RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Potable Water Purification System Reverse Osmosis Or UV Based ( 3 pieces ) Technical Specifications 1/6 * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Certification for the product NA NA Certification number and date - * Manufacturers Quality System Certifications ISO 9001:2015 ISO 9001:2015 Manufacturers Environment Management System Certifications ISO 14001:2004 ISO 14001:2004 Manufacturers Health and Safety Management System Certifications ISO 18001:2007 ISO 18001:2007 Performance Parameters Maximum Input Water TDS allowed to the system 2000 2000 Type of water purification technology RO RO Aavailability of sediment and activated carbon filter Yes * Operation Fully automatic with auto cut off Fully automatic with auto cut off Ultraviolet (UV) LAMP No No Conformity to Standard for Ultraviolet system NA if UV not provided NA if UV not provided "Ultra Voilet (UV) Lamp power in watts (Hint put zero in case UV is not available)" 0 * Recovery at 27 degree Centigrade 30-40 30-40 Output Water Conforming standard IS 10500 (latest) * Filtration Capacity in liter/hour 50 50 Provision of Arsenic removal Yes Yes 2/6 Provision of Floride removal Yes Yes Provision of Chloride removal Yes Yes Alkaline filter Yes Yes Storage tank Not available Not available Type of out put water Storage Tank NA NA Storage Tank Capacity (storage tank external for higher capacity if required to be arranged by buyer) NA NA Minimum inlet pressure 0.6 KG/CM2 0.6 KG/CM2 Maximum inlet pressure 3.5 KG/CM2 * Maximum inlet temperature 35 DEGREE 35 DEGREE Digital display No No Real time TDS display No No Real time pH Display No No High pressure pump Yes Yes Raw water/Chemical Raw water/Chemical Cleaning PUMP No No Micron Filter Yes Yes Total Dissolved Solids Removal Percentage from RO Membrane 90% 90% Particulate Filter Porosity 5 micron 5 micron Pressure vessel Sand Filter Yes Yes Pressure vessel carbon Filter Yes Yes Pressure Vessel Dual Media Filter No No Membrane Housing Yes Yes Body of filter MS Powder Coated MS Powder Coated Auto cut Yes Yes Number of candles 4 4 3/6 Power supply 230 Volt single phase 230 Volt single phase Installation Type Wall mounted Wall mounted Miscellaneous Parameters Warranty in years including replacement of filters Sediment & carbon twice a year) 1 1 Warranty in years free replacement of machine NA NA Antiscalant- where silica is up to 10 ppm/where Mica is up to 100 ppm Yes Yes Availabilty of type test Test REPORT for Filtering Size of micron Particles Yes Yes TYPE Test certificate No and date for Filtering Size of micron Particles - * Name and Address of laboratory which conducted Test for Filtering Size of micron Particles: - * Availability of type Test Report on Microbial Efficacy from Govt/NABL/ilac Lab - * Type Test certificate No and date for Microbial Efficacy - * Name of the lab - * Availability of test report from Govt/NABL/ilac Lab (Design Evalution Report as per IS:14724 Yes Yes Test certificate No and date - * Name and Address of laboratory which conducted Test - * Availability of test report from Govt/NABL/ilac Lab regarding water quality as per IS:10500 Yes * 4/6 Type Test certificate No and date - * Name and Address of laboratory which conducted type Test regarding water quality - * Copies of certifications and reports to be given to buyer at time of supplies Yes * User/Technical/Mainten ance manuals to be supplied in English in hard and soft copy Yes * Availability of toll free centers for customer support Yes Yes Installation and Commissioning inclusive in the scope of Supply* Yes Yes Availability of NABL Accredited Laboratory Facility with OEM Yes Yes Name and Address of NABL Accredited lab with OEM
RequiredIf Not available put NA - * Inlet Pipe & Fitting from raw water scorces to water purification system to be arranged by buyer/consignee to be arranged by buyer/consignee Pipe & Fitting from Out let to purified water tank To be arranged by buyer/consignee To be arranged by buyer/consignee Electrical fitting and plug points To be arranged by buyer/consignee * Scope Civil Work if any required during installation All Civil work shall be responsibility of buyer * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents