Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-Finance | L1 | Accepted-Finance BOQ found in order. | |
| 2 | L2₹31.7 L+₹2.6 L (9.00%)Accepted-Finance | L2 | Accepted-Finance BOQ found in order. | |
| 3 | L3₹32.0 L+₹2.9 L (9.84%)Accepted-Finance | L3 | Accepted-Finance BOQ found in order. | |
| 4 | L4₹39.9 L+₹10.8 L (37.1%)Accepted-Finance | L4 | Accepted-Finance BOQ found in order. | |
| 5 | L5₹44.2 L+₹15.0 L (51.6%)Accepted-Finance | L5 | Accepted-Finance BOQ found in order. |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
15 Apr 2024, 6:00 pmClosed
Garrison Engineer(North) Akhnoor
Garrison Engineer(North) Akhnoor PIN 181201 CO 56 APO
COMPREHENSIVE REPAIR/MAINT OF DG SETS, EARTHING AND CONNECTED ITEMS OF WATER AND ELECTRIC SUPPLY INSTALLATION INCLUDING E/M INSTALLATION REPAIR TO PLATFORM, TILLING WORKS AND CONNECTED ITEMS AT AKHNOOR UNDER GE (NORTH) AKHNOOR
2024_MES_646887_1
CANO- GE(N)/AKH-51/2023-2024
Open Tender
Support/Maintenance Service
Item Rate
180 days
Akhnoor
Class D Cat b i
8 documents required · 8 mandatory
₹500
GE (North) Akhnoor
₹94,000
Yes
25 Apr 2024
18 Mar 2024
19 Apr 2024
18 Mar 2024
15 Apr 2024
1 Apr 2024
Amount
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers are to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
All as per item No-2 here-in-before but for One light point/fan /bell point controlled by one switch.
-Ditto- All as per item No-2 here-in-before but for One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
-Ditto- All as per item No-2 here-in-before but for One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
Material and labour for point wiring complete with 2.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 2.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers are to be used of same make/brand only and shall be deemed in to included in quoted rate only.) for One 15 amps power socket outlet point controlled by one 16 amps switch on independent board.
Modular type switch 6 Amps, single pole, 1way,1 module, 240V, ISI Marked including Modular cover plate with frame Complete all as specified and as approved by GE. “Cat part No:- Crabtree (Havells) or its equivalent cat part of make Anchor, Legrand, Schneider as approved by GE”.
Modular type switch 16 Amps, single pole, 1way,1 module, 240V, ISI Marked including Modular cover plate with frame Complete all as specified and as approved by GE. “Cat part No:- Crabtree (Havells) or its equivalent cat part of make Anchor, Legrand, Schneider as approved by GE”.
Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked including Modular cover plate with frame Complete all as specified and as approved by GE. “Cat part No:- Crabtree (Havells) or its equivalent cat part of make Anchor, Legrand, Schneider as approved by GE”.
Modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI Marked including Modular cover plate with frame Complete all as specified and as approved by GE. “Cat part No:- Crabtree (Havells) or its equivalent cat part of make Anchor, Legrand, Schneider as approved by GE”.
Fan regulator modular type electronic compatible with BLDC fan, stepped type 100 Watts, 2 module 240Volts, AC ISI marked complete all as specified and directed. “Cat part No:- Crabtree (Havells) or its equivalent cat part of make Anchor, Legrand, Schneider as approved by GE”.
Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed.
Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
Electric bell ding dong type 230 volts AC supply 50 Hz complete all as specified and directed.
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 12 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, blanking plates where required testing and commissioning in replacement, complete all as specified. Make:- Havells cat part No-DHDPSHODPW12 or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE.
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, blanking plates where required testing and commissioning in replacement, complete all as specified. Make:- Havells cat part No-DHDPSHODPW08 or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE.
Isolator SPN 100Amps complete all as specified and directed. Make of Legrand, Schiender, Havells & L&T as approved by GE.
Isolator SPN 63Amps complete all as specified and directed. Make of Legrand, Schiender, Havells & L&T as approved by GE.
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) single poles and current carrying capacity in the MCB 5-32Amp complete with connection testing and commissioning all as specified and directed.
Sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FRLS type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLS type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
S&F in repair white/ warm white powder coated CRCA housing with LEDs 36W, 230 V, 50 Hz Surface mounting LED 2 feet x 2 feet luminaries, Sweamless front frame with flat white light transmission acrylic cover complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified. Cat Part No-BZRSQL of Bajaj or its equivalent of Philips, Surya, Wipro, GE as approved.
S&F in replacement LED light fitting 1x10W bulk head luminaries IP 65 complete with all accessories including LED lamp 10 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz Cat part No LW07-141-XXX-57 G1 Make Wipro or equivalent in Phillips, Bajaj, Surya, GE as approved.
S&F in repair Integrel sleek LED extruded batten with aluminium housing channel fitting with LED 18 watt 4 feet complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V 50 Hz., complete all as specified. Cat Part No-BS18 WLED 830SPCSS of Havells or its equivalent in Bajaj, Wipro, Orient, Jaquar, GE as approved.
Surface excavation n exc 30cm deep and averaging 15 cm deep and getting out in any type of soil, complete all as specified and directed.
Rolling and consolidating of soling of broken boulders not exceeding 15cm thick with power roller exc 5 tonne and nexc 8 Tonne, complete all as specified and directed..
Hardcore of broken stone or boulder of guage exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick, watered and rolled/rammed to a true surface, complete all as specified and directed..
Plain Cement concrete type D2 1:4:8 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
40mm thick plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregrate) as in floors , finishing surface even and smooth by using extra cement, complete all as specified and directed.
25 mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mmgraded crushed stone aggregrate) as in sub base to path/floors, complete all as specified and directed.
Machine pressed precast concrete interlocking paver block (ISI marked) any shape and size confirming to IS 15658-2006 of 60mm thickness with grey cement and pigment M35 Grade, complete all as specified and directed.
Sand filling under floors or in foundation or packing the side of paver block including watering and consolidation, complete all as specified and directed.
Supply and fixing in replacement “Lithium based Energy Efficient Integrated Solar Street Light of 20Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 44/46Wp , Lithium Battery 11.1/12.8V, 24.2AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower lightl evel with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 10-12kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required.Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of Cat Part No-PLLEDSSLINTG20W of Make HPL or its equivalent of Bajaj/Phillips as approved.
Supply and fixing in repair Glow sign board made of acrylic sheet reactangular shape with frame of having lighting arrangement of superior quality of size 6x4 sqft showing installation Nomenclature as approved marked all as specified and directed. Note: Installation line diagram to be enfaced will be approved by AGE E/M and no extra will be paid of any addition and alteration of words or marking of colours.
Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary , gusset plates, riveting etc n exc 10 Kg each brackets, conforming to Fe.290. Gde E-165 (Brackets over 10 Kg each to be measured under "Structural Steel"), complete all as specified and directed. Note-(i) Quoted rate shall also include cost of fabrication and fixing at site. (ii) Earthwork & PCC shall be measured & paid seperately under respective item.
Dismantling of floor hearth or wall tilling incl cement mortar bedding and removing unsv tiles and rubbish off the premises, complete all as specified and directed.
Glazed ceramic coloured tiles (450x300mm) x 7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick back coat layer in cement mortar 1:4, complete all as specified and directed.
Machine cut Kota stone slab flooring 20-25mm thick laid over cement screed base and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete over and incl screed bed 15mm thick in cement mortar 1:6 including dismantling of old flooring all as specified and directed.
Taking down false ceiling including snap grid of any size and Supply and fixing anodised aluminium snap grid frame work for false ceiling size of grid 605 x 605 mm including 12mm Non-asbestos fibre cement building tiles of size 600mmx600mm with G.I perimeter channels 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to wall and intermediate channels 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at Approx 900mm centre to centre with GI cleats and GI Hangers adjusted level fixed to roofs slabs by means of ceiling cleats made out of GI flat and fasteners 12.5 mm dia , 40mm long complete all as specified.
Rendering 15mm thick on fair faces of brick wall or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and directed.
Applying two coats of cement base paint first quality over & including priming coat incl preparation newly plastered surface of wall, complete all as specified and directed.
Taking down old unsv flood lights of any type and M&L for LED flood light of capacity 250 watt IP 66 Lumainire with aluminium die cast housing toughened glass and unique lens system for enhancement illumination complete with all accessories complete all as specified and directed. Make Wipro cat part No LF3 -342-060-57XX or equivalent in specification of make phillips, Wipro, GE
Dismantling fencing,wire mesh any type size, complete all as specified & directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in concrete, brick work, masonry etc and making good disturbed ground, complete all as specified. Notes :- This item shall also include the demolition of foundation concrete/hard core and taking out the posts and struts carefully and removing the same from site.
Dismantling framed trusses n exc 10m span, complete all as specified and directed. .
Excavation in post holes each not exceeding 0.5 cum getting out in any type of soil, returning, filling in, including spreading, leveling, watering and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, complete all as specified.
TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as specified and directed.
Mild steel angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mesh etc). Including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed.
Reinforced cement concrete 1:2:4 Type B-1 (Using 20mm graded crushed aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc basement slabs, complete all as specified and directed.
Supply & fixing MS galvanised chain link fencing of mesh 100 x 100mm including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified.
Preparation of new or previously untreated steel surface of any descprition including washing and cleaning etc. not ortherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified.
Preparation of old painted surface not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Material and labour for carrying out ‘B’ check for various capacity DG set by replacing the following accessories of DG set . (a) Oil filter. (b) Air filter. (c) Fuel filter. (d) By pass filter. (e) Engine oil . (f) coolant. Note :- (i) 'B' checks shall be carried out by OEM of company .Certification of the same shall be submitted. (ii) Engine oil & coolant shall be measured and paid separately.
DG set of capacity up to 100 KVA.
DG set of capacity above 100 KVA and up to 250 KVA.
DG set of capacity above 250 KVA and up to 500 KVA.
Engine oil 15W/40 for toping up upto the required level and service complete all as specified and directed by Engr-in-Charge. Make-Mak, Servo, Castrol
Supply only Coolent as per manufacturers instructions and as approved. Make-Castrol, Kirloskar, Gulf
Supply and fix Battery brass terminal and jelly complete all as specified and directed.
Dismantling & disconnecting all connection of upper and lower engine, cylinder heads, lines, thrust valve,valve seat inlet and exhaust,main bearing set,inlet valve and exhaust valve,head gasket, CR bearing,hose set,ring set,valve seal,liner O ring,oil seal set,O rings kit,Crank shaft ,Connecting roads, Push roads,Value Guides, Valves seats and all connecting items like ring, washer,gasket etc from diesel engine and sent to OEM authorised Service center for calibration and repairs by replacing the all above said spares such as cylinder heads, lines, thrust valve,valve seat inlet and exhaust,main bearing set,inlet valve and exhaust valve,head gasket,CR bearing,hose set,ring set,valve seal,liner O ring,oil seal set,O rings kit,Crank shaft ,Connecting roads,Push roads,Value Guides, Valves seats and all connecting items like ring ,washer,gasket etc and re-assembling to its original position with necessary fittings and O rings for the following capacities including testing complete all as specified and directed.
DG Sets of capacity up to 160 KVA.
DG Sets of capacity above 160 to 250 KVA.
DG Sets of capacity above 250 KVA.
Replacement of microprocessor based control unit suitable to DG set controls/commands of up to 100 KVA capacity with all listed parameters as per recomendation including testing complete all as specified and directed.
Replacement of microprocessor based control unit suitable to DG set controls/commands of above 100 kVA to 250 KVA capacity with all listed parameters as per OEM recommendation including testing complete all as specified and directed.
Replacement of microprocessor based Display unit(HMI) suitable to DG set controls/commands of above 250 KVA to 400 KVA capacity with all listed parameters as per OEM recommendation including testing complete all as specified and directed.
Supply anf fixing Copper lugs 120 sqmm to 150 sqmm suitable for 1100 Volt copper cable suitable for existing DG set including removing old unserviceable one complete all as specified and directed.
Taking down defective Turbo Charger Assembly duly disconnecting the mechanical and electrical connections from for the DG sets of capacity upto 200 KVA, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit including spares as required at site and reassembling and refixing the turbo charger assembly to its original position and reconnecting the same including testing complete all as specified and directed.
Taking down defective Turbo Charger Assembly duly disconnecting the mechanical and electrical connections from for the DG sets of capacity above 200 KVA to 400 KVA, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit including spares as required at site and reassembling and refixing the turbo charger assembly to its original position and reconnecting the same including testing complete all as specified and directed.
Draining out the fuel from the fuel tank of DG set of any size/capacity and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements ccomplete all as specified and directed .
Dismantling of fuel injection pump overhauling, repairing and replacement of worn out parts of FIP, calibration and testing of fuel pump uptp 250 KVA DG set and testing on test bench and adjustment of injectors and setting of fuel pressure as per manufacturer instructions, complete all as directed.
Dismantling of fuel injection pump overhauling, repairing and replacement of worn out parts of FIP, calibration and testing of fuel pump above 250 KVA to 400 KVA DG set and testing on test bench and adjustment of injectors and setting of fuel pressure as per manufacturer instructions, complete all as directed.
Disconnecting the engine from alternator of DG set upto 125 KVA capacity including all electrical connections, dis-assembling the alternator to carry out the rewinding of armature and rewinding of field coils, including transportation of alternator to workshop and bringing back to site for re-assembling after repairs, re-installation at site and reconnecting alternator with engine including testing on load complete all as directed.
Disconnecting the engine from alternator of DG set above 125 KVA to 250 KVA capacity including disconnecting all electrical connections, dis-assembling the alternator to carry out the rewinding of armature and rewinding of field coils, including transportation of alternator to workshop and bringing back to site for re-assembling after repairs, re-installation at site and reconnecting alternator with engine including testing on load complete all as directed.
Disconnecting the engine from alternator of DG set above 250 KVA and upto 400 KVA capacity after disconnecting all electrical connections including dis-assembling the alternator to carry out the rewinding of armature and rewinding of field coils, including transportation of alternator to workshop and bringing back to site for re-assembling after repairs, re-installation at site and reconnecting alternator with engine including testing on load complete all as directed.
Earthing complete with galvanised steel earth plate electrode 600mmx600mmx3.15mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground) with top edge of plate not less than 1.5m below normal ground level connecting to the GI erthing strip 32x6mm by means of bolts, nuts check nuts and washers of galvanised iron and GI Strip 32x6mm protected by provision of GI Light grade pipe of 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 40mm grade crushed stone aggregrate iwh 40mm thick cover of RCC (1:2:4) raniforced with PM (weight not less than 4Kg/sqmm) and frame of angle iron 25x25x6mm with lugs 02 Nos and 6mm dia MS bars handle made to shape, GI Light grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge for earth platem common salt and charcoal filling, test point made out of 75x50x6mm phodphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hand/ dense soil filling in andremoval of surplus soil to a distance not exceeding 50m all as per electrical plate No-03 of SSR 1991 Pt-I and connecting to earh test point incl testing on completion, complete all as specified.
Supply and fixing glow sign board made out of bakelite sheet digital enfacement of letters, incl heavy duty MS pipe frame related to installation assets as per site requirement and as directed by Engr-in-Charge to fix in position etc complete all as specified and directed.
Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 95 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 120 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying cable including getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading watering and well ramming in layers not exc 25 cm complete all as specifed .
Removing surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed .
Brick protection to cable with one layer of sub class 'B' brick, old size,brick covering laid dry, flat, tranversally along the length of cable on sand cushioning with equal to the length of brick, complete all as specified and directed.
Sand cushioning to under ground cable, 8 cms thick before laying the cable and 15 cms thick after laying and stretching the cable in trenches including hand punning and consolidating, punned to 18cm thickness, complete all as specified and directed. Note : For payment purpose, only punned thickness shall be measured.
Replacement of battery 12/24 Volt, 180AH alongwith battery lead terminal and cut out arrangement, complete all as specified and directed. Make: Exide/Amaron/Standard/Microtek.
Replacement of battery 12/24 Volt, 90AH alongwith battery lead terminal and cut out arrangement, complete all as specified and directed. Make: Exide/Amaron/Standard/Microtek.
Removing the defective charging dynamo of capacity 12/24 Volt DC any make, model, any capacity and opening it by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling, lubricating, rewinding the damaged winding of field coils with super enamelled copper wire suitable for same existing size/guage & reconnecting the same, refixing back in original position including making all necessary electrical/mechanical connections, testing and commissioning complete all as specified and directed.
Self starter Motor, 12/24 volts, suitable for existing DG set above 10 KVA to 500 KVA capacity including making all necessary electrical/mechanical connection as per recomendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position complete all as specified and directed.
LAL CONSTRUCTIONS
narayan construction
sahni construction co
M/S JIWAN SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .