Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹15.7 L+₹7,698.40 (0.49%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹16.7 L+₹1.1 L (6.95%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹17.7 L+₹2.1 L (13.3%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹18.7 L+₹3.1 L (19.7%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹40,460
Closing Date
28 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bhisiana
GE (AF) Bhisiana PIN-151201
As per BOQ/ Price Schedule
2023_MES_630422_1
GE/BHI/CAP-03/2023-24
Open Tender
Civil Works
Item Rate
273 days
GE (AF) Bhisiana
As per NIT/ Tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Bhisiana
₹40,460
29 Feb 2024
1 Dec 2023
30 Dec 2023
1 Dec 2023
28 Dec 2023
14 Dec 2023
1 Dec 2023 - 12 Dec 2023
Amount
Supply,installing,testing and commissioning factory made and CPRI type tested 100 KVAR APFC panel (50+25+15+5+5) Indoor type platform mounted, suitable for 415 volts 3 phase 4 wire 50 Hz AC Supply copper having bus bar of rating 1.5 times that of incoming MCCB installed.The panel shall be dust and vermai proof IP-54 class protection and made of 3.15 mm CRCA MS sheet and 50 x 50 x 6mm thick angle iron frame work; front opening type with double door shutter and locking arrangement with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface. The panel is including platform with PCC 1:4:8 type D-2 with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 3 mtr above the nearest road level all as directed by Engr-in-Charge. All interconnection between the main bus bar as well as outgoind feeders shall be carried out with TP copper bus bar of rating not less than 1.5 time rated capacity of individual outgoing feeders and should be insulated with colour coded shrinkable PVC sleeves. The MCCB should be adjustable type. The body of the panel shall be powder coated . Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift panel safely shall be made. The incommer MCCB as well as outgoings shall have copper TPN extension links (not less than 300 mm long) of current carrying capacity not less than 1.5 times the rated capacity of individual feeders and should be insulated with heat shrinkable PVC sleeves. All control wires shall be of 2.5 sqmm multi stranded copper conductor (FR) and shall be properly bunched, tied,ferruled for proper identification and crimped with adequate size of lugs. A detachable predrilled powder coated gland plate of thickness 3.15 mm should be used at the bottom. The scope of work includes provision of following :- (i) MCCB TP 3 pole 315 Amps 25 KA thermal setting 80-100%, O/C, S/C release-01 No (INCOMING) (ii) MCB TP, C-curve, 3 pole 10 KA 63 Amp with thermal setting 80-100%-01 Nos (OUTGOING) (iii) MCB TP, C-curve, 3 pole 10 KVA 32 Amp with thermal setting 80-100%-01 Nos (OUTGOING) (iv) MCB TP 3 pole 10 KA 16 Amp with thermal setting 80-100%-02 Nos (OUTGOING). (v) MCCB TP 3 Pole 100 Amp 10 KA-01 Nos.
Continue from Srl No 1.0 & 1.1 Note:- (a) The quoted unit cost shall include dismantling of existing LT Cable from LT side of the Transformer and cutting the deterorating cable up to 02 mtr length and supply and fix new cable of existing size LT Cable 02 mtr length. (b) The quoted unit cost shall include earth work such as excavation , Returning & Filling from the existing loop ,Supply and fix on new thimbles with aluminium including . M&L for dead ending cable joint of existing size cable (02 Nos end Joint 01 is towards Transformer and other is LT Panel side. (c) Connection of APFC panel with bus bar of Main LT Panel including supply and fixing new thimbles of LT panel cables of both side with LT cables end dead joint Box-02 Nos . with matching with existing cable 02 Nos (01 Towards bus bar of Main LT Panel and 2nd is towards on connection of APFC panel. (d) GE shallapprove sample for AFC Panel and Individual accessories as per approved make before incorporation of works.
Supply,installing,testing and commissioning factory made and CPRI type tested 45 KVAR APFC panel (25+15+5) Indoor type platform mounted, suitable for 415 volts 3 phase 4 wire 50 Hz AC Supply copper having bus bar of rating 1.5 times that of incoming MCCB installed.The panel shall be dust and vermai proof IP-54 class protection and made of 3.15 mm CRCA MS sheet and 50 x 50 x 6mm thick angle iron frame work; front opening type with double door shutter and locking arrangement with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface. The panel is including platform with PCC 1:4:8 type D-2 with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 3 mtr above the nearest road level all as directed by Engr-in-Charge. All interconnection between the main bus bar as well as outgoind feeders shall be carried out with TP copper bus bar of rating not less than 1.5 time rated capacity of individual outgoing feeders and should be insulated with colour coded shrinkable PVC sleeves. The MCCB should be adjustable type. The body of the panel shall be powder coated . Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift panel safely shall be made. The incommer MCCB as well as outgoings shall have copper TPN extension links (not less than 300 mm long) of current carrying capacity not less than 1.5 times the rated capacity of individual feeders and should be insulated with heat shrinkable PVC sleeves. All control wires shall be of 2.5 sqmm multi stranded copper conductor (FR) and shall be properly bunched, tied,ferruled for proper identification and crimped with adequate size of lugs. A detachable predrilled powder coated gland plate of thickness 3.15 mm should be used at the bottom. The scope of work includes provision of following :- (i) MCCB TP 3 pole 125 Amps 25 KA thermal setting 80-100%, O/C, S/C release-01 No (INCOMING) (ii) MCB TP, C-curve, 3 pole 10 KA 63 Amp with thermal setting 80-100%-01 Nos (OUTGOING) (iii) MCB TP, C-curve, 3 pole 10 KVA 32 Amp with thermal setting 80-100%-01 Nos (OUTGOING) (iv) MCB TP 3 pole 10 KA 16 Amp with thermal setting 80-100%-02 Nos (OUTGOING) (v) APFC relay 04 stage with inbuit P.F meter -02 No.
Continue from Srl Item No 2.0 & 2.1 Note: (a) The quoted unit cost shall include dismantling of existing LT Cable from LT side of the Transformer and cutting the deterorating cable up to 02 mtr length and supply and fix new same size LT Cable 02 mtr length. (b) The quoted unit cost also including its excavation , Returning & Filling from the existing loop , Supply and fix on new thimbles with aluminium including . M&L for dead ending cable joint of existing size cable (02 Nos end Joint 01 is towards Transformer and other is LT Panel side. (c) Connection of APFC panel with bus bar of Main LT Panel including supply and fixing new thimbles of LT panel cables of both side with LT cables end dead joint Box-02 Nos . with matching with existing cable 02 Nos (01 Towards bus bar of Main LT Panel and 2nd is towards on connection of APFC panel. (d) GE shall approve sample for AFC Panel and Individual accessories as per approved make before incorporation of works.
S&F MCCB 4 Pole 500 AMP breaking capacity 36 KA 415 Volt 50 HZ including necessary incoming and outgoing electric connection with suitable size of copper Lugs complete all as specified and as directed by Engineer in Charge.
Supply and Laying , LT UG XLPE insulated 1100 volt grade heavy duty electric cables with aluminium conductor , cross sectional area 240 sqmm 3.5 core all as specified and directed TFR to proposed panel 160 KVA-02 NOS), complete all as specified and directed by Engineer in Charge.
Supply and Laying , LT UG XLPE insulated 1100 volt grade heavy duty electric cables with aluminium conductor , cross sectional area 70 sqmm 3.5 core all as specified and directed (TFR to proposed panel 63 kva), complete all as specified and directed by Engineer in Charge.
Supply anfd fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of cable endjoint kit size 120 sqmm to 185 Sqmm, complete all as specified and directed by Engineer in Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 185 to 240 sqmm,Indoor/Outdoor type, complete all as specified and directed by Engineer in Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 sqmm,Indoor/Outdoor type, complete all as specified and directed by Engineer in Charge.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep for foundation of poles/stays/cables/Pipe lines etc and getting out in soft/loose soil, complete all as specified and directed by Engineer in Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers each not exceeding 25 cm thickness, complete all as specified and directed by Engineer in Charge.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engineer in Charge.
Material and labour for sand cushioning with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches, complete all as specified and directed by Engineer in Charge.
Supplying & laying old size sub calss 'B' bricks laid flat in trenches over the cable with length of bricks perpendicular to the direction of cable, adjacent/abutting each other, complete all as specified and directed by Engineer in Charge.
Supply and fixing of earthing complete with galvanised steel steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than 1.5 mtrs below nominal ground level connected to galvanised strip 25x4 mm by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No 3 of SSR Part I connected to earthing test point and testing on completion. all as specified and as directed. Note:- the cast of excavation and earth work PCC pit and PCC cover with handle, funnel & watering pipe, wiremesh,charcoal dust and common salt and earth strip up to 7.5 mtrs long shall be deemed included in the unit rate for earthing, complete all as specified and directed by Engineer in Charge.
Material and labour for PCC 1:3:6, type C-1, using 20mm graded stone aggregate for road cutting / making plith for transformer where required and fair finishing to exposed surfaces without using extra cement including necessary form work complete all as specified and directed by Engineer in Charge.
Supply and fixing of GI tubing light grade of 100 mm dia for cable protection on pole/wall/floor or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall, complete all as specified and directed by Engineer in Charge.
Supply and fixing of Synthetic Insulating Mat for Electrical Instrument of size 2.5mx1mx12mm, complete all as specified and directed by Engineer in Charge.
M&L for Concealed Point wiring complete with 4 Sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 25mm dia ISI marked and conduit accessories fixed concealed in wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 4 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete including provisining of 4 sqmm PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for tOne 3 pin socket outlet. 15 amps,independent,with cables 4 sq.mm size, complete all as specified and directed by Engineer in Charge.
Supply and Laying , PVC insulated and FR PVC Round Sheathed, Copper Conductor conforming to IS: 694 PVC nsulated 1100 volt grade heavy duty electric cables with copper conductor , cross sectional area 4 sqmm 2 core complete all as specified and directed by Engineer in Charge.
Supply and Laying , PVC insulated and FR PVC Round Sheathed, Copper Conductor conforming to IS: 694 PVC nsulated 1100 volt grade heavy duty electric cables with copper conductor , cross sectional area 16 sqmm 4 core complete all as specified and directed by Engineer in Charge.
Supply and Laying , control copper wiring cable PVC insulated and FR PVC Round Sheathed, Copper Conductor conforming to IS: 694 PVC nsulated 1100 volt grade heavy duty electric cables with copper conductor , cross sectional area 2.5 sqmm 01 core complete all as specified and directed by Engineer in Charge.
PRAJAPATI E and S ENGG CO
Aman Enterprises
Rasvinderpalandco
M/S JAINENDRA KUMAR JAIN
P.K ENTERPRISES
JINDAL AND COMPANY
M/s SHIVA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .