Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC | ₹11.9 L Quoted ₹13.8 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹14.0 L+₹20,596 (1.49%)Rejected-Finance FLAT NO 1004 BUILDING NO L 11 KEDAR HOUSING SOCIETY 10TH FLOOR SECTOR NO 21 TALOJA PHASE 2 PANVEL RAIGAD NAVI MUMBAI 410208 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410208 | ₹14.0 L+₹20,596 (1.49%) | L2 | Rejected-Finance Other than L1 Bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
15 Jun 2024, 6:00 pmClosed
GE 873 EWS
Garrison Engineer 873 Engineer Works Section PIN 913 873 C/O 56 APO
Various Maint work related to DG Sets of various capacities at Partapur under GE 873 EWS
2024_MES_652060_2
GE/873/EWS-32/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 873 EWS
Please refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE 873 EWS
₹30,000
Yes
19 Jul 2024
1 Jun 2024
17 Jun 2024
1 Jun 2024
15 Jun 2024
8 Jun 2024
Amount
Draining out the old engine oil from DG set, cleaning of deposits and rectifing leakages, if any, by means of welding, brazing and cleaning of oil tank and Supply and filling of new Engine oil complete all as specified and directed.
Supply and fixing high pressure fuelline sutable for Dg set of capacity 200 KVA to 250 KVA all as specified and directed.
Supply and fixing high pressure fuelline sutable for Dg set of capacity 125 KVA to 180 KVA all as specified and directed.
Supply and fixing high pressure fuelline sutable for Dg set of capacity 82.5 KVA to 100 KVA all as specified and directed.
Supply and fixing high pressure fuelline sutable for Dg set of capacity 35 KVA to 62.5 KVA all as specified and directed.
S&F, testing and commissioning in replacement of self starter 12 V DC suitable for 30 to 125 KVA DG set complete all as specified and directed.
S&F, testing and commissioning in replacement of self starter 24 V DC suitable for 160 KVA to 600 KVA DG set complete all as specified and directed.
Taking down old unserviceable fuel feed pump and S&F feed pump with suitable banjo washers and banjo nuts complete assy for various capacity of DG Sets all as specified and directed.
S&F (in repairs) of fuel shut down solenoied valve kit including takingout old valve assy and making all connection testing for smooth operation in any type DG Set complete all as specified and directed.
M&L for 'B' check kit of DG set 15 KVA to 62.5 KVA complete all as specified and directed.
M&L for 'B' check kit of DG set 82.5KVA to 100 KVA complete all as specified and directed.
M&L for 'B' check kit of DG set 125KVA to 180 KVA complete all as specified and directed.
M&L for 'B' check kit of DG set 200 KVA to 250 KVA complete all as specified and directed.
M&L for 'B' check kit of DG set 600 KVA complete all as specified and directed.
S&F (in repairs) element Air cleaner for DG set cap 15 KVA to 62.5 KVA complete all as specified and directed.
S&F (in repairs) element Air cleaner for DG set cap 82.5KVA to 100 KVA complete all as specified and directed.
S&F (in repairs) element Air cleaner for DG set cap 125KVA to 180 KVA complete all as specified and directed.
S&F (in repairs) element Air cleaner for DG set cap 200 KVA to 250 KVA complete all as specified and directed.
S&F (in repaitrs) element Air cleaner for DG set of 600 KVA complete all as specified and directed.
M&L for top up of concentrated form coolent in radiator of DG Set of any type/Make and capacity, complete all as directed. Make :-Bosch, feelit guard or equivalent. Note: Measurement shall be done only in concentrate form of coolant.
S&F (in repairs) Fuel hose flexible with matalic tape from fuel tank to filter, filter to FIP including allied nut bolt washer and coupling for DG set 35 KVA to 62.5 KVA with and including taking out old hose and making all connection testing for smooth operation complete all as specified and directed.
Ditto all as per item No 21.00 here-in-before but 82.5 KVA to100 KVA
Ditto all as per item No 21.00 here-in-before but 125 KVA to 180 KVA
Ditto all as per item No 21.00 here-in-before but 200 KVA to 250 KVA
Ditto all as per item No 21.00 here-in-before but 600 KVA
S&F (in repairs ) of radiator hose pipe suitable both inlet and outlet of 35 KVA to 62.5 KVA DG Set with including taking out old hose and making all connection , testing for smooth operation complete all as directed.
S&F (in repairs) of radiator hose pipe of 82.5 KVA to 100 KVA DG Set with including taking out old hose and making all connection , testing for smooth operation complete all as directed.
S&F (in repairs) of radiator hose pipe of 125 KVA to 180 KVA DG Set with including taking out old hose and making all connection, testing for smooth operation complete all as directed.
S&F (in repairs) of radiator hose pipe of 200 KVA to 250 KVA DG Set with including taking out old hose and making all connection, testing for smooth operation complete all as directed.
S&F (in repairs) of radiator hose pipe of 600 KVA DG Set with including taking out old hose and making all connection, testing for smooth operation complete all as directed.
S&F in replacement of 12 V 180 AH Battery tubular of specified and directed. Make: Exide/Amron/Tata.
S&F (in repair) of 12 V 150 AH Battery tubular of specified make.
S&F in repair of battery terminals made of brass , suitable for battery of any type /make and capacity , complete all as directed.
Opening and taking out of cylinder head 200 to 250 KVA capcity DG Set Renewal of inlet and exhaust valve, valve guide seats and lapping of valve machining job, pressure testing including renewal of unserviceable parts, reassembling complete testing as required and directed.
Ditto all as per item No 34.00 here-in-before but 125 KVA to 180 KVA
Ditto all as per item No 34.00 here-in-before but 82.5 KVA to 100 KVA
Ditto all as per item No 34.00 here-in-before but 35 KVA to 62.5 KVA
Renewal of anti viberation mounting pad B series of any type or cpacity complete all as directed.
S&F distilled water in sealed packing for DG 12 volts battery complete all as directed.
S&F in replacement of battery charging sets 12V DC automatic type , fixed in DG set /panel with transformer and rectifier etc including rewiring of faulty control completer all as specified and directed.
S&F in replacement of battery charging sets 24V DC automatic type , fixed in DG set /panel with transformer and rectifier etc including rewiring of faulty control completer all as specified and directed.
S&F in repairs of Automatic voltage Regulator (AVR) suitable for DG Set of 35 KVA to 62.5 KVA capacity with and including taking out old AVR and making all connection testing for smooth operation complete all as specified and directed , Model No. Tavr-20(k)
S&F in repairs of Automatic voltage Regulator (AVR) suitable for DG Set of 82.5 KVA to 100 KVA capacity with and including taking out old AVR and making all connection testing for smooth operation complete all as specified and directed, Model No. Tavr-20(k)
S&F in repairs of Automatic voltage Regulator (AVR) suitable for DG Set of 125 KVA to 180 KVA capacity with and including taking out old AVR and making all connection testing for smooth operation complete all as specified and directed, Model No. Tavr-20(k)
S&F in repairs of Automatic voltage Regulator (AVR) suitable for DG Set of 200 KVA to 250 KVA capacity with and including taking out old AVR and making all connection testing for smooth operation complete all as specified and directed, Model No. Tavr-20(k)
Ditto all as per item No 45.00 here-in-before but 600 KVA, Model No. AVRIVER-2
S&F in repairs Rotating diods assembly suitable for DG set of capacity 35 KVA to 600 KVA with and including taking out old diods and making all connection testing for smooth operation complete all as specified and directed.
S&F testing and commissioning in replacement of damaged turbo charger suitable for 200 to 250 KVA capacity including dismantling of old damaged turbo charger with out damaging any other parts complete all as specified and directed.
Ditto all as per item No 48.00 here-in-before but capacity of 82.5 KVA to 180 KVA DG Set.
Dismantling AC alternator assembly of any capacities including taking out of worn out windings of Rotor and stator incl rewinding the coils with suitable guage of super enamelled winding wire of copper, renewal of insulation materials, heat varnishing, connecting leads and terminal plates all as required to make serviceable of the DG and including reassembling the same after necessary testing all as directed. The item rate includes shifting of altternatos from location to workshop and back to the installation complete all as directed. Note : Winding coils of super enameled copper shall be measured & paid separately under relevant item of the schedule.
M&L for copper winding for item No50.00 here-in-before as per existing guage complete all as specified and directed.
S&F (in repairs) Radiator water pump assy 35 to 62.5 KVA capacity complete all as specified and directed.
S&F in repairs electronic controller relay for engine governorr suitable for 62.5 to 600 KVA DG Set all as directed.
Supplying, fixing and testing (in repairs) 400 Amps, 415V, 4 pole on-load changeover switch with sheet metal enclosure, side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Supplying, fixing and testing (in repairs) 100 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Supplying, fixing and testing (in repairs) 200 Amps, 415V, 4 pole on- load changeover switch with sheet metal enclosure, side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
S&F of EMS 555/KG 934/ GC 1211,PCC 1302 suitable for 200 KVA Cummins DGset or other make/model suitable for any DG set of capacity 35 KVA to 600KVA all as specified and directed.
S&F (in repair) DC alternator after removal of for 12 V DCfrom the DG Set of capacity 35 KVA to 600 KVA , and renewal of minor parts like bush, o ring assembly, bush set, sealing kit, including assembling and re fixing at site complete all as specified and directed.after renewal of following major parts if found defected/unserviceable :- Note;- Following items measured & Paid seperately.
Supply only Stator
Supply only Rotor
Supply only Exicitor
Supply only Rectifier plate with diod assembly
Supply only Slip ring voltage regulator
Note:- (i) The cost of transportation (to and from) for all kind of necessary eqpt /T&P shall be arranged /brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (ii). If any complaint which inform to the contaractor by AGE or JE through telephone or verbal direction and the same will not attend by the contractor with in one day a penality of Rs 1000/- per day will be impossed.
Deduct Schedule of Credit of Rs (-) 1,73,710.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount. Note :- Tenderers will not quote against this item being a firm amount.
M/s ASPIRE ENGINEERING ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .