| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹8.4 L+₹21,415 (2.63%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹11.0 L+₹2.8 L (34.5%)Rejected-Finance 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | L3 | Rejected-Finance NOT L1 |
Tender Value
Refer Docs
EMD Value
₹21,600
Closing Date
22 Feb 2021, 6:00 pmClosed
GE FATEHGARH
GE MES FATEHGARH
SPL REPAIR IN REPLACEMENT OF BER ENERGY METERS , BER CEILING FANS AND FIXING GEYSER OF 25 LITS WITH ALLIED CONNECTION AT FATEHGARH CANTT UNDER GE FATEHGARH.
2021_MES_414711_1
GE/FAT/ET-30 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
120 days
GE MES FATEHGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE FATEHGARH
₹21,600
Yes
19 Apr 2021
22 Jan 2021
24 Feb 2021
22 Jan 2021
22 Feb 2021
7 Feb 2021
22 Jan 2021 - 6 Feb 2021
Amount
Fixing only water heater (geyser) storage type, electric driven single phase 230 volt, 50 Hz of capacity 25 litres complete in all respect including NRV, grouting with suitable size of nut & bolt and necessary cement work incl writiing MES No complete all as directed by Engr - in- Charge. Note:-Geyser will be issued under Sch ''B'' free for fixing
Supply and fixing steel connection pipe with brass /PTMT nuts of reqd length not exceeding 300 mm with rubber & PVC washer suitable for 15 mm bore GI pipe complete for hot water complete all as specified and as directed
Supply and fixing PVC connection heavy duty with brass /PTMT nuts of reqd length not exceeding 300 mm with rubber & PVC washer suitable for 15 mm bore GI pipe complete for cold water complete all as specified and as directed
M&L for sub main wiring with two single core 4 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 2.5 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
S&F metal clad plug & socket with metal plug top enclosure with a two pin and earth plug top and socket suitable for one single pole MCB 32 Amp complete all as specified and directed.
M&L steel water tubing galvanised 15 mm bore medium grade fix in wall/ceiling/floors and all fittings complete all as specified and as directed.
S & fixing Stop valves, cast copper alloy,screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. .
S&F bib taps suitable for 15 mm bore of pipe cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe complete all as specified and as directed. .
M&L for Cutting GI pipes of 15/20 mm bore pipe line as required length for fixing of tee, including welding work complete all as specified.
Taking down carefully existing unserviceable KWH energy meter of any type and depositing to MES store yard complete all as specified and as directed
Taking down carefully existing unserviceable ceiling fan of any type and size and depositing to MES store yard complete all as specified and as directed
S&F single phase KWH energy meter tamper proof electronic type with optical port of capacity 5 - 30 Amp two wire , 240 Volt , class 1.0 for active energy ,LCD display with identity of parameters indicatioin for power on, current reversal , ELT LED plus out put for KWH on front panel incl transparent box with seal arregemnent class IP 65 meter to be fixed on 2nd class hard wood plank of suitable size for base of electric meter and nuts & bolts necessary electic connection including writing MES No complete all as specified and directed. Note:- (i) The quoted rate is deemed to be included for the hard wood plank of base of electric meter.
S&F single phase KWH energy meter tamper proof electronic type with optical port of capacity 10 - 60 Amp two wire , 240 Volt , class 1.0 for active energy ,LCD display with identity of parameters indicatioin for power on, current reversal , ELT LED plus out put for KWH on front panel incl transparent box with seal arregemnent class IP 65 meter to be fixed on 2nd class hard wood plank of suitable size for base of electric meter and nuts & bolts necessary electic connection including writing MES No complete all as specified and directed. Note:- (i) The quoted rate is deemed to be included for the hard wood plank of base of electric meter.
Fixing only ceiling fan of 1200mm sweep , 230 Volt , AC , 5 star rating complete with all accessories and down rod and writing MES No complete all as specified and as directed. Note:- Ceiling fan will be issued under Sch ''B'' free for fixing
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 4 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly including taking down unserviceable submain wiring complete all as specified and directed. Note- (i) The quoted rate is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
M/S J.B.AND SONS
MS. BK BROTHERS AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .