Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.7 LAdmitted-Finance THAKURBARI ROAD WARD NO 3 CITY TOWN BIJNI P O P S BIJNI DIST CHIRANG ASSAM PIN 783390 | CHIRANG | ASSAM | 783390 | L1 | Admitted-Finance | |
| 2 | L2₹91.4 L+₹2.7 L (3.03%)Admitted-Finance PAGLASTHAN BONGAIGAON ASSAM | DHUBRI | ASSAM | 783371 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical Refer Technical Minutes |
| Sl No | Description | Qty | Unit | Rana Bora L1 | MANOJ KR. HARLALKA L2 |
|---|---|---|---|---|---|
| 1.00CIVIL WORKS:- | |||||
| 2.00 | Earth work in excavation for foundation trenches of walls ………………
……………………………….………………….. as directed and specified.
(A) Upto a depth of 2.0M bellow the existing ground level.
(a) In ordinary soil | 230.4 | Cum | 100 ₹23,040 Lowest | 140 ₹32,256 |
| 3.00 | Providing Soling in foundation and under floor ………………………….
…………………………………………………. Dewatering complete.
(a) Brick on flat soling. | 1,506.43 | Sqm | 350 ₹5,27,250.5 Lowest | 350 ₹5,27,250.5 Lowest |
| 4.00 | Plain cement concrete work with coarse aggregate of sizes 13mm to 32mm ………………….………………………………………………….curing complete.
(a) In prop. 1 cement: 3 sand: 6 coarse aggregate in volume. | 8.64 | Cum | 4,000 ₹34,560 Lowest | 5,500 ₹47,520 |
| 5.00 | Providing and laying plain reinforced cement concrete works cement, coarse sand & 20mm down graded stone …….………………………………….. cement concrete work.
(I) using mixer machine
(A) In sub-structure upto plinth level.
Foundation,footings,columns etc. …………………………. not less than 100mm thick.
N) Without using admixture, plasticiser
(a) M15 grade concrete or prop. 1:2:4 | 68 | Cum | 5,200 ₹3,53,600 Lowest | 6,500 ₹4,42,000 |
| 6.00 | (B) In super structure from plinth level upto first floor level.
N) Without using admixture, plasticiser
(a) M15 grade concrete or prop. 1:2:4 | 87.86 | Cum | 5,400 ₹4,74,444 Lowest | 7,200 ₹6,32,592 |
| 7.00 | Brick work in cement mortar with first class bricks including racking out joints and curing complete as directed.
(I) In sub structure up to plinth level including dewatering if necessary
(b) In prop. 1:4 | 442.22 | Cum | 5,626.43 ₹24,88,119.87 Lowest | 5,626.43 ₹24,88,119.87 Lowest |
| 8.00 | 1st class brick nagged wall in cement mortar including racking out joints………………
…….upto 1st floor level.
(A) 112mm thick brick wall
(a) in cement mortar in proportion 1:4 (1 cement : 4 sand) | 167.44 | Sqm | 626.89 ₹1,04,966.46 Lowest | 626.89 ₹1,04,966.46 Lowest |
| 9.00 | Providing and laying 25mm thick damp proved coarse with cement concrete in prop. 1:1.5:3 ………………………………….. complete as directed. | 93.68 | Sqm | 174.71 ₹16,366.83 Lowest | 174.71 ₹16,366.83 Lowest |
| 10.00 | Supplying fitting and fixing in position reinforcement bars ……………..
…………………………………………………………. Complete.
(c) ISI approved mild steel reinforcement bars (M.S bar). | 152.23 | Qtl | 6,496.95 ₹9,89,030.7 Lowest | 6,496.95 ₹9,89,030.7 Lowest |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
29 Nov 2021, 3:00 pmClosed
Managing Director, APTDC Ltd
O/O the Managing Director, APTDC Ltd, Ganeshguri Chariali, Ghy-05
Construction of Market Shed at Birhangaon(Hasraobari) Market in Chirang District during 2020-21
2021_WPTBC_23262_1
PTDC/Engg/2018-19/190
Open Tender
Civil Works - Building
Item Rate
270 days
Birhangaon
Please refer Tender documents.
6 documents required · 6 mandatory
₹7,500
Managing Director, APTDC Ltd
₹2.0 L
Yes
6 Jan 2022
30 Oct 2021
2 Dec 2021
30 Oct 2021
29 Nov 2021
2 Nov 2021
Amount
CIVIL WORKS:-
Earth work in excavation for foundation trenches of walls ……………… ……………………………….………………….. as directed and specified. (A) Upto a depth of 2.0M bellow the existing ground level. (a) In ordinary soil
Providing Soling in foundation and under floor …………………………. …………………………………………………. Dewatering complete. (a) Brick on flat soling.
Plain cement concrete work with coarse aggregate of sizes 13mm to 32mm ………………….………………………………………………….curing complete. (a) In prop. 1 cement: 3 sand: 6 coarse aggregate in volume.
Providing and laying plain reinforced cement concrete works cement, coarse sand & 20mm down graded stone …….………………………………….. cement concrete work. (I) using mixer machine (A) In sub-structure upto plinth level. Foundation,footings,columns etc. …………………………. not less than 100mm thick. N) Without using admixture, plasticiser (a) M15 grade concrete or prop. 1:2:4
(B) In super structure from plinth level upto first floor level. N) Without using admixture, plasticiser (a) M15 grade concrete or prop. 1:2:4
Brick work in cement mortar with first class bricks including racking out joints and curing complete as directed. (I) In sub structure up to plinth level including dewatering if necessary (b) In prop. 1:4
1st class brick nagged wall in cement mortar including racking out joints……………… …….upto 1st floor level. (A) 112mm thick brick wall (a) in cement mortar in proportion 1:4 (1 cement : 4 sand)
Providing and laying 25mm thick damp proved coarse with cement concrete in prop. 1:1.5:3 ………………………………….. complete as directed.
Supplying fitting and fixing in position reinforcement bars …………….. …………………………………………………………. Complete. (c) ISI approved mild steel reinforcement bars (M.S bar).
Providing form work ……………………………. Plain concrete work in Columns, pillars, posts and strut of square, rectangular, polygonal in plain or any shape like Tee/L etc having plane vertical face.
Sides and soffits of beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
Earth/ sand filling in plinth in layer not more than ………………. Necessary. (C) With river sand or silt ……………………. Including loading and unloading.
10 mm thick cement plastering in single coat on fair side of brick/concrete wall ………………………………….. complete as directed. (b) In cement mortar 1:4
15 mm thick cement plastering in single coat on fair side of brick/concrete wall ………………………………….. complete as directed. (b) In cement mortar 1:4
(a) Applying one coat of cement primer ………………………… and sand papered smooth.
(b) Finishing wall with water proofing cement paint ………………………… and remains of loose powdered materials.
65 mm thick cement concrete floor ………………………… complete as directed.
Providing, fitting, hoisting and fixing of roof trusses including purlins fabricated out of MS black tube conforming to relevant IS code, as per approved design ………….and drawing as directed. a) TATA make circular hollow section – CHS of grade……………………….. 75 mm OD
Providing corrugated galvd. Iron sheet roofimg ………………….excluding cost of roof truss, perlin etc. (b) 0.50 mm thick
Providing galvd. Iron ridging ……………………………. Complete as directed. (a) 0.50 mm thick (b) 230 mm laping
INTERNAL ELECTRIFICATION:-
Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt.
Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including providing & fixing 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) earthing the 3rd pin of the socket as required on the switch board in flat ISI marked casing 'n' capping system, when fitted on same board of light and fan.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere.
Medium point up to 6.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.),GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete.
Medium point up to 6.00 metre. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity.
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in flat 19 mm ISI marked casing 'n' capping system.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in flat 19 mm ISI marked casing 'n' capping system.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in flat 25mm ISI marked casing 'n' capping system.
With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in flat 25mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity.
With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in flat 32 mm ISI marked casing 'n' capping system.
FITTING ACCESSORIES:-
Supplying and fixing of Jaquar or equivalent Philips/ Wipro LED ceiling light fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required.
LED Ceiling Light 12W
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.
Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make)
Supplying fitting and fixing of ceiling fan regulator including connection etc complete as required
Electronic Type
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic
Power Flow 225 mm sweep (ORIENT make)
Heavy Duty 450 mm sweep 900 RPM Single phase (Crompton make), Heavy Duty 450 mm sweep 900 RPM Single phase (Usha make)
MCB DB,MCCB,MCB & SWITCHGEAR:-
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
4 way TPN (4+12) double door
6 way TPN (4+18) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider neo break, C&S, Havells, Indo Asian, HPL, V-Guard or equivalent make as approved by the Deptt.)
Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series Schneider neo break, C&S, Indo Asian, HPL, V-Guard or equivalent make as approved by the Deptt.)
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider neo break, C&S, Havells, Indo Asian, HPL, V-Guard or equivalent make as approved by the Deptt.)
Supplying with fitting and fixing TPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider neo break, C&S, Havells, Indo Asian, HPL, V-Guard or equivalent make as approved by the Deptt.)
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider neo break, C&S, Havells, Indo Asian, HPL, V-Guard or equivalent make as approved by the Deptt.)
EARTHING:-
Supply, installation & testing of G.I. earth station with perforated 50 mm dia and 3.00 Metre long heady duty G.I. pipe with necessary 50 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 65 mmx50 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of following size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
MANOJ KR. HARLALKA
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .