| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹27.6 L+₹64,320 (2.39%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹28.2 L+₹1.2 L (4.61%)Rejected-Finance | L3 | Rejected-Finance Third lowest amount quoted | |
| 4 | L4₹29.0 L+₹2.0 L (7.60%)Rejected-Finance | L4 | Rejected-Finance Fourth lowest amount quoted | |
| 5 | L5₹33.2 L+₹6.3 L (23.3%)Rejected-Finance 16 17D PARIYAT GREEN COLONY PHASE 1 MOHANIYA RANJHI RANJHI JABALPUR RANJHI JABALPUR JABALPUR MADHYA PRADESH 482011 UDYAM MP 24 0004781 23AMMPV5324J2ZO B M R MSME STATUS AS VERIFIED | JABALPUR | MADHYA PRADESH | 482011 | L5 | Rejected-Finance Highest amount quoted |
Tender Value
Refer Docs
EMD Value
₹73,000
Closing Date
4 Aug 2022, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2022_MES_522594_2
8413/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (East) Jabalpur
D b(i) and a(ii)
7 documents required · 7 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹73,000
Yes
1 Sept 2022
14 Jul 2022
6 Aug 2022
14 Jul 2022
4 Aug 2022
21 Jul 2022
14 Jul 2022 - 16 Jul 2022
Amount
Supply and fix, connecting, commissioning & testing of electrically driven centrifugal pump set, 2 stage horizontal split case type with stainless steel shaft, shaft sleeve of brass & bronze impeller having discharge capacity of 1500 LPM (minimum) at 90M head, directly coupled with and including suitable size TEFC squirrel cage type 3 phase induction motor 415 Volts, 50 Hz AC supply, 1500 RPM rated capacity of suitable HP complete with standard coupling, coupling guard, company fabricated common MS channel base plate, foundation bolts including PCC foundation of suitable size (Approx 1.00x0.60x0.45M) in PCC 1:2:4 type B1 using 20mm graded stone aggregate, connection to existing electric system including one (01) No. pressure gauge with 15mm brass stop cock, connecting to existing GI/ CI suction and delivery pipe line with & including joining materials such as flange ends GI/ CI reducers/ expander, MS flanges with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size and testing on completion complete all as specified & directed. Make for Pump: Kirloskar Model No. DSM 100/ 36 or equivalent model of make KSB or CROMPTON or Beacon or JYOTI as approved by GE. Make for Pump Motor: Kirloskar minimum 60 HP or equivalent model of make KSB or L&T or SCHNEIDER or JYOTI or ABB as approved by GE.
Supply and lowering, connecting, commissioning & testing of submersible pump and motor (complete set) having discharge capacity of 480 LPM (minimum) at 87M head, three phase, 415 volts, 50Hz AC supply, electric driven of minimum 15.0HP suitable for 200mm dia bore well complete all as specified & directed. Make: Kirloskar or equivalent model of make KSB or JYOTI or TULLU as approved by GE.
Supply and fix in replacement, cast iron sluice valve 150mm bore, class PN-1.6 of make as approved by GE, conforming to IS-14846, both end flanged with stainless steel spindle, GM nut & CI wheel including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed. Make:- ZOLOTO or LEADER or KIRLOSKAR or UPADHYAY or AUDCO or IVC as approved by GE.
Supply and fix in replacement, cast iron sluice valve 100mm bore, class PN-1.6 of make as approved by GE, conforming to IS-14846, both end flanged with stainless steel spindle, GM nut & CI wheel including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed. Make:- ZOLOTO or LEADER or KIRLOSKAR or UPADHYAY or AUDCO or IVC as approved by GE.
Supply and fix in replacement, cast iron non return valve 150mm bore class PN-1.0 with GM seating of make approved by GE, conforming to IS-5312, both end flanged including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed. Make:- ZOLOTO or LEADER or KIRLOSKAR or UPADHYAY or AUDCO or IVC as approved by GE.
Supply and fix in replacement, cast iron non return valve 100mm bore class PN-1.0 with GM seating of make approved by GE, conforming to IS-5312, both end flanged including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed. Make:- ZOLOTO or LEADER or KIRLOSKAR or UPADHYAY or AUDCO or IVC as approved by GE.
Supply, lowering and fixing in replacement, 150mm nominal bore MS ERW pipes heavy (C-Class) having wall thickness 5.40mm conforming to IS: 1239 (Part-I) -2004; length of each pipe 3.0M, both ends threaded with & including one long socket heavy duty (ISI marked) duly welded and testing on completion complete all as specified & directed.
Supply and fix in replacement, fully automatic star delta motor starter of relay range 28-42 Amps in sheet metal enclosure of ML3 FASD type of capacity suitable for 60.0 HP, motor rating AC-3 duty, 415 volts, 50 Hz, three phase including fixing arrangement complete all as specified and directed. Make: L&T Cat No. SS90730 or equivalent model of make ABB or HAVELLS or BCH or SCHNEIDER as approved by GE.
Supply and fix in replacement, motor starter of relay range 11-18 Amps in sheet metal enclosure of MK1 FASD type of capacity suitable for 15.0 HP, motor rating AC-3 duty, 415 volts, 50 Hz, three phase including fixing arrangement complete all as specified and directed. Make: L&T Cat No. SS96257 or equivalent model of make ABB or HAVELLS or BCH or SCHNEIDER as approved by GE.
M&L for cutting of existing 150 mm dia water main for insertion of CI Tee of any size for branch connection complete.
Supply and fixing of CI/DI fittings in replacement i.e. bends (any type, radius and angle), tapers any type (straight, bend increasing, decreasing or double socket etc), T- pieces single branch, 'Y' junciton double branch, cross (all sockets or socket and spigot), collars, caps and plugs etc suitable for & upto 200mm bore pipes complete all as specified and directed.
Supply and lay 80 mm bore GI column pipe heavy grade ISI marked in standard duly threaded with both ends with and including long threaded heavy duty socket and fittings and lowering into well including supplying, lowering ,fixing, commissioning & testing complete all as specified and directed
Supply and fix in replacement, cast iron foot valve 150mm bore of make as approved by GE, conforming to IS-4038, flanged end including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed. Make:- ZOLOTO or LEADER or KIRLOSKAR or UPADHYAY or AUDCO or IVC as approved by GE.
Supply and fix in replacement, cast iron foot valve 100mm bore of make as approved by GE, conforming to IS-4038, flanged end including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed. Make:- ZOLOTO or LEADER or KIRLOSKAR or UPADHYAY or AUDCO or IVC as approved by GE.
Supply and fix PVC insulated unsheathed cable 37/1.56 , 2.5 SQ mm three core Multistanded bright annealed copper conductor for submersible,1100 Volt conf to IS -694 Make- Plaza/ paragon/polycab
Supply and fix PVC insulated unsheathed cable 19/2.1, 4 SQ mm three core Multistanded bright annealed copper conductor for submersible,1100 Volt conf to IS -694 Make- Plaza/ paragon/polycab
Supply and fix MCCB 4 pole MCCB 125 Amp , 50 HZ ,415 volts with rupturing capacity 35 KA with out door type double door box complete with fixing arrengment .
M&L for Earthing complete with galvanized steel earth plate electrods of size 60cmx60cmx6mm thick burried directly in ground vertically(earth pit not less than 3.35 mtr deep below normal ground level) with top edge of the plate not less than 2.75 mtr below normal ground level connected to galvanised iron strip 32 x 6 mm as earthing lead. by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.5 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and comman salt in alternate layers 25 mm dia light grade GI pipe,funnel,wire mesh.concrete 1:3:6 type C-1 for pit and RCC pit cover. PCC pit shall be provided 50 cm away from earth pit and not on the earth pit itself. The extra cost of the watering pipe,bends,elbows shall be included in the unit rate.Note : RCC pit cover shall be precast of RCC 1:2:4type B-1 80mm thick reinforced with XPM weighing not less than 4 Kg/Sqm.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 150sqmm, 3.5core including jointing materials such as cable glands & lugs etc after taking out the existing old unserviceable XLPE cable and testing on completion complete all as directed. Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE.
Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out all as specified.
Returning filling including spreading and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified.
Removal of surplus/spoil on a distance n.exc 25 cm thick in soft loose soil all as specified.
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm laid in trenches for under ground cable all as specified.
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed.
M&L for cable protection GI tubing light grade fixed long the pole/under road/along the wall of size 50 mm bore with necessary clamps all as directed.
Schedule of credit amount of Rs. 31,250.00 to be deducted during AOC
Goodluck Enterprises
Skyline Encon
SHIVALIK ENGINEERING WORKS
VINAYAK ENGINEERING SERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .