| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 CrAccepted-AOC 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹11.5 Cr+₹50.1 L (4.56%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹12.3 Cr+₹1.3 Cr (11.9%)Rejected-Finance WZ 487 2 MS BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹12.5 Cr+₹1.6 Cr (14.3%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹13.7 Cr+₹2.8 Cr (25.2%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | M/s Khanna Enterprises L2 | M/S Shiv Shakti Enterprises L3 | M/s Jatindra Construction Company L7 | A S CONSTRUCTION COMPANY L1 | Sood Enterprises L4 | M/S RAJINDER SINGH L5 | ENGINEER CONSTRUCTION PVT. LTD. L9 | Pawansut Infra Projects Pvt. Ltd. L9 | M/s. Shiva Engineers L8 | Jasraj & Company L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Lump sum price worked out by the tenderer for “BUILDING WORK" as listed in Schedule ‘A’ Part - I | 1 | Lump sum | 7,15,00,000 ₹7,15,00,000 | 7,27,00,000 ₹7,27,00,000 | 8,05,00,000 ₹8,05,00,000 | 6,48,75,000 ₹6,48,75,000 Lowest | 7,26,60,000 ₹7,26,60,000 | 7,65,00,000 ₹7,65,00,000 | 9,39,42,600 ₹9,39,42,600 | 9,39,42,600 ₹9,39,42,600 | 9,35,00,000 ₹9,35,00,000 | 9,00,00,000 ₹9,00,00,000 |
| 2.00Subtotal | |||||||||||||
| 3.00 | Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION WORK" as listed in Schedule ‘A’ Part - II | 1 | Pre-priced | 52,000 ₹52,000 | 1,00,000 ₹1,00,000 | 54,424.52 ₹54,424.52 | 54,424.52 ₹54,424.52 | 51,703.29 ₹51,703.29 Lowest | 68,031 ₹68,031 | 72,400 ₹72,400 | 72,400 ₹72,400 | 1,00,000 ₹1,00,000 | 54,424 ₹54,424 |
| 4.00 | M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium protection stove enameling rigid steel conduit as per IS 9537 (Part-II): 1981 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) | 58 | Each | 1,500 ₹87,000 | 1,100 ₹63,800 | 1,200 ₹69,600 | 1,500 ₹87,000 | 1,500 ₹87,000 | 1,500 ₹87,000 | 1,800 ₹1,04,400 | 1,800 ₹1,04,400 | 1,400 ₹81,200 | 1,000 ₹58,000 Lowest |
| 5.00 | M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium protection stove enamelling rigid steel conduit as per IS 9537 (Part-II): 1981 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. | 4 | Each | 1,500 ₹6,000 | 650 ₹2,600 | 400 ₹1,600 | 500 ₹2,000 | 1,500 ₹6,000 | 650 ₹2,600 | 300 ₹1,200 Lowest | 300 ₹1,200 Lowest | 500 ₹2,000 | 1,000 ₹4,000 |
| 6.00 | M & L for point wiring for one 3 pin/ 5 pin 6 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium protection stove enamelling rigid steel conduit as per IS 9537 (Part-II): 1981 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) | 6 | Each | 1,500 ₹9,000 | 1,100 ₹6,600 | 1,200 ₹7,200 | 1,700 ₹10,200 | 1,300 ₹7,800 | 1,650 ₹9,900 | 1,800 ₹10,800 | 1,800 ₹10,800 | 1,400 ₹8,400 | 1,000 ₹6,000 Lowest |
| 7.00 | M & L for point wiring for one 6 pin 15/16 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium protection stove enamelling rigid steel conduit as per IS 9537 (Part-II): 1981 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) | 4 | Each | 1,800 ₹7,200 | 2,500 ₹10,000 | 1,500 ₹6,000 | 2,000 ₹8,000 | 1,500 ₹6,000 | 2,025 ₹8,100 | 2,000 ₹8,000 | 2,000 ₹8,000 | 1,500 ₹6,000 | 1,200 ₹4,800 Lowest |
| 8.00 | Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 450mm sweep with blades and frame including new mosquito stainless steel wire mesh of gauge 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners10mm dia100mm long and making good the disturbed surface complete all as specified and as directed. | 42 | Each | 5,500 ₹2,31,000 | 6,500 ₹2,73,000 | 3,500 ₹1,47,000 | 5,000 ₹2,10,000 | 6,900 ₹2,89,800 | 2,700 ₹1,13,400 Lowest | 7,000 ₹2,94,000 | 7,000 ₹2,94,000 | 4,000 ₹1,68,000 | 5,200 ₹2,18,400 |
| 9.00 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified nd directed | 42 | Each | 4,000 ₹1,68,000 | 4,000 ₹1,68,000 | 3,500 ₹1,47,000 | 2,600 ₹1,09,200 Lowest | 3,000 ₹1,26,000 | 2,700 ₹1,13,400 | 6,300 ₹2,64,600 | 6,300 ₹2,64,600 | 3,500 ₹1,47,000 | 4,500 ₹1,89,000 |
| 10.00 | Supply and fixing LED tube light fitting polycarbonate housing 1 x 18/20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) | 2 | Each | 500 ₹1,000 | 1,500 ₹3,000 | 500 ₹1,000 | 1,200 ₹2,400 | 1,000 ₹2,000 | 1,200 ₹2,400 | 800 ₹1,600 | 800 ₹1,600 | 400 ₹800 Lowest | 640 ₹1,280 |
Tender Value
₹14.3 Cr
EMD Value
₹10.4 L
Closing Date
28 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer Bathinda zone
Zone, Bathinda Mil Stn-151004
PROVISION OF SWIMMING POOL AT SURATGARH MILITARY STATION
2026_MES_749533_1
84548
Open Tender
Civil Works - Water Works
Lump-sum
730 days
GE (A) Suratgarh
As per NIT
8 documents required · 8 mandatory
₹3,000
Yes
₹10.4 L
HQ CE Bathinda Zone, Bathinda Mil Stn-151004
27 Mar 2026
21 Jan 2026
2 Mar 2026
21 Jan 2026
28 Feb 2026
21 Feb 2026
22 Jan 2026 - 28 Feb 2026
1 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Lump sum price worked out by the tenderer for “BUILDING WORK" as listed in Schedule ‘A’ Part - I | 1 | Lump sum | 8,65,00,000 | ₹8,65,00,000 |
| 2 | Subtotal | - | - | - | - |
| 3 | Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION WORK" as listed in Schedule ‘A’ Part - II | 1 | Pre-priced | 67,614.97 | ₹67,614.97 |
| 4 | Subtotal | - | - | - | - |
| 5 | Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Part - III | 1 | Pre-priced | 1,57,764.66 | ₹1,57,764.66 |
| 6 | Subtotal | - | - | - | - |
| 7 | Lump sum price worked out by the tenderer for “ROAD , PATH & CULVERTS WORKS" as listed in Schedule ‘A’ Part - IV | 1 | Pre-priced | 77,61,682.74 | ₹77,61,682.74 |
| 8 | Subtotal | - | - | - | - |
| 9 | Lump sum price worked out by the tenderer for “AREA DRAINAGE WORKS" as listed in Schedule ‘A’ Part -V | 1 | Pre-priced | 20,01,048.47 | ₹20,01,048.47 |
| 10 | Subtotal | - | - | - | - |
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
BOQ_839427.xls
BOQ • 0.33 MB
corri13final.pdf
PDF • 0.56 MB
corrigendum12.pdf
PDF • 0.22 MB
corrigendum11.pdf
PDF • 0.22 MB
Corridendumfinal10.pdf
PDF • 0.54 MB
PDFsam_merge.pdf
PDF • 0.54 MB
corrigendum09.pdf
PDF • 0.18 MB
Corrigendum08complete.pdf
PDF • 1.20 MB
corrigendum07.pdf
PDF • 0.22 MB
PDFsam_merge.pdf
PDF • 2.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .