directed.
Use and waste of formwork to soffits of fair finished surfaces of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) complete all as specified and directed
M & L for providing precast cement concrete type A1 1:1.5:3 (using 20mm graded stone aggregate) in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:6 complete all as specified and directed
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed
M & L rendering 15 mm thick in CM (1:3) on fair faces of brick work or concrete surfaces, finishing the surface even and smooth (without using extra cement) and applying a setting coat 5 mm thick in CM 1:2, trowelled to even and smooth finish complete all as specified and directed.
M&L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed
M & L for two coats of black bituminous paint on surface of any description wood, steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth complete all as specified and directed
Moorum /red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering complete all as specified and directed
S & F 110 mm dia PVC (SWR) vent cowl complete all as specified and directed
M & L RCC NP-2, 150 mm dia pipes laid and jointed complete with collars complete all as specified and directed.
M & L salt glazed stoneware single Tee / Y junction 150 mm dia complete all as specified and directed
M&L loose filling with aggregates of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and directed
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed
M & L RCC NP2, 300 mm dia pipes laid and jointed complete with collars complete all as specified and directed.
M & L for 50 mm thick PCC floor (1:2:4) type B-1 (using 20 mm graded aggregate) finished even and smooth using extra cement complete all as specified and directed.
M&L rendering 15mm thick on fair faces of brick masonary or conrete surface in CM 1:4 finished even and smooth(without using extra cement) mixed with WPC @3% by weight of cement complete all as specified and directed
Supply only Liquid water proofing compound complete all as specified and directed
M& L for two coats of water proofing coating on newly plastered surface with Shalicrate-47 of STP or equivalent.(All as per manufacturar instruction) complete all as specified and directed
M&L for loose filling with broken brick bats in soakage pit/well etc complete all as specified and directed
M&L for loose filling with charcol in soakage pit/well etc complete all as specified and directed
S&F 1.50m dia and 300mm high and 25mm thick precast RCC perforated ring for rain water harvesting complete all as specified and directed.
S&F 0.9m dia and 300mm high and 25mm thick precast RCC perforated ring for rain water harvesting complete all as specified and directed.
M&L for loose filling with broken aggregate of gauge 40 to 80mm in soakage pit/well etc complete all as specified and directed
S&F 150 mm dia PVC slotted pipe for rain water harvesting inlet pipe in existing borewell including takeing down old one complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to wall complete all as specified and directed
All same as per item No 90 but laid in trenches or in floor complete all as specified and directed
Supply only PVC bend 110 mm dia complete all as specified and directed
M & L for plain Cement concrete Type B-1 1:2:4 (using 20 mm graded stone aggregate) as in surface channels and drains complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etccomplete all as specified and directed.
Add or deduct for each 25 mm girth or part thereof over or under 30 cm -ditto-
M& L for cutting into road/hardstanding or similar item for laying PVC rain water pipe line or similar work getting out the excavated materials and filling the same with excavated soil and top 150mm with PCC (1:2:4) type B2 complete all as specified and directed
Providing design and diagram for rain water harvesting system for 2 building of approx catchment area each of 450 sqm and discharge into one existing borewell all as per standard building norms/rules complete all as specified and directed.
Demolition of stone slabs and tiles laid beded and pointed in any mortar of any description or thicknes in floors , aprons etc complete all as specified and directed
M&L 100 mm thick plain cement concrete type D2, 1:4:8 (using 40 mm graded aggregate) as in sub base of flooring complete all as specified and as directed
M&L Machine pressed precast concrete interlocking paver block Coloured any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over and including 25 mm thick sand cushion complete all as specified and directed
Excavating post holes or similar holes, each not exceeding 0.5 Cu. M, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface complete all as specified and directed
S & F MS steel work in tubular trusses and tubular posts and square tubes including special shaped washers etc., complete using but welded tubes confirming to IS 1239- 1979 graded St 240 or square hollow section conforming to IS-4923-1997 graded St-210 and revise from time to time complete all as specified and directed.
M&L for Durastone Heavy Duty vitrified tiles (300x 300) x 10-12 mm thick in floor set and jointed with neat cement slurry and pointed in coloured cement to match over screed bed or bedding layer of mortar 20 mm in cement mortar 1:6 complete all as specified and directed.
Taking down carefully old unserviceable copper / aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings and making good disturbed suface of wall, floors, ceiling etc complete all as specified and directed Notes : (i)The contractor should be in possession of valid electrical license to execute electrical works. (ii) Supervisor for execution of electrical works/ electrical component of works employed by the contractor shall possesses supervisor certificate of competency issued by concerned State Government/ Union Territory and the worker/ tradesmen for execution of electrical works/ electrical component of works shall hold necessary permit issued by concerned State Government/ Union Territory.
M & L for Point wiring complete 1.5 Sqmm, single core, PVC insulated FRLS, unsheathed, 1100 Volts grade multistranded copper conductor drawn through in and including PVC casing caping in walls/roofs including PVC insulated copper earth continuity conductor 1.5 Sqmm cable (green) connected to common earth dolly including pressed steel terminal boxes 50 mm deep in walls with laminated sheet top cover 3 mm thick for housing the switches, sockets, regulators etc. all as specified for : (a) One light/fan/bell point controlled by one switch
All as per item No 105 above but One 5 Amps 2 pin / 3 pin switch socket outlet multipurpose on Independent Board
All as per item No 105 above but wiring complete with 2.5 Sqmm for 3 pin 15A switch socket multipurpose on independent board
S & F Switch Piano, flush type, single pole, one way, 5 Amps, 230 Volts complete all as specified and directed
S & F Ceiling Rose, surface bakelite, three terminals, AC, 230 Volts complete all as specified and directed
S & F Switch Socket combination 2 in 1, 5 Amps, 5 pin multipurpose, flush type, 230 Volts complete all as specified and directed
S & F Switch Socket combination 5 in 1, 15 Amps, 6 pin multipurpose, flush type, 230 Volts complete all as specified and directed
S & F Ceiling fan regulator electronic stepped type, AC, 230 Volts, flush type complete all as specified and directed
Taking down main switch/DB/ changeover/AC box of any capacity including fixing accessories complete all as specified and directed
S&F sheet metal enclosure , 32A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 32 Amp fixed properly on in concealed position complete all as specified and directed.
S & F MCB DB 12 way SPN, double door, vertical type, IP - 43 with 200 Amps rated bus bar, AC and connecting up complete all as specified and directed.
S & F MCB SPN 40-63 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity complete all as specified and directed
S & F MCB SP 6 to 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity complete all as specified and directed
S&F surface, hanging and wall mounted batten (double side connection) suitable for LED tube 20/22 watts, 230 volts alongwith tube rod 22 Watt (double side connection), including fixing mounting blocks 2 Nos, 15 mm MS conduit if required, 1.5 sqmm, 3 Core PVC insulated copper conductor cable including fixing arrangements complete all as specified and directed. Make : Havells/ Bajaj/ Pyrotech/ Crompton/Benlo/ Halonix
M&L for sub main wiring with two single core 4.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 4 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
M&L for sub main wiring with two single core 6.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 6 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
Taking Down Ceiling fans 1200/1400 mm sweep and Exhaust Fan any size transporting to store for safe custody for reuse or for depositing at the MES Yard.
Fixing only ceiling fan 1200/1400 mm sweep and Exhaust Fan any size as obtained from taking down vide Ser No 121 herein before including painting of celing fan and Exhaust fan complete all as specified and directed
Taking down LED light fittings from false ceiling and refixing the same, including provision of three core copper conductor cable of size 1.5 Sqmm to connect from ceiling rose to light fitting all as specifed and directed. Note : A sum of Rs 12,811.00 towards sch of credit shall be deducted to arrive the contract sum.
Joy builders
GAJANAN SALES CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .