| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-Finance | L1 | Accepted-Finance ACCEPTED BEING L1 BIDDER | |
| 2 | L2₹45.0 L+₹2.3 L (5.38%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING L2 BIDDER | |
| 3 | L3₹45.3 L+₹2.6 L (6.06%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING L3 BIDDER |
Tender Value
Refer Docs
EMD Value
₹93,200
Closing Date
7 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SHILLONG
GE SHILLONG, SHILLONG DIVISION, SHILLONG - 793002
REPLACEMENT OF ROOF SHEET WITH ALLIED WORKS TO BLDG NO SP 12 TO SP 21 10 BLDGS AT 58 GTC HAPPY VALLEY PROVN OF 02 X SEPTIC TANK ALONGWITH SOAKAGE WELL BEHIND C AND D COY AT ARC HAPPY VALLEY UNDER GE SHILLONG
2022_MES_518290_2
GE/SHL/TOKEN-11/2022
Open Tender
Civil Works
Item Rate
240 days
GE SHILLONG
ASA PER TENDER
9 documents required · 9 mandatory
₹500
GE SHILLONG
₹93,200
Yes
24 Jun 2022
26 May 2022
8 Jun 2022
26 May 2022
7 Jun 2022
26 May 2022
60 days
Amount
S&F pre-painted Galvalume aluminium zinc coating, GI based, corrugated/semicorrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa,as in roof covering/cladding to wall, fixed with self tapping screws, including dismantling of Asbestos cement (corrugated/semicorrugated,etc) sheets in roof coverings, complete all as specified and directed.
S&F pre-painted Galvalume aluminium zinc coating, GI based, plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa,as in roof covering/cladding to wall, fixed with self tapping screws, including dismantling of Asbestos cement (corrugated/semicorrugated,etc) sheets in roof coverings, complete all as specified and directed.
S & F of 2nd class hardwood scantling, clean sawn in any position and any description as in unframed work including dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed workcomplete all as specified and directed.
M&L Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of Creosote oil complete all as specified and directed.
Dismantling of timber scantlings as in fillets, rails, posts, rafters, purlins etc under 40 Sqcm in section of unframed work complete, all as specified and directed.
S&F 2nd class hard wood plain fillets square rectangular or triangular in section clean sawn secured with nails or brads sectional area exc 13 sq.cm n exc 25 sq.cm complete all as specified and as directed.
S&F 2nd class hard wood plain fillets square rectangular or triangular in section clean sawn secured with nails or brads sectional area exc 6 sq.cm n exc 13 sq.cm complete all as specified and as directed.
Demolition of Cement Concrete (RCC chimney) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
M&L for 2nd class hard wood, 20 mm thick boarding,fixed with nails as in eaves board planed one side with butt joint including dismantling boarding of any description complete all as specified and directed.
M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with nails as in ceiling including dismantling wall & ceiling boards of any description including cover fillets complete all as specified and directed.
M&L for 2nd class hard wood plain fillets bullnosed, splayed, chamfered or rounded on one edge or face in section clean sawn, fixed with screws sec are exc. 3 sq.cm & n. exc. 6 sq.cm complete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames,glazed with putty or fixed with beads complete all as specified and directed.
S&F sheet glass 3 mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane including fixing with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description n.exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed.
M&L for preparation of old decorated plastered surfaces of ceiling including cornices, plasters etc and applying Two coat of white wash complete all as specified and directed.
Excavation over areas not exceeding 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
All as per item no 17 above but in soft/disintegrated rock complete all as specified and as directed.
Excavation over areas exc 1.5m deep and not exc 3.0m deep in hard rock and getting out complete all as specified and directed.
Excavation over areas exc 3.0m deep and not exc 4.5m deep in hard rock and getting out complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth as in foundation in soft or loose soil and getting out complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick as in any type of soil complete all as specified and as directed.
Removing of excavated soil to a distance n exc 50m and deposited where directed at a level n exc 1.5 m above the starting point, complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate foundation filling and mass concrete etc complete all as specified and directed by Engineer in Charge.
M&L for PCC (1:2:4) type B2 using 40mm graded stone aggregate foundation filling and mass concrete etc complete all as specified and directed by Engineer in Charge.
M&L for Precast cement concrete block masonry with solid block type C1 (1:3:6, using 20mm graded stone aggregate) exc 10 Cm in width and setting in cement sand mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
M&L for RCC 1:1.5:3 type-A1 ( using 20mm graded stone aggregate) as in walls, retaining walls, basement walls, ballast walls and the like, any thickness above top of footings, including attached pilaster and buttress complete all as specified and as directed by Engineer in Charge.
M&L for RCC 1:1.5:3 type-A1 ( using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer in Charge.
M&L for RCC 1:1.5:3 type-A1 ( using 20mm graded stone aggregate) as in Foundations, including rafts,footings, foundation beams;plinth beams; bases forcolumns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer in Charge.
M&L for RCC 1:1.5:3 type-A1 ( using 20mm graded stone aggregate) as in as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.
M&L for RCC 1:1.5:3 type-A1 ( using 20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts etc complete all as specified and as directed by Engineer in Charge.
M & L for TMT bars 10 mm dia & over, cut to length, bend to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with & including mild steel wire not less than 0.90 mm dia on securing with clips complete all as specified and directed by Engr-in-Charge.
All as per item no-32 above but 6 to 8 mm dia, complete all as specified and directed by Engr-in-Charge.
M&L for Formwork to sides of concrete of rough finished on flat surfaces to faces of walls,retaining walls, abutments,parapets and staircase railings and similar work includingattached pillasters, buttresses,etc., vertical or to batter complete all as specified and as directed by Engineer in Charge.
M&L for Formwork to sides of concrete of rough finished on flat surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed by Engineer in Charge.
M&L for Formwork to sides of concrete of rough finished on flat surfaces to foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed by Engineer in Charge.
M&L for Formwork to sides of concrete of rough finished on flat surfaces of rectangular, square or polygonal sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed by Engineer in Charge.
M&L for Formwork to sides and soffits in rough finished flat surfaces of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves including support,overhangs etc also splays between floors and beams complete all as specified and as directed by Engineer in Charge.
M&L for Pre-cast RCC 1:2:4 type B1, ( using 20 mm graded stone aggregates) as in cover slab and set in cement sand mortar 1:6 including necessary formwork and mould including demolition of old unserviceable one etc complete all as specified and as directed by Engr-in-charge.
M&L for rendering 10mm thick on fair faces of brick or concrete work in CM 1:4 with approved liquid Water proofing compound @ 3% by the weight of cement or as per manufacturers instructionsfinished even and smooth without using extra cement complete all as specified and as directed. (Note: WPC shall be measured and paid separately)
Supply only Integral waterproofing compound as per manufacturer instruction and directed by Engr-in-charge.
M&L for salt glazed stone ware drain pipes 150 mm bore grade ‘A’ laid in trenches and jointed in cement mortar (1:1) including testing complete all as specified and directed.
M & L for cement concrete (1:4:8) type D-2 (using 40 mm grade stone aggrete)as in concrete bed to drain pipes including packing under & haunching against the sides of pipes after they are laid & tested for 150mm bore pipe all as specified and directed.
S&F 110 mm bore PVC (SWR) sewage pipe, single socketed, in any length with rubber ring joints fixed to wall or floor complete all as specified and directed.
S&F 110 mm bore PVC (SWR) Vent cowl with cement solvent, complete all as specified and as directed.
M&L for loose filling with broken brick of guage 80 to 150 mm in soakage pits complete all as specified and directed.
Bharara construction
S K DEY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .