Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.0 LAccepted-AOC | 1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | 2₹16.4 L+₹93,536 (6.03%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | 2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹17 L
EMD Value
₹42,500
Closing Date
13 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF SRINAGAR
CWE AF SRINAGAR
REPAIR/MAINT OF SPLIT AC WINDOW TYPE AC DEEP FREEZER PACKAGE TYPE AC AND CENTRAL TYPE AC PLANTS AT 8 FBSU AF STN AWANTIPUR
2021_MES_472840_2
CWE(AF)SGR/AWA-19/2021-22
Open Tender
Civil Works
Item Rate
180 days
AF AWANTIPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE AF AWANTIPUR
₹42,500
Yes
22 Oct 2021
21 Sept 2021
15 Oct 2021
21 Sept 2021
13 Oct 2021
29 Sept 2021
60 days
Amount
Taking down carefully Air conditioner Window type AC 1.5 ton to 2 ton and split type AC 1 ton to 2 ton opening for replacing the defective parts including disconnecting the electric connection for replacing defective parts and re-installed the same in original position and making necessary electric connection and testing complete all as specified and directed by Engr-in-Charge.(Labour included for fixing charges item required will be measured and paid separately). Note :- (i) Replacement of defective spares for making the AC units in satisfactory working condition will be measued & paid separately under relevent items and labour charges for taking out old spares and refixing f new spares shall deemed to included in unit quoted rate. (ii) Penalty will be charged for not attending complaint from 12Hours to 24 Hours after intimation (jIntimation will be given by message/whats app/mail by mentioning time of complaint, for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues.
Supply and fixing of blower fan motor in replacement suitable for cooling unit of Window type ACs of capacity 1.5/2.0 TR complete all as specified and directed. (Make-AUE/Cromption Greaves/Cool Master).
Supply and fixing of condensing coil as per existing make for 1.5/2.0 Ton for window AC capacity as directed by Engineer-in-Charge. (Make-Voltas/Carrier/LG).
Supply and fixing of front show grill for window type AC of capacity 1.5/2.0 Ton as per existing make and model complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of thermostat for window type AC of capacity 1.5/2 Ton. Complete all as specified and directed by Engineer-in-Charge. (Make : -Indfos/Renutrol).
Supply and fixing of Condensing Fan Motor as per Existing Make and Capacity For 1.5/2 Ton Window Type AC Complete all as specified and directed by Engineer-in-Charge. (Make : -AUE/Crompton Greaves/Cool Master).
Supply and fixing of outer cover in replace of broken of inner unit in replacement suitable for split AC any type any size complete all as specified and directed.
Supply and fixing of outer cover of outer unit in replacement suitable for split AC any type any size complete all as specified and directed.
Supply and fixing of reverse valve in Split type AC to make it functional for heating also. (Make : -As per sample approved by GE).
Supply and fixing capacitor capacity 4 MFD for AC. complete all as specified and directed by Engineer-in-Charge. (Make : -Epcos/Usha/Keltron).
Removing the burnt blower motor window AC 1.5 TR/2 TR rewinding with super enameled copper winding wire with same gauge and superior quality with same gauge and insulation material such as varnish, cotton tape, including gun metal bush bearing shaft and refixing of original position complete with testing etc complete all as specified and directed.
Material and labour for rectification of Gas leakage (if any) and cleaning the air filter evaporator condenser complete servicing window/split type AC 1.5 TR/2 TR including charging of gas ( rate for gas will be paid separately) , Greasing lubrication of rotary parts and making serviceable including removing the window type AC split Type AC 1.5 TR/2 TR from site & refixing in same position after repair complete with testing etc complete all as specified and directed.
Supply and fixing of in replacement U/S compressor with new compressor capacity 1.5 Ton for window AC as per existing make as directed by Engineer-in-Charge. (Make : -Emerson/Tecumseh/LG). Note : - Transportation charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
All as per item No. 13 above but for 2.0 Ton capacity. (Make : -Emerson/Tecumseh/LG). Note : - Transportation charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
Supply and fixing in replacement U/S compressor with new compressor capacity 1.5 Ton for split AC as per existing make as directed by Engineer-in-Charge. (Make : -Emerson/Tecumseh/LG). Note : - Transportation charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
All as per item No. 15 above but for 2.0 Ton capacity. (Make : -Emerson/Tecumseh/LG). Note : - Transportation charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
Supply and fixing in replacement U/S compressor with new compressor capacity 1.5/2.0 Ton for invertor AC as per existing make as directed by Engineer-in-Charge. (Make : -Emerson/Tecumseh/LG). Note : - Transportation charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
Supply and fixing of air filter for split type AC. complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of blower fan motor in replacement suitable for cooling unit (Outdoor unit) of split type ACs of capacity 1.5/2.0 TR complete all as specified and directed. (Make-AUE/Cromption Greaves/Cool Master).
Supply and fixing of Condensing Fan Motor as per existing Make and capacity for 1.5/2.0 Ton Split Type AC complete all as specified and directed by Engineer-in-Charge. (Make-AUE/Cromption Greaves/Cool Master).
Removing the burnt blower motor split Ac 1.5 TR/2 TR rewinding with super enameled copper winding wire with same gauge and superior quality with same gauge and insulation material such as varnish, cotton tape, including gun metal bush bearing shaft and refixing of original position complete with testing. (Make-AUE/Cromption Greaves/Cool Master).
Supply and fixing in replacement of Fan blade Split AC Capacity 1.5 Ton/2.0 ton.
Supply and fixing of capacitor as per existing make and capacity 45 MFD for compressor of split/window type AC capacity 1.5/2.0 Ton. Complete all as specified and directed by Engineer-in-Charge. (Make : -Epcos/Usha/Keltron).
Supply and fixing of swing motor with flapper in replacement suitable for split type ACs of capacity 1.5/2.0TR complete all as specified and directed.
Supply and fixing of condensing coil as per existing make for 1.5/2.0 Ton capacity split AC as directed by Engineer-in-Charge. (Make-Voltas/Carrier/LG).
Supply and fixing of starting capacitor of 6 MFD in replacement suitable for blower motor of split type ACs of capacity 2.0 TR complete all as specified and directed. (Make : -Epcos/Usha/Keltron).
Supply and Fixing of outer unit to inner unit assembly copper pipe of suitable size for split AC complete all as specified and directed by Engineer-in-Charge. (Make : -Malysia/Cemipro/Equivalent).
Supply and fixing of LED display in replacement of existing us LED suitable for window/split AC any type any size complete all as specified and directed.
Supply and fixing of starting capacitor as per existing make and capacity 100/120 MFD for compressor of window/split type AC capacity 1.5/2.0 Ton. complete all as specified and directed by Engineer-in-Charge. (Make : -Epcos/Usha/Keltron).
Supply and fixed of air sweep louvers with motor complete set in replacement suitable for window type ACs of capacity 1.5/2.0 TR complete all as specified and directed.
Supply and fixing in replacement PVC sheathed, 4 core copper conductor flexible cable of size 2.5 Sqmm with thimbles of suitable size & shape complete all as specified and directed. (Make : -NICCO/FINOLEX/RR KABEL/ HAVELL'S/ POLYCAB/KEI INDUSTRIES LTD).
Supply & fixing of Power Circuit Board (PCB) for 1.5/2.0 TR capacity any type AC as per existing make, all as specified and directed by Engr-in-Charge.
Material and labour for servicing of refrigerator of any make and capacity, opening the refrigerator and replacing the defective parts including disconnecting electric connection and reinstalled the same after repair/replacement and testing Complete all as specified and directed by Engineer-in-Charge (Labour included for fixing charges item required will be measured and paid separately). Note :- (i) Replacement of defective spares for making the refrigerator units in satisfactory working condition will be measued & paid separately under relevent items and labour charges for taking out old spares and refixing f new spares shall deemed to included in unit quoted rate. (ii) Penalty will be charged for not attending complaint from 12Hours to 24 Hours after intimation (jIntimation will be given by message/whats app/mail by mentioning time of complaint, for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues.
Supply and fixing of in replacement U/S compressor with new compressor for refrigerator of capacity 1/6HP as per existing make for capacity 280/300/310 Ltrs directed by Engineer-in-Charge. (Make :- Emerson/Tecumseh/LG).
All as per Srl item No. 47 above but 1/8 HP for 165/180/210 Ltrs capacity. (Make :- Emerson/Tecumseh/LG).
Suppy and fixing of compressor of 405 Ltr Voltas Deep freezer including filling up of Gas (Note: Rate for Gas shall be paid separately). (Make :- Emerson/Tecumseh/LG).
Supply and fixing in replacement of old U/S vegetable tray for any make of refrigerator for the capacity of 280/300/310 Ltrs, complete all as specified and directed by Engr-in-Charge.
Supply and fixing the new freezer door panel and gasket as per existing make and design by removing old u/s door panel and gasket from refrigerator of 280/300/310 Ltrs capacity Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC stand for refrigerator of capacity 280/300/310 Ltrs . Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of over load/starting relay suitable for any make of refrigerator complete with testing and commissioning for the capacity of 280/300/310 Ltrs complete all as specified and directed by Engr-in-Charge. (Make :- Renutrol/Sri Ram/Microtech).
Supply and fixing in replacement of over load/starting relay suitable for any make of refrigerator complete with testing and commissioning for the capacity of 165/180/210 Ltrs complete all as specified and directed by Engr-in-Charge. (Make :- Renutrol/Sri Ram/Microtech).
Supply and charging of non CFC based gas R-134 A for refrigerator/ Deep Freezer Complete all as specified and directed by Engineer-in-Charge .
Supply and charging of gas R-22/R-410A for window AC/ Split AC Complete all as specified and directed by Engineer-in-Charge. (Make : - Mefron/Floron/Refron).
Supply and charging of gas R-407C for window AC/ Split AC/ refrigerator/ Deep Freezer Complete all as specified and directed by Engineer-in-Charge. (Make : - Mefron/Floron/Refron).
Renewal of gas R-410A for window AC/ Split AC/ refrigerator/ Deep Freezer Complete all as specified and directed. (Make : - Mefron/Floron/Refron).
Taking out unserviceable main PCB from voltage stabilizer and replacement of defective parts/components by new one and making serviceable and re fixing back of the 3.0 KVA to 5.0 KVA capacity.
Taking out unserviceable auxiliary transformer and supply and fixing new auxiliary transformer for the 3.0 KVA to 5 KVA capacity stabilizer.
Taking out burnt over main transformer and rewinding the same with super enameled copper winding wire including providing proper insulating material and varnishing complete, fixing back to its original position and making necessary connections, testing complete all as directed for the 3.0 to 5.0 KVA capacity complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of toggle switch/push button suitable for any capacity of voltage stabilizer as directed. (Make : - AE/Rishabh/Meco).
Supply and Install Voltage stabilizer wall mounted Electronic type with input & Output display, Overload & under voltage Relay ,time delay relay : single phase naturally air cooled indoor type & designed for input variation between 140 V to 260 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA. (Make : - Renutorl/Technomac)
Material and labour for flexible water pipe for indoor unit of 2 meter length.
Duct insulation 25 Sqmm with resin bonded fibre glass wool roll of density 24 kg/ Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following:- (a) Cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Applying rubber based adhesive CPRX compound. (c) Sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50 mm wide to make the insulation leak proof. (d) Securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/ 50 mm at maximum intervals of 1.20 metres.
Replacement of single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB up to 20 amp, 240 volts complete. (Make : Schneider/Legrand/ABB/Siemens/L&T)
Supply and fixing in replacement Lub oil filter suitable for capacity 160KVA DG set. Make : Kirloskar, Jyoti/Cummins.
Supply and fixing in replacement fuel filter suitable for capacity 160KVA DG set. Make : Kirloskar, Jyoti/Cummins.
Supply and fixing in replacement air filter suitable for capacity 160 KVA DG set. Make : Kirloskar, Jyoti/Cummins.
Supply and fixing alternator 12 V suitable for DG set 100 KVA including US dismantling all as directed by Engr-in -Charge.
Supply and filling Coolant in radiator assembly complete all as directed.
Supply and filling lub oil 15 W 40 for topup/replacement including draining out old oil from Engine chamber compelte all as directed. Make:- Castrol, Servo.
Supply only distilled water for batteries complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement fan belt V type suitable size for 100 to 160 KVA DG set.
Supply and fixing of battery12 V, 150 AH complete all as specified and directed.
Supply and replacement of on load change over switch 250 Amps 4 Pole 415 Volts front handle operated with sheet metal enclosure complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of on load change over switch 200 Amps 4 Pole 415 Volts front handle operated with sheet metal enclosure complete all as specified and directed by Engineer-in-Charge.
Material and labour for dismantling of defective water pump assembly by disconnecting of hose pipe connections, fanbelt, radiator connection including radiator and repairing with seal etc to make leak proof suitable for DG set capacity for 100 KVA to 160 KVA.
Carrying out top over hauling of DG set 100 KVA including opening of upper portion of diesel engine including taking out heads, pistons, water sleeve, inlet and exhaust valve to facilate the repair work, adjustment of tappet of engine with the help of filler gauge for proper movement of valves. Assemblng of engine after carrying out overhauling work and testing the sane for its firing, prevention of any leakage and testing the same to the satisfaction of Engineer -In-Charge.
Supply only following parts to be fixed under above item for DG set of capacity 100 KVA, Make: crompton greaves (a) Fuel filter primary. (one new will be replaced during routine maintinance due after overhauling)
(b) Fuel filter secondary (one new will be replaced during routine maintinance due after overhauling).
(c) Lub oil filter (one new will be replaced during routine maintinance due after overhauling).
(d) Air cleaner filter.
(e) Hose pipe set with clamps
(f) Flexible pipe with end connector
(g) Fan belt for charging alternator
(h) Fan belt for radiator
(l) Stop solenoid actuator
Material and labour for head decarbonising, grinding of valve seat, lapping of inlet and outlet valves refixing the same after replacement of rubber rings of 100 KVA DG Set.
Material and labour for water sleeve assembly of 100 KVA DG including cleaning and smoothing of bore of engine top block and testing the same for free movement of piston in the sleeve complete all as specified and directed.
Material and labour for water pump assembly of 100 KVA DG Set.
Material and labour for thermostat switch of 100 KVA DG.
Material and labour for turbocharger repair kit of 100 KVA DG.
Material and labour for head gasket set of100 KVA DG Set.
Routine maintenance of DG set Engine of capacity 160 KVA as per manufacturer recommendation for proper functioning of all system like fuel system , lubrication system, hoses,AVMS for wear, tightening of exuast and electric connection replacement of any parts found unserviceable. any spare required for replacement including filter ,pipe,oil to be measured and separately against item 'fixing only" the job does not include the works scope for any engine repairs like overhauling of engine,repair to turbo charger , radiator cleanness other major items of engine complete all as specified and directed by engineer in charge.
Ditto all as per item serial No-73 above but of capacity 100 KVA DG set
Servicing cleaning of radiator of DG Set of capacity 250 KVA by taking out the radiator from existing foundation and removal of light deposit with the use of low pressure stream jet and immersion in heated alkali degreasent solution for 20 minutes for stubborn deposits and washing off with hot water hose and re-installation of the radiator to the satisfactory of Engr-in-Charge.
Ditto all as per item serial No-75 above but of capacity 100 KVA DG set
Cleaning of alternator unit of DG set of capacity 100 KVA to 160 KVA with the help of air blower to wipe dust, oil or any other unwanted liquid /solid from winding of alternator after disconnecting all electric connection and recircuit the connection after carrying out the repairscomplete all as specified and directed.
Supply and fixing in replacement of strip heaters 240 volts with thermostat, 3 KW, cat part no DTA (TH) Heaters 1025 Make Daspass or equivalent, complete all as specified and as directed by Engineer-in-charge.
Cleaning and maintenance of cooling tower for 10/20/30 TR including replacement of defective ducting grills and repair/replacement of defective fins of by taking down of complete fins from the cooling tower and re-installing the fins on its original location after replacing the defective ones complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Plug top 20 Amp 2 pin and earth in replacement, complete all as specified and as directed.
Supply and fixing Plug socket 20 Amp 2 pin and earth in replacement, complete all as specified and as directed.
Dismantling and rewinding of electric motor 3 phase 415 volts Capacity 2 to 5 HP with super enameled copper wire gauge as existing size and varnishing complete including replacement of ball bearing 02 Nos in each, complete all as specified and directed by Engineer-in-Charge
Dismantling and rewinding of electric motor 3 phase 415 volts Capacity 20 HP with super enameled copper wire gauge as existing size and varnishing complete all as specified and directed by Engineer-in-Charge
Servicing and cleaning to Air Handling unit including motor 3 phase 15 HP with replacing of bearing 2 nos,insulating varnish and replacing complete new air filter all as directed Engr in Charge.
Taking out U/S expansion valve capacity upto 26 TR for compressor cooling system and Supply & Fixing new expansion valve complete system with testing, checking of leaking etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of LP valve of capacity upto 26 TR by carefully opening the unserviceable valve from the plant and testing of new valve for leaking etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of HP valve of capacity upto 26 TR by carefully opening the unserviceable valve from the plant and testing of new valve for leaking etc complete all as specified and directed by Engr-in-Charge.
Taking out old UNSV compressor from Package type AC of capacity 10 TR Unit and replacing with the new scroll type compressor capacity 5 TR with all necessary brazing work all as specified and directed. (Consisting of one unit 1 x 5TR).
Replacement of filter valve for 10TR AC plant cooling tower as per sample.
Repair to the AC plants refrigerant system by cleaning and flushing the AC pipings, cooling coil, strainers, filters & liquid line etc, by air pressure by pump and making the complete system leak proof by welding work (gas/electric welding as required) by renewing gasket, ‘O’ rings, taflon sheets, taflon tape etc, as required at site, carrying out the complete pressure and vacuum test (Pressure test carried out by N2 Gas) for 24 hours, all as specified and directed by Engr-in-Charge for the following capacity of AC plants :-
Supply and fix heating element of capacity 6 KW 2 feet push type suitable for 63 KW hot water Generator complete all as specified and directed by Engr-in-charge.
Replacement of microprocessor controlled VFD Drive assembly for controlling humidity panel as on the site exists suitable for motor up to 20 hp, 3 phase, 415 Volts, For 26 TR AC Plant all as specified and directed.
Material and labour for unserviceable MVPD 230 volts AC, Range 5-30 Amps as per sample.
Replacement of old unserviceable control Valve/Gate valve 4'' as per sample.
Replacement of existing unserviceable Temprature meter and Pressure meter as per sample.
Replacement of unserviceable Contactor mnx18 as per given sample.
Replacement of contactor for 32 A rating with ovwerload relay complete all as specified. Make:- Cat part: LHEXBLP7IN1Wo18 of "Havell's" as per sample
Taking out servo voltage stabilizer 100 KVA, 280 to 400 Volts oil cooled unbalance and balanced type oil cooled servo control, electric circuit board, all cable connections, complete overhauling of the system of following capacity stabilizer including repairing/ replacement of push on switch, transistor, capacitor, relay transistor, diode, condenser, voltmeter, PVC connector, indicator lamp, cutout, MCB, complete parts along with testing commissioning and transportation charges from site to workshop all as directed :- Note:- All the spares will be measured & paid separately as supply only under respective items of BOQ. Repair shall be carried out in authorised workshop.
(i) Supply only servo control motor for 100 KVA Voltage Stabilizer with base plate, condenser, capacitor, gear etc.
(ii) Supply only Auto control unit suitable for 100 KVA Voltage stabilizer.
(iii) Supply only Carbon bushes suitable to 100 KVA.
(iv) Supply only Main transformer for unbalanced type voltage stabilizer for the capacity 100 KVA.
(v) Supply only Low/High Voltage Cut off Switch
(vi) Supply only Dimmer Coil for 100 KVA voltage stabilizer
(vii) Supply only brass bushes suitable for 100 voltate stabilizer
(viii) Supply only thimbles for cable connection of size 50 Sqmm to 95 sqmm suitable for Voltage Stabilizer 100 KVA.
(ix) Supply only thimbles for cable connection of size 95 Sqmm to 185 sqmm suitable for Voltage Stabilizer 100 KVA.
Material and labour for descaling the entire water circulation system including condenser including mono block pump set including sealing to avoiding leakage for pump set for existing AC plants by circulating descaling solution of standard value with the help of descaling pump cleaning the condenser tubing with brush attached with rod including renewal of worn out gasket nuts and bolts etc complete all as specified for the following AC plants:-
(ii) 3 x 26 TR
Repair and maintenance of steam generator capacity 3KW, 415Volts AC including replacement of unserviceable parts complete all as specified and directed.
Supply and fixing in replacement MCCB 160A ,4 Pole 35 KA.
Supply and fixing in replacement MCCB 100A ,4 Pole 25 KA.
Replacement of MCB TPN 40 A rating complete all as specified.
Replacement of MCB TPN 32 A rating complete all as specified.
Taking out old UNSV copmressor from Package type AC of capacity 26 TR Unit and replacing with the new scroll type compressor capacity 7.5TR with all necessary brazing work all as specified and directed. (Consisting of one unit 2 x13 TR)
Complete servicing of central/ packaged air conditioner plant capacity 10/15/26 TR including arrangement for inspection of over all parameters of microprocessor controlled chiller water system, Hot water generator, VFD drive controller, humidity controller, Air handling unit get thoroughly checked and necessory repair/ replacement should be done and getting tested up to the satisfaction of Engr in Charge. Note:- All testing material is supposed to be included in the unit rate quoted by contractor.
M/S BASHIR AHMAD AND SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .