Loading…
Loading…
Tender Value
₹11.7 L
EMD Value
₹23,340
Closing Date
29 Sept 2026, 2:00 pm2d left
EE II CKHED
OFFICE OF THE EXECUTIVE ENGINEER, P.W.Dte. Central Kolkata Health Electrical Division P-12, C.I.T Road(1st floor) KOLKATA
Urgent change of Air Conditioning machine at Old PICU of Pediatric Surgery Department at CB building under NRSMC and Hospital, Kolkata
2026_WBPWD_5022456_1
WBPWD/EE-II/CKHED/eNIT20/26-27 (2nd call)
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
NRS MCH
Please refer Tender documents.
5 documents required · 5 mandatory
₹23,340
central kolkata health electrical division
7 Sept 2026
7 Sept 2026
1 Oct 2026
7 Sept 2026
29 Sept 2026
15 Sept 2026
14 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, Installation, Testing and Commissioning of air cooled ducted split type air conditioning machine with each having a capacity and details as mentioned below suitable for operation on R 32/R-410A /R-407 Green refrigerant comprising of Scroll type compressor hermatically sealed complete with automatic capacity, safety switches, lubrication system with min 5 year (OEM) warranty for both compressor and Printed Circuit Board (PCB) , Suitable capacity squirrel cage induction motor having class 'B' insulation suitable for operation on 415 +/- 10% volts, 50 Hz, A.C. supply for Blower motor, Necessary drive arrangement for blower motor, Matching Air cooled condenser with necessary fittings for refrigerant piping connections, necessary structural support for mounting condensers, Microprocessor based control panel complete with accessories, machine Isolation / disconnect switch, valves and accessories to inter connect compressor and condenser including pressure testing, vacuum. Necessary starters suitable for Indoor & outdoor unit complete with O/L ,U/V, phase reversal protection, single phase preventors i/c copper conductor control and power cable and drain pipe of suitable size and length etc complete as required. The total cooling capacity/heating capacity of tested unit shall have a capacity as per relevant IS code. The lab testing reports as per IS: 8148 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per ISO/International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification as required. | |||||
| 1.1 | Non -Inverter 8.5 TR (3.2 EER) | 2 | Each | - | - |
| 2Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | |||||
| 2.1 | Liquid Line (15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2mm) | 85 | Mtr | - | - |
| 2.2 | Suction Line (28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2
mm) | 85 | Mtr | - | - |
| 3 | S & Laying of 7 core 2.5 sqmm communication cable ( As required as per variation of the make of the air conditioning machines). | 97 | Mtr | - | - |
| 4 | Charges for scaffolding arrangement incl. lifting for outdoor & indoor units (from ground floor to 6th Floor) | 2 | Item | - | - |
| 5 | Supplying & installation of M.S platform (for installation of ODU of one no 8.5 TR ductable split AC) fabricated with two nos MS u-channel of size 75 mm x 40 mm x 40 mm, 6 mm thick at base incl. 2 nos drilled holes, horizontal angle of 40 mm x40mm x 5 mm in four outer edges and two nos angular support from bottom portion for transmitting the load centrally including 6 nos vertical MS angle of size 25 mm x 25 mm x 6 mm with 25mm x 3mm MS flat for barricading the structure properly for safe maintenance. The platform will be properly grouted inside the wall after cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. and painting. Area of the platform will be 3 Mtr. x 1.2Mtr. or as per machine configuration and load with adequate service aceess as per direction of EIC. (Approximate weight 80 kG)
Structural design should be approved by E.I.C.- For two nos ODU unit. | 240 | Each | - | - |
| 6S & L of Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors. | |||||
| 6.1 | 50 mm dia | 105 | Mtr. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
Tendernotice_2.pdf
PDF • 0.23 MB
BOQ_5103954.xls
BOQ • 0.27 MB
2911.pdf
Tender Documents • 0.50 MB
CKHEDPWDMakeList20F2.pdf
Tender Documents • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .