Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC lowest and reasonable | |
| 2 | L2₹17.6 L+₹44,421.80 (2.58%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L2 | Rejected-Finance not lowest | |
| 3 | L3₹18.2 L+₹1.0 L (5.99%)Rejected-Finance | L3 | Rejected-Finance not lowest |
Tender Value
Refer Docs
EMD Value
₹35,000
Closing Date
8 Aug 2022, 6:00 pmClosed
GE AF NAGPUR
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
IMPROVEMENT TO INTERNAL WIRING OF ACH, PROVN OF CABLE AND CONNECTED ITEMS TO BUIDING NO 402A AND CERTAIN MINOR WORKS AT VSN NAGPUR
2022_MES_529189_1
GE/NAG/22-23/8535/14
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF NAGPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE AF NAGPUR
₹35,000
14 Sept 2022
8 Jun 2022
16 Aug 2022
8 Jun 2022
8 Aug 2022
22 Jun 2022
Amount
Taking down DB/main switch of any size and making good disturbed surface of wall/floor complete all as specified.
Taking down carefully sub-main wiring of any description and making good to the disturbed surfaces to match the existing all as specified and as directed by EIC.
M & L for sub main wiring (concealed) complete with four single core 10 Sqmm FR PVC insulated unsheathed stranded copper conductor cable drawn through in and including 32 mm dia rigid non-metallic PVC conduit heavy grade ISI marked and conduit accessories including 10 Sqmm FR PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Make of cable : Polycab, Finolex,Havells Note: 5 run of 10 sqmm & one run of PVC conduit shall be measured as single unit
M & L for sub main wiring (concealed) complete with two single core 6 Sqmm FR PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit heavy grade ISI marked and conduit accessories including 6 Sqmm FR PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Make of cable : Polycab, Finolex, Havells Note: 5 run of 6 sqmm&one run of PVC conduit shall be measured as single unit
M & L for sub main wiring (concealed) complete with two single core 6 Sqmm FR PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade ISI marked and conduit accessories including 6 Sqmm FR PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed.. Make of cable : Polycab, Finolex,Havells Note: 3 run of 6 sqmm&one run of PVC conduit shall be measured as single unit
M & L for sub main wiring (concealed) complete with two single core 4 Sqmm FR PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade ISI marked and conduit accessories including 4 Sqmm FR PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Make of cable : Polycab, Finolex,Havells Note: 3 run of 4 sqmm&one run of PVC conduit shall be measured as single unit
All as per serial item No 6 here-in-after but 20 mm dia rigid non-metallic PVC conduit heavy grade ISI marked with two runs of 2.5 Sqmm and earth continiuty conductor of size 2.5 Sqmm all as specefied and directed.Make of cable : Polycab, Finolex,Havells Note : 3 run of 2.5 sqmm&one run of PVC conduit shall be measured as single unit
M & L for sub main wiring (concealed/surface) complete with two single core 4 Sqmm FR PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories or in PVC Caping/Casing of size 20x12 including 4 Sqmm FR PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface by applying cement plaster, putty and colour wash etc matching with the existing surfaces all as specified and directed. Make of cable : Polycab, Finolex,Havells Note: 3 run of 4 sqmm&one run of PVC conduit shall be measured as single unit
Taking down carefully any type point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and as directed.
M & L for point wiring (concealed) on walls and surface on ceiling complete with FR PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit heavy grade accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls by cutting chases using machine and making good the disturbed surface, with and including suitable modular boxes, switch plates of suitable make and 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed. (a) One light point controlled by one switch
(b) One Ceiling/Wall fan point controlled by one switch
(c) One exhaust fan point controlled by one switch.
(d) One switch socket outlet modular type 3 pin 6 amp on same board.
All as per item No 10 above but 1.5 sq mm cable size and 1.5 sq mm earth continuity wire for one 3 pin socket outlet, 6 amps on Independent board.
All as per item No 10 above but 2.5 sq mm cable size with 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 16 Amps on independent board.
Note for Item No. 1 to 15 :- The disturbed surfaces of wall for concealing box/wiring shall be make good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate for point wiring shall be deemed to include the cost of making good.
S & F 7 Watt LED spot light white/warm white type as reguired surface type suitable for rotating 360 degree and also adjustable in angle complete all as directed. Make : Crompton /Bajaj/Phillips/lucker.
Supply & Fixing new Decorative LED light 18 watt round/square surface mounting flat panel type complete with all accessories & connector etc internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, all as specified. Crompton /Bajaj/Phillips/lucker.
S & F LED security light fitting 25 W made out of pressure die cast aluminium powder coated housing high impact resistant 4 mm thick toughened glass cover and matrix of power LEDs in built electronic driver up to 4 KV surge protection fitted with adjustable pole adopter to enable on site tilt angle setting and input power 25 W system lumens 85/W operating voltage 160-260 V of make : CG Cat Part No. LSTS-25-CDL Note :(i) Rates are deemed to be included for security ligh brackets made out of 25 mm / 20 mm dia GI medium grade tubing of suitable length and bend to shape including fixing MS flat iron clamps, bolts & nuts as per site requirement complete in all respect complete all as specified and as directed.
S & F new 12 Watt LED round/square recessed flat panel light pearl model with locking arrangement in ceiling with a nominal system lumen output of 1200 lumens and a minimum system efficacy of 100 lumen/watt. The luminaire shall have rated system lifetime of 50,000 burning hours at L70. Make : CG Cat Part No. LSCRM-12W-CDL/NW or equivalent in Bajaj/Wipro.
Supply & Fix new master led tube 4ft 20 W LED batten of high-quality materials and design, Extruded aluminum housing enhances safety, High quality PC Diffuser. Reliable and robust housing structure having nominal system lumen output of 2500 lumens and a minimum system efficacy of 125 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70.The luminaire should have a color temperature of 6500K and CRI>83. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The total power consumption should not exceed 20W (including driver) complete all as specified and as directed. Make : CG Cat Part No. CCS-100-20-65-HL2-DP-NWH or equivalent in Bajaj/Wipro.
S & F Surface mounting LED Luminaries and 1 x 10 Watt LED fitting with connecting up with copper 3 core flexible cord of minimum size 1.5 Sqmm size complete all as specified and as directed . Make : CG, Phillips, Wipro/Bajaj
S & F 0-4 step, one module, modular type electronic regulator for ceiling fan 1200 mm sweep, 240 volts, 100 Watts humfree single pole, all as specified and as directed. Make : Legrand Cat No. 675531 or equivalent
S & F Switch modular type, single pole one way 6 Amps, 250 volts Ac suitable for modular switch boxes without indicator, all as specified and as directed. Make : Legrand Cat No. 675501 or equivalent
S & F socket modular type 6 Amps 3 pin 2 module 250 volts all as specified and as directed. Make : Legrand Cat No. 675551 or equivalent
S & F for ceiling rose, surface bakelite, 65 x 50 mm, two to three terminals all as specified and as directed. Make : Leader, Anchor
S & F socket modular type 6/16 Amps, 3 pin combine, 2 module,240 volts all as specified and as directed. Make : Legrand Cat No. 675555 or equivalent
S & F switch modular type 16 Amps,one way with indicator, 1 module,240 volts all as specified and as directed. Make : Legrand Cat No. 675513 or equivalent
S & F power unit for upto 2 ton AC and geyser up to 3.5 KW modular type , 4 module,240 volts all as specified and as directed by EIC. Make : Legrand Cat No. 675558 or equivalent
S & F sheet metal enclosures for DB's for incorporating MCBs, TPN, 4 way, IP-43 with metal double door, 415 volts, as per IS-8623 including taking down the old unserviceable TPN DB, all as specified and as directed. Make : Legrand Cat No 507670, ABB,Seimens.
S & F MCB TPN, 63 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. Make : Legrand Cat No. 408683 ,ABB,Seimens
S & F sheet metal enclosures for SPN DB's with metal double door for incorporating MCBs,IP-43 , 8 way, 240 volts, as per IS-8623 all as specified and as directed. Make : Legrand Cat No 507611, ABB,Seimens
S & F MCB SPN, 32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. all as specified and as directed Make : Legrand Cat No. 408617 ,ABB,Seimens
S & F MCB SP 10-32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc all as specified and as directed Make : Legrand or equivalent in ABB,Seimens
M&L for MCB blanking plate all as specified and as directed
M & L for disconnecting electric supply, taking down fan, dismantling blades carefully after unscrewing nuts and bolts of ceiling fan, wall fan, exhaust fan of any make from existing position and cleaning all dusts and rehanging in position and connecting up electrically including minor items like split pins complete all as specified and as directed by EIC.
Supply and install invertor based split AC of capacity 2.0 TON (Copper coil) electric driven single phase, 230 volts, 5 star rating including all accessories like brackets, rubber tubing, copper tubing, gas charging, with auto filter clean technilogy etc including testing and commissionin as per norms of BEE and making good to the disturbed surface to match the existing surface complete all as directed. Make Hitachi/LG/Blue star/'O' General/Voltas Note :- All cooling /condensing coil should be made of copper material.
Supply and install digital type Voltage stablizer 5 KVA automatic operation single phase naturally air cooled indoor type & designed for input variation between 130 Volt to 300 Volt with output voltage stablized at 230 Volt with accuracy of (+/-)2.5 percent of capacity 15A for split AC of 2.0 TON all as specified and as directed Make: V guard, Steady Volt, Microtek
Supply and fix power unit for AC upto 2 ton, 4 module, 240 volts all as specified and directed. Make: Legrand cat No 675558 or equivalent
Supply and fix PVC rigid conduit pipe 20/25 mm dia including all accessories and necessary saddles with fixing screws, gutties etc. for drain out water all as specified and as directed
Supply and fix split AC stand of outdoor unit suitable for 2.0 ton including necessary fixing arrangement all as specified and as directed
Supply, Installation, Testing & Commissioning ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps, 50 Hz including making necessary incoming and outgoing electrical connection with suitable size of aluminium lugs etc all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70.0 sq mm 3.5 core all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core all as specified and as directed.
M & L for High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 of size 50 mm dia laid in trenches for passing of LT cable complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed by Engineer-in-Charge
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed by Engineer-in-Charge
Supply & Fix sheet metal enclosures for DB V-TPN for incorporating MCCB 125 Amp DPX³ 160 as incoming & MCBs, TP, 6 way as outgoing, IP-54 with metal double door, 250 amps rated busbar, 415 volts, as per IS-8623, all as specified and as directed. Make : Legrand Cat No 507751, ABB, Seimens.
Supply & Fix MCCB 4 Pole, 125 Amps, breaking capacity 16 KA, DPX³ 160 type, 'C' curve confirming to IS/IEC 60898-1 2002, integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. Make : Legrand Cat No. 420016, ABB, Seimens
Supply & Fix MCB TP, 40-63 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. Make : Legrand Cat No. 408661, ABB, Seimens
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core including necessary connections by providing proper lugs complete all as specified and as directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core including necessary connections by providing proper lugs complete all as specified and as directed
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm.
All as per item No 53.00 but of size 185 sq mm
S & F MCCB, 4 pole, 250 Amps , rupturing capacity 36 KA with Enclossure all as specified and as directed (MCCB Make : L &T Cat part No CM98065OOPO or equivalent in Siemens, Schneider, Legrand)
S & F MCCB, 4 pole, 250 Amps , rupturing capacity 25 KA all as specified and as directed (L & T Catpart No CM90634OOPO or equivalent in Siemens, Schneider)
S & F MCCB, 3 pole, 160 Amps , rupturing capacity 25 KA all as specified and as directed (L & T Catpart No CM90631OOMO or equivalent in Siemens, Schneider)
S & F MCCB, 3 pole, 63 Amps , rupturing capacity 25 KA all as specified and as directed (L & T Catpart No CM90517OOHO or equivalent in Siemens, Schneider)
M & L for new earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 25X4mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. Note : GI strip and protection pipes 40 mm GI light grade up to 7.5 metre is included in unit rate
M &L cable jointing kit for 11 KV (Earthed) grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 sqmm all as specified and as directed
All as per item No 60.00 but of size 185 sq mm
M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width not exceeding 20 cm in depth for passing of LT cable complete all as specified and directed .
Material and labour for sand cushioning below and around cable in trenches with river sand all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, class LV, type 1, flat of size size 250mm x 150mm x 40mm all as directed
Supplying and laying reinforced precast concrete cable cover, class HV, type 1 flat of size size 300mm x 180mm x 40mm all as directed
M&L for onload changeover switch of 250 Amp, 4 pole including necessary arrangements for fixing complete all as directed
M & L for fabrication work of LT Panel with 3.15 mm thick MS Sheet, including cutting, welding, moulding all as directed by Engineer-in-charge
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 100 mm bore for protection of cable complete all as specified and directed by the Engineer-in-Charge.
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 40 mm bore for protection of cable complete all as specified and directed by the Engineer-in-Charge.
Material and labour for PCC cable route indicator in mix of 1:2:4 type B1of size 450x200x100 mm with ovel shapeand writing the letter LT cable with synthtic ennamel paint over a coat of yellow paint and embedded with PCC foundation type D2 1:4:8 of size minimum 250mm deapth including necessary earth work complete all as specified and directed.
M & L for PCC 1:2:4 with 20mm graded aggregate type B-1 including finishing work with plaster 15 mm thick CM (1:4) all as directed by Engineer-in-Charge
M/S JAINENDRA KUMAR JAIN
Chinmaya Enteprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .