| 1 | L1₹1.8 CrAccepted-AOC PLOT NO 279 SHASTRI NAGAR SHIV COLONY KARNAL HARYANA 132001 | KARNAL | KARNAL | HARYANA | 132001 | ₹1.8 Cr Quoted ₹2.1 Cr | L1 | Accepted-AOC ok |
| 2 | L2₹2.1 Cr+₹5.1 L (2.43%)Rejected-Finance GALI NO 9 SHIV COLONY KARNAL RURAL PART 1 KARNAL HARYANA 132001 | KARNAL | KARNAL | HARYANA | 132001 | ₹2.1 Cr+₹5.1 L (2.43%) | L2 | Rejected-Finance L2 |
| 3 | Not Admitted-Fee/PreQual/Technical 452 6 KRISHAN NAGAR TEHSIL CAMP PANIPAT 132103 | PANIPAT | HARYANA | 132103 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Sh. Vikas Sharma L2 | RUDARMANI SHARMA CONTRACTOR L1 |
|---|---|---|---|---|---|
| 1.00 | Making inter connection of proposed pipe line with existing pipe line of DI/CI including excavation dewatering etc. complete in all respect as directed by Engineer-in-charge for following dia. (i) 80-200 mm dia meter proposed pipe line. | 50 | Nos. | 3,700 ₹1,85,000 | 3,584 ₹1,79,200 Lowest |
| 2.00 | The work of repairing the house hold sewer line which is broken while laying water pipe line complete in all 4` connection with PVC Pipe. PVC Pipe Make:- Finolex/ Supreme. | 500 | Nos. | 1,280 ₹6,40,000 | 1,153 ₹5,76,500 Lowest |
| 3.00 | The work of repairing the house hold sewer line which is broken while laying water pipe line complete in all 6` connection with PVC Pipe. Make:- Finolex/ Supreme. | 130 | Nos. | 1,500 ₹1,95,000 | 1,320 ₹1,71,600 Lowest |
| 4.00 | P/F 20mm House Service Connection from the main/ distribution drinking water pipe line. (incl. dismantling, excavation and refiling back of trench) GI Pipe and Nipple Make:- Jindal Hissar/ Ravindra, Union/ Elbow in Heavy Duty, Ferrule in Brass Heavy Duty.
Note:- Payment will be made as per Actual work done at site. | 1,240 | Nos. | 1,800 ₹22,32,000 | 1,696 ₹21,03,040 Lowest |
Tender Value
₹1.7 Cr
EMD Value
₹3.3 L
Closing Date
24 Feb 2026, 5:00 pmClosed
Pardeep Kalyan
Municipal Corporation Karnal
Laying/ Replacement of Existing Damage Old AC/ PVC/ CI Water Pipe Line (3,4,6 dia) With Road Restoration in Various Streets of Ward No. 01 to 20 except HSVP Sectors Under M.C Karnal (Work will be executed as per demand and necessity M.C. Karnal.)
2026_HRY_502558_1
20267F67C344 56A1 437E B3A0 0F64662FD14F747ULB
Open Tender
Civil Works
Works
549 days
Karnal
2 documents required · 2 mandatory
₹15,000
₹3.3 L
Yes
25 Mar 2026
13 Feb 2026
25 Feb 2026
13 Feb 2026
24 Feb 2026
13 Feb 2026
Making inter connection of proposed pipe line with existing pipe line of DI/CI including excavation dewatering etc. complete in all respect as directed by Engineer-in-charge for following dia. (i) 80-200 mm dia meter proposed pipe line.
The work of repairing the house hold sewer line which is broken while laying water pipe line complete in all 4` connection with PVC Pipe. PVC Pipe Make:- Finolex/ Supreme.
The work of repairing the house hold sewer line which is broken while laying water pipe line complete in all 6` connection with PVC Pipe. Make:- Finolex/ Supreme.
P/F 20mm House Service Connection from the main/ distribution drinking water pipe line. (incl. dismantling, excavation and refiling back of trench) GI Pipe and Nipple Make:- Jindal Hissar/ Ravindra, Union/ Elbow in Heavy Duty, Ferrule in Brass Heavy Duty. Note:- Payment will be made as per Actual work done at site.
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
[10.100.2]Cement Concrete 1:8:16 Flooring 2. Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. [Through Rate]
[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate]
[17.3]Dismantling of flexible pavement by Mechanical Means Bituminous course [Through Rate]
[17.69.2]Interlocking Concrete Block Pavement 2. Providing and Laying 80 mm thick ISI marked Interlocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect. [Through Rate]
[17.70]Removal of existing IPB by manual means and disposal of dismantled material with all lead and lift as per technical specification clause 202.3. [Through Rate]
[17.71]Relaying of available (removed and stacked) Interlocking Paver Block Pavement having thickness 100mm/80 mm/ 60 mm (average = 80mm) as per drawings and Technical Specification Clause 1504 [Labour Rate]
[20.58.1]Providing and fixing Cast Iron Detachable Joints class-15 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 1. 80mm i/d CID Joint [Through Rate]
[20.58.2]Providing and fixing Cast Iron Detachable Joints class-15 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 2. 100mm i/d CID Joint [Through Rate]
[20.58.3]Providing and fixing Cast Iron Detachable Joints class-15 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 3. 150mm i/d CID Joint [Through Rate]
[20.63.2]`Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade SandS pipes as per 15:8329-2000 (amended up to date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/W to be measured and paid separately. ` 2. 150 mm i/d [Through Rate]
[20.64.1]Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade SandS pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/W to be measured and paid separately. 1. 100 mm i/d [Through Rate]
[20.66.1]Cutting DI pipe and chipping or filling the surface to a uniform finish 1. 100 mm i/d [Through Rate]
[20.66.2]Cutting DI pipe and chipping or filling the surface to a uniform finish 2. 150 mm i/d [Through Rate]
[20.68.1]Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths Ductile Iron (DI) standard specials plain /flanged/ socketed confirming to IS9523-2000 with rubber ring (EPDM/SBR) joints such as tees, bends, tapers, caps etc. with in trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. 1. Up to 300mm dia [Through Rate]
[20.69.1]Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths cast iron (CI) standard specials plain /flanged/ socketed confirming to IS13382 with rubber ring, nut bolts and rubber sheet such as tees, bends, tapers, caps etc. complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. 1. Up to 300mm dia [Through Rate]
[22.162.1.1]Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 1.1. 100 mm diameter Class I [Through Rate]
[22.162.3.1]Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 3.1. 150 mm diameter Class I [Through Rate]
[22.91.2]Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. External work 2. 20 mm dia nominal bore [Through Rate]
[3.1.5]By Mechanical Transport including loading, unloading and stacking 5. Sand, stone aggregate below 40 mm nominal size [5km]
[4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate]
[5.23.1]Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1. Nominal concrete 1:1.5:3 or richer mix (i/c equivalent design mix) [Through Rate]
[5.23.2]Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 2. Nominal concrete 1:2:4 or leaner mix (i/c equivalent design mix) [Through Rate]
[6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate]
[6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate]
[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate]
[6.34.3]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 3. Cold twisted bars [Through Rate]
[7.22.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.80 MB
BOQ_581223.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .