Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC Accepted on 03 Jan 2020 | |
| 2 | L2₹9.2 L+₹45,850 (5.27%)Rejected-Finance H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹10.2 L+₹1.5 L (17.4%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹11.3 L+₹2.6 L (30.1%)Rejected-Finance C O OPPOSITE BDO OFFICE MANDA AKHNOOR DISTT JAMMU PIN 181201 | JAMMU | JAMMU AND KASHMIR | 181201 | L4 | Rejected-Finance Rejected | |
| 5 | L5₹12.3 L+₹3.6 L (41.4%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance Rejected |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
7 Dec 2019, 6:00 pmClosed
GE Faridkot
GE Faridkot-151203 Punjab
Repair/ Maint of Street light, main switches, MCBs and Other allied works at Faridkot Mil Stn
2019_MES_298942_1
GE FRD-67/2019-20
Open Tender
Miscellaneous Works
Item Rate
270 days
Faridkot Mil Stn
Class E Category b i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹30,000
Yes
16 Jan 2020
18 Nov 2019
9 Dec 2019
18 Nov 2019
7 Dec 2019
26 Nov 2019
Amount
Taking Down carefully existing security/street light fittings complete from street light bracket fixed on pole/walls after disconnecting all electric connection for repair and refixing in the same position after repair and servicing all as specified and directed by the engineer in charge. Note :- (i) Unserviceable / burnt accessories shall be measured and paid seperately under relevant items mentioned below as supply only items)
Supply only Choke/Ballast copper wound polyster filled 220/240 Volt suitable for 150 watt HPSV/MH lamps fittings fixed on pole/wall complete all as specified and directed by the engineer in charge. Make : Bajaj Cat part No BJOS 150SV/MH /equivalent in Philips/Crompton Greaves
Supply only Choke/Ballast copper wound polyster filled 220/240 Volt suitable for 250 watt HPSV/MH lamps fittings fixed on pole/wall complete all as specified and directed by the engineer in charge. Make : Bajaj Cat part No BJOS 250SV/MH /equivalent in Philips/Crompton Greaves
Supply only 150 watt HPSV lamp , tubular shaped outer shell, internally coated with uniform diffusing powder coated, high pressure sodium vapour lamps with GES cap suitable for 200 to 240 Volts, 50 Hz, AC supply all as specified and directed by the engineer in charge.
Supply only 250 watt HPSV lamp , tubular shaped outer shell, internally coated with uniform diffusing powder coated, high pressure sodium vapour lamps with GES cap suitable for 200 to 240 Volts, 50 Hz, AC supply all as specified and directed by the engineer in charge.
Supply only porcelain lamp holder thread type suitable for HPSV lamps 400 watts to 150 watts fittings all as specified and directed by the engineer in charge. Make : - Philips/Havells/Crompton/Bajaj
S & F in replacement, 250 watt metal halide lamp in existing high mast light complete all as specified and directed by Engineer-in-Charge.
Supply only Ignitor of non integral Bajaj HPSV fittings or equivalent of other specified make suitable for HPSV of 70 watts to 400 watts complete all as specified and directed by the engineer in charge. Make : Crompton Greaves/ Bajaj/ Philips.
Material and labour in replacement of PVC insulated multi stranded aluminum conductor PVC cable sheathed 4 Sq mm single core and making connections of street light fittings with overhead lines/UG Cable complete all as specified and directed by the engineer in charge.
All as per ser item No 9 here-in-before but for 2.5 sqmm single core all as specified and directed by the engineer in charge.
Supply and fixing in replacement contactor single phase AC 220 volts 32- 40 Amps suitable for street timer box as per sample at ground all as specified and directed by the engineer in charge.
Taking down of old unserviceable street light fittings and Supply, fixing and testing LED street light fitting of 45 Watt fitted on 4 to 9 meter high octagonal pole including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-65 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection cover should not degrade due to heating and ageing. The efficient of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report complete all as specified and directed by Engineer-in-Charge. Make: Crompton/ Bajaj/ Polycab /Havells/Halonix/Philips Note :- (a) Bidder shall submit test report of LED street light fitting from accredited test laboratory for LM-79 (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include supply and fixing street light fittings on poles which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. Note: Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days .
Supply, fixing and testing LED flood light fitting of 160Watt including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-66 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED flood light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficieny of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report complete including fabrication of suitable bracket of MS angle iron 50x50x6mm with nuts, bolts to be fixed on pole all as specified and directed by Engineer-in-Charge. Note: (a) Bidder shall submit test report of LED street light fitting from Govt approved accredited test laboratory for LM-79. (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include needful T & P and required accessories etc as per manufacturers recommendation complete including making connection, testing etc complete. Note: Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days .
Supply, fixing and testing LED flood light fitting of 80Watt including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-66 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED flood light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficieny of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report including fabrication of suitable bracket of MS angle iron 50x50x6mm with nuts, bolts to be fixed on pole complete all as specified and directed by Engineer-in-Charge. Note: (a) Bidder shall submit test report of LED street light fitting from Govt approved accredited test laboratory for LM-79. (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include needful T & P and required accessories etc as per manufacturers recommendation complete including making connection, testing etc complete. Note: Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days .
Supply & fixing in replacement street light bracket suitable for 25 - 80 watt LED street light fitting on poles GI light grade pipe, length exc 1mtr but n. exc 1.5 mtr and bent to shape complete all as specified and directed by the engineer in charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed by the engineer in charge.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed by the engineer in charge.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the engineer in charge.
M & L for river sand, washed and screened dry for sand cushioning to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable complete all as specified.
Laying only old burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified and directed by the engineer in charge. Note : Bricks retrieved from existing line shall be relaid.
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed by the engineer in charge.
S & F in replacement 40 mm bore Galvanised iron pipe /tubing, light grade complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed by the engineer in charge. Note : Excavation & Earth work shall be measured and paid separately)
All as per Srl item No. 25 here-in-before but size 20 mm bore dia all as specified and directed by the engineer in charge.
Supply, laying or fixing in replacement , jointing testing and commissioning in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 with cross sectional area 16 Sqmm,4 core, laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note : Excavation, earthwork, sand cushioning and brick protection shall be measured and paid seperately under respective items of BOQ.
All as per item No 27 above but LT cable of cross sectional area 16 Sqmm,2 core all as specified and directed by the engineer in charge.
All as per item No 27 above but LT cable of cross sectional area 25 Sqmm,4 core all as specified and directed by the engineer in charge.
Removal of the old existing paint from indoor/outdoor LT panel complete with emari paper & cleaning and repainting the same with one coat of primer and two coats of good quality existing colour enamel paint with sprayer to make it good as original finish including writing/making 'DANGER 440 VOLTS' etc not exc 30cm height complete all as specified and directed by the engineer in charge.
S&F in replacement pole mounted PVC/FRP looping box of size 225 x 200 x 75 mm including loop out bus bar 100 Amp capacity and railing for fixing MCB, cable terminals necessary fixing arrangement with poles suitable for three phase connection with locking arrangement including necessary nuts, bolts & clamps of flat iron 25 x 3 mm complete 2 Nos. FI clamp & nuts, bolts & washers etc including MCB SP 6-30 A capacity all as specified and directed by the engineer in charge. Make: National/ Havells or equivalent
S&F in replacement isolator TPN 100 Amp, 415 volts complete all as specified and directed by Engineer-in-Charge. Make : Indo Asian Cat No. NBFP1100 or equivalent Model of Schneider/ Havells / Legrand
S&F in replacement isolator TPN 63 Amp, 415 volts complete all as specified and directed by Engineer-in-Charge. Make : Indo Asian Cat No. NBFP1063 or equivalent Model of Schneider/ Havells / Legrand
S&F in replacement MCCB 200 Amp, three pole 415 volts with fixed thermal magnetic release and short circuit protection and breaking capacity not less than 25 KA and making incoming & outgoing connections including thimbles, nut, bolts washers etc complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB 100 Amp, three pole 415 volts with fixed thermal magnetic release and short circuit protection and breaking capacity not less than 25 KA and making incoming & outgoing connections including thimbles, nut, bolts washers etc complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB 63 Amp, three pole 415 volts with fixed thermal magnetic release and short circuit protection and breaking capacity not less than 25 KA and making incoming & outgoing connections including thimbles, nut, bolts washers etc complete all as specified & directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 50mm dia upto earthing test point/equipment fixed with 2 Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, GI protection pipe 40mm bore light grade to PCC chamber in cement concrete (1:3:6) type C-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Note:- (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe shall be provided in slantling position. (iv) Length of earth lead strip & protection pipe shall be upto 7.5mtr
M&L for painting of erected steel tubular swaged poles of LT over head line ( Except embedded portion) , 9 M long complete including all MS work mounted on pole , earth protection & water pipe ( if exists) with one coat of aluminium paint after necessary preparation and providing 07 Nos bands/ straps with synthetic enamel paint ( black and yellow 30 cm wide each) from top of plinth block and numbering of poles with white synthetic enamel paint on black ground complete all as specified and directed by the engineer in charge.
Supply and fixing in replacement of surge protection device (SPD) Suitable for 25 - 80 watt LED street light complete all as specified and directed by the engineer in charge.
Supply and fixing in replacement of Driver Suitable for 25 - 80 watt LED street light complete all as specified and directed by the engineer in charge.
M & L for taking down street light / house service line connections from LT poles, reconnecting the same after removing/ cleaning of carbon, dust over ACSR conductor and jointing with proper size of 2 core extendable cable required at site complete all as specified and directed by the engineer in charge.
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT/HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the LT/HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed by Engineer-in-Charge.
Re-streching of aluminum conductor steel reinforced (ACSR) of any size on over head lines fixed on insulators from 02/04 pole structure after loosening from insulators and fixing on pin, Disc insulator same with new aluminum binding wire 2mm dia complete all as specified and directed by Engineer-in-Charge. Note :- A Sum of Rs. 73,030.00 will be deducted on account of credit for dismantling/demolished/taking down material. Please refer detail on srl page No 24 (Schedule of credit) of Tender Documents.
M/S RAJESH KUMAR and CO.
Singla Electricals
DEEPAK ENTERPRISES
Raman Electric Trading Co
V R TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .