| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹32.3 L+₹59,335 (1.87%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹42.2 L+₹10.5 L (33.1%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹42.5 L+₹10.8 L (34.0%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹42.9 L+₹11.2 L (35.4%)Admitted-Finance NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | S.S.ENGINEERING CORPORATION L4 | Srinivasa Consructions L9 | SHRI GANESH ENTERPRISES L3 | OM SAI POWER SYSTEMS L7 | M/s K Venkateswara Rao L1 | Indu Electricals L2 | M/S J J ENTERPRISES L6 | MM PROJECTS L8 | M/S GDR CONSTRUCTIONS L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down and dismantling old unserviceable damaged, broken / rusted strips including connected items from buildings walls and roofs complete all as directed. | 1,000 | RM | 9 ₹9,000 | 10 ₹10,000 | 12 ₹12,000 | 5 ₹5,000 Lowest | 9 ₹9,000 | 10 ₹10,000 | 5 ₹5,000 Lowest | 5 ₹5,000 Lowest | 20 ₹20,000 |
| 2.00 | Refixing of Copper strip obtained from item No 1 with new saddles and fixing screws as roof / down conductors on insulators or fixed in GI pipe complete all as directed.
Note : 1. Quoted rate shall be deemed to include cost of cutting and jointing copper strips with minimum No of rivets/bolt & nuts.
2. Insulators and GI Pipe will be measured and paid separately. | 100 | RM | 40 ₹4,000 | 20 ₹2,000 | 52 ₹5,200 | 9.51 ₹951 Lowest | 54 ₹5,400 | 25 ₹2,500 | 20 ₹2,000 | 100 ₹10,000 | 50 ₹5,000 |
| 3.00 | S&F, epoxy insulator with one GI stud bolt with nut and washer with necessary drilling for bolt hole for holding or fixing roof / down conductor of lightning complete all as specified and directed | 1,100 | Each | 30 ₹33,000 | 30 ₹33,000 | 18 ₹19,800 | 7 ₹7,700 Lowest | 18 ₹19,800 | 100 ₹1,10,000 | 40 ₹44,000 | 20 ₹22,000 | 35 ₹38,500 |
| 4.00 | S&F in repairs, test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws including taking down ofcomplete all as specified and directed. | 30 | Each | 550 ₹16,500 | 1,000 ₹30,000 | 450 ₹13,500 | 640 ₹19,200 | 432 ₹12,960 | 500 ₹15,000 | 1,200 ₹36,000 | 100 ₹3,000 Lowest | 500 ₹15,000 |
| 5.00 | S&F in repairs, Earth continuity conductor with 20x3mm copper strip fixed to wall on batten or recess or chases with necessary porcelain insulators or buried in ground or drawn in conduit/pipe/wall or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and as directed. | 850 | RM | 450 ₹3,82,500 | 750 ₹6,37,500 | 600 ₹5,10,000 | 670 ₹5,69,500 | 315 ₹2,67,750 Lowest | 600 ₹5,10,000 | 700 ₹5,95,000 | 588 ₹4,99,800 | 325 ₹2,76,250 |
| 6.00 | S&F in repairs, Earth continuity conductor with 25 x 5mm copper strip fixed to wall on batten or recess or chases with necessary porcelain insulators or buried in ground or drawn in conduit/pipe/wall or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and as directed. | 50 | RM | 950 ₹47,500 | 1,710 ₹85,500 | 1,350 ₹67,500 | 1,395 ₹69,750 | 882 ₹44,100 | 1,500 ₹75,000 | 1,400 ₹70,000 | 620 ₹31,000 Lowest | 800 ₹40,000 |
| 7.00 | S&F in repairs, 40mm dia GI pipe light grade fixed to walls or laid in trenches etc., for protection of earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls complete all as specified and directed. | 72 | RM | 425 ₹30,600 | 150 ₹10,800 | 350 ₹25,200 | 120 ₹8,640 Lowest | 351 ₹25,272 | 200 ₹14,400 | 450 ₹32,400 | 200 ₹14,400 | 500 ₹36,000 |
| 8.00 | Cutting of existing bituminious/PCC road or flooring/ plinth protection, for laying of GI pipe in road intersection for passing of LT XLPE cable including excavation in any type of soil, returning and filling in and making good top 30cm of the trench by providing PCC 1:2:4 type B1 using 20mm graded stone aggregate to flush with existing road surface complete all as directed. | 24 | RM | 400 ₹9,600 | 350 ₹8,400 | 400 ₹9,600 | 20 ₹480 Lowest | 342 ₹8,208 | 600 ₹14,400 | 1,000 ₹24,000 | 100 ₹2,400 | 250 ₹6,000 |
| 9.00 | Supply and fix, testing and commissioning of Advanced EarthingSystem
A) Advance Earthing Electrode:
Copper Banded Rod (Tested As CPRI)
"UL Listed" 60MM OUTER DIA X 3 MTR LENGTH COPPER BONDED (250MICRONS COATED ) PIPE , FILLED WITH CONDUCTIVE CRYSTALLINE COMPOUND , FITTED WITH 40X6X3100MM COPPER BONDED STRIP and all connected items all the relvent IEEE 80-1986, IEEE 665-1995, IEC 62561-2. Standards & Tested for:
a) Short Time Current test CPRI 25 KA
b) BendingTest
c) Adhesion Test
d) Dimension Measurment Test,
e) Environmental Test
f) corrosion Test
g) Tensile strength and clongation Test
h) Test for material composition
j) Test for verification of coating thickness
k) Electrical Resistence Mesurement Test. | 275 | Each Set | 13,500 ₹37,12,500 | 15,200 ₹41,80,000 | 12,920 ₹35,53,000 | 14,000 ₹38,50,000 | 10,089 ₹27,74,475 | 9,000 ₹24,75,000 Lowest | 13,000 ₹35,75,000 | 15,000 ₹41,25,000 | 14,000 ₹38,50,000 |
| 9.01B) Low Resistance Advanced compound (Tested as per IEC62561-7 & NABL.AccreditedLab): Eco Friendly Maintenance Free Earthing Compound to enhance Soil Conductivity Packed in Eco- Friendly HDPE Laminated Paper Bags. 25Kgs x 3 Paper Bag. ( 0.19 OHMS PER MTR), tested as per IEC-62561-7, ASTM G 57-06, ASTM G 59-97, ASTM G 102-89. ISO 4689-3 EN 12457-2 Packed in Eco friendly HDPE: Laminated Paper Bags 25Kg x 2 Bags( i.e minimum 50Kg can be increased in case of value observed above 2.0 Ohm) (c) Concrete Inspection Pit Heavy Duty , Precast concrete Earthpit Inspection Chamber with Cover.size 320 mm (W) X 320 mm (L) X 192mm(H), Load Bearing Capacity : 5000Kgs. (d) Installation Installation of Each Earth pit | ||||||||||||
Tender Value
₹47.9 L
EMD Value
₹95,740
Closing Date
15 Nov 2025, 3:00 pmClosed
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
SPECIAL REPAIR REPLACEMENT OF OLD CONVENTIONAL EARTHING SYSTEM TO COPPER EARTHING SYSTEM AT VARIOUS TECHNICAL FACILITY IN RCI HYDERABAD UNDER GE I RCI RND HYDERABAD
2025_MES_736872_1
8335
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(I) R AND D RCI
MES enlisted Class D category b i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹95,740
Yes
27 Nov 2025
25 Oct 2025
17 Nov 2025
25 Oct 2025
15 Nov 2025
8 Nov 2025
Amount
Taking down and dismantling old unserviceable damaged, broken / rusted strips including connected items from buildings walls and roofs complete all as directed.
Refixing of Copper strip obtained from item No 1 with new saddles and fixing screws as roof / down conductors on insulators or fixed in GI pipe complete all as directed. Note : 1. Quoted rate shall be deemed to include cost of cutting and jointing copper strips with minimum No of rivets/bolt & nuts. 2. Insulators and GI Pipe will be measured and paid separately.
S&F, epoxy insulator with one GI stud bolt with nut and washer with necessary drilling for bolt hole for holding or fixing roof / down conductor of lightning complete all as specified and directed
S&F in repairs, test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws including taking down ofcomplete all as specified and directed.
S&F in repairs, Earth continuity conductor with 20x3mm copper strip fixed to wall on batten or recess or chases with necessary porcelain insulators or buried in ground or drawn in conduit/pipe/wall or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and as directed.
S&F in repairs, Earth continuity conductor with 25 x 5mm copper strip fixed to wall on batten or recess or chases with necessary porcelain insulators or buried in ground or drawn in conduit/pipe/wall or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and as directed.
S&F in repairs, 40mm dia GI pipe light grade fixed to walls or laid in trenches etc., for protection of earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls complete all as specified and directed.
Cutting of existing bituminious/PCC road or flooring/ plinth protection, for laying of GI pipe in road intersection for passing of LT XLPE cable including excavation in any type of soil, returning and filling in and making good top 30cm of the trench by providing PCC 1:2:4 type B1 using 20mm graded stone aggregate to flush with existing road surface complete all as directed.
Supply and fix, testing and commissioning of Advanced EarthingSystem A) Advance Earthing Electrode: Copper Banded Rod (Tested As CPRI) "UL Listed" 60MM OUTER DIA X 3 MTR LENGTH COPPER BONDED (250MICRONS COATED ) PIPE , FILLED WITH CONDUCTIVE CRYSTALLINE COMPOUND , FITTED WITH 40X6X3100MM COPPER BONDED STRIP and all connected items all the relvent IEEE 80-1986, IEEE 665-1995, IEC 62561-2. Standards & Tested for: a) Short Time Current test CPRI 25 KA b) BendingTest c) Adhesion Test d) Dimension Measurment Test, e) Environmental Test f) corrosion Test g) Tensile strength and clongation Test h) Test for material composition j) Test for verification of coating thickness k) Electrical Resistence Mesurement Test.
B) Low Resistance Advanced compound (Tested as per IEC62561-7 & NABL.AccreditedLab): Eco Friendly Maintenance Free Earthing Compound to enhance Soil Conductivity Packed in Eco- Friendly HDPE Laminated Paper Bags. 25Kgs x 3 Paper Bag. ( 0.19 OHMS PER MTR), tested as per IEC-62561-7, ASTM G 57-06, ASTM G 59-97, ASTM G 102-89. ISO 4689-3 EN 12457-2 Packed in Eco friendly HDPE: Laminated Paper Bags 25Kg x 2 Bags( i.e minimum 50Kg can be increased in case of value observed above 2.0 Ohm) (c) Concrete Inspection Pit Heavy Duty , Precast concrete Earthpit Inspection Chamber with Cover.size 320 mm (W) X 320 mm (L) X 192mm(H), Load Bearing Capacity : 5000Kgs. (d) Installation Installation of Each Earth pit
Note for ITEM NO. 9 :- 1. Performance Guarantee certificate duly indicating Earth resistance value shouldnot come higher than 2.0 Ohm for period of 05 years , must be provided by contractor/OEM. 2. Contractor will replace the earthing free of cost in case of resistance value of earthing observed above 2.Ohm during the said guarantee period. 3. Any observation regarding performance of earthing system within the said period indicated Accepting officer/Engineer-in-charge will have to be rectify contractor within 24 hours.
Indu Electricals (BID ID -3474929)
SHRI GANESH ENTERPRISES (BID ID -3474883)
S.S.ENGINEERING CORPORATION (BID ID -3471981)
M/S GDR CONSTRUCTIONS (BID ID -3474921)
M/S J J ENTERPRISES (BID ID -3475109)
OM SAI POWER SYSTEMS (BID ID -3474885)
MM PROJECTS (BID ID -3474940)
Srinivasa Consructions (BID ID -3474141)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.07 MB
8335PS.pdf
Tender Documents • 0.39 MB
BOQ_825078.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .