Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.5 CrAccepted-AOC 136 52 MATHALANGULA ST THIUVANNAMALAI 606601 | TIRUVANNAMALAI | TAMIL NADU | 606601 | ₹4.5 Cr Quoted ₹4.6 Cr | 1 | Accepted-AOC WORK AWARDED |
| 2 | 2₹4.9 Cr+₹22.6 L (4.87%)Rejected-Finance SE MOTTUR VILLAGE SERPAPATTU POST THANDARAMPET TALUK TIRUVANNAMALAI DISTRICT 606753 | TIRUVANNAMALAI | TAMIL NADU | 606753 | ₹4.9 Cr+₹22.6 L (4.87%) | 2 | Rejected-Finance Second Lowest |
| 3 | 3₹4.9 Cr+₹29.3 L (6.32%)Rejected-Finance | ₹4.9 Cr+₹29.3 L (6.32%) | 3 | Rejected-Finance Third Lowest |
Tender Value
₹4.5 Cr
EMD Value
₹2.4 L
Closing Date
13 Oct 2023, 3:00 pmClosed
The Special Chief Engineer
The Superintending Engineer, PWD., Buildings Construction and Maintenance Circle,Tiruvannamalai-4.
Construction of Shopping Complex Building Infront of East Rajagopuram at Arulmigu Arunachaleswarar Temple in Tiruvannamalai Town and District.
2023_PWD_377210_1
29/TVM-CLE/23-24/1/ Dt.26.09.2023
Open Tender
Civil Works
Lump-sum
420 days
TIRUVANNAMALAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹2.4 L
18 Nov 2023
11 Oct 2023
13 Oct 2023
11 Oct 2023
13 Oct 2023
11 Oct 2023
Amount
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Providing and laying M-Sand gravel mix as per mixed to a consolidated thickness of 100mm, using 0.67 cm of sand and 0.69 cm of gravel for every cum consolidated sand gravel mix to give a soaked CBR valve of minimuSq.m0 including cost and conveyance of sand and gravel from approved sources to work site and premeasurement including labour charges for mixing the required quantities of sand and gravel to the proportion and consistency using soft portable water to keep up optium moisture content over day and night mixing well on the next morning water sprinkler and laying watering including all leads spreading the mix in layers not less than 10cm and not more than 15 cm watering and consolidating including labour charges for mixing spreading and hire charges fuel charges and running charges for power rollers, water sprinkles and all other tools and plants etc. complete complying with standard specifications.
Supplying and filling in foundation, basement, etc with filling Crushed Stone Sand (M-Sand) and in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling of Gravel by lorry in basement filling including stacking for premeasurement, conveyance, loading and unloading charges and all other incidental charges and including filling laying watering and consolidating etc., complete as directed by the department officers and complying with standard specifications.
Cement Concrete 1:5:10 (One Cement, Five M-sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Cement Concrete 1:5:10 (One Cement, Five M-sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for flooring including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Brick work in Cement Mortar 1:6 (One Cement and Six M-Sand) using best quality of II Class Ground Moulded Chamber Burnt Bricks of size 9" x 43/8" x 23/4" for foundation and basement including curing, etc., complete complying with standard specifiction.
For Foundation and Basement
For Superstructure in Ground Floor
For Superstructure in First Floor
Brick partition walls of 11.50cm thickness using best quality II Class Ground Moulded Chamber Burnt Bricks of size 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three M-Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
For Superstructure in Ground Floor
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance using 20mm with IS:456-2000, and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/ms and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu'm') 7670 kg. of M-Sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
For Foundation and Basement
For Superstructure in Ground Floor
For Superstructure in First Floor
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three M-Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. 110mm dia (For One Floor)
Paving the floor with best quality Stain Free Nano Polish Vitrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M-sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be Johnson / Kajaria / Somany / Nitco / RAK which has to be got approved by Executive Engineer before use on works)
Paving the floor with pre-polished concrete anti-skid step tiles of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three M-Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Supplying and fixing of rolling shutters shall be pull and push type made of 18/Gx3" lath sections which consist of five main parts such as curtain, lock plate, guide channels rollers and hood cover. These five main parts are made out of special components detailed below:Curtain shall be of 18/Gx3" lath sections cut to required size and filled with heavy cast iron / MS clips. For 8' 0" (2.45m) high rolling shutter lath sections provided shall be not less than 37 numbers. Lock plate shall be of 10 GMS sheet reinforced with 40mm x 6mm MS angles at the bottom and fitted with heavy latches and locking arrangements on either sides. There should be one handle on either sides. Guide channel pressed guide channels shall be 10GMS sheet and attached to the side brackets with 20mm square bar. Side brackets shall be of 10G MS plate and cast iron "U" clamps shall be rivetted to the side brackets. Roller shall be of heavy cast iron pullies fitted with heavy duty "C" class 40mm steel pipe and high tensile high carbon coil springs. 2 springs shall be supplied. Side brackets shall be of 10G MS plate and cast iron "U" clamps shall be rivetted to the side brackets. Roller shall be of heavy cast iron pullies fitted with heavy duty "C" class 40mm steel pipe and high tensile high carbon coil springs - 2 springs shall be supplied. Hood cover shall be of 0.8mm CRCA sheet reinforced with 25mm x 25mm x 3 mm MS angle or gate channel. The rolling shutter in addition to the above should have pulling hook and shall be coated on exposed area with heavy coat of red oxide primer.
Manufacturing, supplying and fixing of Steel doors with following specification. MS angle of size 40x40x6mm at 3.5 kg/m used for outer frame and MS Angle of size 35x35x5mm at 2.6 Kg/m for the shutter frame. Stiffeners with 32x6mm at 1.5 Kg/m MS Flat is provided as the lock rail of the door and welded intact on both ends to the shutter frame. 18 G CR Sheets of best quality is laid as panel in the shutter frames. 18x5mm at 0.70 kg/m MS flat is welded over the 32x6mm at 1.50kg/m MS Flat on the rear side of the door, sandwitching the CR Sheet for rigidity. Additional stiffeners with 18x5mm at 0.7 Kg/m MS flats are provided diagonally on the rear side of the shutter. 300mm length of hinges 2 Nos, for shtter is provided. 6 Nos. of 250mm length hold fasts 200mm length specified at the ends are welded to the outer frame of the door. Tower bolt 2 Nos. at the top provided. 250x16mm size of Two aldrops are provided in single leaf door at lock rail section in the door for inner and outer provided and one rotating locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear sideof the door at an appropriate place and 1 No. of M.S. handle of heavy duty. A tie bar is provided at the bottom of the outer frame to prevent twisting of the frame during transportation and fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation, taxes and all other incidental charges, etc., complete. (Single Leaf)
Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification.
Plastering with Cement Mortar 1:5 (One cement and Five M-Sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M-Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers.
Supplying and applying of Two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then be M-sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then M-sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the departmental officers. (The rates are inclusive of hire charges for grinding machine with wheel, cost of M-sand paper (water proof abrasive sheet) cost of putty blade, labour charges for grinding the joints and M-sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc., complete). The putty should be got approved by the Executive Engineer before use on work.
Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. (The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work).
Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work.
P.M.RADHAKRISHNAN
B. Nowsath
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .