| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.7 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹49.9 L+₹22,747 (0.46%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹50.0 L+₹28,725 (0.58%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹51.5 L+₹1.8 L (3.57%)Rejected-Finance D 235 ADG P CHENNAI | CHENNAI | TAMIL NADU | 600001 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹52.0 L+₹2.3 L (4.56%)Rejected-Finance 121004 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
23 Jan 2020, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR REPLACEMENT OF SUBMAIN WIRING MAIN DBS UNSV MCBS BLDG EARTHING AND OTHER MISC EM WORKS IN DOMESTIC AND TECHNICAL AREA AT AF STN SULUR
2020_MES_311337_1
GE(AF)/SUL/Token/53 of 2019-2020
Open Tender
Miscellaneous Works
Item Rate
210 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹98,000
Yes
7 Feb 2020
2 Jan 2020
24 Jan 2020
2 Jan 2020
23 Jan 2020
17 Jan 2020
2 Jan 2020 - 16 Jan 2020
Amount
SCHEDULE A BOQ
Excavation in trenches not exceeding 1.5m depth and not exceeding 1.5 mtr in wide in hard/dense soil and getting out.
Removing of excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
Fly ash cable protection cover of size 23x11.5 x7.5cm including taking down existing bricks of any size.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit, RIGID 19/20 mm dia, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 8 here in before but for one 3 pin socket out 5 amp on the same board
All as per item No. 8 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 8 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing Caping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Casing Capping : Modi/ Presto Plast/ Polycab Make of Wire : Plaza/ Polycab/ Havells Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
One light point/fan/bell point controlled by one switch
All as per item No. 13 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 13 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 13 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Switch piano flush type 15 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Shuttered socket outlet 3 pin 5 amps, flush type
Shuttered socket outlet 2 in 1, 3 pin, 5 and15 amps
Supply only modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Recess mounting powder coated luminaire white CRCA full glow LED ceiling lights indoor 2'x2' not less than 36watt, colour temperature white complete including taking down existing all as specified and directed. Make : Philips Cat No RC365BLED33-6500 PSU OD WH or equivalent in Wipro/ Bajaj Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with one run 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F in replacement of all in one integrated solar street light of less than 18W with 3000 lumen and system lumen efficiency of more than 170 lumen per watt. The luminaire shall use highly efficient microcontroller based integrated MPPT charge controller, both charger and driver to be on same board with more than 90% efficiency of both charger and driver. High grade aluminium die-cast housing to ensure good heat dissipation. The luminaire shall have flexi mount of 0 to 15 degree to adapt to certain geography diversity. The luminaire shall be with smart self-diagnosis feature with LED indicators alongwith battery charging and deep discharging out off indications. The system shall use long time maintenance free lithium Ferro Phosphate (Li Fe PO 4) battery with BIS certification. Battery capacity of minimum 170 wh for autonomy of 24 hrs with fully charged battery. The luminaire shall be with hybrid feature (integrated/ seperated) ON-OFF switch, Outer mounting diameter of 48-60 mm. Operating temp range for light engine is 0 to +35 Dep C. operating humidity shall be upto 95%. System lumen output should be atleast 12V DC, 2000 lm. Solar panel module capacity of 12V, 35W Peak Mono-crystalline. Solar cell efficiency with min 12%. LED burning hrs to be 50,000 hrs at L70. Rating of IP 65 and IK 08 to comply with UV stabilized poly carbonate front cover. Colour temp of 5700K and CRI > 70. Make : Philips Cat No BRP 710 LED 30 series with Hy brid option or equivalent in Wipro/ Bajaj.
Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report including BIS certification. (b) The contractor shall submit warranty certificate from manufacturer for minimum 5 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall also submit safety and performance standard compliance of IEC 60598-2-3 for road and street lights, IEC 62109-1 for power converters used in Solar Panel, EN 50530 for MPPT performance evaluation, IEC 61607 for EMC immunity, CISPR 15 for Radio disturbance characteristics, IEC 62133, IEC 61960 and UL 1642 for safety of lithium Ferro Phosphate battery and IEC 61730-1, 2 & IEC 61215 for safety of solar panel module. (e) The rates quoted deemed to be included 6 mtr long MS/ GI pipe of 50mm dia medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engineer-in-Charge.
Electronic energy meter 3 Phase 30 to 60Amps range capacity. Make : BENTEC / L&T/ABB
S&F in replacement IP 65 Polycarbonate 8 Way MCB distribution board of size 420 x 320 x 138mm with polycarbonate hinges, fitted with color coded sheathed bus bas, neutral bar, earth bar, DIN channel with 8 way IP 65 polycarbonate window for easy operation of MCB’s. The enclosure should be dust and water proof, rust proof, shock proof with anti-cracking, high temp resistant silicon sealing gaskets for weather proof outside mounting. It should be CE for safety of humans with absolutely no sharp corners. Flame retardant UL94VO, UV resistant, Impact IK08, halogen free and ROHS complaint, confirming to IEC 60529, the enclosure should have in built outside holes for easy mounting on wall/ pole and DB should be suitable for flush/ wall mounting. All hardware used should be made of SS304. Make :- Schneider/ Grasp/ Hensel Note :- The contractor shall submit test report from the manufacturer to comply with all requirements and specifications given in the contract.
S&F IP 66 LED bulkhead luminaire, consuming a power of 9W. Lumen output not less than 1080 lumens with a system efficacy > 115 lm/W, translucent UV stabilised poly carbonate anti-glare diffuser, colour temp not less than 6500K, PF > 0.95 shall have 50,000 burning hours as per L70 criteria, with surge protection device minimum 2KV, LED driver with constant output voltage and current at input voltage of 110 Volt to 270 Volt AC at 50 Hz,. The bulkhead body base should have inbuilt provision for easy mounting on wall/ ceiling with PVC insulated copper conductor 3 core cable of 0.5 sqmm. The body of luminaire should be dust, water and all weather proof for out side mounting and should be manufactured with flame retardant UL 94VO, UV resistant, glow wire test 960° impact IK 10, Halogen free, ROHS compliant, conforming to IEC 60529, complete as specified. The luminaire shall be BIS certified. Make :- Philips/ Bajaj/ Grasp Notes:- 1. The Contractor shall submit test report from manufacturer of LED fittings giving detail of each parameter /specifications of led luminaire mentioned in the BOQ item. 2. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 3. The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 50 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 8-10 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation. Make : Model HTSP 3I7 of safeTrode or equivalent in JEF ECO safe earthing, OBO Betterman/ ENNOV/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre in 02 canes (5 ltrs per cane) for each pit deemed to be included in the quoted rate.
(iii) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( The rate of earthing strip up to 7.5 Mtrs is included in the quoted rate).
(iv) The electrode shall carry manufacturer's name .
(v) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(vi) Testing of earth shall be carried out along with the departmental and user representative and report shall be submitted to Garrison Engineer for his entire satisfaction.
(vii) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(x) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xi) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xiii) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(xiv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
Supply and fixing Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE or equivalent in JEF ECO safe earthing, OBO Betterman/ ENNOV/ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 6 sq mm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through Steel conduit with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). Make of Cable : Plaza/ Polycab/ Havells Make of Casing Capping : Polycab/Modi/ Diplast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lups) only.
One light point/fan/bell point controlled by one switch
One switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No-52 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
4 feet surface mounted battern type luminaire with a power consumption not more than 16 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 120 lm/W with an operanting voltage range from 140V-270V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than. The luminaire shall have a CCT of 6500 K, CRI>80, power factor>0.95, SDCM<5, THD<10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC complaint and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability (The driver can be replaced at site level). The luminaire shall not weight more than 7 Kg and the luminaire and driver shall be BIS approved with "R" number mentioned. Make : Philips Cat Part No BN308 LED20S 6500 L120 PSU WH or equivalent in Bajaj or schreder.
Note for item No 56 :- (a) LED Chip make shall be Nichia, Osram, Cree, Lumilid. (b) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two run 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 4 runs of 4 sqmm cable along with two run of 4 sqmm cable for earth conductor shall be measured as one length including taking down UNSV old wiring. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two run 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 4 runs of 6 sqmm cable along with two run of 4 sqmm cable for earth conductor shall be measured as one length including taking down UNSV old wiring. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Road lighting luminaire of 36 watt LED street light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and taking down UNSV street light fittings including taking down existing all as specified and directed, Make : Philips Cat No BRP 409 LED CW 036 MR FG S1 PSU GR/Wipro/ Bajaj . Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Replacement of convetional type boolard fitting with LED bollard light fittings suitable for 1x9 watt LED bollard in rectangular shaped vicotria design with opal acrylic diffuser and IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed. Make /cat part No. CG cat no. LBLSN-10-CDL or Bajaj Cat Part No. BGBOS 600 9W LED /philips.
Electronic energy meter single Phase 5 to 30Amps range capacity. Make : BENTEC / L&T/ABB
Replacement IP 65 polycarbonate MCCB distribution board of size 200 x 280 x 130 mm with inbuilt hinges, four pole, 125 amp breaking capacity 16 KA MCCB conforming to IEC-61439-1 complete with IP 65 polycarbonate window for easy operation of MCCB. The polycarbonate enclosure should be dust, water and all weather proof for outside mounting, flame retardant UL 94VO, UV resistant, glow wire test 960°, impact IK 08, Halogen free and ROHs complaint,, conforming to IEC 60529, complete all as specified. Make :- L&T/ Schneider/ Hensel/ Grasp Note :- The contractor shall submit test report from the manufacturer to comply with all requirements and specifications given in the contract.
Wiring for circuit complete submain wiring with 2 X1.5 sqmm single core PVC insulated, unsheathed FRLS 100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl 1.5 sqmm single core wire PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing sub main wiring of any size and all as specified. Note :- Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Replacement of convetional type post top fitting with LED Post tops lamp fitting 1x45 W LED made die cast aluminium with innovative glare free indirect lighting ditribution & IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed.Make/cat part No. CG cat no. LPTO-40-CDL or Bajaj Cat Part No. BRIL 45 W LED NW /philips.
Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC casing caping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Wire : Plaza/ Polycab/ Havells Make of Casing Capping : Polycab/Modi/ Diplast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lups) only.
One light point/fan/bell point controlled by one switch
All as per item No. 67 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 67 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 67 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with one run 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 sq mm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 35 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Road lighting luminaire of watt 20 watt LED 2000 lumens street light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and taking down UNSV street light fittings all as specified and directed, Make : Philips Cat No BRP022 LED 20 CW MR S1 PSU GR or equivalent in Wipro/Bajaj. Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Replacement of all in one integrated solar street light of less than 28W with 4500 lumen and system lumen efficiency of more than 170 lumen per watt. The luminaire shall use highly efficient microcontroller based integrated MPPT charge controller, both charger and driver to be on same board with more than 90% efficiency of both charger and driver. High grade aluminium die-cast housing to ensure good heat dissipation. The luminaire shall have flexi mount of 0 to 15 degree to adapt to certain geography diversity. The luminaire shall be with smart self-diagnosis feature with LED indicators alongwith battery charging and deep discharging out off indications. The system shall use long time maintenance free lithium Ferro Phosphate (Li Fe PO 4) battery with BIS certification. Battery capacity of minimum 170 wh for autonomy of 24 hrs with fully charged battery. The luminaire shall be with hybrid feature (integrated/ seperated) ON-OFF switch, Outer mounting diameter of 48-60 mm. Operating temp range for light engine is 0 to +35 Dep C. operating humidity shall be upto 95%. System lumen output should be atleast 12V DC, 2000 lm. Solar panel module capacity of 12V, 35W Peak Mono-crystalline. Solar cell efficiency with min 12%. LED burning hrs to be 50,000 hrs at L70. Rating of IP 65 and IK 08 to comply with UV stabilized poly carbonate front cover. Colour temp of 5700K and CRI > 70. Make : Philips Cat No BRP 710 LED 45 series with Hy brid option or equivalent in Wipro/ Bajaj.
Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report including BIS certification. (b) The contractor shall submit warranty certificate from manufacturer for minimum 5 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall also submit safety and performance standard compliance of IEC 60598-2-3 for road and street lights, IEC 62109-1 for power converters used in Solar Panel, EN 50530 for MPPT performance evaluation, IEC 61607 for EMC immunity, CISPR 15 for Radio disturbance characteristics, IEC 62133, IEC 61960 and UL 1642 for safety of lithium Ferro Phosphate battery and IEC 61730-1, 2 & IEC 61215 for safety of solar panel module. (e) The rates quoted deemed to be included 6 mtr long GI pipe of 50mm dia medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engineer-in-Charge.
Replacement IP 65 Polycarbonate 4 Way MCB distribution board of size 300 x 225 x 100mm with polycarbonate hinges, fitted with color coded sheathed bus bar, neutral bar, earth bar, DIN channel with 4 way IP 65 polycarbonate window for easy operation of MCB’s. The enclosure should be dust and water proof, rust proof, shock proof with anti-cracking, high temp resistant silicon sealing gaskets for weather proof outside mounting. It should be CE for safety of humans with absolutely no sharp corners. Flame retardant UL94VO, UV resistant, Impact IK08, halogen free and ROHS complaint, confirming to IEC 60529, the enclosure should have in built outside holes for easy mounting on wall/ pole and DB should be suitable for flush/ wall mounting. All hardware used should be made of SS304. Make :- Schneider/ Grasp/ Hensel Note :- The contractor shall submit test report from the manufacturer to comply with all requirements and specifications given in the contract.
Replacement IP 65 polycarbonate MCCB distribution board with size 200 x 280 x 130 mm with inbuilt hinges, four pole, 63 amp breaking capacity 16 KA MCCB conforming to IEC-61439-1 complete with IP 65 polycarbonate window for easy operation of MCCB. The polycarbonate enclosure should be dust, water and all weather proof for outside mounting, flame retardant UL 94VO, UV resistant, glow wire test 960°, impact IK 08, Halogen free and ROHs complaint,, conforming to IEC 60529, complete all as specified. Make :- L&T/ Schneider/ Hensel/ Grasp Note :- The contractor shall submit test report from the manufacturer to comply with all requirements and specifications given in the contract.
Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC Conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Avon Plast/ Supreme/ Diplast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lups) only.
One light point/fan/bell point controlled by one switch
All as per item No. 80 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 80 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 80 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Replacement IP 65 polycarbonate MCCB distribution board with size 200 x 280 x 130 mm with inbuilt hinges, four pole, 100 amp breaking capacity 16 KA MCCB conforming to IEC-61439-1 complete with IP 65 polycarbonate window for easy operation of MCCB. The polycarbonate enclosure should be dust, water and all weather proof for outside mounting, flame retardant UL 94VO, UV resistant, glow wire test 960°, impact IK 08, Halogen free and ROHs complaint,, conforming to IEC 60529, complete all as specified. Make :- L&T/ Schneider/ Hensel/ Grasp Note :- The contractor shall submit test report from the manufacturer to comply with all requirements and specifications given in the contract.
Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end
eurekaenterprises
D.R ASSOCIATES
T C KARUNANITHI
Neptune Engineers and Builders
kaarthic builders
rvelectricals
NAVEEN ENTERPRISES
KUMAR AGENCIES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .